Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Environ Health ; 20(1): 58, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980260

RESUMO

BACKGROUND: At a regional or continental scale, the characterization of environmental health inequities (EHI) expresses the idea that populations are not equal in the face of pollution. It implies an analysis be conducted in order to identify and manage the areas at risk of overexposure where an increasing risk to human health is suspected. The development of methods is a prerequisite for implementing public health activities aimed at protecting populations. METHODS: This paper presents the methodological framework developed by INERIS (French National Institute for Industrial Environment and Risks) to identify a common framework for a structured and operationalized assessment of human exposure. An integrated exposure assessment approach has been developed to integrate the multiplicity of exposure pathways from various sources, through a series of models enabling the final exposure of a population to be defined. RESULTS: Measured data from environmental networks reflecting the actual contamination of the environment are used to gauge the population's exposure. Sophisticated methods of spatial analysis are applied to include additional information and take benefit of spatial and inter-variable correlation to improve data representativeness and characterize the associated uncertainty. Integrated approaches bring together all the information available for assessing the source-to-human-dose continuum using a Geographic Information System, multimedia exposure and toxicokinetic model. DISCUSSION: One of the objectives of the integrated approach was to demonstrate the feasibility of building complex realistic exposure scenarios satisfying the needs of stakeholders and the accuracy of the modelling predictions at a fine spatial-temporal resolution. A case study is presented to provide a specific application of the proposed framework and how the results could be used to identify an overexposed population. CONCLUSION: This framework could be used for many purposes, such as mapping EHI, identifying vulnerable populations and providing determinants of exposure to manage and plan remedial actions and to assess the spatial relationships between health and the environment to identify factors that influence the variability of disease patterns.


Assuntos
Exposição Ambiental , Medição de Risco/métodos , Benzoatos/urina , Saúde Ambiental , Contaminação de Alimentos , Sistemas de Informação Geográfica , Humanos , Inseticidas/farmacocinética , Inseticidas/toxicidade , Modelos Teóricos , Nitrilas/farmacocinética , Nitrilas/toxicidade , Piretrinas/farmacocinética , Piretrinas/toxicidade
2.
Anal Bioanal Chem ; 411(10): 1957-1977, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30830245

RESUMO

Untargeted analysis of a composite house dust sample has been performed as part of a collaborative effort to evaluate the progress in the field of suspect and nontarget screening and build an extensive database of organic indoor environment contaminants. Twenty-one participants reported results that were curated by the organizers of the collaborative trial. In total, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3), making the collaborative trial a success. However, a relatively small share (37%) of all compounds were reported by more than one participant, which shows that there is plenty of room for improvement in the field of suspect and nontarget screening. An even a smaller share (5%) of the total number of compounds were detected using both liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS). Thus, the two MS techniques are highly complementary. Most of the compounds were detected using LC with electrospray ionization (ESI) MS and comprehensive 2D GC (GC×GC) with atmospheric pressure chemical ionization (APCI) and electron ionization (EI), respectively. Collectively, the three techniques accounted for more than 75% of the reported compounds. Glycols, pharmaceuticals, pesticides, and various biogenic compounds dominated among the compounds reported by LC-MS participants, while hydrocarbons, hydrocarbon derivatives, and chlorinated paraffins and chlorinated biphenyls were primarily reported by GC-MS participants. Plastics additives, flavor and fragrances, and personal care products were reported by both LC-MS and GC-MS participants. It was concluded that the use of multiple analytical techniques was required for a comprehensive characterization of house dust contaminants. Further, several recommendations are given for improved suspect and nontarget screening of house dust and other indoor environment samples, including the use of open-source data processing tools. One of the tools allowed provisional identification of almost 500 compounds that had not been reported by participants.

3.
Toxicol Appl Pharmacol ; 294: 65-77, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26802525

RESUMO

Permethrin, a pyrethroid insecticide, is suspected to induce neuronal and hormonal disturbances in humans. The widespread exposure of the populations has been confirmed by the detection of the urinary metabolites of permethrin in biomonitoring studies. Permethrin is a chiral molecule presenting two forms, the cis and the trans isomers. Because in vitro studies indicated a metabolic interaction between the trans and cis isomers of permethrin, we adapted and calibrated a PBPK model for trans- and cis-permethrin separately in rats. The model also describes the toxicokinetics of three urinary metabolites, cis- and trans-3-(2,2 dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid (cis- and trans-DCCA), 3-phenoxybenzoic acid (3-PBA) and 4'OH-phenoxybenzoic acid (4'-OH-PBA). In vivo experiments performed in Sprague-Dawley rats were used to calibrate the PBPK model in a Bayesian framework. The model captured well the toxicokinetics of permethrin isomers and their metabolites including the rapid absorption, the accumulation in fat, the extensive metabolism of the parent compounds, and the rapid elimination of metabolites in urine. Average hepatic clearances in rats were estimated to be 2.4 and 5.7 L/h/kg for cis- and trans-permethrin, respectively. High concentrations of the metabolite 4'-OH-PBA were measured in urine compared to cis- and trans-DCCA and 3-PBA. The confidence in the extended PBPK model was then confirmed by good predictions of published experimental data obtained using the isomers mixture. The extended PBPK model could be extrapolated to humans to predict the internal dose of exposure to permethrin from biomonitoring data in urine.


Assuntos
Inseticidas/metabolismo , Inseticidas/farmacocinética , Permetrina/metabolismo , Permetrina/farmacocinética , Tecido Adiposo/metabolismo , Algoritmos , Animais , Área Sob a Curva , Teorema de Bayes , Inseticidas/urina , Fígado/metabolismo , Masculino , Permetrina/urina , Ratos , Ratos Sprague-Dawley , Estereoisomerismo , Distribuição Tecidual , Toxicocinética
4.
Anal Bioanal Chem ; 406(30): 7785-97, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25381610

RESUMO

Meconium is the earliest stool of newborns. It is a complex matrix that reflects the degree of fetal exposure to environmental pollutants. To investigate exposure to xenobiotics, an analytical method was developed to identify and quantify some pesticides and their metabolites and BTEX metabolites in meconium. Samples were prepared by two liquid-solid extractions and purified twice using SPE cartridges, followed by analysis with liquid chromatography coupled with tandem mass spectrometry. SPE cartridges (polymeric phase with hydrophilic and hydrophobic interactions, ion exchange, mixed mode) were tested and matrix effects were evaluated to determine purification performance. The quantification limits in meconium of this multi-residue method were in the range of 30 ng g(-1). The analytical method was applied to "real" meconium samples. Some target analytes were determined in most samples.


Assuntos
Poluentes Ambientais/análise , Espectrometria de Massas/métodos , Mecônio/química , Extração em Fase Sólida/métodos , Benzeno/análise , Derivados de Benzeno/análise , Monitoramento Ambiental/métodos , Feto/química , Humanos , Recém-Nascido , Limite de Detecção , Praguicidas/análise , Tolueno/análise , Xilenos/análise
5.
Anal Bioanal Chem ; 406(18): 4481-90, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24838489

RESUMO

Meconium is the earliest stool of newborns, and is a complex matrix that reflects the degree of exposure of the fetus to xenobiotics. To investigate fetal exposure to volatile organic compounds, an analytical method was developed to identify and quantify BTEX (benzene, toluene, ethylbenzene, and o,m,p-xylene) and two chlorinated solvents (trichloroethylene and tetrachloroethylene) in meconium. Headspace-solid-phase microextraction coupled with gas chromatography-mass spectrometry was selected because it is simple, sensitive, can be automated, and requires no extensive sample preparation. Several extraction variables were optimized (fiber type, incubation time, temperature of fiber, and use of salt). Because meconium is a complex matrix, quantification by SPME was considered carefully because of potential interference, for example competitive adsorption. Calibration in water was compared with calibration in meconium using external and internal methods (with isotope-labeled compounds). In meconium, limits of quantification were determined to be in the range 0.064-0.096 ng g(-1) for the investigated compounds. All target compounds were determined in "real-case" meconium samples.


Assuntos
Benzeno/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mecônio/química , Microextração em Fase Sólida/métodos , Tolueno/análise , Xilenos/análise , Calibragem , Exposição Ambiental/análise , Humanos , Recém-Nascido , Limite de Detecção , Solventes/análise , Temperatura , Tetracloroetileno/análise , Tricloroetileno/análise , Compostos Orgânicos Voláteis/análise
6.
Environ Res ; 132: 311-20, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24834827

RESUMO

It is important to evaluate the impact of pesticides on human health because exposure to these compounds has been linked to harmful effects in many research studies. This exposure may be particularly harmful during the early stages of development (e.g. the prenatal period). The aim of the present study was to develop an analytical strategy for quantifying a number of pesticides and their metabolites in meconium (the neonate's first faeces), in order to characterize the extent of foetal exposure. The meconium sample was dried and grinded in order to homogenize the sample, prior to solid-liquid extraction and a purification by solid-phase extraction using a weak anion mixed-mode polymeric sorbent. Analyte separation and quantification was performed by liquid chromatography coupled to electrospray-triple quadrupole mass spectrometry. Five pesticide families (carbamates, organophosphates, pyrethroids, phenylureas and phenoxy herbicides) and their metabolites could be quantified in meconium with limits of quantification ranging between 0.2 ng/g and 200 ng/g. This method was applied to a set of 171 meconium samples collected in the Picardie region of northern France. The highest prevalence was observed for metabolites of organophosphates and carbamates (57.9% and 22.8%, respectively). The parent pesticides were rarely present and were only found at very low concentrations, except for the pyrethroids cyfluthrin and cypermethrin, which were found in 7.6% of meconium samples at concentrations of between 43.8 and 480 ng/g. The most frequently detected contaminant was the organophosphate metabolite dimethyl thiophosphate detected in 49.1% of the samples and quantified with a median concentration of 344 ng/g. These data evidence significant foetal exposure to organophosphate pesticides, pyrethroids and carbamates.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Mecônio/química , Praguicidas/análise , Cromatografia Líquida , Poluentes Ambientais/metabolismo , Feminino , França , Humanos , Recém-Nascido , Espectrometria de Massas , Exposição Materna , Praguicidas/metabolismo
7.
Chemosphere ; 352: 141242, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38280648

RESUMO

Biomass burning is a significant source of particulate matter (PM) in ambient air and its accurate source apportionment is a major concern for air quality. The discrimination between residential wood heating (RWH) and garden green waste burning (GWB) particulate matter (PM) is rarely achieved. The objective of this work was to evaluate the potential of non-targeted screening (NTS) analyses using HRMS (high resolution mass spectrometry) data to reveal discriminating potential molecular markers of both sources. Two residential wood combustion appliances (wood log stove and fireplace) were tested under different output conditions and wood moisture content. GWB experiments were carried out using two burning materials (fallen leaves and hedge trimming). PM samples were characterized using NTS approaches with both LC- and GC-HRMS (liquid and gas chromatography-HRMS). The analytical procedures were optimized to detect as many species as possible. Chemical fingerprints obtained were compared combining several multivariate statistical analyses (PCA, HCA and PLS-DA). Results showed a strong impact of the fuel nature and the combustion quality on the chemical fingerprints. 31 and 4 possible markers were discovered as characteristic of GWB and RWH, respectively. Complementary work was attempted to identify potential molecular formulas of the different potential marker candidates. The combination of HRMS NTS chemical characterization with multivariate statistical analyses shows promise for uncovering organic aerosol fingerprinting and discovering potential PM source markers.


Assuntos
Poluentes Atmosféricos , Poluentes Atmosféricos/análise , Jardins , Madeira/química , Calefação , Cromatografia Gasosa-Espectrometria de Massas , Material Particulado/análise , Monitoramento Ambiental
8.
Sci Total Environ ; 874: 162493, 2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-36863581

RESUMO

While perfluoroalkyl sulfonic acids (PFSAs) and perfluoroalkyl carboxylic acids (PFCAs) are ubiquitous in aquatic environments, non-targeted methods have recently revealed the presence of numerous unidentified per- and polyfluoroalkyl substances (PFAS). Besides those methods, the total oxidizable precursor (TOP) assay has proved useful to estimate the contribution of unattributed perfluoroalkyl acids precursors (pre-PFAAs). In this study, an optimized extraction method was developed to examine the spatial distribution of 36 targeted PFAS in surface sediments collected at French nationwide scale (n = 43), including neutral, anionic and zwitterionic molecules. In addition, a TOP assay procedure was implemented to estimate the contribution of unattributed pre-PFAAs in these samples. Conversion yields of targeted pre-PFAAs were determined for the first time under realistic conditions and led to differences in oxidation profiles compared to the common spiked ultra-pure water method. PFAS were detected in 86 % of samples and ∑PFAStargeted was in the range < Limit of Detection - 23 ng g-1 dry weight (dw) (median: 1.3 ng g-1 dw), with ∑pre-PFAAstargeted representing on average 29 ± 26 % of ∑PFAS. Among pre-PFAAs, compounds of emerging interest such as the fluorotelomer sulfonamidoalkyl betaines 6:2 FTAB and 8:2 FTAB were respectively detected in 38 % and 24 % of samples, with levels similar to those of L-PFOS (<0.36-2.2, <0.50-6.8 and < 0.08-5.1 ng g-1 dw, respectively). A hierarchical cluster analysis coupled with a geographic information system-based approach revealed similarities between groups of sampling sites. For instance, elevated contribution of FTABs were associated with the proximity to airport activities where betaine-based aqueous film-forming foam (AFFFs) might have been used. In addition, unattributed pre-PFAAs were strongly correlated with ∑PFAStargeted and they accounted for 58 % of ∑PFAS (median value); they were generally found in larger quantity near industrial and urban areas where the highest ∑PFAStargeted were also observed.

9.
Talanta ; 241: 123220, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35124549

RESUMO

Despite their very wide use in various fields, knowledge concerning surfactants in environmental solid matrices is generally poor. One of the difficulties encountered in the analysis of surfactants is their very diverse physicochemical properties which require different extraction techniques. The objective of this work was therefore to develop an extraction method in sediments that allows the simultaneous analysis of anionic, cationic and non-ionic surfactants. Different extraction techniques (salting-out, ultrasound), solvents and additives were compared. The optimized method, followed by analysis by coupling liquid chromatography with tandem mass spectrometry, was then validated and applied to real samples in which the analytes were quantified by matrix matched calibration. Optimization of the extraction parameters showed different trends depending on the surfactant family. However, ultrasound assisted extraction with a 90/10 acetonitrile/water mixture at 1% acetic acid and 0.1 M EDTA showed the best results overall. The quantification limits obtained, between 6.4 µg/kg for linear alkylbenzene sulfonate (LAS) C10 and 158 µg/kg for 1-laureth sulfate, allow the analysis of traces in sediments. Eighteen of the 27 targeted surfactants were thus detected. The highest concentrations were found for LAS and quaternary ammoniums. Strong correlations between concentrations of different homologues of the same families of surfactants were observed.


Assuntos
Tensoativos , Poluentes Químicos da Água , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Água , Poluentes Químicos da Água/análise
10.
J Expo Sci Environ Epidemiol ; 32(1): 156-168, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33824416

RESUMO

BACKGROUND: The aim of this study was to use an integrated exposure assessment approach, combining spatiotemporal modeling of environmental exposure and fate of the chemical to assess the exposure of vulnerable populations. In this study, chlorpyrifos exposure of pregnant women in Picardy was evaluated at a regional scale during 1 year. This approach provided a mapping of exposure indicators of pregnant women to chlorpyrifos over fine spatial and temporal resolutions using a GIS environment. METHODS: Fate and transport models (emission, atmospheric dispersion, multimedia exposure, PBPK) were combined with environmental databases in a GIS environment. Quantities spread over agricultural fields were simulated and integrated into a modeling chain coupling models. The fate and transport of chlorpyrifos was characterized by an atmospheric dispersion statistical metamodel and the dynamiCROP model. Then, the multimedia model Modul'ERS was used to predict chlorpyrifos daily exposure doses which were integrated in a PBPK model to compute biomarker of exposure (TCPy urinary concentrations). For the concentration predictions, two scenarios (lower bound and upper bound) were built. RESULTS: At fine spatio-temporal resolutions, the cartography of biomarkers in the lower bound scenario clearly highlights agricultural areas. In these maps, some specific areas and hotspots appear as potentially more exposed specifically during application period. Overall, predictions were close to biomonitoring data and ingestion route was the main contributor to chlorpyrifos exposure. CONCLUSIONS: This study demonstrated the feasibility of an integrated approach for the evaluation of chlorpyrifos exposure which allows the comparison between modeled predictions and biomonitoring data.


Assuntos
Clorpirifos , Inseticidas , Agricultura , Biomarcadores , Exposição Ambiental/análise , Feminino , Humanos , Gravidez , Gestantes
11.
Anal Chem ; 83(3): 966-75, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21192728

RESUMO

A variable length method development (or VL-MD)strategy, exploiting the potential of an automatic column coupling system, is proposed and has been applied to a number of different pharmaceutical and environmental samples with a varying degree of complexity. The proposed strategy consistently produced separation methods that had at least an equally good critical pair resolution and an equally short run time to those of methods produced using commercially available MD assistance software. In some cases, the VL-MD strategy allowed the MD time to be drastically shortened from >30 h to an overnight run of only 12 h. The developed strategy has the potential to become fully automated provided that reliable chromatogram read-out software becomes available. The advantage of combining different stationary phase types to improve the available selectivity and the integration into the general VL-MD strategy was also demonstrated.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Cinética , Solventes/química
12.
Talanta ; 232: 122441, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074426

RESUMO

Of the large number of emerging pollutants discharged from wastewaters into surface waters, surfactants are among those with the highest concentrations. However, few monitoring in river waters of these substances have already been performed and only on a few families, mostly anionic. This work aimed to develop a multi-family analytical strategy suitable for the quantification of low concentrations of surfactant in surface waters. Twelve families of surfactants, anionic, cationic and non-ionic were selected. Their quantification by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) and their extraction by SPE were optimized by comparing different retention mechanisms. The best performances were obtained with a C18 grafted silica LC column and a hydrophilic-lipophilic balanced (HLB) polymeric SPE cartridge. The final analytical method was validated and applied for the quantification of surfactants in 36 river water samples. Method limits of quantification (LQ), intra and inter days precision and trueness were evaluated. With LQ between 15 and 485 ng/L, and trueness over 80%, this method was suitable for monitoring surfactants in surface water. Application on French river water samples revealed the presence of anionic, cationic and non-ionic surfactants with median concentrations from 24 ng/L for octylphenol ethoxylates (OPEO), up to 4.6 µg/L regarding linear alkylbenzene sulfonates (LAS).

13.
Sci Total Environ ; 798: 149367, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34375266

RESUMO

This work provides an evaluation of the emission factors (EFs) of typical garden waste burning (fallen leaves and hedge trimming) in terms of particulate matter (PM), elemental and organic carbon (EC-OC) together with a detailed chemical characterization of 88 particle-bound organic species including polycyclic aromatic hydrocarbons (PAHs), levoglucosan and its isomers, lignin breakdown products (methoxyphenols), cholesterol, alkanes, polyols and sugars. Furthermore, wood-log based burning experiments have been performed to highlight key indicators or chemical patterns of both, green waste and wood burning (residential heating) sources, that may be used for PM source apportionment purposes. Two residential log wood combustion appliances, wood stove (RWS) and fireplace, under different output conditions (nominal and reduced) and wood log moisture content (mix of beech, oak and hornbeam), have been tested. Open wood burning experiments using wood logs were also performed. Green waste burning EFs obtained were comparable to the available literature data for open-air biomass burning. For PM and for most of the organic species studied, they were about 2 to 30 times higher than those observed for wood log combustion experiments. Though, poor performance wood combustions (open-air wood log burning, fireplace and RWS in reduced output) showed comparable EFs for levoglucosan and its isomers, methoxyphenols, polyols, PAHs and sugars. Toxic PAH equivalent benzo[a]pyrene EFs were even 3-10 times higher for the fireplace and open-air wood log burning. These results highlighted the impact of the nature of the fuel burnt and the combustion performances on the emissions. Different chemical fingerprints between both biomass burning sources were highlighted with notably a predominance of odd high-molecular weight n-alkanes (higher carbon preference index, CPI), lower levoglucosan/mannosan ratio and lower sinapylaldehyde abundance for green waste burning. However, the use of such indicators seems limited, especially if applied alone, for a clear discrimination of both sources in ambient air.


Assuntos
Poluentes Atmosféricos , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Atmosféricos/análise , Carvão Mineral/análise , Jardins , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Madeira/química
14.
Anal Chem ; 82(3): 1054-65, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20041683

RESUMO

A new hardware solution is proposed that allows one to automatically change the length of a chromatographic bed. The setup is based on the serial coupling of chromatographic columns using two rotor-stator valves (with N positions, N + 1 ports). Despite the use of a prototype setup requiring rather long connection tubing, only 9% loss in efficiency is observed for compounds with a retention factor above 4 compared to the efficiency expected on the basis of the individual column results. It has been demonstrated for a number of isocratic and gradient separations that the system allows one to realize considerable analysis time savings by adapting the total column length to the specific sample requirements and/or to the stage of method development wherein one is working. During method development, a separation on a short column length can first be used to rapidly gain insight into the composition of the sample, leaving fewer runs to be done on a column of maximal length (offering efficiencies that are inaccessible with individual column systems). The ease with which information can be obtained on columns of different lengths can furthermore be exploited for screening purposes to detect coeluting components in a stage wherein they still appear completely unresolved (i.e., have a resolution well below R(s) = 0.5).


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Citocromos c/análise , Automação , Citocromos c/isolamento & purificação , Cinética
15.
RSC Adv ; 10(20): 11907-11917, 2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-35496617

RESUMO

Vehicle gas is often compressed to about 200 bar at the refueling station prior to charging to the vehicle's tank. If a high amount of oil is carried over to the gas, it may cause damage to the vehicles; it is therefore necessary to accurately measure oil carryover. In this paper, three analytical methods for accurate quantification of the oil content are presented whereby two methods are based on gas chromatography and one on FTIR. To better evaluate the level of complexity of the matrix, 10 different compressor oils in use at different refueling stations were initially collected and analysed with GC and FTIR to identify their analytical traces. The GC traces could be divided into three different profiles: oils exhibiting some well resolved peaks, oils exhibiting globally unresolved peaks with some dominant peaks on top of the hump and oils exhibiting globally unresolved peaks. After selection of three oils; one oil from each type, the three methods were evaluated with regards to the detection and quantification limits, the working range, precision, trueness and robustness. The evaluation of the three measurement methods demonstrated that any of these three methods presented were suitable for the quantification of compressor oil for samples. The FTIR method and the GC/MS method both resulted in measurement uncertainties close to 20% rel. while the GC/FID method resulted in a higher measurement uncertainty (U = 30% rel.).

16.
J Chromatogr A ; 1212(1-2): 23-34, 2008 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-18952223

RESUMO

The present paper reports on the possibility to use the kinetic plot method (KPM) to select and design the best possible system to achieve a given number (100,000) of theoretical plates for a pharmaceutical test mixture, using the information obtained from a series of single column performance measurements of sub-2microm and supra-2microm porous shell particles conducted at three different temperatures and using mixtures of acetonitrile and 0.1% formic acid in water as the mobile phase. Because the KPM involves an extrapolation to different column lengths, the quality of the design was subsequently verified by coupling several columns to achieve the optimal total column length and run the actual analysis at the calculated optimal flow rate. The prediction error was generally better than 10%, with a slightly better prediction for t(0) and N than for the retention time t(R). The sub-2microm and the porous shell particle coupled column systems achieve the 100,000 plates about equally fast, despite the fact that the former were used at 1000bar and the latter only at 600bar. The high temperature operation (80 degrees C) yielded the fastest separation in both cases, allowing to reach 100,000 plates for a component eluting at k'=2.5 in only about 15min.


Assuntos
Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Acetonitrilas/química , Desenho de Equipamento , Formiatos/química , Cinética , Tamanho da Partícula , Pressão , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
17.
J Chromatogr A ; 1138(1-2): 120-31, 2007 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-17097097

RESUMO

Theoretical aspects of temperature in liquid chromatography (LC) have mostly been studied to elucidate changes in retention behavior of small and large molecules in various solvents. That temperature also plays a significant role in chromatographic performance is less known. Kinetic plots are an established tool to predict chromatographic performance in terms of speed and efficiency that can be obtained with a certain particle size at the maximum attainable column pressure. In this paper, temperature effects on mobile phase viscosity and analyte diffusion are incorporated in these plots to prove that superior performances are within experimental reach for conventional LC columns and equipment. Verification of the modified kinetic plots with experimental data points is presented.


Assuntos
Cromatografia Líquida/instrumentação , Temperatura , Cromatografia Líquida/métodos , Cinética , Reprodutibilidade dos Testes
19.
Sci Total Environ ; 607-608: 243-252, 2017 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-28692894

RESUMO

The occurrence and spatial distribution of 22 selected perfluoroalkyl and polyfluoroalkyl substances (PFASs) in surface water (n=75), groundwater (n=80) and surficial sediment (n=15) were investigated for the first time in the tropical areas constituted by the French Overseas Territories (French Guiana, Guadeloupe, Martinique, Mayotte and Reunion). Descriptive statistics and correlations between PFASs were evaluated through the use of specific statistical treatments to handle left-censored data ("non-detects"). PFASs were ubiquitous in these samples and detection frequencies as high as 79% for perfluorooctane sulfonate (PFOS) and 65% for perfluorooctanoate (PFOA) were reported in surface waters. ∑PFASs was in the range

20.
J Chromatogr A ; 1109(2): 191-6, 2006 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-16480728

RESUMO

High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.


Assuntos
Cromatografia Líquida/instrumentação , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA