1.
Pol Merkur Lekarski ; 46(273): 109-114, 2019 Mar 28.
Artigo em Polonês | MEDLINE | ID: mdl-30912518

RESUMO

The size of the right atrium (RA) reduces after transcatheter closure of the atrial septal defect (ASD). Inverse structural and electrical remodeling is observed. AIM: The aim of study was to analyze the parameters predisposing to the lack of normalization of enlarged RA after transcatheter closure of ASD during 6-month follow-up. MATERIALS AND METHODS: A prospective study included 56 consecutive adult patients (12 men) aged from 23 to 76 years (49.8±13.3 years) with ASD, in whom transcatheter ASD closure was performed. Each patient was assessed before and 6 months after the treatment using standard 12-lead resting electrocardiogram (ECG), 24-hour Holter monitoring and echocardiography. RESULTS: Before the procedure in 37 patients with ASD enlarged RA was observed, while after transcatheter ASD closure in 24 patients normalization of enlarged RA was noted. Patients in whom 6 months after the procedure there was no normalization of the enlarged RA were older, characterized by higher right ventricular systolic pressure (RVSP), pulmonary to systemic blood flow ratio (Qp/Qs), larger size of the occluder, interatrial septal defect, longer fluoroscopy time and lower left ventricular ejection fraction. P-wave dispersion (Pdysp) was found to be a destimulant i.e. increased Pdysp (>67 ms, P<0.000) decreased the chance of RA normalization after procedure. On the other hand, minimum P-wave duration (Pmin) was a stimulant, therefore, increased Pmin (>72ms, P<0.000) increased the chance of RA normalization. A significant association was found between the reduction of supraventricular extrasystolic beats and RA area normalization (P<0.001), and there was no association between the incidence of atrial fibrillation episodes and RA area normalization. CONCLUSIONS: Evaluation of the duration of the P-wave and its dispersion may help to assess the prognosis of the right atrium size normalization in the mid-term follow-up after transcatheter closure of ASD. There is a significant relationship between normalization of the right atrium size and reduction of supraventricular extrasystolic beats.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial , Adulto , Idoso , Ecocardiografia , Seguimentos , Átrios do Coração , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
2.
Pol Merkur Lekarski ; 42(248): 65-70, 2017 Feb 20.
Artigo em Polonês | MEDLINE | ID: mdl-28258679

RESUMO

The task of the ICD is to detect ventricular arrhythmias and treatment of its adequate intervention. The task of the CRTD in addition to the above tasks is the treatment of heart failure. AIM: The aim of the study was to assess the predictive parameters of adequate interventions in patients with an ICD and CRTD. MATERIALS AND METHODS: The study consisted of 273 patients (230 M, mean age 65±11 years) with ICD and/or CRTD. The inclusion criteria were: left ventricle ejection fraction (LVEF) ≤ 35%, NYHA class ≥ II, implantation in primary SCD prevention and in case of CRTD additionally LBBB with wide QRS ≥ 120ms. The following data were assessed: age, gender, presence of dilated cardiomyopathy, diabetes, chronic kidney failure, atrial fibrillation (AF), LVEF, NYHA class, device interventions, number of arrhythmias, changes in pharmacotherapy, device parameters and mortality. RESULTS: During observation, which lasted the mean of 770±490 days, 102 patients had adequate device interventions. In the ICD group, adequate interventions appear mainly in the initial observation period (HR 2,01), in patients with left ventricular hypertrophy (HR 2,98) and ventricular arrhythmias (HR 6,78) and not treated with amiodarone (HR 4,31). In the CRTD group, adequate interventions appear mainly in younger patients (HR 1,06), in diabetes (HR 1,68), in NYHA class II, in paroxysmal atrial fibrillation (HR 1,09) and ventricular arrhythmias (HR 2,54) and not treated with amiodarone (HR 1,09). CONCLUSIONS: In the ICD group, left ventricular hypertrophy, ventricular arrhythmias is not treated with amiodarone in a significant influence on the risk of adequate intervention. In the Group of CRTD younger age, diabetes, NYHA class II, paroxysmal atrial fibrillation, ventricular arrhythmias is not treated with amiodarone in a significant influence on the risk of adequate intervention. In the ICD group, adequate interventions particularly often in the first year of follow-up. Patients with CRTD require special medical care.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/complicações , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Idoso , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/complicações , Cardiomiopatia Dilatada/terapia , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
3.
Pol Merkur Lekarski ; 42(247): 13-20, 2017 Jan 23.
Artigo em Polonês | MEDLINE | ID: mdl-28134226

RESUMO

Telemetric follow-up (RM) after cardiac devices implantation is not inferior to classic follow-up and enables earlier clinical complications detection. AIM: The aim of the study was to evaluation of the ventricular arrhythmias and interventions of ICD/CRTD in ambulatory and telemetric follow-up in patients with dilated cardiomyopathy. MATERIALS AND METHODS: Group A (CRT-D+ICD) - retrospective, patients followed-up in outpatient clinic - was consisted with 273 patients (mean age 65±11 years, 230M). In group A 128 patients after CRT-D implantation and 145 patients with ICD were selected. Group B (RM group) - prospective, RM Medtronic Carelink followup - was consisted with 177 patients (mean age 61±13 years, 141M). 35 patients had CRT-D and 142 had ICD implanted. Follow-up of patients from group A was performed in outpatient clinic. Follow-up of patients from group B was monitored daily follow-up using RM system (Medtronic Carelink). Frequency/type of ventricular arrhythmias, device interventions, patient's clinical status, medications, were assessed in both groups. To assess presence of ventricular arrhythmias, device interventions, ICD and CRT-D programming changes, pharmacotherapy changes, patients were randomly chosen from group A, according to age, gender, LVEF value, NYHA class, comorbidities, time of follow-up as a control group to group B (RM group). RESULTS: In multivariate analysis, it was found that a low ejection fraction <25% (HR 0,929; p<0,001), and diabetes mellitus (HR 7,038; p<0,009) predispose to ventricular arrhythmias. In the RM group, compared to control group, there were significantly less programming changes (5,9 vs 47,1%, p<0,001), time to first events (ventricular arrhythmias - 258 vs 487 d, p<0,001; interventions - 295 vs 775 d, p<0,01) was shorter, while time to first necessary programming (364 vs 304 d, p<0,001) or pharmacotherapy (330 vs 244 days, p<0,001) change was longer. General mortality did not differ significantly between the groups (p=0,130). CONCLUSIONS: Low ejection fraction <25%, and diabetes mellitus predispose to ventricular arrhythmias. Telemetric follow-up of cardiac implantable devices enables quick information transmission in cases of clinical complications (arrhythmias, interventions) and reduces number of ambulatory visits to only necessary ones. Telemetric followup of cardiac implantable devices is a safe. Key words: ventricular arrhythmias, interventions.


Assuntos
Arritmias Cardíacas/terapia , Cardiomiopatia Dilatada/complicações , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ventrículos do Coração , Prevenção Primária , Idoso , Arritmias Cardíacas/complicações , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polônia , Telemetria , Resultado do Tratamento
4.
Przegl Lek ; 74(4): 157-62, 2017.
Artigo em Polonês | MEDLINE | ID: mdl-29696953

RESUMO

The assessment of factors influencing occurrence of adequate interventions of cardiac resynchronization therapy with cardioverter-defibrillator implanted in primary prevention of sudden cardiac death in dilative cardiomyopathy and percentage of biventricular pacing. Introduction: The function of cardiac resynchronization therapy with cardioverter-defibrillator (CRT-D) is to treat heart failure (HF) and to treat ventricular arrhythmia, if it occurs, with adequate intervention. Aim: The aim of the study was to find predictors of adequate interventions and in how many patients biventricular pacing percentage decreases during the follow-up. Material and methods: The study comprised of 228 patients (178 M, mean age 66±10, 31-89 years) with implanted CRTD. The following data were analyzed: age, sex, presence of dilative cardiomyopathy, diabetes mellitus, lowered creatinine clearance, atrial fibrillation (AF), LVEF, NYHA class, adequate interventions, number of arrhythmias, pharmacotherapy modifications, device parameters and mortality. Results: Mean ejection fraction of the left ventricle was 20.9±6.4, (10.0- 35%). During the mean follow up of 770±490 days in 84 (37%) patients adequate interventions of the device occurred. The adequate interventions concerned mainly patients with diabetes mellitus (HR 2.95), in NYHA class II, with paroxysmal atrial fibrillation (HR 2.15). In 39 patients (17%) the mean percentage of biventricular pacing was below 90%, and in 18 (8%) below 85%. Conclusions: Diabetes mellitus, NYHA class II, paroxysmal atrial fibrillation have significantly increased the risk of adequate intervention. The most common causes of loss of biventricular pacing were: inappropriate AV delay, supraventricular arrhythmias and premature ventricular complexes. A significant correlation between low biventricular pacing percentage and the occurrence of supraventricular arrhythmias and adequate interventions was observed.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial , Cardiomiopatia Dilatada/complicações , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Diabetes Mellitus , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Fatores de Risco , Resultado do Tratamento
5.
Przegl Lek ; 73(11): 830-6, 2016.
Artigo em Polonês | MEDLINE | ID: mdl-29693364

RESUMO

Introduction: Remote monitoring of ICD/CRTD is safe, during which evaluates the type of arrhythmia, intervention. Aim: The aim of the study was the assessment of ventricular arrhythmia and ICD/CRTD intervention. Material and methods: The study included 177 patients (mean age 61,1±13; 23-88 y; Men 141) with an ICD/CRTD implanted. Patients were controlled telemonitoring system, Medtronic Carelink. The following variables were analyzed: age, gender, comorbidities, LVEF value, NYHA class, type of ventricular arrhythmias, device interventions, reprogramming and pharmacotherapy changes. Results: In multivariate analysis, it was found that, diabetes mellitus (HR 3,49), a low ejection fraction <25% (HR 2,51) predispose to ventricular arrhythmias; and a low ejection fraction <25% (HR 1,88), ischemic DCM (HR 1,92), II NYHA class, the lack of Amiodarone (HR 5,01) predispose to device intervention. Conclusions: 1. A low ejection fraction, ischemic dilative cardiomyopathy, II NYHA class, the lack treatment of Amiodarone predispose to ventricular arrhythmias. 2. A low ejection fraction, diabetes mellitus predispose to device intervention. 3. A significant correlation between interventions and ventricular arrhythmias, renal failure, diabetes mellitus, abnormal lipidogram were observed. 4. Telemetric follow-up of cardiac implantable devices is a safe and enables quick information transmission in cases of clinical complications (arrhythmias, interventions).


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/complicações , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Complicações do Diabetes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Fatores de Risco , Volume Sistólico , Telemetria , Adulto Jovem
6.
Adv Clin Exp Med ; 28(8): 1079-1085, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31237120

RESUMO

BACKGROUND: Atrial septal defect (ASD) and patent foramen ovale (PFO) are specific types of atrial septal communications (ASC). OBJECTIVES: We aimed to assess quality of life (QoL) in patients before and after percutaneous closure of ASC and determine the factors influencing QoL in this group of patients. MATERIAL AND METHODS: We performed a clinical assessment and conducted an SF-36 questionnaire, electrocardiography and echocardiography studies in patients before and 6 months after percutaneous ASC closure. RESULTS: Patients with ASD (n = 56) had a lower SF-36 total score than those with PFO (n = 73), before and after percutaneous ASC occlusion (both p < 0.001). After the procedure, the improvement of SF-36 total score in patients with ASD or atrial fibrillation was greater (p < 0.001 and p = 0.005, respectively). We observed correlations between improvement of QoL and baseline supraventricular extrasystolic beats (rs = 0.28; p = 0.002), but not ventricular extrasystolic beats (rs = 0.03; p = 0.76). Quality of life improvement was predicted in patients with ASD by higher baseline tricuspid annular plane systolic excursion (TAPSE) and right ventricular longitudinal dimension R2 = 0.38; p < 0.001. However, in patients with PFO, this was predicted by TAPSE, lack of arterial hypertension and usage of angiotensin-converting enzyme inhibitors, R2 = 0.30; p < 0.001. CONCLUSIONS: Patients with ASD have lower QoL than those with PFO before and after percutaneous ASC occlusion. Six months after the procedure, the improvement of QoL in patients with ASD was higher than in those with PFO. The change in QoL self-assessed by patients after the procedure was associated with episodes of arrhythmia and was predicted with echocardiographic and clinical parameters.


Assuntos
Cateterismo Cardíaco , Forame Oval Patente , Comunicação Interatrial , Qualidade de Vida , Ecocardiografia , Seguimentos , Forame Oval Patente/terapia , Comunicação Interatrial/terapia , Humanos , Resultado do Tratamento
7.
Kardiol Pol ; 76(10): 1465-1473, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30067278

RESUMO

BACKGROUND: Atrial septal communications (ASCs) include atrial septal defects (ASDs) and patent foramen ovale (PFO). AIM: The purpose of this study was to assess P-wave dispersion (PWD) and the prevalence of arrhythmia in patients before and after ASC closure. METHODS: We analysed the clinical history and performed 12-lead electrocardiograms, echocardiograms, and 24-h Holter electrocardiograms in patients with ASC, before and six months after ASC closure. RESULTS: We included patients with ASD (n = 56) and PFO (n = 73). PWD before percutaneous ASC closure was predicted by right ventricular outflow tract (RVOT) proximal diameter, left atrial area, ASD, smoking, and paroxysmal dyspnoea, R2 = 0.67; p < 0.001. RVOT proximal diameter was an independent predictor of PWD, both in patients with ASD and PFO. Six months after successful closure of ASC, a reduction in PWD was observed in the whole group of patients as well as in patients with ASD and PFO considered separately. A decrease in PWD was associated with reduction of maximum P-wave duration. At the same time, in the whole group, we noticed a reduction in the number of supraventricular and ventricular extrasystolic beats and fewer atrial fibrillation (AF) episodes, p < 0.04 for all variables. Postprocedural AF episodes in patients with ASD were predicted by PWD of 80 ms. CONCLUSIONS: Percutaneous closure of ASC is associated with a reduction of PWD and fewer arrhythmia episodes six months after the procedure. PWD predicts AF episodes after ASD closure.


Assuntos
Fibrilação Atrial/etiologia , Comunicação Interatrial/cirurgia , Adulto , Fibrilação Atrial/diagnóstico , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Comunicação Interatrial/complicações , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento