Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Osteoarthritis Cartilage ; 31(9): 1242-1248, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37209993

RESUMO

PURPOSE: To compare the evaluation metrics for deep learning methods that were developed using imbalanced imaging data in osteoarthritis studies. MATERIALS AND METHODS: This retrospective study utilized 2996 sagittal intermediate-weighted fat-suppressed knee MRIs with MRI Osteoarthritis Knee Score readings from 2467 participants in the Osteoarthritis Initiative study. We obtained probabilities of the presence of bone marrow lesions (BMLs) from MRIs in the testing dataset at the sub-region (15 sub-regions), compartment, and whole-knee levels based on the trained deep learning models. We compared different evaluation metrics (e.g., receiver operating characteristic (ROC) and precision-recall (PR) curves) in the testing dataset with various class ratios (presence of BMLs vs. absence of BMLs) at these three data levels to assess the model's performance. RESULTS: In a subregion with an extremely high imbalance ratio, the model achieved a ROC-AUC of 0.84, a PR-AUC of 0.10, a sensitivity of 0, and a specificity of 1. CONCLUSION: The commonly used ROC curve is not sufficiently informative, especially in the case of imbalanced data. We provide the following practical suggestions based on our data analysis: 1) ROC-AUC is recommended for balanced data, 2) PR-AUC should be used for moderately imbalanced data (i.e., when the proportion of the minor class is above 5% and less than 50%), and 3) for severely imbalanced data (i.e., when the proportion of the minor class is below 5%), it is not practical to apply a deep learning model, even with the application of techniques addressing imbalanced data issues.


Assuntos
Doenças das Cartilagens , Aprendizado Profundo , Osteoartrite do Joelho , Humanos , Estudos Retrospectivos , Benchmarking , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Doenças das Cartilagens/patologia
2.
J Biomech Eng ; 145(8)2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36628998

RESUMO

The carpal tunnel is a tightly bounded space, making the median nerve prone to compression and eventually leading to carpal tunnel syndrome. Carpal tunnel release surgery transects the transverse carpal ligament to expand the tunnel arch space, decompress the median nerve, and relieve the associated symptoms. However, the surgical procedure unavoidably disrupts essential anatomical, biomechanical and physiological functions of the wrist, potentially causing reduced grip strength, pillar pain, carpal bone instability, scar tissue formation, and perineural fibrosis. It is desirable to decompress the median nerve without surgically transecting the transverse carpal ligament. This paper is to review several approaches we have developed for nonsurgical carpal arch space augmentation (CASA), namely, radio ulnar wrist compression, muscle-ligament interaction, palmar pulling, and collagenolysis of the transverse carpal ligament. Briefly summarized is the research work on the CASA topic about theoretical considerations, in vitro and in situ experiment, computational modeling, and human subject studies with asymptomatic and carpal tunnel syndrome hands.


Assuntos
Ossos do Carpo , Síndrome do Túnel Carpal , Humanos , Síndrome do Túnel Carpal/cirurgia , Nervo Mediano/cirurgia , Ligamentos Articulares , Descompressão
3.
J Biomech Eng ; 145(3)2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36416297

RESUMO

The spacing between the median nerve and transverse carpal ligament (TCL) within the carpal tunnel can potentially affect the nerve morphology. This study aimed to quantify the spatial relationship between the median nerve and transverse carpal ligament in asymptomatic hands. Twelve subjects were recruited to image the carpal tunnel using robot-assisted ultrasound. The median nerve and TCL were segmented from each image and three-dimensionally reconstructed using kinematic information from the robot. The TCL-median nerve distance, nerve cross-sectional area, circularity, and position were measured along the entirety of the nerve length within the carpal tunnel. Results were averaged at every 5% of nerve length. At the nerve length percentages of 0% (distal), 25%, 50%, 75%, and 100% (proximal), the TCL-median nerve distance (±SD) was 0.7 ± 0.4, 0.7 ± 0.2, 0.5 ± 0.2, 0.5 ± 0.2, and 0.6 ± 0.3 mm, respectively. The corresponding nerve cross-sectional area was 9.4 ± 1.9, 10.6 ± 2.6, 11.2 ± 2.1, 11.2 ± 1.7, and 9.7 ± 1.9 mm2. A one-way analysis of variance showed no significant differences between the respective percentages of nerve length for TCL-median nerve distance (p = 0.219) and cross-sectional area (p = 0.869). Significant (p < 0.0001) but weak correlations were observed between the TCL-median nerve distance with cross-sectional area (r = -0.247) and circularity (r = -0.244). This study shows that the healthy median nerve morphology is consistent along the continuous nerve length within the carpal tunnel, supporting the use of 2D imaging in the evaluation of the healthy nerve.


Assuntos
Síndrome do Túnel Carpal , Nervo Mediano , Humanos , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/anatomia & histologia , Síndrome do Túnel Carpal/diagnóstico por imagem , Ligamentos Articulares , Articulação do Punho , Mãos/fisiologia
4.
Surg Endosc ; 36(7): 4932-4938, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34845555

RESUMO

AIM: To evaluate the efficacy and safety of brachytherapy with double-strand 125I seeds and biliary drainage for malignant obstructive jaundice. METHODS AND MATERIALS: 42 patients with obstructive jaundice because of extrahepatic cholangiocarcinoma were enrolled. 22 patients (group A) received a biliary stent with common drainage tube implantation, and 20 patients (group B) received a biliary stent with double-strand 125I seeds radiotherapy drainage tube placement. The length, location and pathological stage of biliary stricture were recorded in the two groups. Total bilirubin (TBIL), direct bilirubin (DBIL), IgA, IgG, IgM, alanine aminotransferase and white blood cell (WBC) count were measured before and after percutaneous transhepatic cholangial drainage (PTCD). Tumor diameter was measured before and three months after PTCD, and the difference were calculated. Stent patency time, survival time, and complications were recorded. RESULTS: There was no significant difference in the length, location and pathological stage of biliary stenosis between the two groups. There was no significant difference in TBIL, DBIL, IgA, IgG, IgM, alanine aminotransferase and WBC count between the two groups before or after PTCD (P > 0.05). Three months after PTCD, tumors growth in group A and tumors shrinkage in group B. The difference in tumor size between the two groups before and after PTCD was statistically significant (P < 0.05). The average stent patency times in groups A and B were 3.55 ± 0.76 months and 8.76 ± 1.85 months, respectively (P < 0.05). The average survival times in groups A and B were 133.5 ± 27.8 days and 252.5 ± 114.5 days, respectively (P < 0.05). There was no statistically significant difference in the incidence of complications between the two groups (P > 0.05). CONCLUSION: Double-strand 125I seeds radiotherapy biliary drainage tubes can safely and effectively control tumors, prolong the patency of biliary stents, and prolong patient survival.


Assuntos
Neoplasias dos Ductos Biliares , Braquiterapia , Colestase , Icterícia Obstrutiva , Alanina Transaminase , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/radioterapia , Ductos Biliares Intra-Hepáticos , Bilirrubina , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Drenagem/métodos , Humanos , Imunoglobulina A , Imunoglobulina G , Imunoglobulina M , Radioisótopos do Iodo , Icterícia Obstrutiva/etiologia , Stents/efeitos adversos , Resultado do Tratamento
5.
BMC Musculoskelet Disord ; 23(1): 971, 2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36352375

RESUMO

Previous studies have shown radioulnar wrist compression augments carpal arch space. This study investigated the effects of radioulnar wrist compression on patient-reported outcomes associated with carpal tunnel syndrome. Subjects underwent thrice-daily (15 min each time 45 min daily) wrist compression over 4 weeks with an additional four weeks of follow-up without treatment. Primary outcomes included Boston Carpal Tunnel Questionnaire symptom and functional severity scales (SSS and FSS) and symptoms of numbness/tingling based on Visual Analog Scales. Our results showed that radioulnar wrist compression improved SSS by 0.55 points after 2 weeks (p < 0.001) and 0.51 points at 4 weeks (p < 0.006) compared to the baseline scale. At the four-week follow-up, SSS remined improved at 0.47 points (p < 0.05). Symptoms of numbness/tingling improved at two and 4 weeks, as well as the follow-up (p < 0.05). Hand motor impairment such as weakness had a lower frequency across carpal tunnel syndrome sufferers and does not significantly improve (p > 0.05). Radioulnar wrist compression might be an effective alternative treatment in improving sensory related symptoms in patients with mild to moderate carpal tunnel syndrome.


Assuntos
Síndrome do Túnel Carpal , Humanos , Síndrome do Túnel Carpal/complicações , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/terapia , Punho , Hipestesia/diagnóstico , Hipestesia/etiologia , Articulação do Punho , Medidas de Resultados Relatados pelo Paciente
6.
J Neuroeng Rehabil ; 19(1): 121, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36357939

RESUMO

This study aimed to investigate the effects of early-stage Alzheimer's disease (AD) on the reach-to-grasp kinematics and kinetics with and without visual supervision of the grasping arm and hand. Seventeen patients who had been diagnosed with early-stage AD and 17 age- and gender-matched, cognitive normal (CN) adults participated in the experiment. A mirror operating system was designed to block the visual feedback of their grasping hand and forearms but to virtually show grasped targets. The target for reach-to-grasp kinematics was a reflective marker installed on a base; and the target for reach-to-grasp kinetics was a custom-made apparatus installed with two six-component force/torque transducers. Kinematics and kinetic parameters were used to quantify the reach-to-grasp performances. Results showed that the early-stage AD remarkably decreased the reaching speed, reduced the grasping accuracy and increased the transportation variability for reach-to-grasp kinematics. For kinetic analysis, early-stage AD extended the preload duration, disturbed the grip and lift forces coordination, and increased the feedforward proportion in the grasping force control. The AD-related changes in the reach-to-grasp kinematic and kinetic parameters depended on visual feedback and were associated with nervous system function according to correlation analyses with the neuropsychological testing. These results suggest that the abnormal kinematic and kinetic characteristics may correlate with the neuropsychological status of early-stage AD, and that the reach-to-grasp kinematic and kinetic maneuver could potentially be used as a novel tool for non-invasive screening or evaluation of early-stage AD.


Assuntos
Doença de Alzheimer , Retroalimentação Sensorial , Adulto , Humanos , Retroalimentação Sensorial/fisiologia , Fenômenos Biomecânicos/fisiologia , Força da Mão/fisiologia , Desempenho Psicomotor/fisiologia , Cinética , Mãos/fisiologia , Movimento/fisiologia
7.
J Hand Surg Am ; 47(2): 187.e1-187.e13, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34049729

RESUMO

PURPOSE: Wrist circumduction is increasingly used as a functional motion assessment for patients. Thus, increasing our understanding of its relation to the functional motion envelope is valuable. Previous studies have shown that the wrist is preferentially extended during hand activities of daily living (ADLs), with greater ulnar than radial deviation. The purpose of this study was to characterize the functional wrist motions of 22 modern ADLs in healthy subjects. We hypothesized that the subjects would perform ADLs predominantly in ulnar extension. METHODS: Ten right-handed, healthy subjects performed flexion-extension, radioulnar deviation, maximal circumduction, and 22 modern ADLs. Angular wrist positions were obtained by tracking retroreflective markers on the hand and forearm. Angular motion data were analyzed with a custom program for peak/trough angles in flexion extension and radioulnar deviation, ellipse area of circumduction data, and ellipse area of combined motion data. RESULTS: The required ranges of motion for ADLs were from 46.6° ± 16.5° of flexion (stirring task) to 63.8° ± 14.2° of extension (combing) in flexion-extension and from 15.6° ± 8.9° of radial deviation (opening a jar) to 32.5° ± 8.3° of ulnar deviation (picking up smartphone) in radioulnar deviation. Ellipse area of combined motion data of the 22 ADLs were, on average, 58.2% ± 14.3% of the ellipse area of maximal circumduction. A motion data quadrantal analysis revealed that 54.9% of all ADL wrist motion occurred in ulnar extension. Among the average wrist positions for 22 ADLs, 16 were located in the ulnar extension quadrant. CONCLUSIONS: This study revealed a functional wrist motion envelope that was less than 60% of wrist maximal motion capacity on average. Our results also showed that the majority of ADLs are performed in ulnar extension of the wrist. CLINICAL RELEVANCE: Baseline values for healthy subjects performing 22 wrist ADLs can inform future studies assessing dysfunction, postsurgical changes, and rehabilitation progress.


Assuntos
Atividades Cotidianas , Punho , Fenômenos Biomecânicos , Humanos , Amplitude de Movimento Articular , Ulna , Articulação do Punho
8.
J Biomech Eng ; 143(10)2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33938948

RESUMO

This study investigated the biomechanical effects of thenar muscles (abductor pollicis brevis (APB), superficial head of flexor pollicis brevis (sFPB), opponens pollicis (OPP)) on the transverse carpal ligament formed carpal arch under force application by individual or combined muscles (APB, sFPB, OPP, APB-sFPB, sFPB-OPP, APB-OPP, and APB-sFPB-OPP). In ten cadaveric hands, thenar muscles were loaded under 15% of their respective maximal force capacity, and ultrasound images of the cross section of the distal carpal tunnel were collected for morphometric analyses of the carpal arch. The carpal arch height and area were significantly dependent on the loading condition (p < 0.01), muscle combination (p < 0.05), and their interaction (p < 0.01). The changes to arch height and area were significantly dependent on the muscle combinations (p = 0.001 and p < 0.001, respectively). The arch height and area increased under the loading combinations of APB, OPP, APB-sFPB, APB-OPP, or APB-sFPB-OPP (p < 0.05), but not under the combinations of sFPB (p = 0.893) or sFPB-OPP (p = 0.338). The carpal arch change under the APB-sFPB-OPP or APB-OPP loading was greater than that under the loading of APB-sFPB (p < 0.001). This study demonstrated that thenar muscle forces exert biomechanical effects on the transverse carpal ligament to increase carpal arch height and area, and these increases were different for individual muscles and their combinations.


Assuntos
Músculo Esquelético
9.
Muscle Nerve ; 62(4): 522-527, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32644200

RESUMO

INTRODUCTION: The purpose of this study was to investigate in vivo median nerve longitudinal mobility in different segments of the carpal tunnel associated with active finger motion in carpal tunnel syndrome (CTS) patients in a comparison with healthy controls. METHODS: Eleven healthy volunteers and 11 CTS patients participated in this study. Dynamic ultrasound images captured location-dependent longitudinal median nerve mobility within the carpal tunnel during finger flexion at the metacarpophalangeal joints using a speckle cross-correlation algorithm. RESULTS: Median nerve longitudinal mobility in the carpal tunnel was significantly smaller in CTS patients (0.0037 ± 0.0011 mm/degree) compared with controls (0.0082 ± 0.0026 mm/degree) (P < .05), especially in the proximal (0.0064 vs 0.0132 mm/degree on average) and middle (0.0033 vs 0.0074 mm/degree on average) carpal tunnel sections. DISCUSSION: Median nerve mobility can potentially serve as a biomechanical marker when diagnosing CTS, or when assessing the effectiveness of surgical and conservative treatments.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Nervo Mediano/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Síndrome do Túnel Carpal/diagnóstico por imagem , Feminino , Humanos , Masculino , Nervo Mediano/diagnóstico por imagem , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Ultrassonografia
10.
J Biomech Eng ; 142(9)2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32110808

RESUMO

The carpal tunnel is geometrically irregular due to the complex composition of many carpal bones intercalated by numerous intercarpal ligaments. The purpose of the study was to investigate the relative contributions of the ligament and bone arches to carpal tunnel space at the proximal, middle, and distal tunnel regions. A catheter ultrasound probe acquired fan-like images inside cadaveric carpal tunnels for three-dimensional reconstruction of the tunnel. The total tunnel volume was 5367.6 ± 940.1 mm3 with contributions of 12.0%, 6.9%, and 4.1% by proximal, middle, and distal ligament arches, respectively, and 27.0%, 25.3%, and 24.7% by proximal, middle, and distal bone arches, respectively. The bone arch occupied more tunnel space than the ligament arch at all regions (p < 0.05). The ligament arch was largest at the proximal region of the tunnel and significantly decreased toward the distal region (p < 0.05). However, the bone arch significantly decreased only from the proximal to middle region (p < 0.05) but not from the middle to distal region (p = 0.311). Consequently, it was observed that the ligament arch was the key contributor to the unequal carpal tunnel space across regions. Partitional and regional tunnel morphometric information may provide a better understanding of tunnel abnormality associated with various wrist pathological conditions. The developed framework of ultrasonography and data processing can be applied to other areas of interest in the musculoskeletal system.


Assuntos
Ossos do Carpo , Punho , Síndrome do Túnel Carpal , Humanos , Ligamentos Articulares , Pessoa de Meia-Idade , Ultrassonografia
11.
Clin Anat ; 33(8): 1176-1180, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31894884

RESUMO

The transverse carpal ligament (TCL), the main part of the flexor retinaculum, serves as an anchor for the thenar muscles: abductor pollicis brevis (APB), superficial head of the flexor pollicis brevis (sFPB), and opponens pollicis (OPP). Biomechanically, the thenar muscles rely on their TCL anchoring to transmit muscle contractions distally for thumb force and motion production, and reciprocally, muscle contraction interacts with the TCL at the proximal end through the origins. However, scarce knowledge exists regarding the distribution pattern of the thenar muscle origins. The purpose of this study was to understand the anatomical interface between the thenar muscles and TCL by examining the origin distributions of the individual muscles. Ten cadaveric specimens were dissected for digitization of the muscle origins and TCL volar surface. Digitized data were used for mesh reconstruction and calculation of surface areas and centroids. The origin areas for APB, sFPB, and OPP were 105.8 ± 30.3, 64.6 ± 15.2, and 245.9 ± 70.7 mm2 , respectively. The surface area of the TCL was 386.2 ± 86.9 mm2 . The origin areas of APB and OPP on the TCL were comparable, 18.4 ± 4.8% and 17.3 ± 9.6% of the TCL area, respectively. The origin locations for APB, sFPB, and OPP were in proximal-radial quadrant of the TCL, on distal aponeurosis outside the TCL, and around the ridge of trapezium, respectively. The knowledge of the anatomical interface provides a foundation for the understanding of biomechanical interactions between the muscles and ligaments and pathomechanical implications.


Assuntos
Ligamentos/anatomia & histologia , Músculo Esquelético/anatomia & histologia , Polegar/anatomia & histologia , Punho/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Biometria , Feminino , Humanos , Pessoa de Meia-Idade
13.
J Med Biol Eng ; 37(3): 328-335, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28824352

RESUMO

Carpal tunnel syndrome (CTS), caused by entrapment of the median nerve in the carpal tunnel, impairs hand function including dexterous manipulation. The purpose of this study was to investigate the effects of CTS on force coordination and muscle coherence during low-intensity sustained precision pinch while the wrist assumed different postures. Twenty subjects (10 CTS patients and 10 asymptomatic controls) participated in this study. An instrumented pinch device was used to measure the thumb and index finger forces while simultaneously collecting surface electromyographic activities of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) muscles. Subjects performed a sustained precision pinch at 10% maximum pinch force for 15 sec with the wrist stabilized at 30° extension, neutral, or 30° flexion using customized splints. The force discrepancy and the force coordination angle between the thumb and index finger forces were calculated, as well as the ß-band (15-30 Hz) coherence between APB and FDI. The index finger applied greater force than the thumb (p < 0.05); this force discrepancy was increased with wrist flexion (p < 0.05), but was not affected by CTS (p > 0.05). The directional force coordination was not significantly affected by wrist posture or CTS (p > 0.05). In general, digit force coordination during precision pinch seems to be sensitive to wrist flexion, but is not affected by CTS. The ß-band muscular coherence was increased by wrist flexion for CTS patients (p < 0.05), which could be a compensatory mechanism for the flexion-induced exacerbation of CTS symptoms. This study demonstrates that wrist flexion negatively influences muscle and force coordination in CTS patients supporting the avoidance of flexion posture for symptom exacerbation and functional performance.

14.
Acta Radiol ; 57(6): 677-83, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26377260

RESUMO

BACKGROUND: Nowadays, flat detector (FD) equipped angiographic C-arm computed tomography (CACT) systems can be used to acquire CT-like cross-sectional images directly within the interventional suite. The CACT systems offer real time visualization of transthoracic needle biopsy (TNB) procedure and more flexibility in the orientation of the detector system around the patient compared to traditional CT systems. PURPOSE: To evaluate the value of a flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy (PTNB) for small (≤3 cm) pulmonary lesions in clinical practice. MATERIAL AND METHODS: A total of 60 patients with solid lung lesions were retrospectively enrolled to undergo PTNB procedures. The mean diameter of lesions was 2.3 ± 0.6 cm (range, 0.6-3 cm). The needle path was carefully planned and calculated on the C-arm CT system, which acquired three-dimensional CT-like cross-sectional images. The PTNB procedures were performed under needle guidance with fluoroscopic feedbacks. RESULTS: Histopathologic tissue was successfully obtained from 59 patients with a puncture success rate of 98.3% (59/60). The diagnostic accuracy rate was found to be 91.5% (54/59). There were only two cases of pneumothorax (3.3%) requiring therapy. The rates of pneumothorax and hemoptysis were low (15.0% [9/60] and 8.3% [5/60], respectively). The overall procedural time was in the range of 12-18 min, resulting in a mean exposure dose of 224.4 ± 4.8 mGy. CONCLUSION: Our study shows that C-arm CT-based needle guidance enables reliable and efficient needle positioning and progression by providing real-time intraoperative guidance for small (≤3 cm) pulmonary lesions in clinical practice.


Assuntos
Biópsia Guiada por Imagem , Pneumopatias/patologia , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Feminino , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Punções , Doses de Radiação , Radiografia Torácica , Estudos Retrospectivos
15.
J Musculoskelet Res ; 19(4)2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28824216

RESUMO

The purpose of this study was to investigate the morphological and mechanical properties of the transverse carpal ligament (TCL) in patients with carpal tunnel syndrome (CTS). Thickness and stiffness of the TCL in eight female CTS patients and eight female control subjects were examined using ultrasound imaging modalities. CTS patients had a 30.9% thicker TCL than control subjects. There was no overall difference in TCL stiffness between the two groups, but the radial TCL region was significantly stiffer than the ulnar region within the CTS group and such a regional difference was not found for the controls. The increased thickness and localized stiffness of the TCL for CTS patients may contribute to CTS symptoms due to reduction in carpal tunnel space and compliance. Advancements in ultrasound technology provide a means of understanding CTS mechanisms and quantifying the morphological and mechanical properties of the TCL in vivo.

16.
Eur J Anat ; 19(1): 49-56, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25949095

RESUMO

Although the carpal tunnel is known for its anatomical constituents, its morphology is not well recognized. The aim of this study was to investigate the morphometric properties of the carpal tunnel and its surrounding structures. Magnetic resonance, cross-sectional images of the distal carpal tunnel were collected from eight cadaveric hands. Morphological analyses were performed for the cross sections of the carpal tunnel, interior carpus boundary, and exterior carpus boundary. The specimens had a carpal arch width and height of 23.9 ± 2.9 mm and 2.2 ± 0.9 mm, respectively. The carpal tunnel, interior carpus boundary, and exterior carpus boundary had perimeters of 54.8 ± 4.5 mm, 68.5 ± 7.0 mm, and 130.6 ± 11.8 mm, respectively, and areas of 183.5 ± 30.1 mm2, 240.7 ± 40.2 mm2, and 1002.3 ± 183.7 mm2, respectively. The cross sections were characterized by elliptical fitting with aspect ratios of 1.96 ± 0.15, 1.96 ± 0.19, and 1.76 ± 0.19 for the carpal tunnel, interior carpus boundary, and exterior carpus boundary, respectively. The major axis of the boundaries increased in pronation angle, relative to the hamate-trapezium axis, for the exterior carpus (6.0 ± 3.0°), interior carpus (8.2 ± 3.2°), and carpal tunnel (15.9 ± 2.2°). This study advances our understanding of the structural anatomy of the carpal tunnel, and the morphological information is valuable in the identification of structural abnormality, assistance of surgical planning, and evaluation of treatment of effects.

17.
Clin Orthop Relat Res ; 472(8): 2526-33, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24777728

RESUMO

BACKGROUND: Carpal tunnel syndrome is associated with sensory and motor impairments resulting from the compressed and malfunctioning median nerve. The thumb is critical to hand function, yet the pathokinematics of the thumb associated with carpal tunnel syndrome are not well understood. QUESTIONS/PURPOSES: The purpose of this study was to evaluate thumb motion abnormalities associated with carpal tunnel syndrome. We hypothesized that the ranges of translational and angular motion of the thumb would be reduced as a result of carpal tunnel syndrome. METHODS: Eleven patients with carpal tunnel syndrome and 11 healthy control subjects voluntarily participated in this study. Translational and angular kinematics of the thumb were obtained using marker-based video motion analysis during thumb opposition and circumduction movements. RESULTS: Motion deficits were observed for patients with carpal tunnel syndrome even though maximum pinch strength was similar. The path length, normalized by palm width of the thumb tip for the patients with carpal tunnel syndrome was less than for control participants (opposition: 2.2 palm width [95% CI, 1.8-2.6 palm width] versus 3.1 palm width [95% CI, 2.8-3.4 palm width], p < 0.001; circumduction: 2.2 palm width [95% CI, 1.9-2.5 palm width] versus 2.9 palm width [95% CI, 2.7-3.2 palm width], p < 0.001). Specifically, patients with carpal tunnel syndrome had a deficit of 0.3 palm width (95% CI, 0.04-0.52 palm width; p = 0.022) in the maximum position of their thumb tip ulnarly across the palm during opposition relative to control participants. The angular ROM also was reduced for the patients with carpal tunnel syndrome compared with the control participants in extension/flexion for the metacarpophalangeal (opposition: 34° versus 58°, p = .004; circumduction: 33° versus 58°, p < 0.001) and interphalangeal (opposition: 37° versus 62°, p = .028; circumduction: 41° versus 63°, p = .025) joints. CONCLUSIONS: Carpal tunnel syndrome disrupts kinematics of the thumb during opposition and circumduction despite normal pinch strength. CLINICAL RELEVANCE: Improving understanding of thumb pathokinematics associated with carpal tunnel syndrome may help clarify hand function impairment associated with the syndrome given the critical role of the thumb in dexterous manipulation.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Nervo Mediano/fisiopatologia , Polegar/inervação , Polegar/fisiopatologia , Adulto , Fenômenos Biomecânicos , Síndrome do Túnel Carpal/diagnóstico , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Gravação em Vídeo
18.
J Med Imaging (Bellingham) ; 11(2): 024001, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38445224

RESUMO

Purpose: Joint space width (JSW) is a common metric used to evaluate joint structure on plain radiographs. For the hand, quantitative techniques are available for evaluation of the JSW of finger joints; however, such techniques have been difficult to establish for the trapeziometacarpal (TMC) joint. This study aimed to develop a validated method for measuring the radiographic joint space of the healthy TMC joint. Approach: Computed tomographic scans were taken of 15 cadaveric hands. The location of a JSW analysis region on the articular surface of the first metacarpal was established in 3D space and standardized in a 2D projection. The standardized region was applied to simulated radiographic images. A correction factor was defined as the ratio of the CT-based and radiograph-based joint space measurements. Leave-one-out validation was used to correct the radiograph-based measurements. A t-test was used to evaluate the difference between CT-based and corrected radiograph-based measurements (α=0.05). Results: The CT-based and radiograph-based measurements of JSW were 3.61±0.72 mm and 2.18±0.40 mm, respectively. The correction factor for radiograph-based joint space was 1.69±0.41. Before correction, the difference between the CT-based and radiograph-based joint space was 1.43 mm [95% CI: 0.99-1.86 mm; p<0.001]. After correction, the difference was -0.11 mm [95% CI: -0.63-0.41 mm; p=0.669]. Conclusions: Corrected measurements of radiographic TMC JSW agreed well with CT-measured JSW. With in-vivo validation, the developed methodology has potential for automated and accurate radiographic measurement of TMC JSW.

19.
J Orthop Surg Res ; 19(1): 389, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956611

RESUMO

BACKGROUND: Elevation of carpal tunnel pressure is known to be associated with carpal tunnel syndrome. This study aimed to correlate the shear wave elastography in the transverse carpal ligament (TCL) with carpal tunnel pressures using a cadaveric model. METHODS: Eight human cadaveric hands were dissected to evacuate the tunnels. A medical balloon was inserted into each tunnel and connected to a pressure regulator to simulate tunnel pressure in the range of 0-210 mmHg with an increment of 30 mmHg. Shear wave velocity and modulus was measure in the middle of TCL. RESULTS: SWV and SWE were significantly dependent on the pressure levels (p < 0.001), and positively correlated to the tunnel pressure (SWV: R = 0.997, p < 0.001; SWE: R = 0.996, p < 0.001). Regression analyses showed linear relationship SWV and pressure (SWV = 4.359 + 0.0263 * Pressure, R2 = 0.994) and between SWE and pressure (SWE = 48.927 + 1.248 * Pressure, R2 = 0.996). CONCLUSION: The study indicated that SWV and SWE in the TCL increased linearly as the tunnel pressure increased within the current pressure range. The findings suggested that SWV/SWE in the TCL has the potential for prediction of tunnel pressure and diagnosis of carpal tunnel syndrome.


Assuntos
Cadáver , Síndrome do Túnel Carpal , Técnicas de Imagem por Elasticidade , Ligamentos Articulares , Pressão , Humanos , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
20.
Acta Radiol ; 54(6): 656-60, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23507935

RESUMO

BACKGROUND: Bronchopleural fistula (BPF) is an infrequent but life-threatening complication after pneumonectomy. The incidence of BPF reported in the literature varies from 0.3% to 20%. PURPOSE: To determine the feasibility and efficacy of using Y-shaped, single-plugged, covered, metallic stents to treat right bronchopleural fistulas. MATERIAL AND METHODS: We have designed a Y-shaped, single-plugged, covered, self-expandable, metallic airway stent to fit the specific anatomy of the right main bronchus. The stent has a main tube and two branches, resembling an inverted "Y". One of the branches is closed (plugged) and bullet-shaped; the other one tubular and open. The entire stent is encased in a nitinol wire mesh. Stent size can be individualized using multislice spiral computed tomography (MSCT) measurements of the airways. Under fluoroscopic guidance, we have implanted 15 Y-shaped stents in 15 patients with right bronchopleural fistulas. RESULTS: Stent insertion was successful in all patients. All fistulas were successfully closed immediately after stent placement. Follow-up was performed for 1-34 months. Positive clinical outcomes were seen in 13 of 15 patients. Two patients died of intractable pulmonary infection and multiorgan failure. The fistula completely healed and the stent could be removed in five patients; however, two of them were left with a small, aseptic, residual right lung cavity. The remaining eight patients are still alive with the stent in situ. CONCLUSION: The placement of Y-shaped, single-plugged, covered, self-expandable metallic airway stents seems to be a feasible and safe method for the treatment of bronchopleural fistulas involving the right main bronchus. This stent is a promising therapeutic alternative for bronchopleural fistulas involving the right main bronchus.


Assuntos
Fístula Brônquica/diagnóstico por imagem , Fístula Brônquica/cirurgia , Doenças Pleurais/diagnóstico por imagem , Doenças Pleurais/cirurgia , Radiografia Intervencionista , Stents , Tomografia Computadorizada por Raios X , Adulto , Idoso , Ligas , Angiografia Digital , Fístula Brônquica/etiologia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Pleurais/etiologia , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA