Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Gastroenterol ; 24(1): 176, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773485

RESUMO

BACKGROUND: Angiogenesis is a critical step in colorectal cancer growth, progression and metastasization. CT are routine imaging examinations for preoperative clinical evaluation in colorectal cancer patients. This study aimed to investigate the predictive value of preoperative CT enhancement rate (CER) and CT perfusion parameters on angiogenesis in colorectal cancer, as well as the association of preoperative CER and CT perfusion parameters with serum markers. METHODS: This retrospective analysis included 42 patients with colorectal adenocarcinoma. Median of microvessel density (MVD) as the cut-off value, it divided 42 patients into high-density group (MVD ≥ 35/field, n = 24) and low-density group (MVD < 35/field, n = 18), and 25 patients with benign colorectal lesions were collected as the control group. Statistical analysis of CER, CT perfusion parameters, serum markers were performed in all groups. Receiver operating curves (ROC) were plotted to evaluate the diagnostic efficacy of relevant CT perfusion parameters for tumor angiogenesis; Pearson correlation analysis explored potential association between CER, CT perfusion parameters and serum markers. RESULTS: CER, blood volume (BV), blood flow (BF), permeability surface (PS) and carbohydrate antigen 19 - 9 (CA19-9), carbohydrate antigen 125 (CA125), carcinoembryonic antigen (CEA), trefoil factor 3 (TFF3), vascular endothelial growth factor (VEGF) in colorectal adenocarcinoma were significantly higher than those in the control group, the parameters in high-density group were significantly higher than those in the low-density group (P < 0.05); however, the time to peak (TTP) of patients in colorectal adenocarcinoma were significantly lower than those in the control group, and the high-density group showed a significantly lower level compared to the low-density group (P < 0.05). The combined parameters BF + TTP + PS and BV + BF + TTP + PS demonstrated the highest area under the curve (AUC), both at 0.991. Pearson correlation analysis showed that the serum levels of CA19-9, CA125, CEA, TFF3, and VEGF in patients showed positive correlations with CER, BV, BF, and PS (P < 0.05), while these indicators exhibited negative correlations with TTP (P < 0.05). CONCLUSIONS: Some single and joint preoperative CT perfusion parameters can accurately predict tumor angiogenesis in colorectal adenocarcinoma. Preoperative CER and CT perfusion parameters have certain association with serum markers.


Assuntos
Adenocarcinoma , Antígeno Carcinoembrionário , Neoplasias Colorretais , Neovascularização Patológica , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/sangue , Neoplasias Colorretais/patologia , Neoplasias Colorretais/irrigação sanguínea , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/sangue , Adenocarcinoma/patologia , Adenocarcinoma/irrigação sanguínea , Idoso , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/sangue , Tomografia Computadorizada por Raios X/métodos , Antígeno Carcinoembrionário/sangue , Biomarcadores Tumorais/sangue , Adulto , Densidade Microvascular , Antígeno CA-19-9/sangue , Curva ROC , Fator A de Crescimento do Endotélio Vascular/sangue , Volume Sanguíneo , Cuidados Pré-Operatórios/métodos
2.
BMC Med Imaging ; 24(1): 116, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773384

RESUMO

OBJECTIVE: Evaluation of the predictive value of one-stop energy spectrum and perfusion CT parameters for microvessel density (MVD) in colorectal cancer cancer foci. METHODS: Clinical and CT data of 82 patients with colorectal cancer confirmed by preoperative colonoscopy or surgical pathology in our hospital from September 2019 to November 2022 were collected and analyzed retrospectively. Energy spectrum CT images were measured using the Protocols general module of the GSI Viewer software of the GE AW 4.7 post-processing workstation to measure the CT values of the arterial and venous phase lesions and the neighboring normal intestinal wall in a single energy range of 40 kev∼140 kev, and the slopes of the energy spectrum curves (λ) were calculated between 40 kev-90 kev; Iodine concentration (IC), Water concentration (WC), Effective-Z (Eff-Z) and Normalized iodine concentration (NIC) were measured by placing a region of interest (ROI) on the iodine concentration map and water concentration map at the lesion and adjacent to the normal intestinal wall.Perfusion CT images were scanned continuously and dynamically using GSI Perfusion software and analyzed by applying CT Perfusion 4.0 software.Blood volume (BV), blood flow (BF), surface permeability (PS), time to peak (TTP), and mean transit time (MTT) were measured respectively in the lesion and adjacent normal colorectal wall. Based on the pathological findings, the tumors were divided into a low MVD group (MVD < 35/field of view, n = 52 cases) and a high MVD group (MVD ≥ 35/field of view, n = 30 cases) using a median of 35/field of view as the MVD grouping criterion. The collected data were statistically analyzed, the subjects' operating characteristic curve (ROC) was plotted, and the area under curve (AUC), sensitivity, specificity, and Yoden index were calculated for the predicted efficacy of each parameter of the energy spectrum and perfusion CT and the combined parameters. RESULTS: The CT values, IC, NIC, λ, Eff-Z of 40kev∼140kev single energy in the arterial and venous phase of colorectal cancer in the high MVD group were higher than those in the low MVD group, and the differences were all statistically significant (p < 0.05). The AUC of each single-energy CT value in the arterial phase from 40 kev to 120 kev for determining the high or low MVD of colorectal cancer was greater than 0.8, indicating that arterial stage has a good predictive value for high or low MVD in colorectal cancer; AUC for arterial IC, NIC and IC + NIC were all greater than 0.9, indicating that in arterial colorectal cancer, both single and combined parameters of spectral CT are highly effective in predicting the level of MVD. The AUC of 40 kev to 90 kev single-energy CT values in the intravenous phase was greater than 0.9, and its diagnostic efficacy was more representative; The AUC of IC and NIC in venous stage were greater than 0.8, which indicating that the IC and NIC energy spectrum parameters in venous stage colorectal cancer have a very good predictive value for the difference between high and low MVDs, with the greatest diagnostic efficacy in IC.The values of BV and BF in the high MVD group were higher than those in the low MVD group, and the differences were statistically significant (P < 0.05), and the AUC of BF, BV, and BV + BF were 0.991, 0.733, and 0.997, respectively, with the highest diagnostic efficacy for determining the level of MVD in colorectal cancer by BV + BF. CONCLUSION: One-stop CT energy spectrum and perfusion imaging technology can accurately reflect the MVD in living tumor tissues, which in turn reflects the tumor angiogenesis, and to a certain extent helps to determine the malignancy, invasion and metastasis of living colorectal cancer tumor tissues based on CT energy spectrum and perfusion parameters.


Assuntos
Neovascularização Patológica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neovascularização Patológica/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/irrigação sanguínea , Neoplasias Retais/patologia , Idoso de 80 Anos ou mais , Densidade Microvascular , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/irrigação sanguínea , Neoplasias Colorretais/patologia , Valor Preditivo dos Testes , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/irrigação sanguínea , Angiogênese
3.
Int J Colorectal Dis ; 37(9): 2021-2029, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35997991

RESUMO

OBJECTIVES: To evaluate the value of preoperative CT energy spectrum imaging in detecting lymph node metastasis of colorectal cancer. METHODS: From September 2019 to November 2021, a retrospective study was performed for the eighty-two patients with colorectal cancer through preoperative colonoscopy or surgical pathology confirmed in our hospital. Based on the lymph node metastasis status, these cases were divided into the metastasis and non-metastasis groups. GE Revolution CT scanner was used to scan the patients with energy spectrum imaging, it measured and recorded the single-energy CT values from 40 to 140 keV and various energy spectrum parameters of lymph nodes around the lesions in the arterial and venous phases, and statistically analyze the above indices. RESULTS: In the arterial and venous phases: the single-energy CT values of 40-140 keV in the non-metastatic group were higher than those in the metastatic group (all P < 0.05); the parameter values of IC (iodine concentration), NIC (normalized iodine concentration), λ (the slope of the energy spectrum curve), and Eff-Z (effective-Z) in the non-metastatic group were higher than those in the metastatic group (all P < 0.05). Further evaluation of ROC curve showed that the higher AUC (area under curve) of the single-energy CT value of 50 keV in the arterial phase was 0.889, among the energy spectrum parameters of IC, NIC, λ, and Eff-Z, the NIC had the better diagnostic efficiency and the AUC of the NIC was 0.873, the highest AUC of the combination of NIC and λ was 0.885 when the energy spectrum parameters were combined. The higher AUC of the single-energy CT value of 60 keV in the venous phase was 0.853, among the energy spectrum parameters of IC, NIC, λ, and Eff-Z, the λ had the better diagnostic efficiency and the AUC of the λ was 0.822, the higher AUC of the combination of NIC, λ, and Eff-Z was 0.840 when the energy spectra were combined. CONCLUSIONS: Parameters of energy spectrum CT imaging can effectively evaluate whether lymph nodes have metastases, and provide favorable imaging diagnosis basis for the range and the number of lymph nodes to be cleaned during clinical operation and can evaluate the prognosis of patients. It is worthy of clinical recommendation.


Assuntos
Neoplasias Colorretais , Iodo , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA