Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 212
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Med Genet ; 60(9): 850-858, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36669872

RESUMO

BACKGROUND: A small but significant reduction in left ventricular (LV) mass after 18 months of migalastat treatment has been reported in Fabry disease (FD). This study aimed to assess the effect of migalastat on FD cardiac involvement, combining LV morphology and tissue characterisation by cardiac magnetic resonance (CMR) with cardiopulmonary exercise testing (CPET). METHODS: Sixteen treatment-naïve patients with FD (4 women, 46.4±16.2 years) with cardiac involvement (reduced T1 values on CMR and/or LV hypertrophy) underwent ECG, echocardiogram, troponin T and NT-proBNP (N-Terminal prohormone of Brain Natriuretic Peptide) assay, CMR with T1 mapping, and CPET before and after 18 months of migalastat. RESULTS: No change in LV mass was detected at 18 months compared to baseline (95.2 g/m2 (66.0-184.0) vs 99.0 g/m2 (69.0-121.0), p=0.55). Overall, there was an increase in septal T1 of borderline significance (870.0 ms (848-882) vs 860.0 ms (833.0-875.0), p=0.056). Functional capacity showed an increase in oxygen consumption (VO2) at anaerobic threshold (15.50 mL/kg/min (13.70-21.50) vs 14.50 mL/kg/min (11.70-18.95), p=0.02), and a trend towards an increase in percent predicted peak VO2 (72.0 (63.0-80.0) vs 69.0 (53.0-77.0), p=0.056) was observed. The subset of patients who showed an increase in T1 value and a reduction in LV mass (n=7, 1 female, age 40.5 (28.6-76.0)) was younger and at an earlier disease stage compared to the others, and also exhibited greater improvement in exercise tolerance. CONCLUSION: In treatment-naïve FD patients with cardiac involvement, 18-month treatment with migalastat stabilised LV mass and was associated with a trend towards an improvement in exercise tolerance. A tendency to T1 increase was detected by CMR. The subset of patients who had significant benefits from the treatment showed an earlier cardiac disease compared to the others. TRIAL REGISTRATION NUMBER: NCT03838237.


Assuntos
Doença de Fabry , Cardiopatias , Humanos , Feminino , Adulto , Imageamento por Ressonância Magnética , 1-Desoxinojirimicina , Valor Preditivo dos Testes
2.
Int J Mol Sci ; 25(17)2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39273120

RESUMO

PRKAG2 cardiomyopathy is a rare genetic disorder that manifests early in life with an autosomal dominant inheritance pattern. It harbors left ventricular hypertrophy (LVH), ventricular pre-excitation and progressively worsening conduction system defects. Its estimated prevalence among patients with LVH ranges from 0.23 to about 1%, but it is likely an underdiagnosed condition. We report the association of the PRKAG2 missense variant c.1006G>A p. (Val336Ile) with LVH, conduction abnormalities (short PR interval and incomplete right bundle branch bock) and early-onset arterial hypertension (AH) in a 44-year-old Caucasian patient. While cardiac magnetic resonance (CMR) showed a mild hypertrophic phenotype with maximal wall thickness of 17 mm in absence of tissue alterations, the electric phenotype was relevant including brady-tachy syndrome and recurrent syncope. The same variant has been detected in the patient's sister and daughter, with LVH + early-onset AH and electrocardiographic (ECG) alterations + lipothymic episodes, respectively. Paying close attention to the coexistence of LVH and ECG alterations in the proband has been helpful in directing genetic tests to exclude primary cardiomyopathy. Hence, identifying the genetic basis in the patient allowed for familial screening as well as a proper follow-up and therapeutic management of the affected members. A review of the PRKAG2 cardiomyopathy literature is provided alongside the case report.


Assuntos
Proteínas Quinases Ativadas por AMP , Hipertrofia Ventricular Esquerda , Mutação de Sentido Incorreto , Humanos , Adulto , Hipertrofia Ventricular Esquerda/genética , Feminino , Proteínas Quinases Ativadas por AMP/genética , Eletrocardiografia , Masculino , Linhagem
3.
Radiology ; 307(3): e222239, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36943075

RESUMO

Background Scar burden with late gadolinium enhancement (LGE) cardiac MRI (CMR) predicts arrhythmic events in patients with postinfarction in single-center studies. However, LGE analysis requires experienced human observers, is time consuming, and introduces variability. Purpose To test whether postinfarct scar with LGE CMR can be quantified fully automatically by machines and to compare the ability of LGE CMR scar analyzed by humans and machines to predict arrhythmic events. Materials and Methods This study is a retrospective analysis of the multicenter, multivendor CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry. Patients with chronic heart failure, echocardiographic left ventricular ejection fraction (LVEF) of less than 50%, and LGE CMR were recruited (from January 2015 through December 2020). In the current study, only patients with ischemic cardiomyopathy were included. Quantification of total, dense, and nondense scars was carried out by two experienced readers or a Ternaus network, trained and tested with LGE images of 515 and 246 patients, respectively. Univariable and multivariable Cox analyses were used to assess patient and cardiac characteristics associated with a major adverse cardiac event (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare model performances. Results In 761 patients (mean age, 65 years ± 11, 671 men), 83 MACEs occurred. With use of the testing group, univariable Cox-analysis found New York Heart Association class, left ventricle volume and/or function parameters (by echocardiography or CMR), guideline criterion (LVEF of ≤35% and New York Heart Association class II or III), and LGE scar analyzed by humans or the machine-learning algorithm as predictors of MACE. Machine-based dense or total scar conferred incremental value over the guideline criterion for the association with MACE (AUC: 0.68 vs 0.63, P = .02 and AUC: 0.67 vs 0.63, P = .01, respectively). Modeling with competing risks yielded for dense and total scar (AUC: 0.67 vs 0.61, P = .01 and AUC: 0.66 vs 0.61, P = .005, respectively). Conclusion In this analysis of the multicenter CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry, fully automatic machine learning-based late gadolinium enhancement analysis reliably quantifies myocardial scar mass and improves the current prediction model that uses guideline-based risk criteria for implantable cardioverter defibrillator implantation. ClinicalTrials.gov registration no.: NCT03352648 Published under a CC BY 4.0 license. Supplemental material is available for this article.


Assuntos
Cicatriz , Meios de Contraste , Masculino , Humanos , Idoso , Volume Sistólico , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Função Ventricular Esquerda , Imageamento por Ressonância Magnética/métodos , Sistema de Registros , Inteligência Artificial , Valor Preditivo dos Testes
4.
Radiology ; 306(1): 112-121, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098639

RESUMO

Background Patients with mitral valve prolapse (MVP) may develop adverse outcomes even in the absence of mitral regurgitation or left ventricular (LV) dysfunction. Purpose To investigate the prognostic value of mitral annulus disjunction (MAD) and myocardial fibrosis at late gadolinium enhancement (LGE) cardiac MRI in patients with MVP without moderate-to-severe mitral regurgitation or LV dysfunction. Materials and Methods In this longitudinal retrospective study, 118 144 cardiac MRI studies were evaluated between October 2007 and June 2020 at 15 European tertiary medical centers. Follow-up was from the date of cardiac MRI examination to June 2020; the minimum and maximum follow-up intervals were 6 months and 156 months, respectively. Patients were excluded if at least one of the following conditions was present: cardiomyopathy, LV ejection fraction less than 40%, ischemic heart disease, congenital heart disease, inflammatory heart disease, moderate or worse mitral regurgitation, participation in competitive sport, or electrocardiogram suggestive of channelopathies. In the remainder, cardiac MRI studies were reanalyzed, and patients were included if they were aged 18 years or older, MVP was diagnosed at cardiac MRI, and clinical information and electrocardiogram monitoring were available within 3 months from cardiac MRI examination. The end point was a composite of adverse outcomes: sustained ventricular tachycardia (VT), sudden cardiac death (SCD), or unexplained syncope. Multivariable Cox regression analysis was performed. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 women) were included. Over a median follow-up of 3.3 years, 18 patients (4%) reached the study end point. LGE presence (hazard ratio, 4.2 [95% CI: 1.5, 11.9]; P = .006) and extent (hazard ratio, 1.2 per 1% increase [95% CI: 1.1, 1.4]; P = .006), but not MAD presence (P = .89), were associated with clinical outcome. LGE presence had incremental prognostic value over MVP severity and sustained VT and aborted SCD at baseline (area under the receiver operating characteristic curve, 0.70 vs 0.62; P = .03). Conclusion In contrast to mitral annulus disjunction, myocardial fibrosis determined according to late gadolinium enhancement at cardiac MRI was associated with adverse outcome in patients with mitral valve prolapse without moderate-to-severe mitral regurgitation or left ventricular dysfunction. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Gerber in this issue.


Assuntos
Cardiomiopatias , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/complicações , Estudos Retrospectivos , Meios de Contraste , Gadolínio , Valva Mitral , Imageamento por Ressonância Magnética , Fibrose , Morte Súbita Cardíaca
5.
J Cardiovasc Magn Reson ; 25(1): 10, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36793062

RESUMO

BACKGROUND: The use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images. METHODS: LA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking. RESULTS: Compared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias - 13 ml; LOA = + 11, - 37 ml; LAVmax i: bias - 7 ml/m2; LOA = + 7, - 21 ml/m2; LAVmin; bias - 10 ml, LOA: + 9, - 28 ml; LAVmin i: bias - 5 ml/m2, LOA: + 5, - 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, - 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, - 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, - 6 ml/m2; LAVmin: bias - 2 ml; LOA: + 7, - 10 ml; LAVmin i: bias - 1 ml/m2; LOA: + 3, - 5 ml/m2) and LAEF (bias 2%, LOA: + 11, - 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, - 11%; εe: bias 4%, LOA = 15, - 8%; εa: bias 3%, LOA = 14, - 8%) was significantly higher in standard vs. LA-focused images (p < 0.001). CONCLUSION: LA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.


Assuntos
Ecocardiografia , Átrios do Coração , Humanos , Valor Preditivo dos Testes , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
6.
Rev Cardiovasc Med ; 23(5): 177, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-39077600

RESUMO

In the past few years, the wide application of cardiac magnetic resonance (CMR) significantly changed the approach to the study of cardiac involvement in Fabry Disease (FD). The possibility to perform non-invasive tissue characterization, including new sequences such as T1/T2 mapping, offered a powerful tool for differential diagnosis with other forms of left ventricular hypertrophy. In patients with confirmed diagnosis of FD, CMR is the most sensitive non-invasive technique for early detection of cardiac involvement and it provides new insight into the evolution of cardiac damage, including gender-specific features. Finally, CMR multiparametric detection of subtle changes in cardiac morphology, function and tissue composition is potentially useful for monitoring the efficacy of specific treatment over time. This paper aims to provide a comprehensive review of current knowledge regarding the application of CMR in FD cardiac involvement and its clinical implication.

7.
J Magn Reson Imaging ; 56(4): 1157-1170, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35075711

RESUMO

BACKGROUND: Time-resolved three-directional velocity-encoded (4D flow) magnetic resonance imaging (MRI) enables the quantification of left ventricular (LV) intracavitary fluid dynamics and energetics, providing mechanistic insight into LV dysfunctions. Before becoming a support to diagnosis and patient stratification, this analysis should prove capable of discriminating between clearly different LV derangements. PURPOSE: To investigate the potential of 4D flow in identifying fluid dynamic and energetics derangements in ischemic and restrictive LV cardiomyopathies. STUDY TYPE: Prospective observational study. POPULATION: Ten patients with post-ischemic cardiomyopathy (ICM), 10 patients with cardiac light-chain cardiac amyloidosis (AL-CA), and 10 healthy controls were included. FIELD STRENGTH/SEQUENCE: 1.5 T/balanced steady-state free precession cine and 4D flow sequences. ASSESSMENT: Flow was divided into four components: direct flow (DF), retained inflow, delayed ejection flow, and residual volume (RV). Demographics, LV morphology, flow components, global and regional energetics (volume-normalized kinetic energy [KEV ] and viscous energy loss [ELV ]), and pressure-derived hemodynamic force (HDF) were compared between the three groups. STATISTICAL TESTS: Intergroup differences in flow components were tested by one-way analysis of variance (ANOVA); differences in energetic variables and peak HDF were tested by two-way ANOVA. A P-value of <0.05 was considered significant. RESULTS: ICM patients exhibited the following statistically significant alterations vs. controls: reduced KEV , mostly in the basal region, in systole (-44%) and in diastole (-37%); altered flow components, with reduced DF (-33%) and increased RV (+26%); and reduced basal-apical HDF component on average by 63% at peak systole. AL-CA patients exhibited the following alterations vs. controls: significantly reduced KEV at the E-wave peak in the basal segment (-34%); albeit nonstatistically significant, increased peaks and altered time-course of the HDF basal-apical component in diastole and slightly reduced HDF components in systole. DATA CONCLUSION: The analysis of multiple 4D flow-derived parameters highlighted fluid dynamic alterations associated with systolic and diastolic dysfunctions in ICM and AL-CA patients, respectively. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Cardiomiopatia Restritiva , Hidrodinâmica , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda
8.
Europace ; 23(7): 1072-1083, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33792661

RESUMO

AIMS: The aim of this registry was to evaluate the additional prognostic value of a composite cardiac magnetic resonance (CMR)-based risk score over standard-of-care (SOC) evaluation in a large cohort of consecutive unselected non-ischaemic cardiomyopathy (NICM) patients. METHODS AND RESULTS: In the DERIVATE registry (www.clinicaltrials.gov/registration: RCT#NCT03352648), 1000 (derivation cohort) and 508 (validation cohort) NICM patients with chronic heart failure (HF) and left ventricular ejection fraction <50% were included. All-cause mortality and major adverse arrhythmic cardiac events (MAACE) were the primary and secondary endpoints, respectively. During a median follow-up of 959 days, all-cause mortality and MAACE occurred in 72 (7%) and 93 (9%) patients, respectively. Age and >3 segments with midwall fibrosis on late gadolinium enhancement (LGE) were the only independent predictors of all-cause mortality (HR: 1.036, 95% CI: 1.0117-1.056, P < 0.001 and HR: 2.077, 95% CI: 1.211-3.562, P = 0.008, respectively). For MAACE, the independent predictors were male gender, left ventricular end-diastolic volume index by CMR (CMR-LVEDVi), and >3 segments with midwall fibrosis on LGE (HR: 2.131, 95% CI: 1.231-3.690, P = 0.007; HR: 3.161, 95% CI: 1.750-5.709, P < 0.001; and HR: 1.693, 95% CI: 1.084-2.644, P = 0.021, respectively). A composite clinical and CMR-based risk score provided a net reclassification improvement of 63.7% (P < 0.001) for MAACE occurrence when added to the model based on SOC evaluation. These findings were confirmed in the validation cohort. CONCLUSION: In a large multicentre, multivendor cohort registry reflecting daily clinical practice in NICM work-up, a composite clinical and CMR-based risk score provides incremental prognostic value beyond SOC evaluation, which may have impact on the indication of implantable cardioverter-defibrillator implantation.


Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Meios de Contraste , Feminino , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda
9.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32375896

RESUMO

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas/normas , Consenso , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
11.
J Magn Reson Imaging ; 45(4): 1055-1067, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27571232

RESUMO

PURPOSE: To define reference values of cardiac volumes, dimensions, and new morpho-functional parameters normalized for age, gender, and body surface area by cine-bSSFP (balanced steady-state free-precession) magnetic resonance (MR). MATERIALS AND METHODS: We enrolled 308 healthy subjects subdivided by gender and by six age classes: class I, >15-20 years; class II, >20-30 years; class III, >30-40 years; class IV, >40-50 years; class V, >50-60 years; and class VI >60 years. Dimensional, volumetric and morpho-functional parameters of the left (LV) and right (RV) ventricles were measured using cine-bSSFP MRI at 1.5T. RESULTS: The LV and RV end-diastolic volume indexes (EDVi) were inversely related to age (P < 0.0001 r = -0.34 and P < 0.0001 r = -0.37, respectively). In addition, the LV mass index decreased with age (P = 0.0004, r = -0.21). The LV longitudinal shortening was not significantly different among groups: ≥15% in all populations (95% confidence interval [CI]: 16-31). The sphericity index measured in end-diastole was higher in females than in males (P < 0.03): the upper limit was 40% for males and 42% for females. The normality cutoff of LV global function index was ≥33% in males and ≥35% in females. The end-diastolic volume (EDV) of RV and LV was balanced (RV/LV ratio 0.85-1.15) without differences in the population. The LV EDV/mass was 1.0-1.8 in males and 1.0-2.1 in females. CONCLUSION: This study provides potential age- and gender-specific reference. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:1055-1067.


Assuntos
Volume Cardíaco/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Fatores Etários , Feminino , Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais , Adulto Jovem
12.
Arterioscler Thromb Vasc Biol ; 36(4): 757-64, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26868212

RESUMO

OBJECTIVE: Circulating levels of high-sensitivity cardiac troponin T (hs-cTnT) and N terminal pro brain natriuretic peptide (NT-proBNP) are predictors of prognosis in patients with coronary artery disease (CAD). We aimed at evaluating the effect of coronary atherosclerosis and myocardial ischemia on cardiac release of hs-cTnT and NT-proBNP in patients with suspected CAD. APPROACH AND RESULTS: Hs-cTnT and NT-proBNP were measured in 378 patients (60.1±0.5 years, 229 males) with stable angina and unknown CAD enrolled in the Evaluation of Integrated Cardiac Imaging (EVINCI) study. All patients underwent stress imaging to detect myocardial ischemia and coronary computed tomographic angiography to assess the presence and characteristics of CAD. An individual computed tomographic angiography score was calculated combining extent, severity, composition, and location of plaques. In the whole population, the median (25-75 percentiles) value of plasma hs-cTnT was 6.17 (4.2-9.1) ng/L and of NT-proBNP was 61.66 (31.2-132.6) ng/L. In a multivariate model, computed tomographic angiography score was an independent predictor of the plasma hs-cTnT (coefficient 0.06, SE 0.02; P=0.0089), whereas ischemia was a predictor of NT-proBNP (coefficient 0.38, SE 0.12; P=0.0015). Hs-cTnT concentrations were significantly increased in patients with CAD with or without myocardial ischemia (P<0.005), whereas only patients with CAD and ischemia showed significantly higher levels of NT-proBNP (P<0.001). CONCLUSIONS: In patients with stable angina, the presence and extent of coronary atherosclerosis is related with circulating levels of hs-cTnT, also in the absence of ischemia, suggesting an ischemia-independent mechanism of hs-cTnT release. Obstructive CAD causing myocardial ischemia is associated with increased levels of NT-proBNP.


Assuntos
Angina Estável/sangue , Doença da Artéria Coronariana/sangue , Isquemia Miocárdica/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Troponina T/sangue , Angina Estável/diagnóstico , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia sob Estresse , Europa (Continente) , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
13.
J Cardiovasc Magn Reson ; 18: 3, 2016 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-26754743

RESUMO

BACKGROUND: Coronary artery disease (CAD) continues to be one of the top public health burden. Perfusion cardiovascular magnetic resonance (CMR) is generally accepted to detect CAD, while data on its cost effectiveness are scarce. Therefore, the goal of the study was to compare the costs of a CMR-guided strategy vs two invasive strategies in a large CMR registry. METHODS: In 3'647 patients with suspected CAD of the EuroCMR-registry (59 centers/18 countries) costs were calculated for diagnostic examinations (CMR, X-ray coronary angiography (CXA) with/without FFR), revascularizations, and complications during a 1-year follow-up. Patients with ischemia-positive CMR underwent an invasive CXA and revascularization at the discretion of the treating physician (=CMR + CXA-strategy). In the hypothetical invasive arm, costs were calculated for an initial CXA and a FFR in vessels with ≥50% stenoses (=CXA + FFR-strategy) and the same proportion of revascularizations and complications were applied as in the CMR + CXA-strategy. In the CXA-only strategy, costs included those for CXA and for revascularizations of all ≥50% stenoses. To calculate the proportion of patients with ≥50% stenoses, the stenosis-FFR relationship from the literature was used. Costs of the three strategies were determined based on a third payer perspective in 4 healthcare systems. RESULTS: Revascularizations were performed in 6.2%, 4.5%, and 12.9% of all patients, patients with atypical chest pain (n = 1'786), and typical angina (n = 582), respectively; whereas complications (=all-cause death and non-fatal infarction) occurred in 1.3%, 1.1%, and 1.5%, respectively. The CMR + CXA-strategy reduced costs by 14%, 34%, 27%, and 24% in the German, UK, Swiss, and US context, respectively, when compared to the CXA + FFR-strategy; and by 59%, 52%, 61% and 71%, respectively, versus the CXA-only strategy. In patients with typical angina, cost savings by CMR + CXA vs CXA + FFR were minimal in the German (2.3%), intermediate in the US and Swiss (11.6% and 12.8%, respectively), and remained substantial in the UK (18.9%) systems. Sensitivity analyses proved the robustness of results. CONCLUSIONS: A CMR + CXA-strategy for patients with suspected CAD provides substantial cost reduction compared to a hypothetical CXA + FFR-strategy in patients with low to intermediate disease prevalence. However, in the subgroup of patients with typical angina, cost savings were only minimal to moderate.


Assuntos
Cateterismo Cardíaco/economia , Angiografia Coronária/economia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Custos de Cuidados de Saúde , Imageamento por Ressonância Magnética/economia , Imagem de Perfusão do Miocárdio/economia , Revascularização Miocárdica/economia , Tomografia Computadorizada por Raios X/economia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/diagnóstico , Angina Pectoris/economia , Angina Pectoris/terapia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Redução de Custos , Análise Custo-Benefício , Europa (Continente)/epidemiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Econômicos , Imagem de Perfusão do Miocárdio/métodos , Revascularização Miocárdica/efeitos adversos , Seleção de Pacientes , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Adulto Jovem
14.
Eur Heart J Suppl ; 18(Suppl E): E27-E30, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-28533713

RESUMO

Multimodality imaging is the efficient integration of various methods of cardiovascular imaging to improve the ability to diagnose, guide therapy, or predict outcome. This approach implies both the availability of different technologies in a single unit and the presence of dedicated staff with cardiologic and radiologic background and certified competence in more than one imaging technique. Interaction with clinical practice and existence of research programmes and educational activities are pivotal for the success of this model. The aim of this paper is to describe the multimodality cardiac imaging programme recently started at San Donato Hospital.

15.
Circulation ; 130(6): 484-95, 2014 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-25092278

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden death in the young, although not all patients eligible for sudden death prevention with an implantable cardioverter-defibrillator are identified. Contrast-enhanced cardiovascular magnetic resonance with late gadolinium enhancement (LGE) has emerged as an in vivo marker of myocardial fibrosis, although its role in stratifying sudden death risk in subgroups of HCM patients remains incompletely understood. METHODS AND RESULTS: We assessed the relation between LGE and cardiovascular outcomes in 1293 HCM patients referred for cardiovascular magnetic resonance and followed up for a median of 3.3 years. Sudden cardiac death (SCD) events (including appropriate defibrillator interventions) occurred in 37 patients (3%). A continuous relationship was evident between LGE by percent left ventricular mass and SCD event risk in HCM patients (P=0.001). Extent of LGE was associated with an increased risk of SCD events (adjusted hazard ratio, 1.46/10% increase in LGE; P=0.002), even after adjustment for other relevant disease variables. LGE of ≥15% of LV mass demonstrated a 2-fold increase in SCD event risk in those patients otherwise considered to be at lower risk, with an estimated likelihood for SCD events of 6% at 5 years. Performance of the SCD event risk model was enhanced by LGE (net reclassification index, 12.9%; 95% confidence interval, 0.3-38.3). Absence of LGE was associated with lower risk for SCD events (adjusted hazard ratio, 0.39; P=0.02). Extent of LGE also predicted the development of end-stage HCM with systolic dysfunction (adjusted hazard ratio, 1.80/10% increase in LGE; P<0.03). CONCLUSIONS: Extensive LGE measured by quantitative contrast enhanced CMR provides additional information for assessing SCD event risk among HCM patients, particularly patients otherwise judged to be at low risk.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/mortalidade , Meios de Contraste , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Método Simples-Cego , Adulto Jovem
16.
Br J Haematol ; 164(4): 579-85, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24460526

RESUMO

The age at which it is necessary to start Cardiovascular Magnetic Resonance (CMR) T2* screening in thalassaemia major (TM) is still uncertain. To clarify this point, we evaluated the prevalence of myocardial iron overload (MIO), function and fibrosis by CMR in TM patients younger than 10 years. We retrospectively selected 35 TM patients enrolled in the Myocardial Iron Overload in Thalassaemia network. MIO was measured by T2* multislice multiecho technique. Biventricular function parameters were evaluated by cine images. To detect myocardial fibrosis, late gadolinium enhancement images were acquired. Patients' age ranged from 4·2 to 9·7 years. All scans were performed without sedation. Nine patients showed no MIO, 22 patients had heterogeneous MIO with a T2* global value ≥20 ms; two patients had heterogeneous MIO with a T2* global value <20 ms and two patients showed homogeneous MIO. No patient showed myocardial fibrosis. Among the patients with heart T2*<20 ms, the youngest was 6 years old, none showed heart dysfunction and the iron transfused was <35 g in all cases. Cardiac iron loading can occur much earlier than previously described. The first cardiac T2* assessment should be performed as early as feasible without sedation, especially if chelation is started late or if poor compliance is suspected.


Assuntos
Sobrecarga de Ferro/sangue , Miocárdio/metabolismo , Talassemia beta/sangue , Cardiomiopatias/sangue , Cardiomiopatias/metabolismo , Criança , Feminino , Humanos , Sobrecarga de Ferro/diagnóstico , Sobrecarga de Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos , Talassemia beta/metabolismo
17.
Magn Reson Med ; 72(2): 485-91, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24123261

RESUMO

PURPOSE: To determine whether systematic differences were present between myocardial R2* values obtained with two different decay models: truncation and exponential + constant (Exp-C). METHODS: Single-center cohorts were used to compare black and bright blood sequences separately, and a multicenter cohort of mixed bright and black blood studies was used to assess the generalizability. Truncated exponential estimates were calculated with CMRtools, which uses a single region of interest (ROI) method. Exp-C estimates were calculated using a pixelwise approach. RESULTS: No differences could be distinguished based upon whether a white or black blood sequence was examined. The two fitting algorithms yielded similar R2* values, with R-squared values exceeding 0.997 and a coefficient of variation of 3% to 4%. Results using the pixelwise method yielded a small systematic bias (∼3%) that became apparent in patients with severe iron deposition. This disparity disappeared when Exp-C fitting was used on a single ROI, suggesting that the use of pixelwise mapping was responsible for the bias. In the multicenter cohort, the strong agreement between the two fitting approaches was reconfirmed. CONCLUSION: Cardiac R2* values are independent of the signal model used for its calculation over clinically relevant ranges. Clinicians can compare results among centers using these disparate approaches with confidence.


Assuntos
Algoritmos , Artefatos , Cardiopatias/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Talassemia beta/patologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
18.
Magn Reson Med ; 71(6): 2224-30, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23813553

RESUMO

PURPOSE: Realizing the challenges and opportunities of effective transverse relaxation rate (R2 *) mapping at high and ultrahigh fields, this work examines magnetic field strength (B0 ) dependence and segmental artifact distribution of myocardial R2 * at 1.5, 3.0, and 7.0 T. METHODS: Healthy subjects were considered. Three short-axis views of the left ventricle were examined. R2 * was calculated for 16 standard myocardial segments. Global and mid-septum R2 * were determined. For each segment, an artifactual factor was estimated as the deviation of segmental from global R2 * value. RESULTS: The global artifactual factor was significantly enlarged at 7.0 T versus 1.5 T (P = 0.010) but not versus 3.0 T. At 7.0 T, the most severe susceptibility artifacts were detected in the inferior lateral wall. The mid-septum showed minor artifactual factors at 7.0 T, similar to those at 1.5 and 3.0 T. Mean R2 * increased linearly with the field strength, with larger changes for global heart R2 * values. CONCLUSION: At 7.0 T, segmental heart R2 * analysis is challenging due to macroscopic susceptibility artifacts induced by the heart-lung interface and the posterior vein. Myocardial R2 * depends linearly on the magnetic field strength. The increased R2 * sensitivity at 7.0 T might offer means for susceptibility-weighted and oxygenation level-dependent MR imaging of the myocardium.


Assuntos
Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Magnetismo , Masculino
19.
Eur J Nucl Med Mol Imaging ; 41(9): 1692-4, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24819056

RESUMO

PURPOSE: To assess the relationships between myocardial structure and function on cardiac magnetic resonance (CMR) imaging and sympathetic tone on (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy early after myocardial infarction (MI). METHODS: Ten patients underwent (123)I-MIBG and (99m)Tc-tetrofosmin rest cadmium zinc telluride scintigraphy 4 ± 1 days after MI. The segmental left ventricular (LV) relative radiotracer uptake of both (99m)Tc-tetrofosmin and early (123)I-MIBG was calculated. The day after scintigraphy, on CMR imaging, the extent of ischaemia-related oedema and of myocardial fibrosis (late gadolinium enhancement, LGE) was assessed. Accordingly, the extent of oedema and LGE was evaluated for each segment and segmental wall thickening determined. Based on LGE distribution, LV segments were categorized as "infarcted" (56 segments), "adjacent" (66 segments) or "remote" (48 segments). RESULTS: Infarcted segments showed a more depressed systolic wall thickening and greater extent of oedema than adjacent segments (p < 0.001) and remote segments (p < 0.001). Interestingly, while uptake of (99m)Tc-tetrofosmin was significantly depressed only in infarcted segments (p < 0.001 vs. both adjacent and remote segments), uptake of (123)I-MIBG was impaired not only in infarcted segments (p < 0.001 vs. remote) but also in adjacent segments (p = 0.024 vs. remote segments). At the regional level, after correction for (99m)Tc-tetrofosmin and LGE distribution, segmental (123)I-MIBG uptake (p < 0.001) remained an independent predictor of ischaemia-related oedema. CONCLUSION: After acute MI the regional impairment of sympathetic tone extends beyond the area of altered myocardial perfusion and is associated with myocardial oedema.


Assuntos
3-Iodobenzilguanidina , Edema/complicações , Coração/inervação , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Sistema Nervoso Simpático/fisiopatologia , Doença Aguda , Idoso , Cádmio , Feminino , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Cintilografia , Sistema Nervoso Simpático/diagnóstico por imagem , Telúrio , Zinco
20.
J Magn Reson Imaging ; 39(3): 550-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24123545

RESUMO

PURPOSE: To evaluate the efficiency of a novel transit time (Δt) estimation method from cardiovascular magnetic resonance flow curves. MATERIALS AND METHODS: Flow curves were estimated from phase contrast images of 30 patients. Our method (TT-GD: transit time group delay) operates in the frequency domain and models the ascending aortic waveform as an input passing through a discrete-component "filter," producing the observed descending aortic waveform. The GD of the filter represents the average time delay (Δt) across individual frequency bands of the input. This method was compared with two previously described time-domain methods: TT-point using the half-maximum of the curves and TT-wave using cross-correlation. High temporal resolution flow images were studied at multiple downsampling rates to study the impact of differences in temporal resolution. RESULTS: Mean Δts obtained with the three methods were comparable. The TT-GD method was the most robust to reduced temporal resolution. While the TT-GD and the TT-wave produced comparable results for velocity and flow waveforms, the TT-point resulted in significant shorter Δts when calculated from velocity waveforms (difference: 1.8±2.7 msec; coefficient of variability: 8.7%). The TT-GD method was the most reproducible, with an intraobserver variability of 3.4% and an interobserver variability of 3.7%. CONCLUSION: Compared to the traditional TT-point and TT-wave methods, the TT-GD approach was more robust to the choice of temporal resolution, waveform type, and observer.


Assuntos
Algoritmos , Aorta Torácica , Imagem Cinética por Ressonância Magnética/métodos , Análise de Onda de Pulso , Fluxo Sanguíneo Regional/fisiologia , Adolescente , Adulto , Análise de Variância , Anemia Falciforme/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Fluxo Pulsátil , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem , Talassemia beta/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA