Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 647
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39216092

RESUMO

BACKGROUND: Whether transcatheter mitral-valve repair improves outcomes in patients with heart failure and functional mitral regurgitation is uncertain. METHODS: We conducted a randomized, controlled trial involving patients with heart failure and moderate to severe functional mitral regurgitation from 30 sites in nine countries. The patients were assigned in a 1:1 ratio to either transcatheter mitral-valve repair and guideline-recommended medical therapy (device group) or medical therapy alone (control group). The three primary end points were the rate of the composite of first or recurrent hospitalization for heart failure or cardiovascular death during 24 months; the rate of first or recurrent hospitalization for heart failure during 24 months; and the change from baseline to 12 months in the score on the Kansas City Cardiomyopathy Questionnaire-Overall Summary (KCCQ-OS; scores range from 0 to 100, with higher scores indicating better health status). RESULTS: A total of 505 patients underwent randomization: 250 were assigned to the device group and 255 to the control group. At 24 months, the rate of first or recurrent hospitalization for heart failure or cardiovascular death was 37.0 events per 100 patient-years in the device group and 58.9 events per 100 patient-years in the control group (rate ratio, 0.64; 95% confidence interval [CI], 0.48 to 0.85; P = 0.002). The rate of first or recurrent hospitalization for heart failure was 26.9 events per 100 patient-years in the device group and 46.6 events per 100 patient-years in the control group (rate ratio, 0.59; 95% CI, 0.42 to 0.82; P = 0.002). The KCCQ-OS score increased by a mean (±SD) of 21.6±26.9 points in the device group and 8.0±24.5 points in the control group (mean difference, 10.9 points; 95% CI, 6.8 to 15.0; P<0.001). Device-specific safety events occurred in 4 patients (1.6%). CONCLUSIONS: Among patients with heart failure with moderate to severe functional mitral regurgitation who received medical therapy, the addition of transcatheter mitral-valve repair led to a lower rate of first or recurrent hospitalization for heart failure or cardiovascular death and a lower rate of first or recurrent hospitalization for heart failure at 24 months and better health status at 12 months than medical therapy alone. (Funded by Abbott Laboratories; RESHAPE-HF2 ClinicalTrials.gov number, NCT02444338.).

2.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-36877118

RESUMO

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
J Cardiovasc Electrophysiol ; 35(3): 547-556, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37855621

RESUMO

The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia
4.
J Cardiovasc Electrophysiol ; 35(1): 78-85, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37942843

RESUMO

INTRODUCTION: Atrio-esophageal fistula after esophageal thermal injury (ETI) is one of the most devastating complications of available energy sources for atrial fibrillation (AF) ablation. Pulsed field ablation (PFA) uses electroporation as a new energy source for catheter ablation with promising periprocedural safety advantages over existing methods due to its unique myocardial tissue sensitivity. In preclinical animal studies, a dose-dependent esophageal temperature rise has been reported. In the TESO-PFA registry intraluminal esophageal temperature (TESO) changes in a clinical setting are evaluated. METHODS: Consecutive symptomatic AF patients (62 years, 67% male, 61% paroxysmal AF, CHA2 DS2 Vasc Score 2) underwent first-time PFA and were prospectively enrolled into our registry. Eight pulse trains (2 kV/2.5 s, bipolar, biphasic, x4 basket/flower configuration each) were delivered to each pulmonary vein (PV). Two extra pulse trains per PV in flower configuration were added for wide antral circumferential ablation. Continuous intraluminal esophageal temperature (TESO) was monitored with a 12-pole temperature probe. RESULTS: Median TESO change was statistically significant and increased by 0.8 ± 0.6°C, p < .001. A TESO increase ≥ 1°C was observed in 10/43 (23%) patients. The highest TESO measured was 40.3°C. The largest TESO difference (∆TESO) was 3.7°C. All patients remained asymptomatic considering possible ETI. No atrio-esophageal fistula was reported on follow-up. CONCLUSION: A small but significant intraluminal esophageal temperature rise can be observed in most patients during PFA. TESO rise over 40°C is rare. The clinical implications of the observed findings need to be further evaluated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Veias Pulmonares , Animais , Humanos , Masculino , Feminino , Temperatura , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Frequência Cardíaca , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
6.
Circulation ; 146(11): 836-847, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-35968706

RESUMO

BACKGROUND: The randomized EAST-AFNET4 (Early Treatment of Atrial Fibrillation for Stroke Prevention Trial-Atrial Fibrillation Network) demonstrated that early rhythm control (ERC) reduces adverse cardiovascular outcomes in patients with recently diagnosed atrial fibrillation and stroke risk factors. The effectiveness and safety of ERC in patients with multiple cardiovascular comorbidities is not known. METHODS: These prespecified subanalyses of EAST-AFNET4 compared the effectiveness and safety of ERC with usual care (UC) stratified into patients with higher (CHA2DS2-VASc score ≥4) and lower comorbidity burden. Sensitivity analyses ignored sex (CHA2DS2-VA score). RESULTS: EAST-AFNET4 randomized 1093 patients with CHA2DS2-VASc score ≥4 (74.8±6.8 years, 61% female) and 1696 with CHA2DS2-VASc score <4 (67.4±8.0 years, 37% female). ERC reduced the composite primary efficacy outcome of cardiovascular death, stroke, or hospitalization for worsening of heart failure or for acute coronary syndrome in patients with CHA2DS2-VASc score ≥4 (ERC, 127/549 patients with events; UC, 183/544 patients with events; hazard ratio [HR], 0.64 [0.51-0.81]; P < 0.001) but not in patients with CHA2DS2-VASc score <4 (ERC, 122/846 patients with events; UC, 133/850 patients with events; HR, 0.93 [0.73-1.19]; P=0.56, Pinteraction=0.037). The primary safety outcome (death, stroke, or serious adverse events of rhythm control therapy) was not different between study groups in patients with CHA2DS2-VASc score ≥4 (ERC, 112/549 patients with events; UC, 132/544 patients with events; HR, 0.84 [0.65, 1.08]; P=0.175), but occurred more often in patients with CHA2DS2-VASc scores <4 randomized to ERC (ERC, 119/846 patients with events; UC, 91/850 patients with events; HR, 1.39 [1.05-1.82]; P=0.019, Pinteraction=0.008). Life-threatening events or death were not different between groups (CHA2DS2-VASc score ≥4, ERC, 84/549 patients with event, UC, 96/544 patients with event; CHA2DS2-VASc scores <4, ERC, 75/846 patients with event, UC, 73/850 patients with event). When female sex was ignored for the creation of higher and lower risk groups (CHA2DS2-VA score), the Pinteraction was not significant for the primary efficacy outcome (P=0.25), but remained significant (P=0.044) for the primary safety outcome. CONCLUSIONS: Patients with recently diagnosed atrial fibrillation and CHA2DS2-VASc score ≥4 should be considered for ERC to reduce cardiovascular outcomes, whereas those with fewer comorbidities may have less favorable outcomes with ERC. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01288352. URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2010-021258-20. URL: https://www.isrctn.com/; Unique identifier: ISRCTN04708680.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Comorbidade , Feminino , Humanos , Masculino , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
7.
N Engl J Med ; 383(14): 1305-1316, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865375

RESUMO

BACKGROUND: Despite improvements in the management of atrial fibrillation, patients with this condition remain at increased risk for cardiovascular complications. It is unclear whether early rhythm-control therapy can reduce this risk. METHODS: In this international, investigator-initiated, parallel-group, open, blinded-outcome-assessment trial, we randomly assigned patients who had early atrial fibrillation (diagnosed ≤1 year before enrollment) and cardiovascular conditions to receive either early rhythm control or usual care. Early rhythm control included treatment with antiarrhythmic drugs or atrial fibrillation ablation after randomization. Usual care limited rhythm control to the management of atrial fibrillation-related symptoms. The first primary outcome was a composite of death from cardiovascular causes, stroke, or hospitalization with worsening of heart failure or acute coronary syndrome; the second primary outcome was the number of nights spent in the hospital per year. The primary safety outcome was a composite of death, stroke, or serious adverse events related to rhythm-control therapy. Secondary outcomes, including symptoms and left ventricular function, were also evaluated. RESULTS: In 135 centers, 2789 patients with early atrial fibrillation (median time since diagnosis, 36 days) underwent randomization. The trial was stopped for efficacy at the third interim analysis after a median of 5.1 years of follow-up per patient. A first-primary-outcome event occurred in 249 of the patients assigned to early rhythm control (3.9 per 100 person-years) and in 316 patients assigned to usual care (5.0 per 100 person-years) (hazard ratio, 0.79; 96% confidence interval, 0.66 to 0.94; P = 0.005). The mean (±SD) number of nights spent in the hospital did not differ significantly between the groups (5.8±21.9 and 5.1±15.5 days per year, respectively; P = 0.23). The percentage of patients with a primary safety outcome event did not differ significantly between the groups; serious adverse events related to rhythm-control therapy occurred in 4.9% of the patients assigned to early rhythm control and 1.4% of the patients assigned to usual care. Symptoms and left ventricular function at 2 years did not differ significantly between the groups. CONCLUSIONS: Early rhythm-control therapy was associated with a lower risk of adverse cardiovascular outcomes than usual care among patients with early atrial fibrillation and cardiovascular conditions. (Funded by the German Ministry of Education and Research and others; EAST-AFNET 4 ISRCTN number, ISRCTN04708680; ClinicalTrials.gov number, NCT01288352; EudraCT number, 2010-021258-20.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Doenças Cardiovasculares/prevenção & controle , Ablação por Cateter , Síndrome Coronariana Aguda/epidemiologia , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/complicações , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Tempo de Internação , Masculino , Risco , Prevenção Secundária , Método Simples-Cego , Função Ventricular Esquerda/efeitos dos fármacos
8.
J Cardiovasc Electrophysiol ; 34(10): 2029-2039, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37681996

RESUMO

INTRODUCTION: Cryoballoon ablation (CBA) aiming at pulmonary vein isolation (PVI) became a standardized atrial fibrillation (AF) ablation procedure. Life-threatening complications like cardiac tamponade exist. Intracardiac echocardiography (ICE) usage is associated with superior safety in radiofrequency ablation. It is unclear if ICE has an impact on safety of CBA. METHODS: The FREEZE Cohort (NCT01360008) subanalysis included patients undergoing "PVI only" CBA. Patients with intraprocedural transesophageal echocardiography were excluded. Group A comprises conventional, group B ICE-guided CBA. Periprocedural results were compared. RESULTS: From 2011 to 2016, a total of 4189 patients were enrolled, and 1906 (45.5%) were included in this subanalysis, split up in two groups (A: 1066 [55.9%], B: 840 [44.1%]). Group A was younger (60.6 ± 10.8 vs. 62.4 ± 10.5 years, p < .001), with smaller left atria (41 vs. 43 mm, p < .001), and less persistent AF (23.1 vs. 38.1%, p < .001). Procedure, left atrial, and fluoroscopy times were shorter in group A as compared to group B. Dose area product was significantly higher in group A (2911 vs. 2072 cGyxcm2 , p < .001). In-hospital major adverse cerebrovascular and cardiac event rates including two deaths in group A were not different between groups (0.5% vs. 0.1%, p = .18). The rate of total procedural (10.4% vs. 5.1%, p < .001) and major complications (3.2% vs. 1.3%, p < .001) was significantly higher in group A. Cardiac tamponade occurred significantly more frequently in group A (8 [0.8%] vs. 1 [0.1%], p = .046). Independent predictors for major complications were female sex (odds ratio [OR] 2.03, p = .03) and non-ICE usage (OR 2.38, p = .02). No differences were observed for persistent phrenic nerve palsy, nor for groin complications. CONCLUSION: CBA was significantly safer and required less radiation if ICE was used, although the procedures were more complex. The risk of groin complications was not increased with ICE usage. Non-ICE usage was the only modifiable independent predictor of major complications.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos de Coortes , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Estudos Prospectivos
9.
Catheter Cardiovasc Interv ; 101(3): 610-619, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36682074

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). OAC treatment has been proven feasible in mild-to-moderate chronic kidney disease (CKD). In contrast, the optimal antithrombotic management of AF patients with end-stage renal disease (ESRD) is unknown and LAAC has not been proven in these patients in prospective randomized clinical trials. OBJECTIVES: The objective of this study is to evaluate safety and efficacy of LAAC in patients with ESRD. METHODS: Patients undergoing LAAC were collected in a German multicenter real-world observational registry. A composite endpoint consisting of the occurrence of ischemic stroke/transient ischemic attack, systemic embolism, and/or major clinical bleeding was assessed. Patients with ESRD were compared with propensity score-matched patients without severe CKD. ESRD was defined as a glomerular filtration rate < 15 ml/min/1.73 m2 or chronic hemodialysis treatment. RESULTS: A total of 604 patients were analyzed, including 57 with ESRD and 57 propensity-matched patients. Overall, 596 endocardial and 8 epicardial LAAC procedures were performed. Frequency of major complications was 7.0% (42/604 patients) in the overall cohort, 8.8% (5/57 patients) in patients with ESRD, and 10.5% (6/57 patients) in matched controls (p = 0.75). The estimated event-free survival of the combined endpoint after 500 days was 90.7 ± 4.5% in patients with ESRD and 90.2 ± 5.5% in matched controls (p = 0.33). CONCLUSIONS: LAAC had comparable procedural safety and clinical efficacy in patients with ESRD and patients without severe CKD.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Falência Renal Crônica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Estudos Prospectivos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Sistema de Registros , Anticoagulantes/efeitos adversos
10.
Europace ; 25(3): 880-888, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36546582

RESUMO

AIMS: The very high-power short-duration (vHP-SD) radiofrequency (RF) ablation concept of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective, and faster procedures. Utilizing conventional ablation, the 'close protocol' has been verified. Since lesion formation of vHP-SD ablation creates wider but shallower lesions we adapted the close protocol to an individualized and tighter 'very-close protocol' of 3-4 mm of inter-lesion distance (ILD) at the anterior and 5-6 mm at the posterior aspect of the left atrium using vHP-SD only. Here, we evaluated the safety and efficacy of vHP-SD ablation for PVI utilizing a very-close protocol in comparison with standard ablation. METHODS AND RESULTS: A total of 50 consecutive patients with symptomatic AF were treated with a very-close protocol utilizing vHP-SD (vHP-SD group). The data were compared with 50 consecutive patients treated by the ablation-index-guided strategy (control group). The mean RF time was 352 ± 81 s (vHP-SD) and 1657 ± 570 s (control, P < 0.0001), and the mean procedure duration was 59 ± 13 (vHP-SD) and 101 ± 38 (control, P < 0.0001). The first-pass isolation rate was 74% (vHP-SD) and 76% (control, P = 0.817). Severe adverse events were reported in 1 (2%, vHP-SD) and 3 (6%, control) patients (P = 0.307). A 12-month recurrence-free survival was 78% (vHP-SD) and 64% (control, P = 0.142). PVI durability assessed during redo-procedures was 75% (vHP-SD) vs. 33% (control, P < 0.001). CONCLUSIONS: PVI solely utilizing vHP-SD via a very-close protocol provides safe and effective procedures with a high rate of first-pass isolations. The procedure duration and ablation time were remarkably low. A 12-month follow-up and PVI durability are promising.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/cirurgia , Resultado do Tratamento
11.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37589146

RESUMO

AIMS: Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS: A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION: The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


Assuntos
Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Lactente , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Temperatura
12.
Europace ; 25(1): 130-136, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36006798

RESUMO

AIMS: The incidence of in-hospital post-interventional complications and mortality after ablation of supraventricular tachycardia (SVT) vary among the type of procedure and most likely the experience of the centre. As ablation therapy of SVT is progressively being established as first-line therapy, further assessment of post-procedural complication rates is crucial for health care quality. METHODS AND RESULTS: We aimed at determining the incidence of in-hospital mortality and bleeding complications from SVT ablations in German high-volume electrophysiological centres between 2005 and 2020. All cases were registered by the German Diagnosis Related Groups-and the German Operation and Procedure Classification (OPS) system. A uniform search for SVT ablations from 2005 to 2020 with the same OPS codes defining the type of ablation/arrhythmia as well as the presence of a vascular complication, cardiac tamponade, and/or in-hospital death was performed. An overall of 47 610 ablations with 10 037 SVT ablations were registered from 2005 to 2020 among three high-volume centres. An overall complication rate of 0.5% (n = 38) was found [median age, 64; ±15 years; female n = 26 (68%)]. All-cause mortality was 0.02% (n = 2) and both patients had major prior co-morbidities precipitating a lethal outcome irrespective of the ablation procedure. Vascular complications occurred in 10 patients (0.1%), and cardiac tamponade was detected in 26 cases (0.3%). CONCLUSION: The present case-based analysis shows an overall low incidence of in-hospital complications after SVT ablation highlighting the overall very good safety profile of SVT ablations in high-volume centres. Further prospective analysis is still warranted to guarantee continuous quality control and optimal patient care.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Mortalidade Hospitalar , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
13.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38102318

RESUMO

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Taquicardia Ventricular , Humanos , Mortalidade Hospitalar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Hospitais , Acidente Vascular Cerebral/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
14.
Europace ; 25(2): 374-381, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36414239

RESUMO

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Nervo Frênico , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
15.
Circ J ; 87(12): 1722-1726, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37532529

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal energy source with promising safety and efficacy advantages. We aimed to develop a convenient, safe, effective and fast method of pulmonary vein isolation (PVI) utilizing a penta-spline PFA catheter via a single femoral vein and a venous closure system.Methods and Results: Consecutive patients (n=50; mean age: 63.6±10.7 years, 38% female) presenting with AF (paroxysmal AF: 56%) underwent first-time PVI via PFA. A single ultrasound-guided femoral vein puncture and a single transseptal puncture were used. After PVI using the penta-spline PFA catheter, extra pulse trains were added to the posterior wall for wide antral circumferential ablation. A venous closure system was used and a Donati suture was performed. The pressure bandage was removed after 1 h. A total of 196 PVs were identified and isolated with PFA only. The mean procedural time was 27.4±6.6 min, and the mean dwelling time was 14.4±5.5 min. Time to ambulation was 3.3±3.1 h. No severe complications occurred. During a mean follow-up of 6.5±2.1 months, 41/50 patients (82%) remained in sinus rhythm. CONCLUSIONS: The combination of a single venous puncture, single transseptal puncture approach using PFA and vascular closure device resulted in a 100% rate of acute PVI and an extraordinarily fast procedure and time to ambulation. The rate of periprocedural complications was low.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Catéteres
16.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
17.
Pacing Clin Electrophysiol ; 46(1): 11-19, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36356298

RESUMO

BACKGROUND: Catheter ablation has been evolved to a cornerstone in the therapy of atrial fibrillation (AF); however, atrial tachycardias (AT) after AF ablation are still an important issue. Besides the electrical recurrence of atrial tachyarrhythmia after ablation, left atrial (LA) remodeling has received attention as a consequence of AF. OBJECTIVE: The aim of this study is to evaluate predictors for AT recurrence and LA remodeling in patients with repeat AF ablation procedures. METHODS AND RESULTS: One hundred thirteen patients who underwent repeat AF ablation with 3D electro-anatomical mapping system were evaluated. Mean age was 63.1 ± 9.3 years, and 2.3 ± 0.5 ablation procedures were performed during a time period of 22 [IQR 7;48] months. Reverse structural LA remodeling (LA volume decreased more than 15%) was observed in 25 (22.1%) patients. LA volume index (LAVI) during first procedure was the only predictor for positive reverse structural LA remodeling (hazard ratio (HR): 1.03, 95% CI: 1.00-1.07, p = .036) in multivariate analysis. Fifty-nine (52.2%) patients experienced only AF and 54 (47.8%) patients AT after first procedure. Female gender (HR: 5.21, 95% CI: 1.66-18.08, p = .006), LAVI (HR: 1.06, 95% CI: 1.02-1.11, p = .008) and LA scar percentage (HR: 1.08, 95% CI: 1.02-1.17, p = .019) were independent significant predictors for AT recurrence in multivariate analysis. CONCLUSIONS: Reverse structural LA remodeling occurred in a quarter of patients with repeat ablation procedures for AF. Only larger LAVI during first procedure predicted reverse structural LA remodeling. Half of the patients experienced AT between first and last ablation procedure. Female gender, larger LAVI and larger scar area were significant predictors for AT after catheter ablation for AF.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Cicatriz , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
18.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36588339

RESUMO

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Recidiva , Átrios do Coração , Resultado do Tratamento , Ablação por Cateter/métodos
19.
Herz ; 48(3): 212-217, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37277617

RESUMO

Arrhythmic manifestations of COVID-19 include atrial arrhythmias such as atrial fibrillation or atrial flutter, sinus node dysfunction, atrioventricular conduction abnormalities, ventricular tachyarrhythmias, sudden cardiac arrest, and cardiovascular dysautonomias including the so-called long COVID syndrome. Various pathophysiological mechanisms have been implicated, such as direct viral invasion, hypoxemia, local and systemic inflammation, changes in ion channel physiology, immune activation, and autonomic dysregulation. The development of atrial or ventricular arrhythmias in hospitalized COVID-19 patients has been shown to portend a higher risk of in-hospital death. Management of these arrhythmias should be based on published evidence-based guidelines, with special consideration of the acuity of COVID-19 infection, concomitant use of antimicrobial and anti-inflammatory drugs, and the transient nature of some rhythm disorders. In view of new SARS-CoV­2 variants that may evolve, the development and use of newer antiviral and immunomodulator drugs, and the increasing adoption of vaccination, clinicians must remain vigilant for other arrhythmic manifestations that may occur in association with this novel but potentially deadly disease.


Assuntos
Fibrilação Atrial , COVID-19 , Humanos , Incidência , Síndrome de COVID-19 Pós-Aguda , Mortalidade Hospitalar , SARS-CoV-2 , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
20.
Herz ; 48(4): 292-300, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35397659

RESUMO

BACKGROUND: Polymer-free and carrier-free drug-coated stents (DCS) represent a novel therapeutic option for the treatment of coronary artery disease. The objective of this pilot registry is to evaluate the safety and efficacy of DCS implantation in bifurcation lesions. METHODS: Overall, 23 consecutive patients with 24 lesions received a Biolimus A9-coated DCS for coronary bifurcation lesions. Patients were examined with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 3-6 months of follow-up. RESULTS: A total of 23 patients with 24 bifurcation lesions were included in this study. Nine (33.3%) lesions of eight patients revealed angiographical target lesion failure due to in-stent restenosis (ISR). In total, 19 patients with 20 bifurcation lesions were suitable for OCT analysis. A total of 2936 struts were analyzed and 14 struts (0.47%) were classified as malapposed. The mean luminal area (mm2) was not different in lesions with ISR vs. lesions with no ISR (5.07 ± 2.0 vs. 5.73 ± 1.34, p = 0.39) at follow-up. Lesions with ISR showed higher mean neointimal burden (27.11 ± 10.59 vs. 13.93 ± 9.16%, respectively; p = 0.009). All of the patients who presented with significant ISR required percutaneous re-intervention. CONCLUSIONS: We observed a high rate of DCS ISR in bifurcation lesions, possibly related to increased inflammation and neoatherosclerosis. The small size of the study warrants careful interpretation of our results. Larger trials are necessary to expand knowledge of these findings.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Tomografia de Coerência Óptica , Vasos Coronários , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária , Sistema de Registros , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA