Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-37410927

RESUMO

Plastic packaging waste, such as polyethylene terephthalate (PET) has increased significantly in recent decades, arousing a considerable and serious public concern regarding the environment, economy, and policy. Plastic recycling is a useful tool to mitigate this issue. Here, a feasible study was performed to investigate the potential of a novel method for identifying virgin and recycled PET. Ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) was combined with various chemometrics, as a simple and reliable method that achieved a high discrimination rate for 105 batches of virgin PET (v-PET) and recycled PET (r-PET) based on 202 non-volatile organic compounds (NVOCs). Making use of orthogonal partial least-squares discrimination analysis (OPLS-DA) together with non-parametric tests, 26 marker compounds (i.e. 12 intentionally added substances (IAS) and 14 non-intentionally added substances (NIAS) as well as 31 marker compounds (i.e. 11 IAS and 20 NIAS) obtained from positive and combination of positive and negative ionization modes of UPLC-Q-TOF-MS, respectively, were successfully identified. Moreover, 100% accuracy was obtained using a decision tree (DT). Cross-discrimination based on misclassified samples using various chemometrics allowed the prediction accuracy to be improved and to identify a large sample set, thus greatly enhancing the application scope of this method. The possible origins of these detected compounds can be the plastic itself, as well as contamination from food, medicine, pesticides, industry-related substances, and degradation and polymerization products. As many of these compounds are toxic, especially those pesticide related, this indicates an urgent requirement for closed loop recycling. Overall, this analytical method provides a quick, accurate, and robust way to distinguish virgin from recycled PET and thus addresses the issue of potential virgin PET adulteration thereby detecting fraud in the area of PET recycling.


Assuntos
Quimiometria , Polietilenotereftalatos , Polietilenotereftalatos/análise , Espectrometria de Massas/métodos , Cromatografia Líquida , Plásticos/análise , Cromatografia Líquida de Alta Pressão/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-36538705

RESUMO

Plastic take-out food containers may release microplastics (MPs) into food and pose a potential risk to food safety and human health. Here, after being subjected to hot water treatment, MPs released from three types of plastic food containers (polypropylene, PP; polyethylene, PE; expanded polystyrene, EPS) were identified by micro-Raman spectroscopy. The results showed that the size of released MPs ranged from 0.8-38 µm and over 96% MPs were smaller than 10 µm. Various MPs concentrations were found from the three types of containers, that is, 1.90 × 104, 1.01 × 105, and 2.82 × 106 particles/L on average from PP, PE, and EPS, respectively. Moreover, based on thermal and morphology analysis, we discovered that both relaxations of the polymer chains in the rubbery state and defects caused by processing techniques might contribute to the release of MPs. Thus, such release can be reduced by increasing the thermal stability of the materials and mitigating the defects generated during production.


Assuntos
Plásticos , Poluentes Químicos da Água , Humanos , Plásticos/análise , Microplásticos/análise , Embalagem de Alimentos , Monitoramento Ambiental , Poluentes Químicos da Água/análise
3.
Artigo em Inglês | MEDLINE | ID: mdl-37831931

RESUMO

The objective was to establish a robust and reliable approach for the characterisation of volatile organic compounds (VOCs) present in food contact paperboard. This was achieved through the utilisation of headspace solid-phase microextraction in tandem with comprehensive two-dimensional (2D) gas chromatography (GC) and quadrupole time-of-flight mass spectrometry (HS-SPME-GC × GC-QTOF-MS). The experimental parameters were optimised, involving the use of a DVB/C-WR/PDMS fibre at a temperature of 80 °C for a duration of 30 min. A total of 344 VOCs comprising aldehydes, ketones, alcohols, ethers, esters, alkanes and aromatic compounds, were tentatively identified in the samples. Twelve compounds believed to be from biogenic sources had a high odour impact making them major contributors to potential taint from the paperboard samples. Significant attention should be devoted to five compounds namely, 2-methylnaphthalene, 2-pentyl-furan, furfural, 1-octen-3-one and 1-octen-3-ol due to their potential adverse impact on the organoleptic qualities of packaged food items and their potential toxicity.Abbreviations: C-WR: carbon wide range; DVB: divinylbenzene; GC-MS: gas chromatography - mass spectrometry; GCxGC-QTOF-MS: comprehensive two-dimensional gas chromatography coupled to quadrupole-time-of-flight - mass spectrometry; HS-SPME: headspace - solid phase microextraction; LOD: limit of detection; LOQ: limit of quantification; OAV: odor activity values; PDMS: polydimethylsiloxane; RI: retention index; TTC: threshold of toxicological concern; VOC: volatile organic compound.


Assuntos
Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/análise , Odorantes/análise , Microextração em Fase Sólida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Aldeídos/análise
4.
J Hazard Mater ; 423(Pt B): 127165, 2022 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-34844336

RESUMO

A growing attention is attracted to the use of recycled plastics as food contact materials, and its chemical safety research and discrimination approach are indispensable. In current study, ultraviolet-visible spectrometry (UV-Vis) and ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) were used to provide spectral and mass fingerprinting for polyethylene (PE). Coupling with chemometrics, two methods were developed to discriminate recycled and virgin PE. UV-Vis combined with chemometrics could be a more accessible, simpler and faster approach. 237-331 nm in UV spectrum was regarded as marker region selected by orthogonal partial least-squares discrimination analysis (OPLS-DA) and the accuracy of both calibration and validation set could reach 100% in linear discrimination analysis (LDA) based on this region. Besides, 2314 ions were detected by UPLC-Q-TOF-MS and processed by MS-DIAL. 48 candidate chemicals were identified, including ketone, esters, carboxylic acid, alcohols and phenols, amine, nitriles, aldehydes and others. Possible origins of these compounds could be classified as plastic, food, drug, cosmetics and pesticide related. Many of these compounds are highly toxic, especially pesticide related, indicating that recycling in closed loop or sorting by the recycled plastic articles is very necessary if the recycled PE is going to be used as food contact material.


Assuntos
Quimiometria , Polietileno , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Espectrometria de Massas
5.
Materials (Basel) ; 14(16)2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34443068

RESUMO

In this study, we prepared new antioxidant active plastic bottle caps by incorporating butylated hydroxyanisole (BHA) or butylated hydroxytoluene (BHT) and 2% (w/w) white masterbatch in high-density polyethylene (HDPE). Fourier-transform infrared (FT-IR) spectrometry revealed that the antioxidants and HDPE were uniformly mixed with noncovalent bonding. In addition, the differential scanning calorimetry (DSC) test revealed that the change in melting point and initial extrapolation temperature of the antioxidant active caps was not significant. Sensory evaluation and removal torque tests validated the suitability of the antioxidant active plastic bottle caps in industrial application. The antioxidant activity increased with a greater concentration of BHA and BHT incorporated in both antioxidant active caps (p < 0.05) and with more impact on the BHA cap compared to BHT cap in terms of antioxidant activity. Migration experiments for 10 days at 40 °C and 2 h at 70 °C showed that active antioxidants in the plastic bottle cap were more easily released into fatty foods and milk products that are highly sensitive to oxidation, and the migration of BHA and BHT did not exceed the maximum amount specified in (EC) No 1333/2008 (<200 mg/kg). As such, the antioxidant active plastic bottle caps inhibited oxidation, thereby ensuring higher food quality.

6.
Talanta ; 202: 285-296, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31171184

RESUMO

Atmospheric pressure gas chromatography (APGC) coupled to quadrupole time-of-flight (QTOF) and electron ionization mass spectrometry together with commercial library search are two complementary techniques for non-target screening of volatile and semi-volatile compounds. Optimization was first conducted to achieve easier search of correspondent peaks between the two systems. Analytical strategy for the determination of volatile and semi-volatile compound with different identification confidence levels was then proposed and applied to food contact grade polypropylene (PP) samples. Identification was found to be much easier and less time-consuming especially when correspondent peak was found in the two systems with the help of library search, exact mass of precursor and fragment ions as well as Kovats Index (KI). The behavior of APGC-QTOF-MS was also further investigated. Apart from the M+. ion and the well-known adduct [M+H]+ others such as [M-3H + O]+, [M-3H+2O]+ and [M-H+3O]+ were also observed for n-alkanes. Besides, new reaction products were found, formed by diol compounds (1-Monostearoylglycerol, 2-Monostearoylglycerol and NX 8000K) and silanediol dimethyl, which would be a transformation product of the silicone base septum or the methyl 5% phenyl polysiloxane based column. These new compounds were only detected in APGC-MS-QTOF as EI-GC-MS was not enough sensitive for this purpose.

7.
Artigo em Inglês | MEDLINE | ID: mdl-30303757

RESUMO

A rapid and sensitive method for classification of virgin and recycled expanded polystyrene (EPS) food containers was developed using Fourier transform infrared spectroscopy (FTIR) and chemometrics. This method includes preparing a transparent film by dissolution, examining by FTIR and developing classification models. The degradation of EPS containers occurring during the recycling process was reflected by the carbonyl region of the infrared spectrum which was used as variables for multivariate data analysis. PCA was used to reduce the data dimension and view the sample similarities. Soft independent modelling of class analogy (SIMCA), partial least squares-discrimination analysis (PLS-DA) and linear discrimination analysis (LDA) were applied to construct three classification models. The best discrimination results were obtained by an LDA model, with all samples correctly classified. PLS-DA and SIMCA could not classify the recycled EPS samples with low levels of adulteration. When applying this method to commercially available EPS containers, about 45% of samples were shown to contain recycled polystyrene resins. It is concluded that the carbonyl region of the infrared spectra coupled with chemometrics could be a powerful tool for the classification of virgin and recycled EPS food containers.


Assuntos
Análise de Alimentos , Contaminação de Alimentos/análise , Poliestirenos/análise , Análise dos Mínimos Quadrados , Espectroscopia de Infravermelho com Transformada de Fourier
8.
Artigo em Inglês | MEDLINE | ID: mdl-28346078

RESUMO

Accurate diffusion coefficient data of additives in a polymer are of paramount importance for estimating the migration of the additives over time. This paper shows how this diffusion coefficient can be estimated for three plastic additives [2-(2'-hydroxy-5'-methylphenyl) (UV-P), 2,6-di-tert-butyl-4-methylphenol (BHT) and di-(2-ethylhexyl) phthalate (DEHP)] in polyethylene terephthalate (PET) using the molecular dynamics (MD) simulation method. MD simulations were performed at temperatures of 293-433 K. The diffusion coefficient was calculated through the Einstein relationship connecting the data of mean-square displacement at different times. Comparison of the diffusion coefficients simulated by the MD simulation technique, predicted by the Piringer model and experiments, showed that, except for a few samples, the MD-simulated values were in agreement with the experimental values within one order of magnitude. Furthermore, the diffusion process for additives is discussed in detail, and four factors - the interaction energy between additive molecules and PET, fractional free volume, molecular shape and size, and self-diffusion of the polymer - are proposed to illustrate the microscopic diffusion mechanism. The movement trajectories of additives in PET cell models suggested that the additive molecules oscillate slowly rather than hopping for a long time. Occasionally, when a sufficiently large hole was created adjacently, the molecule could undergo spatial motion by jumping into the free-volume hole and consequently start a continuous oscillation and hop. The results indicate that MD simulation is a useful approach for predicting the microstructure and diffusion coefficient of plastic additives, and help to estimate the migration level of additives from PET packaging.


Assuntos
Simulação de Dinâmica Molecular , Plásticos/análise , Polietilenotereftalatos/química , Difusão , Embalagem de Alimentos
9.
Food Chem ; 228: 560-566, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28317763

RESUMO

The effects of organic additives (Irgafos 168, Irganox 1076, Tinuvin 622, Chimassorb 944, UV-P, and UV-531) on silver release from nanosilver-polyethylene composite films into an acidic food simulant (3% acetic acid) were investigated using inductively coupled plasma mass spectrometry. The limits of detection and quantification, coefficient of determination, and recoveries of the method used were 3.7ngL-1, 12.4ngL-1, 0.999, and 89-113%, respectively. The results indicated that additives can affect silver release via two simultaneous processes: (i) reactions between organic additives and silver that promote silver release from the composite film to the acidic food simulant; and (ii) the promotion or inhibition of silver release by affecting silver oxidation. High temperature and humidity treatment of the composite films was found to significantly increase silver release by promoting silver oxidation.


Assuntos
Contaminação de Alimentos/análise , Embalagem de Alimentos/métodos , Polietileno/química , Prata/química
10.
Artigo em Inglês | MEDLINE | ID: mdl-27801633

RESUMO

The migration of styrene and ethylbenzene from virgin and recycled expanded polystyrene (EPS) containers into isooctane was investigated using gas chromatography-mass spectrometry (GC-MS). EPS containers were in two-sided contact with isooctane at temperatures of 25 and 40°C. It was shown that recycled EPS gave greater migration ratios compared with virgin EPS, which indicated that styrene and ethylbenzene migrated more easily from recycled EPS. In addition, an analytical method to distinguish between virgin and recycled EPS containers was established by GC-MS followed by principal component analysis (PCA). The relative peak area of the identified compounds was used as input data for PCA. Distinct separation between virgin and recycled EPS was achieved on a score plot. Extension of this method to other plastics may be of great interest for recycled plastics identification.


Assuntos
Derivados de Benzeno/química , Poliestirenos/química , Estireno/química , Cromatografia Gasosa-Espectrometria de Massas , Análise de Componente Principal
11.
J Chromatogr Sci ; 54(6): 939-51, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26941413

RESUMO

This study investigates the determination and migration of stabilizers and plasticizers from polyethylene terephthalate (PET). Two methods [ultrasonic extraction with dichloromethane or methanol and total dissolution with phenol/tetrachloroethane (m:m/1:1)] for pre-concentration of additives in PET material were performed. The diffusion of these additives from PET was evaluated by immersing in deionized water, acetic acid 3% (w/v), ethanol 20% (v/v), ethanol 50% (v/v) and isooctane at 20, 40, 55 and 70°C, respectively. The amount of additives in PET and food simulants was quantified by high-performance liquid chromatography-photodiode array detector (HPLC-PDA). The optimized HPLC method showed high correlation coefficients (R ≥ 0.9993), good precision, accuracy and reproducibility. Experimental diffusion coefficients (DP) were calculated according to a mathematical model based on Fick's second law, and the DP values of considered compounds ranged from 9.8 × 10(-15) to 1.4 × 10(-8) cm(2) s(-1) The experimental DP values were also compared with that predicted by currently used diffusion models. In addition, the effect of temperature on the diffusion rate was assessed. The effect of temperature on the diffusion coefficients followed an Arrhenius-type model with active energies ranged from 40.4 to 113.8 kJ mol(-1) for the target compounds.


Assuntos
Análise de Alimentos/métodos , Plastificantes/análise , Polietilenotereftalatos/análise , Cromatografia Líquida de Alta Pressão , Difusão , Contaminação de Alimentos/análise , Embalagem de Alimentos , Modelos Teóricos , Polietilenotereftalatos/química , Reprodutibilidade dos Testes , Temperatura
12.
J Chromatogr Sci ; 53(6): 1026-35, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25472804

RESUMO

An analytical method for the quantitative determination of 4 antioxidants, 9 ultraviolet (UV) stabilizers, 12 phthalate plasticizers and 2 photoinitiators in plastic food package using accelerated solvent extraction (ASE) coupled with high-performance liquid chromatography-photodiode array detector (HPLC-PDA) has been developed. Parameters affecting the efficiency in the process such as extraction and chromatographic conditions were studied in order to determine operating conditions. The analytical method of ASE-HPLC showed good linearity with good correlation coefficients (R ≥ 0.9833). The limits of detection and quantification were between 0.03 and 0.30 µg mL(-1) and between 0.10 and 1.00 µg mL(-1) for 27 analytes. Average spiked recoveries for most analytes in samples were >70.4% at 10, 20 and 40 µg g(-1) spiked levels, except UV-9 and Irganox 1010 (58.6 and 64.0% spiked at 10 µg g(-1), respectively), the relative standard deviations were in the range from 0.4 to 15.4%. The methodology has been proposed for the analysis of 27 polymer additives in plastic food package.


Assuntos
Antioxidantes/análise , Cromatografia Líquida de Alta Pressão/métodos , Embalagem de Alimentos , Plastificantes/química , Plásticos/química , Excipientes/análise , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Sonicação
13.
Artigo em Inglês | MEDLINE | ID: mdl-26209184

RESUMO

The effect of exposure time, temperature and food simulants, especially additives, on the release of silver from nanosilver-polyethylene composite films to food simulants was studied. Two different type of nanosilver-polyethylene composite films (with or without additives) were chosen to conduct the experiment with the aim of exploring the behaviour of silver migration. It was shown that the migration of silver into 50% ethanol at 40 and 70°C was much less than that into 3% acetic acid. With the increase of exposure time and temperature, the release of silver increased. The migration even continued after a long exposure time (14 days at 20°C, 10 days at 40°C, and 6 days at 70°C respectively). Only about 0.15‰ of silver migrated from composite films with the additives into 3% acetic acid after 6 days of exposure at 70°C, while about 1.3% of silver migrated from composite films that did not contain additives under the same conditions. This could be because the addition of the antioxidants and light stabilisers prevents silver from being oxidised, which is an important way for the release of silver.


Assuntos
Antioxidantes/química , Aditivos Alimentares/química , Análise de Alimentos , Embalagem de Alimentos , Luz , Nanopartículas Metálicas/química , Polietileno/química , Prata/análise , Acetatos/química , Etanol/química , Temperatura , Fatores de Tempo
14.
Artigo em Inglês | MEDLINE | ID: mdl-24666013

RESUMO

An analytical method based on ICP-MS was developed for the determination of Ti in food simulants (3% (w/v) aqueous acetic acid and 50% (v/v) aqueous ethanol). The method was used to determine the migration of Ti from nano-TiO2-PE films used for food packaging into food simulants under different temperature and migration time conditions. The maximum migration amounts into 3% (w/v) aqueous acetic acid were 1.4 ± 0.02, 6.3 ± 0.5 and 12.1 ± 0.2 µg kg(-1) at 25, 70 and 100°C, respectively, while into 50% (v/v) aqueous ethanol, the maximum migration amounts were 0.5 ± 0.1, 0.6 ± 0.03 and 2.1 ± 0.1 µg kg(-1) at 25, 70 and 100°C, respectively. Increasing the additive content in the film promoted migration of nanoparticles. The results indicated that the migration of nanoparticles might occur via dissolution from the surface and cut edges of the solid phase (film) into the liquid phase (food simulant).


Assuntos
Contaminação de Alimentos/análise , Embalagem de Alimentos , Nanopartículas Metálicas/química , Titânio/análise , Ácido Acético , Etanol , Humanos , Limite de Detecção , Espectrometria de Massas , Nanopartículas Metálicas/toxicidade , Nanopartículas Metálicas/ultraestrutura , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Nanocompostos/química , Nanocompostos/toxicidade , Nanocompostos/ultraestrutura , Tamanho da Partícula , Polietileno , Titânio/toxicidade , Água
15.
J Agric Food Chem ; 59(18): 9800-5, 2011 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-21848254

RESUMO

A highly selective and sensitive method was developed for the simultaneous determination of 12 sulfonamides in beef and milk by immunoaffinity chromatography purification coupled to ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The MS/MS conditions, UPLC mobile phase, injection solution, sample purification process, and matrix effect were studied to optimize the operating conditions. The limits of detection (LODs) of the instrument for the studied sulfonamides ranged from 0.4 to 2.0 µg L(-1), being 1.6-8.0 µg kg(-1) for beef and 1.8-6.4 µg kg(-1) for milk. The standard solution was diluted with blank beef or milk matrix for the construction of calibration curves, which had a linear range from 10 to 200 µg kg(-1) and regression coefficients higher than 0.990 (n=10) for all the studied sulfonamides. Samples spiked at 10, 20, and 100 µg kg(-1) showed recoveries above 70% and relative standard deviations below 10%.


Assuntos
Cromatografia de Afinidade/métodos , Cromatografia Líquida de Alta Pressão/métodos , Carne/análise , Leite/química , Sulfonamidas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Calibragem , Bovinos , Contaminação de Alimentos/análise , Imunoensaio/métodos , Limite de Detecção , Reprodutibilidade dos Testes , Drogas Veterinárias/análise
16.
J Chromatogr Sci ; 48(1): 7-11, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20056028

RESUMO

A new method using gel permeation chromatography (GPC) cleanup followed by ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS-MS) has been established for simultaneous determination of 18 carbamate pesticides in nuts (chestnut and pine nut). Recoveries obtained by fortifying nut (spiking at 0.02 mg/kg) range from 70.21% to 89.56%. The proposed method features good sensitivity. Its limits of quantification are low enough to allow pesticide residues to be determined at concentrations below the maximum residue levels legally accepted. The precision, expressed as relative standard deviation, ranges from 2.26% to 4.07%.


Assuntos
Carbamatos/análise , Cromatografia em Gel/métodos , Cromatografia Líquida de Alta Pressão/métodos , Nozes/química , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia em Gel/economia , Cromatografia Líquida de Alta Pressão/economia , Fagaceae/química , Limite de Detecção , Pinus/química , Espectrometria de Massas em Tandem/economia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA