Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Kyobu Geka ; 76(8): 597-601, 2023 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-37500546

RESUMO

An 88-year-old male underwent thoracic endovascular aortic repair (TEVAR) with the double-debranching and chimney technique for arch aortic aneurysm. When the aforementioned procedure was performed, the left common carotid artery was closed and transected, and the left subclavian artery was embolized and bypassed, respectively. However, postoperatively, the gutter endoleak persisted, and the aneurysm enlarged;therefore, requiring additional surgery. A skin incision was made on the left side of the neck, and the closed and dissected left common carotid artery stump was detected. A sheath was placed at the stump and an angiographic catheter and guidewire were used to retrograde cannulate the gutter beside the chimney graft, and coil embolization was performed. No endoleak was observed at postoperatively and 6-month follow up computed tomography( CT). We believe that embolization from a deblanched left common carotid artery stump is useful for endoleaks after TEVAR employing the chimney and debranching technique.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso de 80 Anos ou mais , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/métodos , Aorta Torácica/cirurgia , Prótese Vascular , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Stents , Estudos Retrospectivos
2.
Acta Radiol ; 53(10): 1107-11, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22993270

RESUMO

BACKGROUND: Optimal contrast enhancement is crucial for the detection of coronary artery stenoses and atherosclerotic changes in coronary CT angiography (CTA). PURPOSE: To demonstrate the feasibility of using the cardiac output (CO) obtained from the test bolus injection data-set (COtest) as a factor in contrast injection rate revision of the following coronary CTA. MATERIAL AND METHODS: The test bolus injection data-sets of 52 consecutive coronary CTAs were examined. COtest was calculated from the test bolus data-set. Aortic peak enhancement (APE) was measured on the following coronary CTA. We simulated the APE at a fixed contrast injection rate of 4 mL/s (simAPE) in each patient. RESULTS: The ranges of COtest and simAPE were 2.82-7.56 L/min and 194-527 Hounsfield Units, respectively. There was a significant negative correlation (R = -0.802, P < 0.001) between simAPE and COtest. CONCLUSION: COtest can be used for injection rate revision on coronary CTA.


Assuntos
Débito Cardíaco , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Iohexol/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA