Rapid Commun Mass Spectrom ; 28(11): 1215-20, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24760562

RESUMO

RATIONALE: Stepwise preparation of calibration standards and quality controls (QCs) is one of the most routine and laborious steps in bioanalysis. An alternative non-contact dispenser using low picoliter digitized dispensing technology is evaluated for its application in non-stepwise preparation of calibration curve and QCs in bioanalysis. METHODS: Fluorescein was initially used to assess the accuracy and precision of dispense volumes with fluorescent measurement. Various concentrations of MX-1, an in-house proprietary small molecule compound, in neat solution and in dog plasma were prepared manually with calibrated pipettors and digitally by the digital dispenser. The plasma samples were extracted by protein precipitation. The resultant extracted samples and neat solutions of MX-1 were analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using an electrospray ionization (ESI) source in positive ion mode with selected reaction monitoring (SRM) of the mass transitions. RESULTS: In the three-day precision and accuracy assessment of dispensing volumes between 13 pL to 411.2 nL, the intra-day precision and accuracy ranged from 1.4% to 10.3% and -12.7% to 12.8%, respectively. The inter-day precision and accuracy ranged from 3.5% to 7.8% and -6.6% to 10.4%, respectively. For real analysis of in vivo study samples, all 49 samples analyzed showed a less than 5% difference between calibrations with digital and manual curve preparations. The resultant pharmacokinetic (PK) parameters were physiologically comparable as well. CONCLUSIONS: Using the digitized picoliter dispensing technology, high-speed automated precise and accurate dispense of a wide range of volumes can be achieved and tests for bioanalytical standards and QC preparations passed the stringent criteria set forth for regulated bioanalysis using LC/MS/MS-based technology. The digital dispenser has been found to be a useful tool in drug discovery for automatically preparing standards and QCs in seconds with low consumption of stock solutions and blank matrices.


Assuntos
Cromatografia Líquida/instrumentação , Plasma/química , Espectrometria de Massas em Tandem/instrumentação , Animais , Automação , Calibragem , Cromatografia Líquida/métodos , Cães , Controle de Qualidade , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas
3.
Clin Cancer Res ; 24(9): 2159-2170, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29463553

RESUMO

Purpose: Pediatric glioblastoma multiforme (pGBM) is a highly aggressive tumor in need of novel therapies. Our objective was to demonstrate the therapeutic efficacy of MLN8237 (alisertib), an orally available selective inhibitor of Aurora A kinase (AURKA), and to evaluate which in vitro model system (monolayer or neurosphere) can predict therapeutic efficacy in vivoExperimental Design: AURKA mRNA expressions were screened with qRT-PCR. In vitro antitumor effects were examined in three matching pairs of monolayer and neurosphere lines established from patient-derived orthotopic xenograft (PDOX) models of the untreated (IC-4687GBM), recurrent (IC-3752GBM), and terminal (IC-R0315GBM) tumors, and in vivo therapeutic efficacy through log rank analysis of survival times in two models (IC-4687GBM and IC-R0315GBM) following MLN8237 treatment (30 mg/kg/day, orally, 12 days). Drug concentrations in vivo and mechanism of action and resistance were also investigated.Results: AURKA mRNA overexpression was detected in 14 pGBM tumors, 10 PDOX models, and 6 cultured pGBM lines as compared with 11 low-grade gliomas and normal brains. MLN8237 penetrated into pGBM xenografts in mouse brains. Significant extension of survival times were achieved in IC-4687GBM of which both neurosphere and monolayer were inhibited in vitro, but not in IC-R0315GBM of which only neurosphere cells responded (similar to IC-3752GBM). Apoptosis-mediated MLN8237 induced cell death, and the presence of AURKA-negative and CD133+ cells appears to have contributed to in vivo therapy resistance.Conclusions: MLN8237 successfully targeted AURKA in a subset of pGBMs. Our data suggest that combination therapy should aim at AURKA-negative and/or CD133+ pGBM cells to prevent tumor recurrence. Clin Cancer Res; 24(9); 2159-70. ©2018 AACR.


Assuntos
Antineoplásicos/farmacologia , Aurora Quinase A/antagonistas & inibidores , Azepinas/farmacologia , Glioblastoma/metabolismo , Glioblastoma/patologia , Inibidores de Proteínas Quinases/farmacologia , Pirimidinas/farmacologia , Animais , Apoptose/efeitos dos fármacos , Aurora Quinase A/genética , Aurora Quinase A/metabolismo , Biomarcadores , Biomarcadores Tumorais , Barreira Hematoencefálica/efeitos dos fármacos , Barreira Hematoencefálica/metabolismo , Linhagem Celular Tumoral , Criança , Pré-Escolar , Modelos Animais de Doenças , Feminino , Citometria de Fluxo , Glioblastoma/tratamento farmacológico , Glioblastoma/mortalidade , Humanos , Imuno-Histoquímica , Imunofenotipagem , Masculino , Gradação de Tumores , Ensaios Antitumorais Modelo de Xenoenxerto
4.
J Chromatogr Sci ; 52(8): 950-3, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23899466

RESUMO

Column-related carryover affects both accuracy and precision in liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. In this work, a novel straightforward dynamic flush method to reduce the column-related carryover was developed by alternating the column flow direction of liquid chromatographic separation with a Valco switching valve and pristine instrument control software. By alternating the column flow direction, a fresh inlet is always in line to accommodate sample injection and stacking. In addition, the contaminated column inlet from the previous run is switched to the outlet position for a flush with a gradient during the next sample run. In this way, the column-related carryover can be reduced effectively without additional blank runs. It also minimizes the carryover risk between the adjacent unknown samples. The column-related carryover of the tested "sticky" compounds was reduced by 52.3-94.4% compared with the non-dynamic flush method under the same experimental conditions. The performance and reproducibility of high-performance liquid chromatography (HPLC) separation in terms of the retention time shift and peak shape are not compromised under the dynamic flush even after over 300 consecutive injections. The described novel method is simple and easy to implement for compounds with column-related carryover.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
5.
Mol Cancer Ther ; 11(9): 2045-53, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22609854

RESUMO

Diffuse large B-cell lymphoma (DLBCL) is the most common of the non-Hodgkin lymphomas, accounting for up to 30% of all newly diagnosed lymphoma cases. Current treatment options for this disease are effective, but not always curative; therefore, experimental therapies continue to be investigated. We have discovered an experimental, potent, and selective small-molecule inhibitor of PLK1, MLN0905, which inhibits cell proliferation in a broad range of human tumor cells including DLBCL cell lines. In our report, we explored the pharmacokinetic, pharmacodynamic, and antitumor properties of MLN0905 in DLBCL xenograft models grown in mice. These studies indicate that MLN0905 modulates the pharmacodynamic biomarker phosphorylated histone H3 (pHisH3) in tumor tissue. The antitumor activity of MLN0905 was evaluated in three human subcutaneous DLBCL xenograft models, OCI LY-10, OCI LY-19, and PHTX-22L (primary lymphoma). In each model, MLN0905 yielded significant antitumor activity on both a continuous (daily) and intermittent dosing schedule, underscoring dosing flexibility. The antitumor activity of MLN0905 was also evaluated in a disseminated xenograft (OCI LY-19) model to better mimic human DLBCL disease. In the disseminated model, MLN0905 induced a highly significant survival advantage. Finally, MLN0905 was combined with a standard-of-care agent, rituximab, in the disseminated OCI LY-19 xenograft model. Combining rituximab and MLN0905 provided both a synergistic antitumor effect and a synergistic survival advantage. Our findings indicate that PLK1 inhibition leads to pharmacodynamic pHisH3 modulation and significant antitumor activity in multiple DLBCL models. These data strongly suggest evaluating PLK1 inhibitors as DLBCL anticancer agents in the clinic.


Assuntos
Anticorpos Monoclonais Murinos/administração & dosagem , Antineoplásicos/administração & dosagem , Benzazepinas/administração & dosagem , Proteínas de Ciclo Celular/antagonistas & inibidores , Linfoma Difuso de Grandes Células B/tratamento farmacológico , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Proteínas Proto-Oncogênicas/antagonistas & inibidores , Tionas/administração & dosagem , Administração Oral , Animais , Anticorpos Monoclonais Murinos/farmacologia , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Benzazepinas/farmacocinética , Benzazepinas/farmacologia , Proteínas de Ciclo Celular/genética , Proteínas de Ciclo Celular/metabolismo , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Esquema de Medicação , Sinergismo Farmacológico , Feminino , Técnicas de Silenciamento de Genes , Histonas/metabolismo , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Proteínas Serina-Treonina Quinases/genética , Proteínas Serina-Treonina Quinases/metabolismo , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas/metabolismo , Interferência de RNA , Rituximab , Tionas/farmacocinética , Tionas/farmacologia , Carga Tumoral/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto , Quinase 1 Polo-Like
6.
J Med Chem ; 55(1): 197-208, 2012 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-22070629

RESUMO

This article describes the discovery of a series of potent inhibitors of Polo-like kinase 1 (PLK1). Optimization of this benzolactam-derived chemical series produced an orally bioavailable inhibitor of PLK1 (12c, MLN0905). In vivo pharmacokinetic-pharmacodynamic experiments demonstrated prolonged mitotic arrest after oral administration of 12c to tumor bearing nude mice. A subsequent efficacy study in nude mice achieved tumor growth inhibition or regression in a human colon tumor (HT29) xenograft model.


Assuntos
Antineoplásicos/síntese química , Benzazepinas/síntese química , Proteínas de Ciclo Celular/antagonistas & inibidores , Lactamas/síntese química , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Proteínas Proto-Oncogênicas/antagonistas & inibidores , Tionas/síntese química , Administração Oral , Animais , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Benzazepinas/farmacocinética , Benzazepinas/farmacologia , Disponibilidade Biológica , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Cristalografia por Raios X , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Lactamas/farmacocinética , Lactamas/farmacologia , Camundongos , Camundongos Nus , Mitose , Modelos Moleculares , Transplante de Neoplasias , Conformação Proteica , Ratos , Ratos Sprague-Dawley , Relação Estrutura-Atividade , Tionas/farmacocinética , Tionas/farmacologia , Transplante Heterólogo , Quinase 1 Polo-Like