Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cell Rep Methods ; 3(3): 100419, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-37056378

RESUMO

Light microscopy is a powerful single-cell technique that allows for quantitative spatial information at subcellular resolution. However, unlike flow cytometry and single-cell sequencing techniques, microscopy has issues achieving high-quality population-wide sample characterization while maintaining high resolution. Here, we present a general framework, data-driven microscopy (DDM) that uses real-time population-wide object characterization to enable data-driven high-fidelity imaging of relevant phenotypes based on the population context. DDM combines data-independent and data-dependent steps to synergistically enhance data acquired using different imaging modalities. As a proof of concept, we develop and apply DDM with plugins for improved high-content screening and live adaptive microscopy for cell migration and infection studies that capture events of interest, rare or common, with high precision and resolution. We propose that DDM can reduce human bias, increase reproducibility, and place single-cell characteristics in the context of the sample population when interpreting microscopy data, leading to an increase in overall data fidelity.


Assuntos
Microscopia , Humanos , Microscopia/métodos , Reprodutibilidade dos Testes
2.
Elife ; 112022 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-35200140

RESUMO

Antibody binding to cell surface proteins plays a crucial role in immunity, and the location of an epitope can altogether determine the immunological outcome of a host-target interaction. Techniques available today for epitope identification are costly, time-consuming, and unsuited for high-throughput analysis. Fast and efficient screening of epitope location can be useful for the development of therapeutic monoclonal antibodies and vaccines. Cellular morphology typically varies, and antibodies often bind heterogeneously across a cell surface, making traditional particle-averaging strategies challenging for accurate native antibody localization. In the present work, we have developed a method, SiteLoc, for imaging-based molecular localization on cellular surface proteins. Nanometer-scale resolution is achieved through localization in one dimension, namely, the distance from a bound ligand to a reference surface. This is done by using topological image averaging. Our results show that this method is well suited for antibody binding site measurements on native cell surface morphology and that it can be applied to other molecular distance estimations as well.


Antibodies play a key role in the immune system. These proteins stick to harmful substances, such as bacteria and other disease-causing pathogens, marking them for destruction or blocking their attack. Antibodies are highly selective, and this ability has been used to target particular molecules in research, diagnostics and therapies. Typically, antibodies need to stick to a particular segment, or 'epitope', on the surface of a cell in order to trigger an immune response. Knowing where these regions are can help explain how these immune proteins work and aid the development of more effective drugs and diagnostic tools. One way to identify these sites is to measure the nano-distance between antibodies and other features on the cell surface. To do this, researchers take multiple images of the cell the antibody is attached to using light microscopy. Various statistical methods are then applied to create an 'average image' that has a higher resolution and can therefore be used to measure the distance between these two points more accurately. While this approach works on fixed shapes, like a perfect circle, it cannot handle human cells and bacteria which are less uniform and have more complex surfaces. Here, Kumra Ahnlide et al. have developed a new method called SiteLoc which can overcome this barrier. The method involves two fluorescent probes: one attached to a specific site on the cell's surface, and the other to the antibody or another molecule of interest. These two probes emit different colours when imaged with a fluorescent microscope. To cope with objects that have uneven surfaces, such as cells and bacteria, the two signals are transformed to 'follow' the same geometrical shape. The relative distance between them is then measured using statistical methods. Using this approach, Kumra Ahnlide et al. were able to identify epitopes on a bacterium, and measure distances on the surface of human red blood cells. The SiteLoc system could make it easier to develop antibody-based treatments and diagnostic tools. Furthermore, it could also be beneficial to the wider research community who could use it to probe other questions that require measuring nanoscale distances.


Assuntos
Anticorpos Monoclonais/metabolismo , Sítios de Ligação de Anticorpos , Membrana Celular/metabolismo , Mapeamento de Epitopos/métodos , Proteínas de Membrana/metabolismo , Sítios de Ligação , Membrana Celular/imunologia , Epitopos/metabolismo , Humanos , Ligantes , Proteínas de Membrana/imunologia , Modelos Moleculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA