Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38932596

RESUMO

PURPOSE: The purpose of this study was to assess whether kinematic alignment (KA) outperforms mechanical alignment (MA) in restoring patellar tracking to native patterns by using a clustering algorithm. METHODS: Twenty cadavers (40 knees) were evaluated. For each cadaver, one knee was randomly assigned to KA and the other to MA. KA total knee arthroplasty (TKA) procedures were performed using a caliper-verified technique, while MA TKA procedures utilized a measured resection technique. Subsequently, all specimens were mounted on a customized knee-testing system, and patellar tracking was measured using a motion analysis system. All patellar tracking data were clustered using the density-based spatial clustering of applications with noise algorithm. Differences in patellar tracking patterns and the restoration of native patellar tracking were compared between the two alignment strategies. RESULTS: Patellar tracking patterns following KA were considerably different from MA. Pre- and post-TKA patellar tracking patterns following MA were grouped into separate clusters, whereas a substantial proportion of patellar tracking patterns following KA were grouped into the pre-TKA dominant cluster. Compared to MA, a greater proportion of patellar tracking patterns following KA showed similar patterns to native knees (p < 0.05) and more patellar tracking patterns following KA paired with preoperative patterns (p < 0.01). CONCLUSION: KA restored native patellar tracking patterns more closely compared to MA. LEVEL OF EVIDENCE: Level I, therapeutic study.

2.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2815-2823, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34312712

RESUMO

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA) targets restoration of patient-specific alignment and soft tissue laxity. However, whether KA TKA reproduces native soft tissue strain remains unclear. This cadaveric study tested the hypothesis that KA TKA would better restore the quantitative strain and strain distribution of medial collateral ligament (MCL) to the native healthy knee compared to mechanically aligned (MA) TKA. METHODS: Twenty-four fresh-frozen cadaver knees (12 pairs) were mounted on a customized knee squatting simulator to measure MCL strain during flexion. For each pair, one knee was assigned to KA TKA and the other to MA TKA. During KA TKA, the amount of femur and tibia resected was equivalent to implant thickness without MCL release using the calipered measuring technique. MA TKA was performed using conventional measured resection techniques. MCL strain was measured using a video extensometer (Mercury® RT RealTime tracking system, Sobriety s.r.o, Czech Republic). MCL strain and strain distribution during knee flexion were measured, and the measurements compared between native and post-TKA conditions. RESULTS: Mean and peak MCL strain were similar between KA TKA and native knees at all flexion angles (p > 0.1 at all flexion angles) while mean strain at all flexion angles and peak strain at ≥ 60º of MA TKA were approximately twice those of the native knees (p < 0.05 at ≥ 60º of flexion). In addition, greater MCL strain was observed in 4 of 12 regions of interest (ROI) after MA TKA (M1, M2, P1 and P2) compared to the native knee, whereas after KA TKA, MCL strain measurements were similar at all but 1 ROI (P2). CONCLUSIONS: KA TKA restored a more native amount and distribution of MCL strain compared to MA TKA. These findings provide clues for understanding why patients may experience better performance and more normal knee sensations after KA TKA compared to MA TKA. LEVEL OF EVIDENCE: Therapeutic study, Level I.


Assuntos
Artroplastia do Joelho , Ligamentos Colaterais , Prótese do Joelho , Ligamento Colateral Médio do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Ligamentos Colaterais/cirurgia , Humanos , Articulação do Joelho/cirurgia , Ligamento Colateral Médio do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
3.
Medicina (Kaunas) ; 58(12)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36556953

RESUMO

Background and Objectives: Guided-motion bicruciate-stabilized (BCS) total knee arthroplasty (TKA) includes a dual cam-post mechanism with an asymmetric bearing geometry that promotes normal knee kinematics and enhances anterior-posterior stability. However, it is unclear whether the improved biomechanics after guided-motion BCS TKA reproduce soft tissue strain similar to the strain generated by native knees. The purpose of this cadaveric study was to compare medial collateral ligament (MCL) strain between native and guided-motion BCS TKA knees using a video extensometer. Materials and Methods: Eight cadaver knees were mounted onto a customized knee squatting simulator to measure MCL strain during flexion in both native and guided-motion BCS TKA knees (Journey II-BCS; Smith & Nephew, Memphis, TN, USA). MCL strain was measured using a video extensometer (Mercury® RT RealTime tracking system, Sobriety s.r.o, Kurim, Czech Republic). MCL strain level and strain distribution during knee flexion were compared between the native and guided-motion BCS TKA conditions. Results: The mean and peak MCL strain were similar between native and guided-motion BCS TKA knees at all flexion angles (p > 0.1). MCL strain distribution was similar between native and BCS TKA knees at 8 of 9 regions of interest (ROIs), while higher MCL strain was observed after BCS TKA than in the native knee at 1 ROI in the mid portion of the MCL at early flexion angles (p < 0.05 at ≤30° of flexion). Conclusions: Guided-motion BCS TKA restored the amount and distribution of MCL strain to the values observed on native knees.


Assuntos
Artroplastia do Joelho , Ligamentos Colaterais , Humanos , Rotação , Articulação do Joelho/cirurgia , Joelho , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Ligamentos Colaterais/cirurgia
4.
J Hand Surg Am ; 45(10): 985.e1-985.e9, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32434732

RESUMO

PURPOSE: Internal bracing (IB) is an augmentation method using high-strength nonabsorbable tape. This study compared scapholunate interosseous ligament (SLIL) repair alone, SLIL repair with IB augmentation (RIBA), and native intact SLIL (NIS) in a biomechanical cadaveric model. METHODS: We used 21 specimens of fresh-frozen wrists in this study (7 matched pairs, SLIL repair-only and SLIL RIBA groups; and 7 independent fresh-frozen wrists, NIS group). In the SLIL RIBA group, augmentation using IB was performed after the repair. The specimens were preloaded and cyclically loaded in tension. Maximum extension and hysteresis were measured in all specimens. The specimens were subsequently tested for load to failure. Failure load (yield point load, mean ultimate load, and load at clinical failure) and linear stiffness were calculated. RESULTS: In cyclic tensile testing, RIBA showed lower maximum extension and lower hysteresis than repair alone. In load to failure testing, the yield point load was statistically higher in the RIBA (59.3 N) group than in the repair-only (30.4 N) group but showed no significant difference compared with the NIS (90.7 N) groups. Moreover, the RIBA (98.5 N) group showed higher and lower mean ultimate loads than the repair-only (37.7 N) and NIS (211.8 N) groups, respectively. Load at clinical failure was higher with RIBA than with repair alone (3-mm extension: 70.0 vs 26.4 N; 4-mm extension: 84.1 vs 33.4 N). Repair alone and RIBA had comparable linear stiffness (38.2 vs 44.1 N/mm). CONCLUSIONS: Although SLIL RIBA did not recreate biomechanical properties equivalent to those of NIS, it demonstrated a significantly higher strength than repair alone. CLINICAL RELEVANCE: Repair with IB augmentation could serve as a novel surgical technique that enhances SLIL direct repair through biomechanical support.


Assuntos
Osso Semilunar , Osso Escafoide , Fenômenos Biomecânicos , Cadáver , Humanos , Ligamentos Articulares/cirurgia , Osso Escafoide/cirurgia , Articulação do Punho
5.
Arch Orthop Trauma Surg ; 138(7): 911-920, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29546620

RESUMO

INTRODUCTION: Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. MATERIALS AND METHODS: A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model. RESULTS: The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block. CONCLUSION: The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.


Assuntos
Placas Ósseas , Osteotomia/instrumentação , Osteotomia/métodos , Tíbia/cirurgia , Idoso , Desenho de Equipamento , Feminino , Análise de Elementos Finitos , Humanos , Articulação do Joelho/cirurgia , Masculino , Metais , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Cicatrização
6.
Lasers Med Sci ; 28(6): 1495-502, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23324954

RESUMO

This study was aimed to evaluate the effects of low-level laser therapy (LLLT) in the treatment of trabecular bone loss induced by skeletal unloading. Twelve mice have taken denervation operation. At 2 weeks after denervation, LLLT (wavelength, 660 nm; energy, 3 J) was applied to the right tibiae of 6 mice (LASER) for 5 days/week over 2 weeks by using a minimally invasive laser needle system (MILNS) which consists of a 100 µm optical fiber in a fine needle (diameter, 130 µm) [corrected]. Structural parameters and histograms of bone mineralization density distribution (BMDD) were obtained before LLLT and at 2 weeks after LLLT. In addition, osteocyte, osteoblast, and osteoclast populations were counted. Two weeks after LLLT, bone volume fraction, trabeculae number, and trabeculae thickness were significantly increased and trabecular separations, trabecular bone pattern factor, and structure model index were significantly decreased in LASER than SHAM (p < 0.05). BMDD in LASER was maintained while that in SHAM was shifted to lower mineralization. Osteocyte and osteoblast populations were significantly increased but osteoclast population was significantly decreased in LASER when compared with those in SHAM (p < 0.05). The results indicate that LLLT with the MILNS may enhance bone quality and bone homeostasis associated with enhancement of bone formation and suppression of bone resorption.


Assuntos
Reabsorção Óssea/radioterapia , Terapia com Luz de Baixa Intensidade/instrumentação , Animais , Densidade Óssea/efeitos da radiação , Reabsorção Óssea/etiologia , Reabsorção Óssea/patologia , Feminino , Elevação dos Membros Posteriores/efeitos adversos , Camundongos , Camundongos Endogâmicos ICR , Agulhas , Fibras Ópticas , Osteoblastos/patologia , Osteoblastos/efeitos da radiação , Osteoclastos/patologia , Osteoclastos/efeitos da radiação , Osteócitos/patologia , Osteócitos/efeitos da radiação
7.
Orthop Surg ; 15(9): 2477-2481, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37345451

RESUMO

BACKGROUND: Idiopathic avascular necrosis of the lunate is known as Kienböck's disease and that of the scaphoid is known as Preiser's disease. Because the prevalence of coexisting Kienböck's and Preiser's diseases is very low, standardized stages of disease and treatments are not established. CASE PRESENTATION: We report coexisting avascular necrosis of the scaphoid and lunate in a 68-year-old woman with no history of steroids or other risk factors. We treated her with proximal row carpectomy with capsular interposition technique. A distal-based dorsal capsular flap was prepared and repaired the palmar capsule. At the last follow-up, she had no pain and had gained improved range of wrist motion. There was no arthritic change at the newly formed radiocapitate joint. CONCLUSIONS: In the case of collapsed lunate and scaphoid with avascular necrosis, the proximal row carpectomy procedure has an advantage. Proximal row carpectomy with dorsal capsular interposition can be performed when the lunate or scaphoid cannot be saved. Arthritic changes of the capitate head and distal radius lunate facet can be covered with the dorsal capsule.


Assuntos
Ossos do Carpo , Osso Semilunar , Osteonecrose , Humanos , Feminino , Idoso , Ossos do Carpo/cirurgia , Punho , Articulação do Punho/cirurgia , Osso Semilunar/cirurgia , Osteonecrose/cirurgia
8.
Bioengineering (Basel) ; 10(11)2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-38002435

RESUMO

There are many techniques for the treatment of chronic scapholunate dissociation. The three-ligament tenodesis (3LT) is used most widely, but reconstruction of the dorsal ligament alone may not provide sufficient stability. The Mark-Henry technique (MHT) compensates for the insufficient stability of 3LT by additional reconstruction of the volar ligament, but the procedure is complex. The SwiveLock technique (SWT), a recently introduced method, provides stability by using autologous tendons with synthetic tapes, but lacks long-term clinical results. To perform biomechanical comparisons of different reconstructive techniques for scapholunate dissociation using a controlled laboratory cadaveric model. Eleven fresh-frozen upper-extremity cadaveric specimens were prepared. The scapholunate distance, scaphoid rotation, and lunate rotation of the specimens were measured during continuous flexion-extension and ulnar-radial deviation movements. The data were collected using a wrist simulator with a linear guide rail system (tendon load/motion-controlled system) and a motion capture system. Results were compared in five conditions: (1) intact, (2) scapholunate dissociation, (3) SWT, (4) 3LT, and (5) MHT. Paired t-test was employed to compare the biomechanical characteristics of intact wrists to those of scapholunate dissociated wrists, and to those of wrists after each of the three reconstruction methods. SWT and MHT were effective solutions for reducing the widening in scapholunate distance. According to the radioscaphoid angle, all three reconstruction techniques were effective in addressing the flexion deformity of the scaphoid. According to the radiolunate angle, only SWT was effective in addressing the extension deformity of the lunate. In terms of scapholunate angle, only the results after SWT did not differ from those of the intact wrist. The SWT technique most effectively improved distraction intensity and rotational strength for the treatment of scapholunate dissociation. Taking into account the technical complexity of 3LT and MHT, SWT may be a more efficient technique to reduce operating time and minimize complications due to multiple incisions, transosseous tunnels, and complicated shuttling.

9.
Orthop Surg ; 15(7): 1920-1925, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37254251

RESUMO

BACKGROUND: Treatments for chronic perilunate or lunate dislocations are very difficult and associated with poor prognoses. There is no established treatment method and are still many controversies. CASE PRESENTATION: We reported three cases of chronic neglected lunate volar dislocation treated with a novel surgical technique. All three cases were males with wrist pain and tingling sensation. Radiographs confirmed chronic volar dislocation of the lunate. Open reduction was performed by combined volar and dorsal approaches. After anatomical reduction, scapholunate and lunotriquetral interosseous ligament reconstructions were performed with the palmaris longus tendon and synthetic tape. The patients had an uneventful postoperative period with satisfactory functional outcomes at the last follow-up. CONCLUSIONS: We believe that open reduction and interosseous ligament reconstruction using the autogenous tendon and synthetic tape may be a valuable option for treating chronic volar dislocation of the lunate.


Assuntos
Luxações Articulares , Osso Semilunar , Osso Escafoide , Traumatismos do Punho , Masculino , Humanos , Feminino , Osso Escafoide/cirurgia , Ligamentos Articulares/cirurgia , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Extremidade Superior , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/cirurgia
10.
Sci Rep ; 13(1): 8601, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237009

RESUMO

This study aimed to investigate the efficacy of a closed-cell self-expandable metallic stent (SEMS) with or without expanded-polytetrafluoroethylene (e-PTFE)-covering membrane in a porcine iliac artery model. Twelve Yorkshire domestic pigs were divided into a bare closed-cell SEMS (B-SEMS) group (n = 6) and covered closed-cell SEMS (C-SEMS) group (n = 6). Both closed-cell SEMSs were placed in the right or left iliac artery. Thrombogenicity score in the C-SEMS group was significantly higher than that in the B-SEMS group (p = 0.004) after 4 weeks. Angiographic findings of mean luminal diameters at 4 weeks follow-up did not differ significantly between B-SEMS and C-SEMS groups. Neointimal hyperplasia thickness as well as degree of inflammatory cell infiltration and collagen deposition in the C-SEMS group was significantly greater than that in the B-SEMS group (p < 0.001). Closed-cell SEMSs successfully maintained patency for 4 weeks without stent-related complications in the porcine iliac artery. Although mild thrombus with neointimal hyperplasia was observed in the C-SEMS group, subsequent occlusion, and in-stent stenosis did not occur in any of the pigs until the end of the study. Closed-cell SEMS with or without the e-PTFE covering membrane is effective and safe for the porcine iliac artery.


Assuntos
Doença Arterial Periférica , Stents Metálicos Autoexpansíveis , Suínos , Animais , Artéria Ilíaca/cirurgia , Hiperplasia , Stents , Politetrafluoretileno , Resultado do Tratamento , Estudos Retrospectivos
11.
Sci Rep ; 12(1): 5727, 2022 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-35388130

RESUMO

The proactive safety seat (PSS) is a recently developed active safety system for securing occupant safety in out-of-seat position (OOSP), which was applied in the Hyundai Genesis G80 in 2020. However, there has not been sufficient quantifiable verification supporting the effectiveness of the PSS. The present study was performed to determine the effectiveness of the PSS for occupant safety in OOSP and to identify areas for additional improvement. Six test conditions were considered to determine the effectiveness of the PSS for augmentation of occupant safety in OOSP. Ten healthy men participated in the tests. Compared with the no PSS condition, maximum head excursion and neck rotation were significantly decreased in the PSS condition by 0.6-0.8-fold and 0.6-0.7-fold, respectively (P < 0.05). The PSS condition in which the seat pan was moved forward to the mid position showed a greater effect in reducing the characteristic motions related to submarining, compared with the condition in which the seat pan was moved rearward to the mid position (P < 0.05). These results suggested that PSS augments occupant safety in OOSP. This study provides valuable insights in ameliorating risks to the occupant in unintended seat positions before braking and/or collision.


Assuntos
Acidentes de Trânsito , Acidentes de Trânsito/prevenção & controle , Fenômenos Biomecânicos , Humanos , Masculino
12.
Medicine (Baltimore) ; 101(24): e29479, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35713459

RESUMO

RATIONALE: Pan-carpal dissociation is very rare injury and there is little information as to diagnosis, treatment, and prognosis of this injury. PATIENT CONCERNS: A 35-year-man presented to our hospital with severe pain and swelling of the left wrist and forearm after slipping and falling while riding a motorcycle. DIAGNOSIS: The wrist simple radiographs demonstrated unrecognizable severe fracture-dislocation of the carpal bones concomitant with fractures of the radioulnar shaft. Three-dimensional computed tomography revealed a capitate fracture-dislocation, as well as hamate dislocation, lunotriquetral (LT), and scapholunate (SL) dissociation. These findings suggested pan-carpal dissociation. INTERVENTIONS: To prevent compartment syndrome, fasciotomy, carpal tunnel release, and open reduction and plate fixation for both bone fracture were performed first. Then, for pan-carpal dissociation, the capitate, carpometacarpal joint (CMCJ), and hamate were reduced and fixed first. Then, the SL, LT, and other intercarpal ligaments were repaired. Finally, additional trans-carpal pins to reinforce the ligament repair and 2.0 mm plate to buttress the third CMCJ were fixed. The patient was instructed to begin gentle range of motion exercises of the wrist with pins from four weeks after surgery and all pins were removed at six weeks postoperatively. OUTCOMES: 12 months after the operation, the patient exhibited almost full range of motion with mild pain with VAS (Visual analogue scale) 1-2 at rest and VAS 3-4 with effort. Quick DASH (the disabilities of the arm, shoulder and hand) score was 25 and modified Mayo score was 70. The radiographs demonstrated union of the radioulnar shaft, and the carpal bone alignment was successfully maintained. LESSONS: Pan-carpal dissociation can be diagnosed in patients with capitate fracture-dislocation, hamate dislocation, LT, and SL dissociation. This pattern of injury is very rare and the authors recommend reduction and fixation of the distal carpal row, followed by the proximal row to facilitate an easy approach to the distal carpal row. Although it is very severe injury, rigid anatomical fixation and an early rehabilitation can lead to favorable functional outcomes.


Assuntos
Ossos do Carpo , Fratura-Luxação , Luxações Articulares , Instabilidade Articular , Fraturas do Rádio , Placas Ósseas/efeitos adversos , Ossos do Carpo/cirurgia , Fratura-Luxação/complicações , Fixação Interna de Fraturas/métodos , Humanos , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Dor/complicações , Fraturas do Rádio/cirurgia , Articulação do Punho/cirurgia
13.
Biomolecules ; 13(1)2022 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-36671440

RESUMO

Three-dimensional (3D) bioprinted skin equivalents are highlighted as the new gold standard for alternative models to animal testing, as well as full-thickness wound healing. In this review, we focus on the advances and innovations of 3D bioprinting skin for skin regeneration, within the last five years. After a brief introduction to skin anatomy, 3D bioprinting methods and the remarkable features of recent studies are classified as advances in materials, structures, and functions. We will discuss several ways to improve the clinical potential of 3D bioprinted skin, with state-of-the-art printing technology and novel biomaterials. After the breakthrough in the bottleneck of the current studies, highly developed skin can be fabricated, comprising stratified epidermis, dermis, and hypodermis with blood vessels, nerves, muscles, and skin appendages. We hope that this review will be priming water for future research and clinical applications, that will guide us to break new ground for the next generation of skin regeneration.


Assuntos
Bioimpressão , Engenharia Tecidual , Animais , Bioimpressão/métodos , Impressão Tridimensional , Pele , Epiderme
14.
Bioengineering (Basel) ; 9(10)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36290532

RESUMO

Background: Recent evidence supports that restoration of the pre-arthritic condition via total knee arthroplasty (TKA) is associated with improved post-TKA performance and patient satisfaction. However, whether the restored pre-arthritic joint line simulates the native mid-flexion biomechanics remains unclear. Objective: We performed a matched-pair cadaveric study to explore whether restoration of the joint line via kinematically aligned (KA) TKA reproduced native knee biomechanics more accurately than the altered joint line associated with mechanically aligned (MA) TKA. Methods: Sixteen fresh-frozen cadaveric knees (eight pairs) were affixed onto a customized knee-squatting simulator for measurement of femoral rollback and medial collateral ligament (MCL) strain during mid-flexion. One knee from each cadaver was randomly designated to the KA TKA group (with the joint line restored to the pre-arthritic condition) and the other to the MA TKA group (with the joint line perpendicular to the mechanical axis). Optical markers were attached to all knees and rollback was analyzed using motion capture cameras. A video extensometer measured real-time variations in MCL strain. The kinematics and MCL strain prior to and following TKA were measured for all specimens. Results: KA TKA was better for restoring the knee kinematics to the native condition than MA TKA. The mid-flexion femoral rollback and axial rotation after KA TKA were consistently comparable to those of the native knee. Meanwhile, those of MA TKA were similar only at ≤40° of flexion. Furthermore, KA TKA better restored the mid-flexion MCL strain to that of the native knee than MA TKA. Over the entire mid-flexion range, the MCL strain of KA TKA and native knees were similar, while the strains of MA TKA knees were more than twice those of native knees at >20° of flexion. Conclusions: The restored joint line after KA TKA effectively reproduced the native mid-flexion rollback and MCL strain, whereas the altered joint line after MA TKA did not. Our findings may explain why patients who undergo KA TKA experience superior outcomes and more natural knee sensations during daily activities than those treated via MA TKA.

15.
Sci Rep ; 12(1): 16524, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36192510

RESUMO

Stent-grafts composed of expanded polytetrafluoroethylene (e-PTFE), polyethylene terephthalate (PET) and polyurethane (PU) are characterized by poor endothelialization, high modulus, and low compliance, leading to thrombosis and intimal hyperplasia. A composite synthetic/natural matrix is considered a promising alternative to conventional synthetic stent-grafts. This study aimed to investigate the efficacy of thermoplastic polyurethane (TPU) and gelatin (GL) blended nanofibers (NFs) covered stent-graft in the porcine iliac artery. Twelve pigs were randomly sacrificed 7 days (n = 6) and 28 days (n = 6) after stent-graft placement. The thrombogenicity score at 28 days was significantly increased compared at 7 days (p < 0.001). The thickness of neointimal hyperplasia, degree of inflammatory cell infiltration, and degree of collagen deposition were significantly higher at 28 days than at 7 days (all p < 0.001). The TPU and GL blended NFs-covered stent-grafts successfully maintained the patency for 28 days in the porcine iliac artery. Although thrombosis with neointimal tissue were observed, no subsequent occlusion of the stent-graft was noted until the end of the study. Composite synthetic/natural matrix-covered stent-grafts may be promising for prolonging stent-graft patency.


Assuntos
Artéria Ilíaca , Nanofibras , Animais , Prótese Vascular , Gelatina , Hiperplasia/patologia , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Neointima/patologia , Polietilenotereftalatos , Politetrafluoretileno , Poliuretanos , Stents , Suínos
16.
J Arthroplasty ; 26(4): 596-605, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20817389

RESUMO

We prospectively evaluated acetabular cup placement in total hip arthroplasty with an imageless computer navigation system or using conventional manual technique. The achieved cup orientation in the manual group had substantially larger variances and greater placement error than the navigation cases. The use of navigation was abandoned in 3 cases because of excessive pelvic tilt and unreliable registration of the pelvis. Computer navigation system helped improve the accuracy of the acetabular cup placement for total hip arthroplasty in this study. The variation between the intraoperative navigation readings and the computed tomographic values suggests that relying on palpation of bony landmarks through drapes and tissue is a limitation of this method. Further, the variation in pelvic tilt has an effect on cup placement that requires further studies.


Assuntos
Artroplastia de Quadril/métodos , Imageamento Tridimensional/métodos , Osteoartrite do Quadril/cirurgia , Cirurgia Assistida por Computador/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Artroplastia de Quadril/efeitos adversos , Mau Alinhamento Ósseo/epidemiologia , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Fluoroscopia , Luxação do Quadril/epidemiologia , Luxação do Quadril/prevenção & controle , Humanos , Imageamento Tridimensional/efeitos adversos , Incidência , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Cirurgia Assistida por Computador/efeitos adversos , Tomografia Computadorizada por Raios X
17.
Ann Biomed Eng ; 49(9): 2468-2480, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34114130

RESUMO

The occupant's posture can be changeable to an inadvertent or unintentional out-of-seat position (OOSP) depend on their convenience. Understanding for OOSP has been demanded, but it is not sufficient; especially when AEB is activated. The aim of the current study was to characterize the motion responses of an occupant in various OOSPs when AEB is activated and to identify if there were any additional risks of injury or discomfort to the occupant. The normal seat position (NSP) and three OOSPs were defined to compare the difference of human responses, and six healthy males were participated. Particularly, the maximum rotation angles of the neck in OOSP2 and OOSP3 differed significantly around 1.3 ± 0.3 and 1.4 ± 0.2 times higher respectively than from in the NSP (p < 0.05). Occupants assuming OOSP3 exhibited motion characteristics were not restrained effectively and characterized a hovering and falling upper body and a slipping pelvis. This study has identified, for the first time, a potential risk of injury or discomfort when AEB is activated while an occupant is in an OOSP. This study may serve as fundamental data for the development of safety system that can improve restraint and counteract any deterioration in occupant safety.


Assuntos
Acidentes de Trânsito , Condução de Veículo , Movimento/fisiologia , Adulto , Fenômenos Biomecânicos , Eletromiografia , Humanos , Masculino , Músculo Esquelético/fisiologia , Postura Sentada , Adulto Jovem
18.
Sci Rep ; 11(1): 22317, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34785741

RESUMO

Direct energy deposition (DED) is a newly developed 3D metal printing technique that can be utilized on a porous surface coating of joint implants, however there is still a lack of studies on what advantages DED has over conventional techniques. We conducted a systematic mechanical and biological comparative study of porous coatings prepared using the DED method and other commercially available technologies including titanium plasma spray (TPS), and powder bed fusion (PBF). DED showed higher porosity surface (48.54%) than TPS (21.4%) and PBF (35.91%) with comparable fatigue cycle. At initial cell adhesion, cells on DED and PBF surface appeared to spread well with distinct actin stress fibers through immunofluorescence study. It means that the osteoblasts bind more strongly to the DED and PBF surface. Also, DED surface showed higher cell proliferation (1.27 times higher than TPS and PBF) and osteoblast cell activity (1.28 times higher than PBF) for 2 weeks culture in vitro test. In addition, DED surface showed better bone to implant contact and new bone formation than TPS in in vivo study. DED surface also showed consistently good osseointegration performance throughout the early and late period of osseointegration. Collectively, these results show that the DED coating method is an innovative technology that can be utilized to make cementless joint implants.


Assuntos
Materiais Revestidos Biocompatíveis/química , Implantes Experimentais , Osseointegração , Osteoblastos/metabolismo , Titânio/química , Linhagem Celular Tumoral , Humanos , Porosidade , Propriedades de Superfície
19.
Biomater Res ; 25(1): 29, 2021 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-34563260

RESUMO

Bone is a complex structure with unique cellular and molecular process in its formation. Bone tissue regeneration is a well-organized and routine process at the cellular and molecular level in humans through the activation of biochemical pathways and protein expression. Though many forms of biomaterials have been applied for bone tissue regeneration, electrospun nanofibrous scaffolds have attracted more attention among researchers with their physicochemical properties such as tensile strength, porosity, and biocompatibility. When drugs, antibiotics, or functional nanoparticles are taken as additives to the nanofiber, its efficacy towards the application gets increased. Polyphenol is a versatile green/phytochemical small molecule playing a vital role in several biomedical applications, including bone tissue regeneration. When polyphenols are incorporated as additives to the nanofibrous scaffold, their combined properties enhance cell attachment, proliferation, and differentiation in bone tissue defect. The present review describes bone biology encompassing the composition and function of bone tissue cells and exemplifies the series of biological processes associated with bone tissue regeneration. We have highlighted the molecular mechanism of bioactive polyphenols involved in bone tissue regeneration and specified the advantage of electrospun nanofiber as a wound healing scaffold. As the polyphenols contribute to wound healing with their antioxidant and antimicrobial properties, we have compiled a list of polyphenols studied, thus far, for bone tissue regeneration along with their in vitro and in vivo experimental biological results and salient observations. Finally, we have elaborated on the importance of polyphenol-loaded electrospun nanofiber in bone tissue regeneration and discussed the possible challenges and future directions in this field.

20.
J Clin Med ; 10(7)2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918435

RESUMO

Internal bracing (IB) is an augmentation method using high-strength nonabsorbable tape. However, there is no detailed information about the direction, location, or number of IBs required for scapholunate interosseous ligament (SLIL) injury repair. Thus, this study compared the biomechanical characteristics of short-transverse IB, long-oblique IB, and the combination of short-transverse and long-oblique (Combo) IB for SLIL injury in a biomechanical cadaveric model. We prepared nine fresh-frozen full upper extremity cadaveric specimens for this study. The scapholunate distance, scapholunate angle, and radioscaphoid angle were measured using the MicroScribe digitizing system with the SLIL intact, after scapholunate dissociation and the three different reconstructions. Three-dimensional digital records were obtained in six wrist positions in each experimental condition. Short-transverse IB had a similar effect compared with long-oblique IB in addressing the widening of the scapholunate distance. However, both were less effective than Combo IB. For scaphoid flexion deformity, short-transverse IB had minimal effect, while long-oblique IB had a similar effect compared to Combo IB. Combo IB was the most effective for improving distraction intensity and rotational strength. This study provides important information about the biomechanical characteristics of three different IB methods for SLIL injury and may be useful to clinicians in treating scapholunate dissociation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA