Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ophthalmology ; 128(9): 1300-1311, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33713785

RESUMO

PURPOSE: MYOC (myocilin) mutations account for 3% to 5% of primary open-angle glaucoma (POAG) cases. We aimed to understand the true population-wide penetrance and characteristics of glaucoma among individuals with the most common MYOC variant (p.Gln368Ter) and the impact of a POAG polygenic risk score (PRS) in this population. DESIGN: Cross-sectional population-based study. PARTICIPANTS: Individuals with the p.Gln368Ter variant among 77 959 UK Biobank participants with fundus photographs (FPs). METHODS: A genome-wide POAG PRS was computed, and 2 masked graders reviewed FPs for disc-defined glaucoma (DDG). MAIN OUTCOME MEASURES: Penetrance of glaucoma. RESULTS: Two hundred individuals carried the p.Gln368Ter heterozygous genotype, and 177 had gradable FPs. One hundred thirty-two showed no evidence of glaucoma, 45 (25.4%) had probable/definite glaucoma in at least 1 eye, and 19 (10.7%) had bilateral glaucoma. No differences were found in age, race/ethnicity, or gender among groups (P > 0.05). Of those with DDG, 31% self-reported or had International Classification of Diseases codes for glaucoma, whereas 69% were undiagnosed. Those with DDG had higher medication-adjusted cornea-corrected intraocular pressure (IOPcc) (P < 0.001) vs. those without glaucoma. This difference in IOPcc was larger in those with DDG with a prior glaucoma diagnosis versus those not diagnosed (P < 0.001). Most p.Gln368Ter carriers showed IOP in the normal range (≤21 mmHg), although this proportion was lower in those with DDG (P < 0.02) and those with prior glaucoma diagnosis (P < 0.03). Prevalence of DDG increased with each decile of POAG PRS. Individuals with DDG demonstrated significantly higher PRS compared with those without glaucoma (0.37 ± 0.97 vs. 0.01 ± 0.90; P = 0.03). Of those with DDG, individuals with a prior diagnosis of glaucoma had higher PRS compared with undiagnosed individuals (1.31 ± 0.64 vs. 0.00 ± 0.81; P < 0.001) and 27.5 times (95% confidence interval, 2.5-306.6) adjusted odds of being in the top decile of PRS for POAG. CONCLUSIONS: One in 4 individuals with the MYOC p.Gln368Ter mutation demonstrated evidence of glaucoma, a substantially higher penetrance than previously estimated, with 69% of cases undetected. A large portion of p.Gln368Ter carriers, including those with DDG, have IOP in the normal range, despite similar age. Polygenic risk score increases disease penetrance and severity, supporting the usefulness of PRS in risk stratification among MYOC p.Gln368Ter carriers.


Assuntos
Proteínas do Citoesqueleto/genética , Proteínas do Olho/genética , Glaucoma de Ângulo Aberto/genética , Glicoproteínas/genética , Herança Multifatorial/genética , Mutação , Adulto , Idoso , Bancos de Espécimes Biológicos , Estudos Transversais , Feminino , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Penetrância , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Reino Unido
2.
Exp Cell Res ; 340(1): 43-52, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26460176

RESUMO

Hedgehog (Hh) pathway activation in R26-SmoM2;CAGGS-CreER mice, which carry a tamoxifen-inducible activated Smoothened allele (SmoM2), results in numerous microscopic tumor foci in mouse skeletal muscle. These tumors exhibit a highly differentiated myogenic phenotype and resemble human fetal rhabdomyomas. This study sought to apply previously established strategies to isolate lineally distinct populations of normal mouse myofiber-associated cells in order to examine cellular heterogeneity in SmoM2 tumors. We demonstrate that established SmoM2 tumors are composed of cells expressing myogenic, adipocytic and hematopoietic lineage markers and differentiation capacity. SmoM2 tumors thus recapitulate the phenotypic and functional hetereogeneity observed in normal mouse skeletal muscle. SmoM2 tumors also contain an expanded population of PAX7+ and MyoD+ satellite-like cells with extremely low clonogenic activity. Selective activation of Hh signaling in freshly isolated muscle satellite cells enhanced terminal myogenic differentiation without stimulating proliferation. Our findings support the conclusion that SmoM2 tumors represent an aberrant skeletal muscle state and demonstrate that, similar to normal muscle, myogenic tumors contain functionally distinct cell subsets, including cells lacking myogenic differentiation potential.


Assuntos
Proteínas Hedgehog/metabolismo , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Neoplasias de Tecido Muscular/metabolismo , Neoplasias de Tecido Muscular/patologia , Alelos , Animais , Diferenciação Celular , Proliferação de Células , Citometria de Fluxo , Camundongos , Camundongos Endogâmicos C57BL , Fenótipo
4.
J Glaucoma ; 32(11): 948-953, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37671465

RESUMO

PRCIS: Participant surveys taken after using tablet-based and smart visual function analyzer (SVFA) perimetry tests suggest that patients may prefer novel perimetry tests over traditional visual field machines. PURPOSE: Compare patient experience using the IMOvifa SVFA and the tablet-based Melbourne Rapid Fields visual field (VF) tests to the Humphrey Field 24-2 Swedish Interactive Threshold Algorithm Standard. PATIENTS AND METHODS: Prospective observational cohort study on adult participants with diagnoses of glaucoma suspect, ocular hypertension, or glaucoma. Participants attended 2 study visits ~3 months apart. During the first visit, participants were trained to use the 2 novel perimeters, took 1 test on both new devices and the Humphrey Field Analyzer, then were surveyed. Participants received tablets and performed weekly tablet VF tests at home between study visits. At the final study visit, participants re-took the VF tests and completed the same surveys. RESULTS: Eighty-one participants were surveyed twice. At the baseline survey, participants preferred the SVFA (71.7%) and tablet tests (69.2%) over the Humphrey VF. Most were willing to perform weekly monitoring at home on the SVFA (69.1%) and tablet (75.4%). Participants generally had a "very good" overall experience when testing on the SVFA (71.6%) and tablet (90.1%). At the final visit, fewer participants were willing to test on the tablet daily (23.5% to 9.9%; P = 0.02 for change) and more were willing to test monthly (18.5% to 33.3%; P = 0.03 for change). CONCLUSION: Users reported a preference for novel VF devices. Overall participant experience using these devices was positive, supporting the feasibility of home monitoring of VFs from an experience perspective.


Assuntos
Glaucoma , Hipertensão Ocular , Adulto , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Estudos Prospectivos , Pressão Intraocular , Glaucoma/diagnóstico , Hipertensão Ocular/diagnóstico , Transtornos da Visão/diagnóstico
5.
J Glaucoma ; 32(6): 474-479, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36847694

RESUMO

PRCIS: This retrospective case series of patients with open angle glaucoma and prior trabeculectomy or tube shunt surgery found that selective laser trabeculoplasty (SLT) resulted in significant intraocular pressure (IOP) reductions in the intermediate follow-up period in select cases. PURPOSE: The purpose of this study was to assess the IOP-lowering effect and tolerability of SLT after prior trabeculectomy or tube shunt surgery. MATERIALS AND METHODS: Open angle glaucoma patients at Wills Eye Hospital who previously underwent incisional glaucoma surgery and subsequently received SLT between 2013 and 2018 were included, along with an age-matched control group. Baseline characteristics, procedural data, and post-SLT data were recorded at 1, 3, 6, 12 months, and most recent visit. The primary success of SLT treatment was defined as IOP reduction of 20% or greater without the use of additional glaucoma medications compared to pre-SLT IOP. Secondary success was defined as IOP reduction ≥20% with the use of additional glaucoma medications compared to pre-SLT IOP. RESULTS: There were 45 eyes in the study group and 45 eyes in the control group. In the study group, IOP decreased from a baseline of 19.5±4.7 mm Hg on 2.2±1.2 medications to 16.7±5.2 mm Hg ( P =0.002) on 2.2±1.1 glaucoma medications ( P =0.57). In the control group, IOP decreased from 19.5±4.2 mm Hg on 2.4±1.0 medications to 16.4±5.2 mm Hg ( P =0.003) on 2.1±1.3 medications ( P =0.36). There was no difference in IOP reduction or change in number of glaucoma medications after SLT at any postoperative visit between the 2 groups ( P ≥0.12 for all). Primary success rates at 12 months were 24.4% for the control group and 26.7% for the prior incisional glaucoma surgery group with no significant difference between the groups ( P =0.92). There were no persistent complications after SLT treatment in either group. CONCLUSION: SLT may effectively lower IOP in patients with open angle glaucoma who have had previous incisional glaucoma surgery and should be considered in select cases.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Hipotensão Ocular , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular , Estudos Retrospectivos , Glaucoma/cirurgia , Malha Trabecular/cirurgia , Terapia a Laser/métodos , Hipotensão Ocular/cirurgia , Lasers , Resultado do Tratamento
6.
Clin Orthop Relat Res ; 470(5): 1452-60, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22057818

RESUMO

BACKGROUND: Many hospitals require all operative specimens be sent to pathologists for routine examination. Although previous studies indicate this practice increases medical cost, it remains unclear whether it alters patient management and whether it is cost-effective. QUESTIONS/PURPOSES: We therefore (1) determined the rate of discordance between clinical and histologic examinations of routine operative specimens during elective primary arthroplasties, (2) determined the cost of routine histologic screening, and (3) estimated its cost-effectiveness in terms of cost per quality-adjusted life year gained, as compared with gross examination or no examination. METHODS: We retrospectively reviewed medical records of 1247 patients who underwent 1363 routine elective primary total joint arthroplasties between January 18, 2006 and March 15, 2010. We compared preoperative, postoperative, and histologic diagnoses for each patient and categorized them into three classes: concordant (clinical and histologic diagnoses agreed), discrepant (diagnoses differed but with no resultant change in treatment), and discordant (diagnoses differed with resultant change in treatment). Medicare reimbursements were determined through the pathology department's administrative office. RESULTS: In 1363 cases, 1335 (97.9%) clinical and histologic diagnoses were concordant, 28 (2.1%) were discrepant, and none were discordant. Total reimbursement for routine pathological examination was $139,532, or $102.37 per specimen. The average cost to identify each discrepant case was $4983.29. Routine histologic examination did not alter patient management, and there was no direct gain in quality-adjusted life years. CONCLUSIONS: Our observations show routine histologic examinations of routine operative specimens during elective primary arthroplasties increase medical cost but rarely alter patient management and are not cost-effective. LEVEL OF EVIDENCE: Level I, economic and decision analyses. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Substituição/economia , Testes Diagnósticos de Rotina/economia , Técnicas Histológicas/economia , Articulações/patologia , Análise Custo-Benefício , Humanos , Reembolso de Seguro de Saúde , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Semin Ophthalmol ; 37(3): 385-390, 2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-34586961

RESUMO

BACKGROUND: Sustained release drug delivery has the potential to change glaucoma care by decreasing the challenge of medication adherence. Many approaches are in development, but this review focuses on Durysta (Allergan plc, Dublin, Ireland), the only FDA-approved sustained release intracameral treatment available at this time. KEY FINDINGS: Durysta is a bimatoprost sustained release (BimSR) intracameral implant. Clinical trials have demonstrated that BimSR implants can provide comparable levels of intraocular pressure (IOP) control as topical eyedrops. BimSR has advantages such as decreasing concerns regarding drop adherence, reducing ocular surface and periocular side effects from topical drops, and decreased daily treatment burden for patients. In addition, studies have shown continued IOP lowering in some eyes during extended follow-up periods when all of the BimSR medication has already been delivered. Hypothesized mechanisms to explain this finding include increased matrix metalloproteinase expression that causes extracellular matrix reorganization to permit greater aqueous outflow, as well as decreased episcleral venous pressure. The major safety concern at this time for Durysta and future intracameral implants is corneal endothelial cell loss, which was worse with repeat BimSR administration compared to single dosing. Several studies are underway to investigate mechanisms of action and to better understand safe and effective dosing of medications in this class.


Assuntos
Anti-Hipertensivos , Hipertensão Ocular , Anti-Hipertensivos/uso terapêutico , Bimatoprost/farmacologia , Bimatoprost/uso terapêutico , Preparações de Ação Retardada/uso terapêutico , Humanos , Injeções Intraoculares , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico
8.
Am J Ophthalmol Case Rep ; 25: 101287, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35146185

RESUMO

PURPOSE: To describe 8 cases of reversible reticular corneal epithelial edema of the cornea that developed after use of the topical Rho-kinase inhibitor netarsudil. METHODS: This is a retrospective chart review case series of 8 patients treated with netarsudil at an academic medical center. OBSERVATIONS: Patients had predisposing corneal conditions including penetrating keratoplasty, corneal decompensation after trabeculectomy-associated endophthalmitis, congenital glaucoma with Haab striae, aphakic bullous keratopathy, history of Ahmed valve and silicone oil, and Fuchs endothelial corneal dystrophy undergoing Descemet stripping only. One patient did not have clear predisposing corneal disease other than low endothelial cell density and a history of trabeculectomy. All patients developed reticular corneal epithelial edema, which appeared as collections of moderate sized superficial epithelial bullae arranged in a reticular pattern resembling a honeycomb. Most developed these changes within weeks of initiating netarsudil, but unique to this series are 2 cases in which netarsudil was tolerated by the cornea for months before developing reticular corneal epithelial edema after diode laser cyclophotocoagulation. In cases which underwent anterior segment optical coherence tomography, the imaging demonstrated that the corneal stroma was not edematous, and the reticular corneal epithelial edema involved both host and donor corneal epithelium in cases of penetrating keratoplasty. This fully resolved in all cases upon cessation of netarsudil, and this series is the first to document resolution via a pattern in which the individual bullae become smaller and more widely spaced apart. CONCLUSION: Netarsudil can cause a reversible reticular corneal epithelial edema.

9.
Surv Ophthalmol ; 65(5): 530-547, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32057763

RESUMO

Ocular trauma is a significant cause of blindness worldwide, particularly if associated with glaucoma. Direct damage from blunt or penetrating trauma, bleeding, inflammation, lens-related problems, orbital and brain vascular pathologies related to trauma, and chemical injuries may increase intraocular pressure and lead to traumatic glaucoma. Treatment may be as simple as eliminating the underlying cause in some conditions or management can be challenging, depending on the mechanism of damage. If proper management is not undertaken, visual outcomes can be poor. We discuss a broad spectrum of trauma-related mechanisms of intraocular pressure elevation, as well as their management.


Assuntos
Gerenciamento Clínico , Glaucoma/etiologia , Pressão Intraocular/fisiologia , Hipertensão Ocular/etiologia , Ferimentos e Lesões/complicações , Glaucoma/fisiopatologia , Glaucoma/terapia , Humanos , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/terapia
10.
J Ophthalmic Vis Res ; 15(3): 412-418, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32864072

RESUMO

PURPOSE: Orbital cellulitis (OC) is a rare postoperative complication of glaucoma drainage device (GDD) implantation. To date, there have only been 10 reported cases of OC following GDD implantation. CASE REPORT: Here, we report a case of OC in a 57-year-old man who developed pain, proptosis, and limited extraocular motility two days after uneventful Ahmed FP7 implantation in the right eye. Contrast-enhanced computed tomography of the orbits demonstrated fat stranding and a small fluid collection, consistent with OC. He had minimal improvement with intravenous antibiotics and ultimately underwent GDD explantation. A systematic review of the literature showed that the development of OC following GDD implantation can occur in the early or late postoperative period. Immediate hospitalization with intravenous administration of broad-spectrum antibiotics is recommended. Explantation of the infected GDD is often required for source control. CONCLUSION: OC is a rare postoperative complication of GDD implantation. Prompt evaluation and treatment are required, often combined with GDD explantation.

11.
Transl Vis Sci Technol ; 9(8): 45, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32855891

RESUMO

Purpose: To assess grading reproducibility of disorganization of the retinal inner layers (DRIL) and other morphologic features of diabetic macular edema (DME) across spectral domain optical coherence tomography (SDOCT) instruments and scan types. Methods: A cross-sectional study enrolled participants with current or recent center-involved DME. In group A (27 eyes), we obtained two Cirrus scans (512 × 128 macular cube [Cube] and high-definition five-line raster [HD 5-Line]) and two Spectralis scans (high-resolution [HR] and high-speed [HS]). In group B, 26 eyes underwent HR scans and Optovue AngioVue (OP) 3 × 3-mm scans. All scans were graded for type and extent of DRIL, intraretinal cysts, cone outer segment tip visibility, and subretinal fluid (SRF). Results: In the total cohort, mean central subfield thickness was 342.9 ± 83.4 µm. Intraclass correlations were high for DRIL extent across the four different imaging settings (HR vs. HS, r = 0.93; HR vs. Cube, r = 0.84, HR vs. HD 5-Line, r = 0.76, HR vs. OP, r = 0.87) and ranged from good to excellent for intraretinal cyst and SRF area. There were significantly smaller mean normalized differences between HR/HS scans versus HR and all other scan modalities (HR/HS vs. HR/Cube, P = 0.02; HR/HD 5-Line, P = 0.0005; HR/OP, P < 0.0001). Conclusions: Our data suggest that the reproducibility for SDOCT parameters of DRIL and intraretinal cysts was high across all five SDOCT scan types; thus, evaluation of DRIL is feasible using multiple SDOCT models in eyes with DME. Translational Relevance: DME morphological changes can be evaluated on multiple SDOCT devices with good reproducibility, allowing clinicians and researchers flexibility in DME assessment for clinical care and research.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Estudos Transversais , Retinopatia Diabética/diagnóstico , Angiofluoresceinografia , Seguimentos , Humanos , Edema Macular/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual
12.
J Glaucoma ; 29(8): 704-710, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32398592

RESUMO

PRéCIS:: Intracameral injection of viscoelastic at the beginning of Ahmed FP7 implantation did not reduce early postoperative complication rates. PURPOSE: To evaluate early postoperative complication rates after a modified technique in which the anterior chamber (AC) is filled with viscoelastic at the beginning of Ahmed FP7 implantation before conjunctival peritomy. SUBJECTS AND METHODS: A retrospective chart review was performed of eyes that underwent Ahmed FP7 implantation with or without viscoelastic fill to ~20 mm Hg by finger tension by a single surgeon (M.R.M). Viscoelastic prevented the AC from becoming shallow at any time during surgery, and additional viscoelastic was injected into the AC at the end of surgery to achieve a final intraocular pressure (IOP) of 20 mm Hg. RESULTS: A total of 159 eyes of 159 patients were included. Mean age was 76.4±10.4 years. Mean preoperative IOP was 30.3±9.7 mm Hg on 2.7±1.2 glaucoma medications. On postoperative day 1, there was an IOP spike ≥30 mm Hg in 0% of patients. Within the first postoperative month, hypotony (<5 mm Hg) occurred in 19 (21.8%) eyes that received viscoelastic fill compared with 5 (13.2%) eyes that did not receive viscoelastic fill (P=0.26). During the early postoperative period (≤3 mo), there was no difference in AC depth, microhyphema, choroidal effusion, or leakage between the 2 groups (P≥0.30 for all). There was a higher rate of layered hyphemas in the viscoelastic-fill group at postoperative week 1 (P=0.01). At 3-month follow-up, mean IOP was 14.9±5.5 mm Hg on 1.6±0.8 medications in the viscoelastic-fill group and 16.0±5.2 mm Hg on 1.0±1.2 medications in the nonviscoelastic-fill group (IOP P=0.35). Compared with baseline, change in IOP at 3 months was similar between both groups (P=0.15). Rates of additional medications and procedures did not differ between the 2 groups at any postoperative visit. CONCLUSIONS: Early intracameral injection of viscoelastic during Ahmed glaucoma valve implantation did not reduce early postoperative complication rates.


Assuntos
Câmara Anterior/efeitos dos fármacos , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Ácido Hialurônico/administração & dosagem , Implantação de Prótese , Viscossuplementos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/cirurgia , Túnica Conjuntiva/cirurgia , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tonometria Ocular/efeitos adversos , Trabeculectomia/métodos , Resultado do Tratamento , Acuidade Visual/fisiologia
13.
Ophthalmol Glaucoma ; 3(2): 97-102, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32672601

RESUMO

PURPOSE: Selective laser trabeculoplasty (SLT) is a common procedure to lower intraocular pressure (IOP) in patients with glaucoma. However, reports are conflicting regarding what factors contribute to SLT success. The purpose of this study was to determine predictors of SLT success. DESIGN: Retrospective case series. PARTICIPANTS: All patients treated with SLT between January 1, 2012, and June 30, 2018. METHODS: Baseline, demographic, procedural, and ophthalmic examination data were recorded at the time of first SLT treatment. Intraocular pressure and medication data were recorded at all follow-up visits. MAIN OUTCOME MEASURES: Selective laser trabeculoplasty success was defined as IOP decrease of 20% or more from baseline at the 3-month, 6-month, and 12-month follow-up visits. Eyes were considered to have failed and were censored when additional SLT or glaucoma surgery was performed. Patients were excluded if they had less than 3 months of follow-up. RESULTS: A total of 997 eyes from 677 patients were included in the study. Mean age was 70.2±11.5 years. Selective laser trabeculoplasty success was achieved in 227 eyes (22.8%), whereas 770 eyes (77.2%) did not meet success criteria. Intraocular pressure before SLT was 21.9±5.2 mmHg while taking 2.0±1.2 medications in eyes with successful SLT, compared with 19.0±5.0 mmHg (P < 0.0001) while taking 2.1±1.3 medications (P = 0.52) in eyes with SLT failure. At the 1-year follow-up, mean IOP in eyes with SLT success was 14.7±3.2 mmHg with 2.0±1.2 medications, compared with 16.3±4.7 mmHg (P = 0.008) with a mean of 1.9±1.3 medications (P = 0.37) in eyes with SLT failure. Eyes with SLT success more often showed greater angle pigment (P = 0.03). Age, glaucoma severity, total SLT power, type of glaucoma, severity of glaucoma, visual field mean defect, and retinal nerve fiber layer thickness were not found to correlate with success. No difference was found between the rate of success based on treatments before SLT, whether surgical or medical. CONCLUSIONS: In this large cohort of eyes undergoing SLT, greater IOP and angle pigment before SLT correlated positively with SLT success. Age, total SLT power, severity of glaucoma, and prior treatments were not associated with SLT success or failure.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Terapia a Laser/métodos , Trabeculectomia/métodos , Acuidade Visual , Idoso , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
15.
J Glaucoma ; 28(12): 1090-1094, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31425336

RESUMO

PRéCIS:: This case series reports safe, effective implantation of XEN gel stents to treat iridocorneal endothelial (ICE) syndrome. The stents continue to function well and have not been occluded by membranes or peripheral anterior synechiae, but continued follow-up is necessary. PURPOSE: ICE syndrome-related glaucoma is often refractory to medical treatment, and traditional surgical treatment has lower success rates than typical for other types of glaucoma. We present a series of patients who were treated with XEN gel stent implantation. PATIENTS AND METHODS: Retrospective case series of 4 patients with ICE syndrome who underwent XEN with subconjunctival mitomycin C injection. RESULTS: Average preoperative intraocular pressure was 28.5 mm Hg on 3.8 glaucoma medications, and average postoperative intraocular pressure was 10.5 mm Hg on 1.0 medication. No patients required return to the operating room for additional procedures over an average of 6.9 months of follow-up. One patient had shallow anterior chamber that resolved with conservative management. Another had shallow anterior chamber that resolved with anterior chamber reformation with viscoelastic and developed nonappositional choroidal effusions that had resolved at most recent follow-up of 7 months after surgery. No XEN implants have been occluded by membrane formation or peripheral anterior synechiae. CONCLUSIONS: XEN is a safe and effective option for surgical management of ICE syndrome-related glaucoma. Further follow-up surveillance is necessary.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Síndrome Endotelial Iridocorneana/complicações , Stents , Adulto , Idoso de 80 Anos ou mais , Alquilantes/administração & dosagem , Túnica Conjuntiva/efeitos dos fármacos , Feminino , Glaucoma de Ângulo Aberto/etiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Implantação de Prótese , Estudos Retrospectivos , Tonometria Ocular , Adulto Jovem
16.
J Cataract Refract Surg ; 45(12): 1704-1710, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31856979

RESUMO

PURPOSE: To determine the efficacy, safety, and surgical outcomes of trabecular microbypass stent (iStent) surgery performed by resident trainees and attending surgeons. SETTING: Wills Eye Hospital, Philadelphia, Pennsylvania, USA. DESIGN: Retrospective case series. METHODS: Records of all patients who had microbypass stent surgery by a resident at Wills Eye Hospital were retrospectively reviewed. The attending-performed group included any patient who had a microbypass stent implanted by an attending surgeon on the same day a resident case was performed. RESULTS: Between 2016 and 2018, 31 microbypass stents were implanted by a resident supervised by an attending and 93 microbypass stents were implanted by an attending surgeon on the day a resident case was performed. The mean follow-up was 16.2 months ± 17.9 (SD). The mean intraocular pressure (IOP) decreased from 16.0 ± 4.6 mm Hg at baseline to 14.0 ± 3.1 mm Hg at most recent follow-up visit in the resident group (P = .02) and from 17.5 ± 4.8 mm Hg to 15.1 ± 4.3 mm Hg, respectively, in the attending group (P < .001). The final mean IOP and mean number of hypotensive medications were similar between the 2 groups (P = .83 and P = .12, respectively). Self-resolving hyphema occurred in 1 resident case and 2 attending cases. The resident group had 1 case of iridodialysis, which did not require additional surgery. One eye in the attending group ultimately required a trabeculectomy. CONCLUSION: Microbypass stent implantation by resident trainees with attending supervision had similar efficacy and safety as surgery performed by attending surgeons.


Assuntos
Educação de Pós-Graduação em Medicina/métodos , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Internato e Residência/métodos , Oftalmologia/educação , Malha Trabecular/cirurgia , Trabeculectomia/educação , Idoso , Competência Clínica , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
17.
J Glaucoma ; 28(5): 473-480, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30839415

RESUMO

PRéCIS:: This retrospective study found that combined phacoemulsification and endocyclophotocoagulation reduced intraocular pressure (IOP) to a greater degree in angle-closure glaucoma versus open-angle glaucoma and was effective for all stages of glaucoma. PURPOSE: Endocyclophotocoagulation (ECP) laser treatment of the ciliary processes is believed to decrease IOP by reducing aqueous production. Anecdotal experience in angle-closure glaucoma suggests that it may also lower IOP by opening the drainage angle to promote aqueous outflow. This study sought to evaluate combined phacoemulsification and ECP (phaco/ECP) in eyes with different types and stages of glaucoma. PATIENTS AND METHODS: A Retrospective chart review of eyes that underwent phaco/ECP between October 2010 and December 2016 at one institution was conducted. RESULTS: In 63 eyes of 63 patients with an average of 3.0±1.7 years of follow-up, the 22 eyes with chronic angle-closure glaucoma (CACG) had greater IOP reduction and medication reduction than the 41 eyes with primary open-angle glaucoma at both 1 year (6.4 vs. 2.1 mm Hg, P=0.01; 0.9 vs. 0.2 medications, P=0.04) and final follow-up (6.2 vs. 2.4 mm Hg, P=0.02; 0.9 vs. 0.3 medications, P=0.05). There was no difference in IOP reduction or medication reduction for eyes with mild, moderate, or advanced glaucoma at both 1 year (3.5, 3.9, 0.5 mm Hg, respectively, P=0.18; 0.3, 0.6, 0.4 medications, P=0.58) and final follow-up (3.3, 4.8, 0.7 mm Hg, P=0.11; 0.1, 0.8, 0.4 medications, P=0.14). CONCLUSIONS: Eyes with CACG were more responsive to phaco/ECP in terms of IOP and medication reduction compared with eyes with primary open-angle glaucoma. This finding could be partially or entirely due to concurrent cataract extraction and greater CACG preoperative IOP. Phaco/ECP was effective in all stages of glaucoma.


Assuntos
Endoscopia/métodos , Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Terapia a Laser/métodos , Facoemulsificação/métodos , Idoso , Idoso de 80 Anos ou mais , Corpo Ciliar/cirurgia , Terapia Combinada , Endoscopia/efeitos adversos , Feminino , Glaucoma de Ângulo Fechado/patologia , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Aberto/patologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento
18.
Digit J Ophthalmol ; 24(2): 16-23, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30800009

RESUMO

Purpose: Understanding patients' attitudes toward novel therapeutic options can help guide providers in personalizing treatment regimens for glaucoma patients. This study aimed to determine factors associated with acceptance of new drug delivery options among glaucoma patients. Methods: A total of 199 patient volunteers participated in an interviewer-administered survey from June to August 2016 at the Glaucoma Service of Massachusetts Eye and Ear. The questionnaire was designed to determine acceptance of 6 drug delivery approaches: (1) triple combination eye drop, (2) microdose eye spray, (3) drug-eluting contact lens, (4) drug-eluting periocular ring insert, (5) injectable subconjunctival drug insert, and (6) injectable anterior chamber implant. Other factors analyzed included self-reported demographics, disease severity, and prior ocular history. Results: The average respondent age was 63.2 ± 15.1 years; 48% were female. For approaches 1-6 listed above, overall acceptance rates were, respectively, 85%, 54%, 31%, 43%, 32%, and 30%. Patients with greater disease severity and prior incisional glaucoma surgery were more likely to pursue alternatives to traditional eye drops. Conclusions: There is limited acceptance of alternatives to traditional eye drop medications among glaucoma patients. Understanding motivating factors and potential barriers to patient acceptance of novel drug delivery approaches is important in how providers will incorporate these glaucoma treatment options into practice.


Assuntos
Anti-Hipertensivos/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Glaucoma/tratamento farmacológico , Aceitação pelo Paciente de Cuidados de Saúde , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude , Lentes de Contato , Implantes de Medicamento , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/tratamento farmacológico , Soluções Oftálmicas , Adulto Jovem
19.
Invest Ophthalmol Vis Sci ; 59(13): 5633-5640, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30481280

RESUMO

Purpose: We evaluate diabetic microaneurysm (MA) features on high-resolution adaptive optics scanning laser ophthalmoscopy (AOSLO) and their correlations with visual acuity (VA) and local retinal pathology on spectral domain optical coherence tomography (SDOCT). Methods: Diabetic participants underwent VA testing and AOSLO and SDOCT imaging of MAs. AOSLO images were graded for MA dimension, wall hyperreflectivity (WH), intraluminal hyperreflectivity (IH), and perfusion pattern. SDOCTs centered on each MA were graded for disorganization of the retinal inner layers (DRIL) and other neuroretinal pathology. Results: We imaged 109 MAs (30 eyes). Multivariate modeling, including statistically significant covariates from bivariate analyses, associated WH with greater MA size (P = 0.001) and DRIL (P = 0.04). IH was associated with perfusion (P = 0.003) and MA visibility on photographs (P = 0.0001), and larger MA size with partial perfusion (P = 0.03), MA ring signs (P = 0.0002), and photographic visibility (P = 0.01). Multivariate modeling revealed an association of WH and VA with DRIL. Conclusions: AOSLO imaging demonstrates associations of hyperreflective MA walls with MA size and adjacent DRIL, as well as the presence of DRIL with lower VA. This study identifies a correlation between vascular and neural pathology associated with VA decline. Further studies of MA structure and neuroretinal disorganization may enable novel approaches to assess anatomic and functional outcomes in the diabetic eye.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Microaneurisma/diagnóstico por imagem , Retina/fisiopatologia , Vasos Retinianos/diagnóstico por imagem , Acuidade Visual/fisiologia , Adulto , Estudos Transversais , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Diabetes Mellitus Tipo 1/fisiopatologia , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Diabetes Mellitus Tipo 2/fisiopatologia , Retinopatia Diabética/fisiopatologia , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia/métodos , Óptica e Fotônica , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA