1.
Sensors (Basel) ; 21(3)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525501

RESUMO

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

2.
Opt Lett ; 44(10): 2514-2517, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-31090720

RESUMO

We propose an adaptive optics light-sheet fluorescence microscope (AO-LSFM) for closed-loop aberrations' correction at the emission path, providing intrinsic instrumental simplicity and high accuracy when compared to previously reported schemes. The approach is based on direct wavefront sensing, i.e., not on time-consuming iterative algorithms, and does not require the use of any guide star, thus reducing instrumental complexity and/or sample preparation constraints. The design is based on a modified Shack-Hartmann wavefront sensor providing compatibility with extended sources such as images from optical sectioning microscopes. We report an AO-LSFM setup based on such sensors, including characterization of the sensor performance, and demonstrate for the first time to the best of our knowledge a significant contrast improvement on neuronal structures of the ex vivo adult drosophila brain in depth.

3.
Opt Express ; 26(24): 31299-31306, 2018 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-30650718

RESUMO

The wavefront quality of white-light supercontinuum is crucial for applications like waveform synthesis or imaging. It has been here generated by 1030 nm centered sub-picosecond pulses in YAG and characterized with a Shack-Hartmann wavefront sensor across different parts of the spectrum. It shows a good wavefront quality of λ/11 and little dependence on the wavelength of the supercontinuum. The wavefront deformations are transferred from the driver laser wavefront to the supercontinuum independently of the wavelength.

4.
Sci Rep ; 12(1): 9577, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688890

RESUMO

We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.


Assuntos
Pupila , Retina , Humanos , Oftalmoscopia/métodos , Óptica e Fotônica , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
5.
Methods Protoc ; 2(3)2019 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-31336779

RESUMO

High-quality in-depth imaging of three-dimensional samples remains a major challenge in modern microscopy. Selective plane illumination microscopy (SPIM) is a widely used technique that enables imaging of living tissues with subcellular resolution. However, scattering, absorption, and optical aberrations limit the depth at which useful imaging can be done. Adaptive optics (AOs) is a method capable of measuring and correcting aberrations in different kinds of fluorescence microscopes, thereby improving the performance of the optical system. We have incorporated a wavefront sensor adaptive optics scheme to SPIM (WAOSPIM) to correct aberrations induced by optically-thick samples, such as multi-cellular tumor spheroids (MCTS). Two-photon fluorescence provides us with a tool to produce a weak non-linear guide star (NGS) in any region of the field of view. The faintness of NGS; however, led us to develop a high-sensitivity Shack-Hartmann wavefront sensor (SHWS). This paper describes this newly developed SHWS and shows the correction capabilities of WAOSPIM using NGS in thick, inhomogeneous samples like MCTS. We report improvements of up to 79% for spatial frequencies corresponding to cellular and subcellular size features.

6.
Biomed Opt Express ; 9(4): 1871-1892, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675326

RESUMO

Imaging of the human retina with high resolution is an essential step towards improved diagnosis and treatment control. In this paper, we introduce a compact, clinically user-friendly instrument based on swept source optical coherence tomography (SS-OCT). A key feature of the system is the realization of two different operation modes. The first operation mode is similar to conventional OCT imaging and provides large field of view (FoV) images (up to 45° × 30°) of the human retina and choroid with standard resolution. The second operation mode enables it to optically zoom into regions of interest with high transverse resolution using adaptive optics (AO). The FoV of this second operation mode (AO-OCT mode) is 3.0° × 2.8° and enables the visualization of individual retinal cells such as cone photoreceptors or choriocapillaris. The OCT engine is based on an akinetic swept source at 1060 nm and provides an A-scan rate of 200 kHz. Structural as well as angiographic information can be retrieved from the retina and choroid in both operational modes. The capabilities of the prototype are demonstrated in healthy and diseased eyes.

7.
Biomed Opt Express ; 7(5): 1783-96, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27231621

RESUMO

We present a new compact multi-modal imaging prototype that combines an adaptive optics (AO) fundus camera with AO-optical coherence tomography (OCT) in a single instrument. The prototype allows acquiring AO fundus images with a field of view of 4°x4° and with a frame rate of 10fps. The exposure time of a single image is 10 ms. The short exposure time results in nearly motion artifact-free high resolution images of the retina. The AO-OCT mode allows acquiring volumetric data of the retina at 200kHz A-scan rate with a transverse resolution of ~4 µm and an axial resolution of ~5 µm. OCT imaging is acquired within a field of view of 2°x2° located at the central part of the AO fundus image. Recording of OCT volume data takes 0.8 seconds. The performance of the new system is tested in healthy volunteers and patients with retinal diseases.

8.
Biomed Opt Express ; 3(2): 225-39, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22312577

RESUMO

Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics.

9.
Biomed Opt Express ; 2(11): 3135-49, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22076274

RESUMO

We demonstrate that sample induced aberrations can be measured in a nonlinear microscope. This uses the fact that two-photon excited fluorescence naturally produces a localized point source inside the sample: the nonlinear guide-star (NL-GS). The wavefront emitted from the NL-GS can then be recorded using a Shack-Hartmann sensor. Compensation of the recorded sample aberrations is performed by the deformable mirror in a single-step. This technique is applied to fixed and in vivo biological samples, showing, in some cases, more than one order of magnitude improvement in the total collected signal intensity.

10.
J Synchrotron Radiat ; 15(Pt 2): 134-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18296778

RESUMO

The recent development of short-wavelength optics (X/EUV, synchrotrons) requires improved metrology techniques in terms of accuracy and curvature dynamic range. In this article a stitching Shack-Hartmann head dedicated to be mounted on translation stages for the characterization of X-ray mirrors is presented. The principle of the instrument is described and experimental results for an X-ray toroidal mirror are presented. Submicroradian performances can be achieved and systematic comparison with a classical long-trace profiler is presented. The accuracy and wide dynamic range of the Shack-Hartmann long-trace-profiler head allow two-dimensional characterizations of surface figure and curvature with a submillimeter spatial resolution.

11.
Opt Lett ; 31(2): 199-201, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441029

RESUMO

We present what we believe to be the first automatic alignment of a synchrotron beamline by the Hartmann technique. Experiments were performed, in the soft-x-ray range (E=3 keV, lambda=0.414 nm), by using a four-actuator Kirkpatrick-Baez (KB) active optic. A system imaging the KB focal spot and a soft-x-ray Hartmann wavefront sensor were used alternatively to control the KB optic. The beam corrected with the help of the imaging system was used to calibrate the wavefront sensor. With both closed loops, we focused the beam into a 6.8 microm x 9 microm FWHM focal spot.

12.
Opt Lett ; 28(17): 1534-6, 2003 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12956370

RESUMO

We report, for the first time to our knowledge, experimental demonstration of wave-front analysis via the Hartmann technique in the extreme ultraviolet range. The reference wave front needed to calibrate the sensor was generated by spatially filtering a focused undulator beam with 1.7- and 0.6-microm-diameter pinholes. To fully characterize the sensor, accuracy and sensitivity measurements were performed. The incident beam's wavelength was varied from 7 to 25 nm. Measurements of accuracy better than lambdaEUV/120 (0.11 nm) were obtained at lambdaEUV = 13.4 nm. The aberrations introduced by an additional thin mirror, as well as wave front of the spatially unfiltered incident beam, were also measured.