Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Pediatr Res ; 95(1): 93-101, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37087539

RESUMO

BACKGROUND: Clinical translation of the extracorporeal artificial placenta (AP) is impeded by the high risk for intracranial hemorrhage in extremely premature newborns. The Nitric Oxide Surface Anticoagulation (NOSA) system is a novel non-thrombogenic extracorporeal circuit. This study aims to test the NOSA system in the AP without systemic anticoagulation. METHODS: Ten extremely premature lambs were delivered and connected to the AP. For the NOSA group, the circuit was coated with DBHD-N2O2/argatroban, 100 ppm nitric oxide was blended into the sweep gas, and no systemic anticoagulation was given. For the Heparin control group, a non-coated circuit was used and systemic anticoagulation was administered. RESULTS: Animals survived 6.8 ± 0.6 days with normal hemodynamics and gas exchange. Neither group had any hemorrhagic or thrombotic complications. ACT (194 ± 53 vs. 261 ± 86 s; p < 0.001) and aPTT (39 ± 7 vs. 69 ± 23 s; p < 0.001) were significantly lower in the NOSA group than the Heparin group. Platelet and leukocyte activation did not differ significantly from baseline in the NOSA group. Methemoglobin was 3.2 ± 1.1% in the NOSA group compared to 1.6 ± 0.6% in the Heparin group (p < 0.001). CONCLUSIONS: The AP with the NOSA system successfully supported extremely premature lambs for 7 days without significant bleeding or thrombosis. IMPACT: The Nitric Oxide Surface Anticoagulation (NOSA) system provides effective circuit-based anticoagulation in a fetal sheep model of the extracorporeal artificial placenta (AP) for 7 days. The NOSA system is the first non-thrombogenic circuit to consistently obviate the need for systemic anticoagulation in an extracorporeal circuit for up to 7 days. The NOSA system may allow the AP to be implemented clinically without systemic anticoagulation, thus greatly reducing the intracranial hemorrhage risk for extremely low gestational age newborns. The NOSA system could potentially be applied to any form of extracorporeal life support to reduce or avoid systemic anticoagulation.


Assuntos
Oxigenação por Membrana Extracorpórea , Nascimento Prematuro , Trombose , Gravidez , Humanos , Feminino , Ovinos , Animais , Óxido Nítrico , Placenta/fisiologia , Heparina , Hemorragia/complicações , Trombose/prevenção & controle , Anticoagulantes/farmacologia , Hemorragias Intracranianas/complicações
2.
J Pediatr Surg ; 59(1): 103-108, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37858393

RESUMO

BACKGROUND: Children with end-stage lung disease are commonly managed with extracorporeal life support (ECLS) as a bridge to lung transplantation. A pumpless artificial lung (MLung) is a portable alternative to ECLS and it allows for ambulation. Both ECLS and pumpless artificial lungs require systemic anticoagulation which is associated with hemorrhagic complications. We tested the MLung with a novel Nitric Oxide (NO) Surface Anticoagulation (NOSA) system, to provide local anticoagulation for 72 h of support in a pediatric-size ovine model. METHODS: Four mini sheep underwent thoracotomy and cannulation of the pulmonary artery (inflow) and left atrium (outflow), recovered and were monitored for 72hr. The circuit tubing and connectors were coated with the combination of an NO donor (diazeniumdiolated dibutylhexanediamine; DBHD-N2O2) and argatroban. The animals were connected to the MLung and 100 ppm of NO was added to the sweep gas. Systemic hemodynamics, blood chemistry, blood gases, and methemoglobin were collected. RESULTS: Mean device flow was 836 ± 121 mL/min. Device outlet saturation was 97 ± 4%. Pressure drop across the lung was 3.5 ± 1.5 mmHg and resistance was 4.3 ± 1.7 mmHg/L/min. Activated clotting time averaged 170 ± 45s. Methemoglobin was 2.9 ± 0.8%. Platelets declined from 590 ± 101 at baseline to 160 ± 90 at 72 h. NO flux (x10-10 mol/min/cm2) of the NOSA circuit averaged 2.8 ± 0.6 (before study) and 1.9 ± 0.1 (72 h) and across the MLung 18 ± 3 NO flux was delivered. CONCLUSION: The MLung is a more portable form of ECLS that demonstrates effective gas exchange for 72 h without hemodynamic changes. Additionally, the NOSA system successfully maintained local anticoagulation without evidence of systemic effects.


Assuntos
Oxigenação por Membrana Extracorpórea , Óxido Nítrico , Animais , Humanos , Ovinos , Criança , Metemoglobina , Pulmão , Hemodinâmica , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico
3.
ASAIO J ; 69(7): e301-e307, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37146595

RESUMO

Portable artificial lung (AL) systems are under development, but there are few technologies available that adjust the carbon dioxide (CO 2 ) removal in response to changes in patient metabolic needs. Our work describes the second generation of a CO 2 -based portable servoregulation system that automatically adjusts CO 2 removal in ALs. Four adult sheep (68 ± 14.3 kg) were used to test the servoregulator. The servoregulator controlled air sweep flow through the lung to meet a target exhaust gas CO 2 (tEGCO 2 ) level in normocapnic and hypercapnic (arterial partial pressure of CO 2 [PaCO 2 ] >60 mm Hg) conditions at varying flow rates (0.5-1.5 L/min) and at tEGCO 2 levels of 10, 20, and 40 mm Hg. In hypercapnic sheep, average post-AL blood partial pressure of CO 2 (pCO 2 ) values were 22.4 ± 3.6 mm Hg for tEGCO 2 of 10 mm Hg, 28.0 ± 4.1 mm Hg for tEGCO 2 of 20 mm Hg and 40.6 ± 4.8 mm Hg for tEGCO 2 of 40 mm Hg. The controller successfully and automatically adjusted the sweep gas flow to rapidly (<10 minutes) meet the tEGCO 2 level when challenged with changes in inlet blood flow or target EGCO 2 levels for all animals. These in vivo data demonstrate an important step toward portable ALs that can automatically modulate CO 2 removal and allow for substantial changes in patient activity or disease status in ambulatory applications.


Assuntos
Oxigenação por Membrana Extracorpórea , Hemodinâmica , Animais , Ovinos , Dióxido de Carbono , Hipercapnia , Pulmão/metabolismo
4.
ASAIO J ; 68(10): 1282-1289, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36194099

RESUMO

Currently, normothermic ex vivo heart perfusion (NEVHP) is limited to 6-12 hours. NEVHP for 24 hours or more would allow organ treatment, assessment of organ function, and near-perfect recipient matching. We present a model of NEVHP using continuous hemofiltration (HFn) with sustained myocardial viability up to 24 hours. Twenty hearts from 6-10 kg piglets were procured and maintained on our NEVHP circuit. HFn hearts (n = 10) underwent NEVHP with HFn, whereas controls (n = 10) used NEVHP alone. All HFn vs. four controls were viable at 24 h (p = 0.004). At end perfusion, HFn hearts had higher left ventricular systolic pressure (51.5 ± 6.8 mm Hg, 38.3 ± 5.2 mm Hg, p = 0.05), lower coronary resistance (0.83 ± 0.11 mm Hg/mL/min, 1.18 ± 0.21mmHg/mL/min, p < 0.05), and lower serum lactate levels (2.9 ± 0.4 mmol/L, 4.1 ± 0.6 mmol/L, p < 0.0001) when compared to control hearts. HFn hearts also had less extensive myocardial damage and significantly less edema than control hearts with lower weight gain and wet-dry ratios. Using our circuit, NEVHP for 24 hours is possible with HFn and allows for preservation of myocardial function, improved tissue viability, decreased tissue edema, and less myocardial injury.


Assuntos
Transplante de Coração , Hemofiltração , Animais , Edema , Coração , Lactatos , Miocárdio , Preservação de Órgãos , Perfusão , Suínos
5.
J Pediatr Surg ; 57(1): 26-33, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34649727

RESUMO

BACKGROUND: Artificial lungs have the potential to serve as a bridge to transplantation or recovery for children with end-stage lung disease dependent on extracorporeal life support, but such devices currently require systemic anticoagulation. We describe our experience using the novel Nitric Oxide (NO) Surface Anticoagulation (NOSA) system-an NO-releasing circuit with NO in the sweep gas-with the Pediatric MLung-a low-resistance, pumpless artificial lung. METHODS: NO flux testing: MLungs (n = 4) were tested using veno-venous extracorporeal life support in a sheep under anesthesia with blood flow set to 0.5 and 1 L/min and sweep gas blended with 100 ppm NO at 1, 2, and 4 L/min. NO and NO2 were measured in the sweep and exhaust gas to calculate NO flux across the MLung membrane. Pumpless implants: Sheep (20-100 kg, n = 3) underwent thoracotomy and cannulation via the pulmonary artery (device inflow) and left atrium (device outflow) using cannulae and circuit components coated with an NO donor (diazeniumdiolated dibutylhexanediamine; DBHD-N2O2) and argatroban. Animals were connected to the MLung with 100 ppm NO in the sweep gas under anesthesia for 24 h with no systemic anticoagulation after cannulation. RESULTS: NO flux testing: NO flux averaged 3.4 ± 1.0 flux units (x10-10 mol/cm2/min) (human vascular endothelium: 0.5-4 flux units). Pumpless implants: 3 sheep survived 24 h with patent circuits. MLung blood flow was 716 ± 227 mL/min. Outlet oxygen saturation was 98.3 ± 2.6%. Activated clotting time was 151±24 s. Platelet count declined from 334,333 ± 112,225 to 123,667 ± 7,637 over 24 h. Plasma free hemoglobin and leukocyte and platelet activation did not significantly change. CONCLUSIONS: The NOSA system provides NO flux across a gas-exchange membrane of a pumpless artificial lung at a similar rate as native vascular endothelium and achieves effective local anticoagulation of an artificial lung circuit for 24 h.


Assuntos
Oxigenação por Membrana Extracorpórea , Óxido Nítrico , Animais , Anticoagulantes , Criança , Humanos , Pulmão , Saturação de Oxigênio , Ovinos
6.
ASAIO J ; 66(7): 818-824, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31425266

RESUMO

Cardiopulmonary bypass causes a systemic inflammatory response reaction that may contribute to postoperative complications. One cause relates to the air/blood interface from the extracorporeal circuit. The modulatory effects of blending nitric oxide (NO) gas into the ventilation/sweep gas of the membrane lung was studied in a porcine model of air-induced inflammation in which NO gas was added and compared with controls with or without an air/blood interface. Healthy swine were supported on partial bypass under four different test conditions. Group 1: no air exposure, group 2: air alone, group 3: air plus 50 ppm NO, and group 4: air plus 500 ppm NO. The NO gas was blended into the ventilation/sweep site of the membrane lung. The platelets and leucocytes were activated by air alone. Addition of NO to the sweep gas attenuated the inflammatory response created by the air/blood interface in this model.


Assuntos
Plaquetas/efeitos dos fármacos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/métodos , Óxido Nítrico/farmacologia , Animais , Humanos , Inflamação/etiologia , Suínos
7.
ASAIO J ; 66(7): 753-759, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31453833

RESUMO

Preservation of a donor heart for transplantation is limited to 6-8 hours. Based on our demonstration of 12 hour perfusion with plasma cross circulation, this study aimed to evaluate ex vivo heart perfusion (EVHP) for up to 72 hours using cross plasma circulation (XC-plasma) from a live, awake paracorporeal sheep (PCS). Six ovine hearts were perfused for 72 hours using plasma cross circulation at a rate of 1 L/min with a live, awake PCS. Controls were seven perfused hearts without cross circulation. Experiments were electively ended at 72 hours, and epinephrine (0.1 mg) was delivered to demonstrate hormonal responsiveness. All controls failed at 6-10 hours. All six hearts perfused for 72 hours maintained normal heart function, metabolism, and responsiveness to epinephrine. Blood gases, electrolytes, and lactate levels were normal and stable throughout the study. All hearts appeared suitable for transplantation. We have demonstrated successful normothermic EVHP for 72 hours.


Assuntos
Circulação Cruzada/métodos , Transplante de Coração , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Circulação Extracorpórea/métodos , Ovinos
8.
ASAIO J ; 66(7): 796-802, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31577624

RESUMO

The modalities of vascular access for the extracorporeal artificial placenta (AP) have undergone many iterations over the past decade. We hypothesized that single lumen cannulation (SLC) of the jugular vein using tidal flow extracorporeal life (ECLS) support is a feasible alternative to venovenous (VV) umbilical-jugular cannulation and double lumen cannulation (DLC) and can maintain fetal circulation, stable hemodynamics, and adequate gas exchange for 24 hours. After in vitro evaluation of the tidal flow system, six preterm lambs at estimated gestational age 118-124 days (term 145 days) were delivered and underwent VV-ECLS. Three were supported using DLC and three with SLC utilizing tidal flow AP support. Hemodynamics, circuit flow, and gas exchange were monitored. Target fetal parameters were as follows: mean arterial pressure 40-60 mmHg, heart rate 140-240 beats per minute (bpm), SatO2% 60-80%, PaO2 25-50 mmHg, PaCO2 30-55 mmHg, oxygen delivery >5 ml O2/dl/kg/min, and circuit flow 100 ± 25 ml/kg/min. All animals survived 24 hours and maintained fetal circulation with stable hemodynamics and adequate gas exchange. Parameters of the tidal flow group were comparable with those of DLC. Single lumen jugular cannulation using tidal flow is a promising vascular access strategy for AP support. Successful miniaturization holds great potential for clinical translation to support extremely premature infants.


Assuntos
Órgãos Artificiais , Circulação Extracorpórea/métodos , Placenta , Animais , Animais Recém-Nascidos , Circulação Extracorpórea/instrumentação , Feminino , Feto , Hemodinâmica/fisiologia , Perfusão/instrumentação , Perfusão/métodos , Gravidez , Ovinos , Carneiro Doméstico
9.
Sports (Basel) ; 7(8)2019 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-31362349

RESUMO

The potential association between running foot strike analysis and performance and injury metrics has created the need for reliable methods to quantify foot strike pattern outside the laboratory. Small, wireless inertial measurement units (IMUs) allow for unrestricted movement of the participants. Current IMU methods to measure foot strike pattern places small, rigid accelerometers and/or gyroscopes on the heel cap or on the instep of the shoe. The purpose of this study was to validate a thin, conformable IMU sensor placed directly on the dorsal foot surface to determine foot strike angles and pattern. Participants (n = 12) ran on a treadmill with different foot strike patterns while videography and sensor data were captured. Sensor measures were compared against traditional 2D video analysis techniques and the results showed that the sensor was able to accurately (92.2% success) distinguish between rearfoot and non-rearfoot foot strikes using an angular velocity cut-off value of 0°/s. There was also a strong and significant correlation between sensor determined foot strike angle and foot strike angle determined from videography analysis (r = 0.868, p < 0.001), although linear regression analysis showed that the sensor underestimated the foot strike angle. Conformable sensors with the ability to attach directly to the human skin could improve the tracking of human dynamics and should be further explored.

10.
J Am Med Inform Assoc ; 14(2): 175-81, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17213499

RESUMO

Developments in information technology offer new opportunities to design electronic patient record systems (EPR) which integrate a broad range of functions such as clinical decision support, order entry, or electronic alerts. It has been recently suggested that EPR could support new applications for disease surveillance and patient safety. We describe the integration of a voluntary incident reporting system into an EPR used in operating theatres, to allow the reporting of accidents and preventable complications. We assessed system's reliability and users' acceptance. During the 4-years observation period (2002-2006), 48,983 interventional procedures were performed. Clinicians documented 85.1% of procedures on the incident reporting form. Agreement between chart review and electronically reported incidents was 80.6%. The integration of an incident reporting system into an EPR is reliable and well supported by health care professionals.


Assuntos
Sistemas Computadorizados de Registros Médicos/organização & administração , Gestão de Riscos/organização & administração , Adulto , Idoso , Atitude do Pessoal de Saúde , Sistemas de Informação Hospitalar/organização & administração , Humanos , Sistemas Computadorizados de Registros Médicos/estatística & dados numéricos , Pessoa de Meia-Idade , Salas Cirúrgicas/organização & administração , Gestão de Riscos/estatística & dados numéricos , Integração de Sistemas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA