Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Anal Bioanal Chem ; 415(26): 6481-6490, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37682313

RESUMO

Single-cell measurements routinely demonstrate high levels of variation between cells, but fewer studies provide insight into the analytical and biological sources of this variation. This is particularly true of chemical cytometry, in which individual cells are lysed and their contents separated, compared to more established single-cell measurements of the genome and transcriptome. To characterize population-level variation and its sources, we analyzed oxidative stress levels in 1278 individual Dictyostelium discoideum cells as a function of exogenous stress level and cell cycle position. Cells were exposed to varying levels of oxidative stress via singlet oxygen generation using the photosensitizer Rose Bengal. Single-cell data reproduced the dose-response observed in ensemble measurements by CE-LIF, superimposed with high levels of heterogeneity. Through experiments and data analysis, we explored possible biological sources of this heterogeneity. No trend was observed between population variation and oxidative stress level, but cell cycle position was a major contributor to heterogeneity in oxidative stress. Cells synchronized to the same stage of cell division were less heterogeneous than unsynchronized cells (RSD of 37-51% vs 93%), and mitotic cells had higher levels of reactive oxygen species than interphase cells. While past research has proposed changes in cell size during the cell cycle as a source of biological noise, the measurements presented here use an internal standard to normalize for effects of cell volume, suggesting a more complex contribution of cell cycle to heterogeneity of oxidative stress.


Assuntos
Dictyostelium , Microfluídica , Dictyostelium/metabolismo , Ciclo Celular , Estresse Oxidativo , Divisão Celular
2.
Anal Chem ; 90(19): 11344-11350, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30175919

RESUMO

Studies of live cells often require loading of exogenous molecules through the cell membrane; however, effects of loading method on experimental results are poorly understood. Therefore, in this work, we compared three methods for loading a fluorescently labeled peptide into cells of the model organism Dictyostelium discoideum. We optimized loading by pinocytosis, electroporation, and myristoylation to maximize cell viability and characterized loading efficiency, localization, and uniformity. We also determined how the loading method affected measurements of enzyme activity on the peptide substrate reporter using capillary electrophoresis. Loading method had a strong effect on the stability and phosphorylation of the peptide. The half-life of the intact peptide in cells was 19 ± 2, 53 ± 15, and 12 ± 1 min, for pinocytosis, electroporation, and myristoylation, respectively. The peptide was phosphorylated only in cells loaded by electroporation. Fluorescence microscopy suggested that the differences between methods were likely due to differences in peptide localization.


Assuntos
Dictyostelium/citologia , Peptídeos/metabolismo , Dictyostelium/metabolismo , Fosforilação , Proteínas Proto-Oncogênicas c-akt/metabolismo , Coloração e Rotulagem
3.
Analyst ; 143(15): 3643-3650, 2018 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-29969508

RESUMO

Microfluidic chemical cytometry is a powerful technique for examining chemical contents of individual cells, but applications have focused on cells from multicellular organisms, especially mammals. We demonstrate the first use of microfluidic chemical cytometry to examine a unicellular organism, the social amoeba Dictyostelium discoideum. We used the reactive oxygen species indicator dichlorodihydrofluorescein diacetate to report on oxidative stress and controlled for variations in indicator loading and retention using carboxyfluorescein diacetate as an internal standard. After optimizing indicator concentration, we investigated the effect of peroxide treatment through single-cell measurements of 353 individual cells. The peak area ratio of dichlorofluorescein to carboxyfluorescein increased from 1.69 ± 0.89 for untreated cells to 5.19 ± 2.72 for cells treated with 40 mM hydrogen peroxide. Interestingly, the variance of the data also increased with oxidative stress. While preliminary, these results are consistent with the hypothesis that heterogeneous stress responses in unicellular organisms may be adaptive.


Assuntos
Dictyostelium/fisiologia , Técnicas Analíticas Microfluídicas , Estresse Oxidativo , Espécies Reativas de Oxigênio/análise , Análise de Célula Única
5.
Anal Bioanal Chem ; 409(5): 1173-1183, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27900431

RESUMO

Peptide substrate reporters are fluorescently labeled peptides that can be acted upon by one or more enzymes of interest. Peptide substrates are readily synthesized and more easily separated than full-length protein substrates; however, they are often more rapidly degraded by peptidases. As a result, peptide reporters must be made resistant to proteolysis in order to study enzymes in intact cells and lysates. This is typically achieved by optimizing the reporter sequence in a single cell type or model organism, but studies of reporter stability in a variety of organisms are needed to establish the robustness and broader utility of these molecular tools. We measured peptidase activity toward a peptide substrate reporter for protein kinase B (Akt) in E. coli, D. discoideum, and S. cerevisiae using capillary electrophoresis with laser-induced fluorescence (CE-LIF). Using compartment-based modeling, we determined individual rate constants for all potential peptidase reactions and explored how these rate constants differed between species. We found the reporter to be stable in D. discoideum (t 1/2 = 82-103 min) and S. cerevisiae (t 1/2 = 279-314 min), but less stable in E. coli (t 1/2 = 21-44 min). These data suggest that the reporter is sufficiently stable to be used for kinase assays in eukaryotic cell types while also demonstrating the potential utility of compartment-based models in peptide substrate reporter design. Graphical abstract Cell lysates from several evolutionarily divergent species were incubated with a peptide substrate reporter, and compartment-based modeling was used to determine key steps in the metabolism of the reporter in each cell type.


Assuntos
Modelos Teóricos , Eletroforese Capilar , Fluorescência , Especificidade da Espécie
6.
Annu Rev Anal Chem (Palo Alto Calif) ; 17(1): 197-219, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38424028

RESUMO

Analytical chemistry is a fast-paced field with frequent introduction of new techniques via research labs; however, incorporation of new techniques into academic curricula lags their adoption in research and industry. This review describes the recent educational literature on microfluidics, microcontrollers, and chemometrics in the undergraduate analytical chemistry curriculum. Each section highlights opportunities for nonexpert faculty to get started with these techniques and more advanced implementations suitable for experienced practitioners. While the addition of new topics to any curriculum brings some opportunity costs, student engagement with cutting edge techniques brings many benefits, including enhanced preparation for graduate school and professional careers and development of transferable skills, such as coding. Formal assessment of student outcomes is encouraged to promote broader adoption of these techniques.

7.
Anal Chem ; 85(10): 4991-7, 2013 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-23590517

RESUMO

Microfluidic systems show great promise for single-cell analysis; however, as these technologies mature, their utility must be validated by studies of biologically relevant processes. An important biomedical application of these systems is characterization of tumor cell heterogeneity. In this work, we used a robust microfluidic platform to explore the heterogeneity of enzyme activity in single cells treated with a chemotherapeutic drug. Using chemical cytometry, we measured peptide degradation in the U937 acute myeloid leukemia (AML) cell line in the presence and absence of the aminopeptidase inhibitor Tosedostat (CHR-2797). The analysis of 99 untreated cells revealed rapid and consistent degradation of the peptide reporter within 20 min of loading. Results from drug-treated cells showed inhibited, but ongoing degradation of the reporter. Because the device operates at an average sustained throughput of 37 ± 7 cells/h, we were able to sample cells over the course of this time-dependent degradation. In data from 498 individual drug-treated cells, we found a linear dependence of degradation rate on amount of substrate loaded superimposed upon substantial heterogeneity in peptide processing in response to inhibitor treatment. Importantly, these data demonstrated the potential of microfluidic systems to sample biologically relevant analytes and time-dependent processes in large numbers of single cells.


Assuntos
Antineoplásicos/farmacologia , Leucemia Mieloide Aguda/patologia , Técnicas Analíticas Microfluídicas/métodos , Peptídeos/metabolismo , Proteólise/efeitos dos fármacos , Sequência de Aminoácidos , Linhagem Celular Tumoral , Humanos , Cinética , Peptídeos/química
9.
Electrophoresis ; 32(22): 3180-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22012764

RESUMO

Sample transport and electrokinetic injection bias are well characterized in capillary electrophoresis and simple microchips, but a thorough understanding of sample transport on devices combining electroosmosis, electrophoresis, and pressure-driven flow is lacking. In this work, we evaluate the effects of electric fields from 0 to 300 V/cm, electrophoretic mobilities from 10(-4) to 10(-6) cm(2)/Vs, and pressure-driven fluid velocities from 50 to 250 µm/s on sample injection in a microfluidic chemical cytometry device. By studying a continuous sample stream, we find that increasing electric field strength and electrophoretic mobility result in improved injection and that COMSOL simulations accurately predict sample transport. The effects of pressure-driven fluid velocity on injection are complex, and relative concentration values lie on a surface defined by pressure-driven flow rates. For high-mobility analytes, this surface is flat, and sample injection is robust despite fluctuations in flow rate. For lower mobility analytes, the surface becomes steeper, and injection depends strongly on pressure-driven flow. These results indicate generally that device design must account for analyte characteristics and specifically that this device is suited to high-mobility analytes. We demonstrate that for a suitable pair of peptides fluctuations in injection volume are correlated; electrokinetic injection bias is minimized; and electrophoretic separation is achieved.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Modelos Químicos , Análise de Célula Única/instrumentação , Simulação por Computador , Desenho de Equipamento , Peptídeos/química , Fosfatidilcolinas/química , Fosfatidilgliceróis/química , Pressão , Reprodutibilidade dos Testes , Análise de Célula Única/métodos
11.
Anal Methods ; 13(12): 1535-1540, 2021 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-33690748

RESUMO

The high surface area-to-volume ratio of microfluidic channels makes them susceptible to fouling and clogging when used for biological analyses, including cell-based assays. We evaluated the role of electrostatic and van der Waals interactions in cell adhesion in PDMS microchannels coated with supported lipid bilayers and identified conditions that resulted in minimal cell adhesion. For low ionic strength buffer, optimum results were obtained for a zwitterionic coating of pure egg phosphatidylcholine; for a rich growth medium, the best results were obtained for zwitterionic bilayers or those with slight negative or moderate positive charge from the incorporation of 5-10 mol% egg phosphatidylglycerol or 30 mol% ethylphosphocholine. In both solutions, the presence of 10 g L-1 glucose in the cell suspension reduced cell adhesion. Under optimum conditions, all cells were consistently removed from the channels, demonstrating the utility of these coatings for whole-cell microfluidic assays. These results provide practical information for immediate application and suggest future research areas on cell-lipid interactions.


Assuntos
Dispositivos Lab-On-A-Chip , Bicamadas Lipídicas , Adesão Celular , Microfluídica , Eletricidade Estática
12.
Anal Chem ; 82(22): 9357-64, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20961116

RESUMO

Motile bacteria bias the random walk of their motion in response to chemical gradients by the process termed chemotaxis, which allows cells to accumulate in favorable environments and disperse from less favorable ones. In this work, we describe a simple microchannel-nanopore device that establishes a stable chemical gradient for chemotaxis assays in ≤1 min. Chemoattractant is dispensed by diffusion through 10 nm diameter pores at the intersection of two microchannels. This design requires no external pump and minimizes the effect of transmembrane pressure, resulting in a stable, reproducible gradient. The microfluidic platform facilitates microscopic observation of individual cell trajectories, and chemotaxis is quantified by monitoring changes in cell swimming behavior in the vicinity of the intersection. We validate this system by measuring the chemotactic response of an aquatic bacterium, Caulobacter crescentus, to xylose concentrations from 1.3 µM to 1.3 M. Additionally, we make an unanticipated observation of increased turn frequency in a chemotaxis-impaired mutant which provides new insight into the chemotaxis pathway in C. crescentus.


Assuntos
Caulobacter crescentus/citologia , Quimiotaxia , Técnicas Analíticas Microfluídicas , Nanoporos , Caulobacter crescentus/genética , Quimiotaxia/efeitos dos fármacos , Difusão , Dimetilpolisiloxanos/química , Membranas Artificiais , Mutação/efeitos dos fármacos , Reprodutibilidade dos Testes , Xilose/farmacologia
13.
Anal Chem ; 81(17): 7133-40, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19663470

RESUMO

As the field of nanofluidics matures, fundamental discoveries are being applied to lab-on-a-chip analyses. The unique behavior of matter at the nanoscale is adding new functionality to devices that integrate nanopores or nanochannels. (To listen to a podcast about this feature, please go to the Analytical Chemistry website at pubs.acs.org/journal/ancham.).


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/tendências , Nanotecnologia/instrumentação , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/tendências , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/métodos , Nanotecnologia/métodos , Nanotecnologia/tendências
14.
J Am Chem Soc ; 130(27): 8614-6, 2008 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-18549214

RESUMO

We report integrated nanopore/microchannel devices in which single nanopores are isolated between two microfluidic channels. The devices were formed by sandwiching track-etched conical nanopores in a poly(ethylene terephthalate) membrane between two poly(dimethylsiloxane) microchannels. Integration of the nanopores into microfluidic devices improves mass transport to the nanopore and allows easy coupling of applied potentials. Electrical and optical characterization of these individual nanopores suggests double layer overlap is not required to form an ion depletion region adjacent to the nanopore in the microchannel; rather, excess surface charge in the nanopore contributes to the formation of this ion depletion region. We used fluorescent probes to optically map the ion depletion region and the stacking of fluorescein near the nanopore/microchannel junction, and current measurements confirmed formation of the ion depletion region.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Nanoestruturas/química , Nanotecnologia/métodos , Corantes Fluorescentes/química , Íons/química , Análise de Sequência de DNA/métodos
18.
Methods Mol Biol ; 1346: 221-38, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26542725

RESUMO

Cellular heterogeneity occurs, and should be probed, at multiple levels of cellular structure and physiology from the genome to enzyme activity. In particular, single-cell measures of protein levels are complemented by single-cell measurements of the activity of these proteins. Microfluidic assays of enzyme activity at the single-cell level combine moderate to high throughput with low dead volumes and the potential for automation. Herein, we describe the steps required to fabricate and operate a microfluidic device for chemical cytometry of fluorescent or fluorogenic reporters of enzyme activity in individual cells.


Assuntos
Ensaios Enzimáticos/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Célula Única/instrumentação , Animais , Desenho de Equipamento , Tecnologia de Fibra Óptica , Fluorescência , Humanos , Lasers , Microscopia de Fluorescência , Microtecnologia
19.
Methods Enzymol ; 628: xv-xvii, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31668238
20.
Integr Biol (Camb) ; 6(2): 164-74, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24413844

RESUMO

Single-cell methodologies are revealing cellular heterogeneity in numerous biological processes and pathologies. For example, cancer cells are characterized by substantial heterogeneity in basal signaling and in response to perturbations, such as drug treatment. In this work, we examined the response of 678 individual U937 (human acute myeloid leukemia) cells to an aminopeptidase-inhibiting chemotherapeutic drug (Tosedostat) over the course of 95 days. Using a fluorescent reporter peptide and a microfluidic device, we quantified the rate of reporter degradation as a function of dose. While the single-cell measurements reflected ensemble results, they added a layer of detail by revealing unique degradation patterns and outliers within the larger population. Regression modeling of the data allowed us to quantitatively explore the relationships between reporter loading, incubation time, and drug dose on peptidase activity in individual cells. Incubation time was negatively correlated with the number of peptide fragment peaks observed, while peak area (which was proportional to reporter loading) was positively correlated with both the number of fragment peaks observed and the degradation rate. Notably, a statistically significant change in the number of peaks observed was identified as dose increased from 2 to 4 µM. Similarly, a significant difference in degradation rate as a function of reporter loading was observed for doses ≥2 µM compared to the 1 µM dose. These results suggest that additional enzymes may become inhibited at doses >1 µM and >2 µM, demonstrating the utility of single-cell data to yield novel biological hypotheses.


Assuntos
Glicina/análogos & derivados , Ácidos Hidroxâmicos/farmacologia , Leucemia Mieloide Aguda/tratamento farmacológico , Peptídeo Hidrolases/metabolismo , Inibidores de Proteases/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Glicina/administração & dosagem , Glicina/farmacologia , Humanos , Ácidos Hidroxâmicos/administração & dosagem , Leucemia Mieloide Aguda/enzimologia , Estudos Longitudinais , Microscopia de Fluorescência , Inibidores de Proteases/administração & dosagem , Análise de Regressão , Células U937
SELEÇÃO DE REFERÊNCIAS