Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38700946

RESUMO

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Assuntos
Ceratectomia Fotorrefrativa , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Resultado do Tratamento , Ceratectomia Fotorrefrativa/métodos , Implante de Lente Intraocular/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular/fisiologia , Estudos Retrospectivos , Miopia Degenerativa/cirurgia , Miopia Degenerativa/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Lentes Intraoculares Fácicas , Adulto , Masculino , Feminino
2.
Curr Opin Ophthalmol ; 34(4): 280-289, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37254862

RESUMO

PURPOSE OF REVIEW: The purpose of this article is to provide a review of the literature on refractive lens exchange and present a retrospective analysis of 55 patients who underwent refractive lens exchange at a single practice. RECENT FINDINGS: Our study substantiates refractive lens exchange as an important option for presbyopic patients, hyperopic patients or patients with extremely high refractive error who desire spectacle independence. SUMMARY: Our study reveals that the refractive lens exchange population is younger than the average cataract population and their primary motivations are to resolve hyperopic or myopic refractive errors, gain spectacle independence, and address near vision loss. A variety of presbyopia-addressing intraocular lens options are available and we present our experience with multifocal, extended depth-of-focus, light-adjustable, and monofocal lenses.


Assuntos
Cristalino , Lentes Intraoculares , Presbiopia , Humanos , Acuidade Visual , Estudos Retrospectivos , Implante de Lente Intraocular , Presbiopia/cirurgia
3.
Curr Opin Ophthalmol ; 33(4): 269-274, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35779051

RESUMO

PURPOSE OF REVIEW: Despite affecting approximately 1.8 billion individuals worldwide, until recently, a pharmacologic treatment for presbyopia was not available. This special commentary reviews the treatment of presbyopia with a focus on the recently approved medication Vuity (pilocarpine 1.25%, Allergan, an AbbVie Company). RECENT FINDINGS: Vuity is a re-engineered formulation of pilocarpine 1.25% specifically designed for the treatment of presbyopia. Recently published results from the GEMINI 1 Phase 3 clinical trial reported improvement in distance corrected near vision without significant compromise in distance vision. No unexpected safety findings were reported with mild headache being the most common adverse event. Notably, there were no reported cases of retinal detachment or angle closure during the 30-day phase 3 clinical trials. SUMMARY: Vuity is the first treatment designed and FDA approved to treat the growing presbyopia market. Phase 3 clinical trials demonstrated its ability to improve near vision without significant compromise in distance vision. We recognize this paradigm shift in the treatment of presbyopia and anxiously await additional treatment options for this ubiquitous condition.


Assuntos
Miopia , Presbiopia , Humanos , Pilocarpina/uso terapêutico , Presbiopia/tratamento farmacológico , Visão Ocular
4.
Curr Opin Ophthalmol ; 31(4): 253-260, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32487811

RESUMO

PURPOSE OF REVIEW: The subject of artificial intelligence has recently been responsible for the advancement of many industries including aspects of medicine and many of its subspecialties. Within ophthalmology, artificial intelligence technology has found ways of improving the diagnostic and therapeutic processes in cornea, glaucoma, retina, and cataract surgery. As demands on the modern ophthalmologist grow, artificial intelligence can be utilized to help address increased demands of modern medicine and ophthalmology by adding to the physician's clinical and surgical acumen. The purpose of this review is to highlight the integration of artificial intelligence into ophthalmology in recent years in the areas of cornea, refractive, and cataract surgery. RECENT FINDINGS: Within the realms of cornea, refractive, and cataract surgery, artificial intelligence has played a major role in identifying ways of improving diagnostic detection. In keratoconus, artificial intelligence algorithms may help with the early detection of keratoconus and other ectatic disorders. In cataract surgery, artificial intelligence may help improve the performance of intraocular lens (IOL) calculation formulas. Further, with its potential integration into automated refraction devices, artificial intelligence can help provide an improved framework for IOL formula optimization that is more accurate and customized to a specific cataract surgeon. SUMMARY: The future of artificial intelligence in ophthalmology is a promising prospect. With continued advancement of mathematical and computational algorithms, corneal disease processes can be diagnosed sooner and IOL calculations can be made more accurate.


Assuntos
Inteligência Artificial , Extração de Catarata , Doenças da Córnea/diagnóstico , Procedimentos Cirúrgicos Refrativos , Biometria/métodos , Humanos , Lentes Intraoculares , Óptica e Fotônica
5.
Int Ophthalmol ; 40(7): 1773-1779, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32297049

RESUMO

BACKGROUND: To evaluate the efficacy of corneal tattooing for various clinical applications. METHODS: The medical charts of 62 eyes of 62 patients who underwent corneal tattooing between March 2016 and August 2017 were retrospectively reviewed. The causes of opacity and various methods of corneal tattooing were analyzed. RESULTS: Among our 62 patients, 38 were males and 24 were females. Average age was 48.47 ± 15.30 (range, 12-74) years old. The mean follow-up period was 40.19 ± 2.34 (range, 36-43) months. The most common causes of corneal opacity were ocular trauma (33 eyes, 53.2%), prior retinal surgery (9 eyes, 14.5%), congenital etiologies (8 eyes, 12.9%) and measles (5 eyes, 8.0%). The most common associated ocular findings were strabismus (23 eyes, 37.0%), phthisis bulbi (17 eyes, 27.4%) and band keratopathy (13 eyes, 20.9%). Cosmetic outcomes improved without serious complications in all cases. CONCLUSIONS: Corneal tattooing is a viable option with an expanding set of indications, such as discolored previous corneal tattoos, white pupil due to inoperable cataract with clear cornea and dense corneal opacities in blind eyes. Elective corneal tattooing seems to be a viable and convenient method to improve cosmesis with minimal complications and high patient satisfaction.


Assuntos
Córnea , Opacidade da Córnea , Tatuagem , Adolescente , Adulto , Idoso , Criança , Opacidade da Córnea/diagnóstico , Opacidade da Córnea/etiologia , Opacidade da Córnea/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Oftalmológicos , Estudos Retrospectivos , Adulto Jovem
6.
Curr Opin Ophthalmol ; 30(4): 220-228, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31170100

RESUMO

PURPOSE OF REVIEW: To review the efficacy of intrastromal corneal ring segments (ICRS) for keratoconus and with other interventions such as contacts lens, keratoplasty, and corneal collagen cross-linking. RECENT FINDINGS: Changes in ICRS thickness and size, combination of procedures, and the adaptation of a more sophisticated classification system have broadened our application of ICRS. Recent studies have shown the long-term efficacy of ICRS in visual acuity, keratometry, and astigmatism. SUMMARY: Studies have demonstrated the short-term and long-term efficacy of ICRS implantation in patients with keratoconus.


Assuntos
Substância Própria/cirurgia , Ceratocone/cirurgia , Próteses e Implantes , Implantação de Prótese/métodos , Colágeno/metabolismo , Lentes de Contato , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratocone/metabolismo , Fotoquimioterapia/métodos , Resultado do Tratamento , Acuidade Visual/fisiologia
9.
BMC Ophthalmol ; 18(1): 276, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30359246

RESUMO

BACKGROUND: Toxic anterior segment syndrome (TASS) can be a rare complication of anterior segment surgery. Here we reviewed the most recent advances in the understanding of TASS. METHODS: English articles related to TASS were retrieved from "PubMed" using the following keywords; "toxic anterior segment syndrome" or "TASS". The authors of this paper reviewed all the retrieved literature and critical findings were summarized. RESULTS: The onset of TASS can vary from hours to months. The clinical manifestations are also variable. The causes of TASS are broad and continue to expand and could not be elucidated in over half of the reported cases. Prompt and thorough investigation to explore the causes of TASS is critical. Surgeons should be fully aware and updated regarding possible etiologies and make ceaseless efforts to prevent TASS. This effort begins with establishing TASS prevention protocols and regularly training surgical staff. Proper cleaning of surgical instruments is critical and should follow the guidelines set by The American Society of Cataract and Refractive Surgery TASS Task Force. When TASS occurs, sharing information with other ophthalmologists and reporting new causes is crucial for the prevention of outbreaks. CONCLUSIONS: Anterior segment surgeons should be reminded that TASS is mostly preventable by the establishment of TASS prevention protocols, regular surgical staff training and thorough adherence to recommendations for cleaning and sterilizing intraocular surgical instruments.


Assuntos
Segmento Anterior do Olho , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias , Oftalmopatias/diagnóstico , Oftalmopatias/epidemiologia , Oftalmopatias/etiologia , Saúde Global , Humanos , Incidência , Síndrome
10.
BMC Ophthalmol ; 17(1): 187, 2017 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-29017515

RESUMO

BACKGROUND: To report the recurrence rate for an anchored conjunctival rotation flap technique in primary pterygium surgery. METHODS: Primary pterygium surgeries performed using anchored conjunctival rotation flap techniques (110 eyes in 110 patients) with a minimum follow-up of 12 months were reviewed. In this technique, a conjunctival flap is rotated to cover the bare sclera and suture-fixated with either 8-0 polyglactin (41 eyes) or 10-0 nylon (69 eyes). The recurrence rate was determined, and the two suture materials utilized were compared. RESULTS: The recurrence rate was 2.71% (3 cases in 110 eyes) when an anchored conjunctival rotation flap technique was used and patients were monitored for 26.40 ± 17.09 months. Interestingly, the recurrences were only observed in polyglactin-sutured eyes. No recurrence was detected in nylon-sutured eyes. No other complications were observed in either group. CONCLUSIONS: The anchored conjunctival rotation flap technique for pterygium surgery has a relatively low recurrence rate. Nylon suture-fixation of the flap was found to be superior to polyglactin suture-fixation in preventing recurrence.


Assuntos
Túnica Conjuntiva/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Pterígio/cirurgia , Retalhos Cirúrgicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Nylons , Pterígio/prevenção & controle , Recidiva , Estudos Retrospectivos , Esclera/cirurgia , Técnicas de Sutura , Suturas
11.
BMC Ophthalmol ; 17(1): 62, 2017 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-28464806

RESUMO

BACKGROUND: To evaluate how differences in ocular biometry affects the Hoffer Q, Holladay 1, SRK/T, and Haigis intraocular lens power calculation formulae predictions. METHODS: This study was performed on 91 eyes of 91 patients who underwent uneventful cataract surgery. Ocular biometry values were measured using the IOL Master 500, and intraocular lens (IOL) power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. We calculated the expected difference (ED) of each 3rd generation formula from the Haigis formula by subtracting the predicted refraction of the Haigis formula from the predicted refraction of each 3rd generation formula. Post-operative anterior chamber depth (ACD) was measured at 1 month after surgery using the IOL master. We calculated errors of each formula by subtracting predicted from manifest refraction at post-operative 1 month. Correlation analysis was performed between ocular biometry values, formula expectation values, formula errors and absolute formula errors. RESULTS: Multiple regression analysis revealed that preoperative ACD was the only significant factor for ED prediction in all of the 3rd generation formulas. For mean errors, axial length and post-operative 1-month change of ACD (delta ACD) correlated significantly with the errors in all 3rd generation formulas, but not with errors of the Haigis formula. Median absolute error (MedAE) of the formulas were 0.40 D for the Hoffer Q formula, 0.37 D for the Holladay formula, 0.34 D for the SRK/T formula, and 0.41 D for the Haigis formula. The MAE of the formulas were 0.50 ± 0.47 D for the Hoffer Q formula, 0.50 ± 0.50 D for the Holladay formula, 0.47 ± 0.51 D for the SRK/T formula, and 0.50 ± 0.47 D for the Haigis formula. CONCLUSION: Regarding ED between the third generation and Haigis formulas, preoperative ACD demonstrated the greatest influence. Calculating mean absolute errors of the formulas, all IOL formulas showed excellent and comparable accuracy. Post-operative change (delta) of ACD correlated significantly with errors of third generation formulas according to simulated ACD.


Assuntos
Câmara Anterior/patologia , Biometria/métodos , Lentes Intraoculares , Óptica e Fotônica/métodos , Pseudofacia/diagnóstico , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Pseudofacia/fisiopatologia , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Testes Visuais
12.
BMC Ophthalmol ; 17(1): 111, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28666434

RESUMO

BACKGROUND: The opacification of the intraocular lens (IOL) can cause significant visual deterioration. It is known that opacity of hydrophobic acrylic IOLs is rare. We report 2 cases of reversible optic opacification of hydrophobic acrylic intraocular lenses (Tecnis ZCB00, Abbott), observed within 2 months after uneventful cataract surgery. CASE PRESENTATION: Case 1: Uneventful cataract surgery was performed on the left eye of an 86-year-old diabetic man with chronic open-angle glaucoma. A hydrophobic acrylic intraocular lens (IOL; Tecnis ZCB00, Abbott, Lake Bluff, IL) was implanted in the bag. Eye drops containing 0.5% levofloxacin and 1.0% prednisolone were used after surgery along with topical anti-glaucoma medications. At 7 weeks postoperative, cloudy, concentric IOL opacification developed, accompanied by decreased visual acuity and increased intraocular pressure. However, the opacification completely disappeared after 9 weeks. Case 2: Uneventful cataract surgery was performed on the left eye of a 72-year-old woman. A hydrophobic acrylic IOL (Tecnis ZCB00) was implanted in the bag. At 2 weeks postoperative, cloudy, concentric IOL opacification developed, accompanied by ocular discomfort. After 4 weeks, opacification and discomfort completely disappeared. CONCLUSIONS: We observed two cases of completely reversible opacification of hydrophobic acrylic IOLs. The exact nature of the transient opacity remains unclear, but an inflammatory origin cannot be completely ruled out.


Assuntos
Resinas Acrílicas , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Facoemulsificação , Falha de Prótese
13.
Ophthalmology ; 122(12): 2432-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26386848

RESUMO

PURPOSE: To report evolving indications and preferred techniques of corneal transplantation in the United States. DESIGN: Retrospective review. METHODS: Annual reports from the Eye Bank Association of America on corneal graft distribution in the United States from 2005 through 2014 were reviewed. MAIN OUTCOME MEASURES: Number and percentage of corneal grafts distributed for various types of keratoplasty and their surgical indications in the United States. RESULTS: The total number of corneal transplants increased from 44 277 in 2005 to 46 513 in 2014. In the past decade, penetrating keratoplasty dramatically decreased (from 95% to 42%) and largely has been replaced by various lamellar keratoplasty (LK) techniques (from 5% to 58%). Descemet stripping (automated) endothelial keratoplasty was the most common (50%) type of corneal transplantation performed in the United Stated in 2014. The volume of Descemet membrane endothelial keratoplasty (DMEK) has been doubling every year since 2011 and accounted for 11% of total endothelial keratoplasties in 2014. There was a significant shift in indication for corneal transplantation, with Fuchs' endothelial dystrophy (22%) being the most common, followed by corneal edema occurring after cataract surgery (12%) in 2014. Eye banks supplied precut corneal grafts for 68% of LK techniques in 2014. CONCLUSIONS: In the United States, there has been a major shift in preferred keratoplasty techniques over the past decade, with a wide adoption of new LK techniques.


Assuntos
Doenças da Córnea/cirurgia , Transplante de Córnea/tendências , Transplante de Córnea/estatística & dados numéricos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/estatística & dados numéricos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/tendências , Bancos de Olhos/estatística & dados numéricos , Humanos , Ceratoplastia Penetrante/estatística & dados numéricos , Ceratoplastia Penetrante/tendências , Estudos Retrospectivos , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Estados Unidos/epidemiologia
14.
Curr Opin Ophthalmol ; 31(4): 223-224, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32487812
15.
Curr Opin Ophthalmol ; 26(4): 260-4, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26058022

RESUMO

PURPOSE OF REVIEW: Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. RECENT FINDINGS: SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SUMMARY: SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.


Assuntos
Substância Própria/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Terapia a Laser/métodos , Microcirurgia/métodos , Miopia/cirurgia , Fenômenos Biomecânicos , Córnea/fisiologia , Elasticidade/fisiologia , Humanos , Miopia/fisiopatologia
16.
Curr Opin Ophthalmol ; 25(4): 286-90, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24837578

RESUMO

PURPOSE OF REVIEW: Astigmatism is a common refractive error that affects a significant portion of the population. This is a review of the most salient topics on assessing astigmatism as well as a discussion of the latest developments in surgical options and newest technologies to improve outcomes. RECENT FINDINGS: Laser corneal ablation continues to be highly effective for correcting low-to-moderate levels of astigmatism and may be the best option for the younger patient population. For eyes with astigmatism and cataracts, both peripheral corneal-relaxing incisions and cataract extraction with toric intraocular lenses have proven to be effective. Improved assessment of astigmatism, methods to select more accurate lens power, and new technologies to confirm proper axis alignment have all contributed to minimizing postoperative residual astigmatism. SUMMARY: Cataract surgery has evolved into a refractive procedure, in which not only the sphere but also cylinder errors can now be confidently corrected. Careful assessment and surgical planning of astigmatism should not be an option, but essential components of cataract surgery.


Assuntos
Astigmatismo/cirurgia , Extração de Catarata , Cirurgia da Córnea a Laser , Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Ceratoplastia Penetrante
18.
Curr Opin Ophthalmol ; 29(4): 275-276, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29782337
19.
Acta Paediatr ; 102(2): e90-3, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23194445

RESUMO

UNLABELLED: Lung lavage using two aliquots of 15 mL/kg of dilute surfactant was performed in 30 ventilated infants with severe meconium aspiration syndrome (MAS). Mean recovery of instilled lavage fluid was 46%, with greater fluid return associated with lower mean airway pressure at 24 h and a shorter duration of respiratory support. CONCLUSION: Recovery of instilled lavage fluid is paramount in effective lung lavage in MAS and must be afforded priority in the lavage technique.


Assuntos
Lavagem Broncoalveolar/métodos , Síndrome de Aspiração de Mecônio/terapia , Líquido da Lavagem Broncoalveolar , Terapia Combinada , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Modelos Lineares , Fatores de Tempo , Resultado do Tratamento
20.
Curr Opin Ophthalmol ; 28(4): 297-298, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28505036
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA