Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Appl Microbiol Biotechnol ; 98(4): 1795-805, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24362855

RESUMO

This work explores the use of the phage P22 in a phagomagnetic immunoassay for the rapid detection of Salmonella. The covalent attachment of wild-type phages was performed on two different magnetic carriers: carboxyl-activated magnetic nanoparticles (300 nm) and tosyl-activated magnetic microparticles (2.8 µm). The bacteria were captured and preconcentrated by the phage-modified magnetic particles, followed by the detection using specific anti-Salmonella antibodies conjugated to horseradish peroxidase as an optical reporter. Outstanding selectivity and sensitivity was obtained with this approach, achieving detection limits of 19 CFU mL(-1) in 2.5 h without any pre-enrichment, in milk samples. Moreover, if the samples were pre-enriched for 6 h, the method was able to detect as low as 1.4 CFU in 25 mL of milk. Therefore, the proposed strategy based on the combined use of phagomagnetic separation with immunological labeling is promising as a rapid and simple method for food safety.


Assuntos
Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Salmonella , Nanopartículas
2.
Talanta ; 153: 38-44, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-27130087

RESUMO

This paper addresses a sensitive method for the detection of mycobacteria in hemodialysis water samples based on a magneto-actuated immunoassay with optical readout. In this approach, micro (2.8µm) sized magnetic particles were modified with an antibody against the lipoarabinomannan (LAM) located in the mycobacterial cell wall. The system relies on the immunocapturing of the mycobacteria with the tailored antiLAM magnetic particles to pre-concentrate the bacteria from the hemodialysis samples throughout an immunological reaction. The performance of the immunomagnetic separation on the magnetic carrier was evaluated using confocal microscopy to study the binding pattern, as well as a magneto-actuated immunoassay with optical readout for the rapid detection of the bacteria in spiked hemodialysis samples. In this approach, the antiLAM polyclonal antibody was labeled with fluorescein isothiocyanate. The optical readout was achieved by the incubation with a secondary anti-fluorescein antibody labeled with peroxidase as optical reporter. The magneto-actuated immunoassay was able to detect mycobacteria contamination in hemodialysis water at a limit of detection of 13CFUmL(-1) in a total assay time of 3h without any previous culturing pre-enrichment step.


Assuntos
Mycobacterium fortuitum , Imunoensaio , Separação Imunomagnética , Magnetismo , Diálise Renal , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA