Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(3): 835-844, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36748247

RESUMO

AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fotopletismografia/métodos , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , Algoritmos
2.
N Engl J Med ; 380(16): 1499-1508, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-30883054

RESUMO

BACKGROUND: Patients with recent-onset atrial fibrillation commonly undergo immediate restoration of sinus rhythm by pharmacologic or electrical cardioversion. However, whether immediate restoration of sinus rhythm is necessary is not known, since atrial fibrillation often terminates spontaneously. METHODS: In a multicenter, randomized, open-label, noninferiority trial, we randomly assigned patients with hemodynamically stable, recent-onset (<36 hours), symptomatic atrial fibrillation in the emergency department to be treated with a wait-and-see approach (delayed-cardioversion group) or early cardioversion. The wait-and-see approach involved initial treatment with rate-control medication only and delayed cardioversion if the atrial fibrillation did not resolve within 48 hours. The primary end point was the presence of sinus rhythm at 4 weeks. Noninferiority would be shown if the lower limit of the 95% confidence interval for the between-group difference in the primary end point in percentage points was more than -10. RESULTS: The presence of sinus rhythm at 4 weeks occurred in 193 of 212 patients (91%) in the delayed-cardioversion group and in 202 of 215 (94%) in the early-cardioversion group (between-group difference, -2.9 percentage points; 95% confidence interval [CI], -8.2 to 2.2; P = 0.005 for noninferiority). In the delayed-cardioversion group, conversion to sinus rhythm within 48 hours occurred spontaneously in 150 of 218 patients (69%) and after delayed cardioversion in 61 patients (28%). In the early-cardioversion group, conversion to sinus rhythm occurred spontaneously before the initiation of cardioversion in 36 of 219 patients (16%) and after cardioversion in 171 patients (78%). Among the patients who completed remote monitoring during 4 weeks of follow-up, a recurrence of atrial fibrillation occurred in 49 of 164 patients (30%) in the delayed-cardioversion group and in 50 of 171 (29%) in the early-cardioversion group. Within 4 weeks after randomization, cardiovascular complications occurred in 10 patients and 8 patients, respectively. CONCLUSIONS: In patients presenting to the emergency department with recent-onset, symptomatic atrial fibrillation, a wait-and-see approach was noninferior to early cardioversion in achieving a return to sinus rhythm at 4 weeks. (Funded by the Netherlands Organization for Health Research and Development and others; RACE 7 ACWAS ClinicalTrials.gov number, NCT02248753.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Tempo para o Tratamento , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Digoxina/uso terapêutico , Cardioversão Elétrica/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35040534

RESUMO

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/cirurgia , Resultado do Tratamento
4.
Europace ; 24(3): 384-389, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34414430

RESUMO

AIMS: We hypothesize that in patients with paroxysmal atrial fibrillation (AF), verapamil is associated with lower AF progression compared to beta blockers or no rate control. METHODS AND RESULTS: In this pre-specified post hoc analysis of the RACE 4 randomized trial, the effect of rate control medication on AF progression in paroxysmal AF was analysed. Patients using Vaughan-Williams Class I or III antiarrhythmic drugs were excluded. The primary outcome was a composite of first electrical cardioversion (ECV), chemical cardioversion (CCV), or atrial ablation. Event rates are displayed using Kaplan-Meier curves and multivariable Cox regression analyses are used to adjust for baseline differences. Out of 666 patients with paroxysmal AF, 47 used verapamil, 383 used beta blockers, and 236 did not use rate control drugs. The verapamil group was significantly younger than the beta blocker group and contained more men than the no rate control group. Over a mean follow-up of 37 months, the primary outcome occurred in 17% in the verapamil group, 33% in the beta blocker group, and 33% in the no rate control group (P = 0.038). After adjusting for baseline characteristics, patients using verapamil have a significantly lower chance of receiving ECV, CCV, or atrial ablation compared to patients using beta blockers [hazard ratio (HR) 0.40, 95% confidence interval (CI) 0.19-0.83] and no rate control (HR 0.64, 95% CI 0.44-0.93). CONCLUSION: In patients with newly diagnosed paroxysmal AF, verapamil was associated with less AF progression, as compared to beta blockers and no rate control.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Humanos , Masculino , Resultado do Tratamento
5.
Europace ; 24(2): 193-201, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-34329401

RESUMO

AIMS: The clinical risk profile of atrial fibrillation (AF) patients is different in men and women. Our aim was to identify sex differences in blood biomarkers in patients with paroxysmal AF. METHODS AND RESULTS: Sex differences in 92 blood biomarkers were measured in 364 patients included in our discovery cohort, the identification of a risk profile to guide atrial fibrillation therapy (AF-RISK) study, assessed by multivariable logistic regression and enrichment pathway analysis. Findings were subsequently confirmed in 213 patients included in our validation cohort, the Reappraisal of Atrial Fibrillation: Interaction between HyperCoagulability, Electrical remodelling, and Vascular Destabilisation in the Progression of AF (RACE V) study. In the discovery cohort, mean age was 59 ± 12 years, 41% were women. CHA2DS2-VASc-score was 1.6 ± 1.4. A total of 46% had hypertension, 10% diabetes, and 50% had heart failure, predominantly with preserved ejection fraction (47%). In women, activated leucocyte cell adhesion molecule (ALCAM) and fatty acid binding protein-4 (FABP-4) were higher. In men, matrix metalloproteinase-3 (MMP-3), C-C motif chemokine-16 (CCL-16), and myoglobin were higher. In the validation cohort, four out of five biomarkers could be confirmed: levels of ALCAM (P = 1.73 × 10-4) and FABP-4 (P = 2.46 × 10-7) and adhesion biological pathways [false discovery rate (FDR) = 1.23 × 10-8] were higher in women. In men, levels of MMP-3 (P = 4.31 × 10-8) and myoglobin (P = 2.10 × 10-4) and markers for extracellular matrix degradation biological pathways (FDR = 3.59 × 10-9) were higher. CONCLUSION: In women with paroxysmal AF, inflammatory biomarkers were more often higher, while in men with paroxysmal AF, biomarkers for vascular remodelling were higher. Our data support the clinical notion that pathophysiological mechanisms in women and men with AF may differ. TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT01510210 for AF-RISK; Clinicaltrials.gov NCT02726698 for RACE V.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Idoso , Biomarcadores , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco
6.
Europace ; 24(4): 565-575, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34718525

RESUMO

AIMS: In atrial fibrillation (AF) patients, untreated sleep-disordered breathing (SDB) is associated with lower success rates of rhythm control strategies and as such structured SDB testing is recommended. Herein, we describe the implementation of a virtual SDB management pathway in an AF outpatient clinic and examine the utility and feasibility of this new approach. METHODS AND RESULTS: Prospectively, consecutive AF patients accepted for AF catheter ablation procedures without previous diagnosis of SDB were digitally referred to a virtual SDB management pathway and instructed to use WatchPAT-ONE (ITAMAR) for one night. Results were automatically transferred to a virtual sleep laboratory, upon which a teleconsultation with a sleep physician was planned. Patient experience was measured using surveys. SDB testing was performed in 119 consecutive patients scheduled for AF catheter ablation procedures. The median time from digital referral to finalization of the sleep study report was 18 [11-24] days. In total, 65 patients (55%) were diagnosed with moderate-to-severe SDB. Patients with SDB were prescribed more cardiovascular drugs and had higher body mass indices (BMI, 29 ± 3.3 vs. 27 ± 4.4kg/m2, P < 0.01). Patients agreed that WatchPAT-ONE was easy to use (91%) and recommended future use of this virtual pathway in AF outpatient clinics (86%). Based on this remote SDB testing, SDB treatment was recommended in the majority of patients. CONCLUSION: This novel virtual AF management pathway allowed remote SDB testing in AF outpatient clinics with a short time to diagnosis and high patient satisfaction. Structured SDB testing results in a high detection of previously unknown SDB in AF patients scheduled for AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Síndromes da Apneia do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Polissonografia , Sono , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia
7.
J Card Surg ; 37(12): 4630-4638, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36349741

RESUMO

BACKGROUND: Hybrid ablation (HA) of atrial fibrillation (AF) combines minimally invasive thoracoscopic epicardial ablation with transvenous endocardial electrophysiologic validation and touch-up of incomplete epicardial lesions if needed. While studies have reported on a bilateral thoracoscopic HA approach, data on a unilateral left-sided approach are scarce. AIM: To evaluate the efficacy and safety of a unilateral left-sided thoracoscopic approach. METHODS: Retrospective analysis of a prospectively gathered cohort of all consecutive patients undergoing a unilateral left-sided HA for AF between 2015 and 2018 in the Maastricht University Medical Centre. RESULTS: One-hundred nineteen patients were analyzed (mean age 64 ± 8, 28% female, mean body mass index 28 ± 4 kg/m2 , median CHA2 DS2 -VASc Score 2 [1-3], [longstanding]-persistent AF 71%, previous catheter ablation 44%). In all patients, a unilateral left-sided HA consisting of pulmonary vein (PV) isolation, posterior left atrial (LA) wall isolation, and LA appendage exclusion was attempted. Epicardial (n = 59) and/or endocardial validation (n = 81) was performed and endocardial touch-up was performed in 33 patients. Major peri-operative complications occurred in 5% of all patients. After 12 and 24 months, the probability of being free from supraventricular tachyarrhythmia recurrence was 80% [73-87] and 67% [58-76], respectively, when allowing antiarrhythmic drugs. CONCLUSION: Unilateral left-sided hybrid AF ablation is an efficacious and safe approach to treat patients with paroxysmal and (longstanding) persistent AF. Future studies should compare a unilateral with a bilateral approach to determine whether a left-sided approach is as efficacious as a bilateral approach and allows for less complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Toracoscopia , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
8.
Europace ; 23(23 Suppl 2): ii23-ii27, 2021 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-33837757

RESUMO

Treatment of symptomatic atrial fibrillation has seen important changes in the past decades. Advancements have especially been made in the field of non-pharmacological treatment of this disease. Patients in whom a rhythm control strategy is chosen the place of catheter ablation has become more frontline therapy in the past years. The procedure itself has also seen changes in technologies that can be used, either using point-by-point radiofrequency or one of the single-shot techniques. One of the major limitations that remain is that re-do procedures are often necessary due to incomplete pulmonary vein isolation and/or atrial fibrillation being initiated by other mechanisms than pulmonary vein triggers. Therefore, there is further need for developing ablation tools that reproducibly isolate the pulmonary vein transmurally. Furthermore, addressing the underlying conditions before and after catheter ablation has been shown to be of great importance. In this review, we will give an overview of the evolution of catheter ablation, highlight the latest technologies and their future endeavours, and lifestyle modifications are being discussed as part of the catheter ablation strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
9.
Europace ; 23(23 Suppl 2): ii28-ii33, 2021 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-33837755

RESUMO

Despite many years of research, the different aspects of the mechanism of atrial fibrillation (AF) are still incompletely understood. And although the latest guidelines recommend catheter ablation with pulmonary vein isolation as a rhythm control strategy, long-term results in persistent and long-standing persistent AF are suboptimal. Historically, a mechanistic-based patient-tailored approach for the treatment of AF was impossible because of the lack real-time mapping techniques and advanced ablation tools. Therefore, surgeons created lesion sets based upon the anatomy of both atria and the safety of the incisions made by the knife. These complex open-heart procedures had to be performed through a sternotomy on the arrested heart and where therefore not generally adopted. The use of controlled energy sources such as cryothermy and radiofrequency where the first step to make the creation of these lesions less complex. With the development and improvement of electrophysiology techniques and catheters, this invasive and solely anatomical approach could again be partially redesigned. Now less invasive, it prepared the way for collaboration between electrophysiologists working on the endocardial side of the heart and cardiac surgeons providing epicardial access. The introduction of video-assisted technology and hybrid procedures has further increased the possibilities of new successful therapies. Now more than 40 years since the beginning of this exciting maze of AF procedures and still working towards a less aggressive and more comprehensive approach we give an overview of the history of the different minimally invasive surgical solutions and of the hybrid approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Endocárdio/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
10.
Eur Heart J ; 41(5): 634-641, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31544925

RESUMO

BACKGROUND: Nurse-led integrated care is expected to improve outcome of patients with atrial fibrillation compared with usual-care provided by a medical specialist. METHODS AND RESULTS: We randomized 1375 patients with atrial fibrillation (64 ± 10 years, 44% women, 57% had CHA2DS2-VASc ≥ 2) to receive nurse-led care or usual-care. Nurse-led care was provided by specialized nurses using a decision-support tool, in consultation with the cardiologist. The primary endpoint was a composite of cardiovascular death and cardiovascular hospital admissions. Of 671 nurse-led care patients, 543 (81%) received anticoagulation in full accordance with the guidelines against 559 of 683 (82%) usual-care patients. The cumulative adherence to guidelines-based recommendations was 61% under nurse-led care and 26% under usual-care. Over 37 months of follow-up, the primary endpoint occurred in 164 of 671 patients (9.7% per year) under nurse-led care and in 192 of 683 patients (11.6% per year) under usual-care [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.69 to 1.04, P = 0.12]. There were 124 vs. 161 hospitalizations for arrhythmia events (7.0% and 9.4% per year), and 14 vs. 22 for heart failure (0.7% and 1.1% per year), respectively. Results were not consistent in a pre-specified subgroup analysis by centre experience, with a HR of 0.52 (95% CI 0.37-to 0.71) in four experienced centres and of 1.24 (95% CI 0.94-1.63) in four less experienced centres (P for interaction <0.001). CONCLUSION: Our trial failed to show that nurse-led care was superior to usual-care. The data suggest that nurse-led care by an experienced team could be clinically beneficial (ClinicalTrials.gov NCT01740037). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov (NCT01740037).


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Acidente Vascular Cerebral , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Papel do Profissional de Enfermagem , Modelos de Riscos Proporcionais
11.
Europace ; 22(8): 1162-1172, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32642768

RESUMO

AIMS: Atrial fibrillation (AF) often starts as a paroxysmal self-terminating arrhythmia. Limited information is available on AF patterns and episode duration of paroxysmal AF. In paroxysmal AF patients, we longitudinally studied the temporal AF patterns, the association with clinical characteristics, and prevalence of AF progression. METHODS AND RESULTS: In this interim analysis of the Reappraisal of AF: Interaction Between HyperCoagulability, Electrical Remodelling, and Vascular Destabilisation in the Progression of AF (RACE V) registry, 202 patients with paroxysmal AF were followed with continuous rhythm monitoring (implantable loop recorder or pacemaker) for 6 months. Mean age was 64 ± 9 years, 42% were women. Atrial fibrillation history was 2.1 (0.5-4.4) years, CHA2DS2-VASc 1.9 ± 1.3, 101 (50%) had hypertension, 69 (34%) heart failure. One-third had no AF during follow-up. Patients with long episodes (>12 hours) were often men with more comorbidities (heart failure, coronary artery disease, higher left ventricular mass). Patients with higher AF burden (>2.5%) were older with more comorbidities (worse renal function, higher calcium score, thicker intima media thickness). In 179 (89%) patients, 1-year rhythm follow-up was available. On a quarterly basis, average daily AF burden increased from 3.2% to 3.8%, 5.2%, and 6.1%. Compared to the first 6 months, 111 (62%) patients remained stable during the second 6 months, 39 (22%) showed progression to longer AF episodes, 8 (3%) developed persistent AF, and 29 (16%) patients showed AF regression. CONCLUSIONS: In paroxysmal AF, temporal patterns differ suggesting that paroxysmal AF is not one entity. Atrial fibrillation burden is low and determined by number of comorbidities. Atrial fibrillation progression occurred in a substantial number. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier NCT02726698.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Marca-Passo Artificial , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Espessura Intima-Media Carotídea , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
12.
Pacing Clin Electrophysiol ; 42(5): 508-514, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30756393

RESUMO

BACKGROUND: The second-generation cryoballoon significantly improves outcome of pulmonary vein isolation (PVI) but may cause more complications than the first generation. Currently, no consensus regarding optimal cryoballoon application time exists. The 123-study aimed to assess the minimal cryoballoon application duration necessary to achieve PVI (primary endpoint) and the effect of application duration on prevention of phrenic nerve injury (PNI). METHODS: Patients <75 years of age with paroxysmal atrial fibrillation, normal PV anatomy, and left atrial size <40 cc/m² or <50 mm were randomized to two applications of different duration: "short," "medium," or "long." A total of 222 patients were enrolled, 74 per group. RESULTS: Duration per application was 105 (101-108), 164 (160-168), and 224 (219-226) s and isolation was achieved in 79, 89, and 90% (P < 0.001) of the PVs after two applications in groups short, medium, and long, respectively. Only for the left PVs, the success rate of the short group was significantly less compared to the medium- and long-duration groups (P < 0.001). PNI during the procedure occurred in 19 PVs (6.5%) in the medium and in 20 PVs (6.8%) in the long duration groups compared to only five PVs (1.7%) in the short duration group (P < 0.001). CONCLUSIONS: Short cryoballoon ablation application times, less than 2 min, did affect the success for the left PVs but not for the right PVs and resulted in less PNI. A PV tailored approach with shorter application times for the right PVs might be advocated.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
Europace ; 20(6): 929-934, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016989

RESUMO

Aims: Progression of atrial fibrillation (AF) from paroxysmal to persistent forms is an active field of research. The influence of AF progression on health related quality of life (HRQoL) is currently unknown. We aimed to assess the influence of AF progression on HRQoL, and whether this association is mediated through symptoms, treatment, and major adverse events. Methods and results: In the Euro Heart Survey, 967 patients were included with paroxysmal AF who filled out EuroQoL-5D at baseline and at 1 year follow-up. Those who progressed (n = 132, 13.6%) developed more problems during follow-up than those who did not, on all EuroQoL-5D domains (increase in problems on mobility 20.5% vs. 11.4%; self-care 12.9% vs. 6.2%; usual activities 23.5% vs. 14.0%; pain/discomfort 20.5% vs. 13.7%; and anxiety/depression 22.7% vs. 15.7%; all P < 0.05), leading to a decrease in utility [baseline 0.744 ± 0.26, follow-up 0.674 ± 0.36; difference -0.07 (95% CI [-0.126,-0.013], P = 0.02)]. Multivariate analysis showed that the effect of progression on utility is mediated by a large effect of adverse events [stroke (-0.27 (95% CI [-0.43,-0.11]); P = 0.001], heart failure [-0.12 (95% CI [-0.20,-0.05]); P = 0.001], malignancy (-0.31 (95% CI [-0.56,-0.05]); P = 0.02] or implantation of an implantable cardiac defibrillator [-0.12 (95% CI [-0.23,-0.02]); P = 0.03)], as well as symptomatic AF [-0.04 (95% CI [-0.08,-0.01]); P = 0.008]. Conclusion: AF progression is associated with a decrease in HRQoL. However, multivariate analysis revealed that AF progression itself does not have a negative effect on HRQoL, but that this effect can be attributed to a minor effect of the associated symptoms and a major effect of associated adverse events.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Qualidade de Vida , Acidente Vascular Cerebral , Fatores Etários , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/psicologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis/psicologia , Desfibriladores Implantáveis/estatística & dados numéricos , Progressão da Doença , Europa (Continente)/epidemiologia , Feminino , Inquéritos Epidemiológicos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/psicologia , Humanos , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/psicologia , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/psicologia
14.
Pacing Clin Electrophysiol ; 41(10): 1336-1340, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30080928

RESUMO

BACKGROUND: Atrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. OBJECTIVES: To evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. METHODS: We conducted a retrospective observational study of 229 patients (27.9% female, age 69 ± 10 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow-up (FU) after eECV were collected. CIED-related complications and adverse events during and after eECV were recorded. RESULTS: No significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 Ω vs 462 Ω, P < 0.001 and 536 Ω vs 514 Ω, P < 0.001, respectively). The RV impedance did not recover to the baseline value (538 Ω vs 527 Ω, P  =  0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED-related complications or adverse events were documented following eECV. CONCLUSION: eECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Marca-Passo Artificial , Segurança do Paciente , Idoso , Feminino , Humanos , Masculino , Países Baixos , Estudos Retrospectivos
16.
Pacing Clin Electrophysiol ; 39(3): 307-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26548562

RESUMO

A 53-year-old female patient with hypertrophic obstructive cardiomyopathy (HOCM) was admitted for alcohol septal ablation (ASA). A subcutaneous internal cardioverter defibrillator (S-ICD) was implanted for primary prevention. After ASA, the patient developed a right bundle branch block, and the S-ICD delivered a total of five inappropriate shocks due to T-wave oversensing (TWOS). TWOS is a relatively frequent cause of inappropriate shocks in S-ICD patients. After invasive treatment for HOCM, there is a risk of developing intraventricular conduction delay and subsequent changes in QRS and T-wave morphology. This should be taken into consideration when ICD indication is evaluated in HOCM patients.


Assuntos
Técnicas de Ablação/métodos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis/efeitos adversos , Traumatismos por Eletricidade/etiologia , Etanol/uso terapêutico , Cardiomiopatia Hipertrófica/diagnóstico , Terapia Combinada/efeitos adversos , Terapia Combinada/métodos , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/prevenção & controle , Feminino , Septos Cardíacos/cirurgia , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Heart Rhythm ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971417

RESUMO

BACKGROUND: Idiopathic epicardial premature ventricular contractions (PVCs) originating from the left ventricular summit are difficult to eliminate. OBJECTIVE: To describe feasibility and procedural safety of focal monopolar biphasic pulsed field ablation (F-PFA) from within the great cardiac vein (GCV) for the treatment of idiopathic epicardial PVCs. METHODS: In 4 pigs, F-PFA (CENTAURI, Cardiofocus) was applied from within the GCV followed by macroscopic gross analysis. In 4 patients with previously failed radiofrequency ablation, electroanatomic mapping was used to guide F-PFA from within the GCV and the ventricular outflow tracts. Coronary angiography and optical coherence tomography (OCT) were performed in 2 patients. RESULTS: In pigs, F-PFA from within the GCV (5mm away from the coronary arteries) resulted in myocardial lesions with a maximal depth of 4mm which was associated with non-obstructive transient coronary spasms. In patients, sequential delivery of F-PFA in the ventricular outflow tracts and from within the GCV eliminated the PVCs. During F-PFA delivery from within the GCV with prophylactic nitroglycerin application, coronary angiography showed no coronary spasm when F-PFA was delivered >5mm away from the coronary artery and a transient coronary spasm without changes in a subsequent OCT, when F-PFA was delivered directly on the coronary artery. Intracardiac echo and computer tomography integration was used to monitor F-PFA delivery from within the GCV. There were no immediate or short-term complications. CONCLUSION: Sequential mapping-guided F-PFA from endocardial ventricular outflow tracts and from within the GCV is feasible with a favourable procedural safety profile for the treatment of epicardial PVC.

18.
Artigo em Inglês | MEDLINE | ID: mdl-39001763

RESUMO

BACKGROUND: Dark-blood late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) has better correlation with bipolar voltage (BiV) to define ablation scar in the left atrium (LA) compared to conventional bright-blood LGE CMR. OBJECTIVES: This study sought to determine the optimal signal intensity threshold of dark-blood LGE CMR to identify LA ablation scar. METHODS: In 54 patients scheduled for atrial fibrillation ablation, image intensity ratios (IIRs) were derived from preprocedural dark-blood LGE CMR. In 26 patients without previous ablation, the upper limit of normal was derived from the 95th and 98th percentiles of pooled IIR values. In 28 patients with previous atrial fibrillation ablation, BiV was compared with the corresponding IIR. Receiver-operating characteristics analyses were employed to determine the optimal IIR threshold (ie, the point with the smallest distance to the upper left corner of the receiver-operating characteristics) for LA ablation scar (BiV ≤0.15 mV). RESULTS: Upper limit of normal corresponded to IIR values 1.16 and 1.21, yielding low sensitivities of 0.32 and 0.09 to detect LA ablation scar. Receiver-operating characteristics analysis of IIR and BiV comparison achieved a median area under the curve of 0.77. Median optimal IIR threshold for LA ablation scar was 1.09, with an average sensitivity of 0.73, specificity of 0.75, and accuracy of 0.71. Median IIR thresholds of 1.00 and 1.10 corresponded to 80% sensitivity and 80% specificity, respectively. There was considerable interpatient variability: optimal IIR thresholds per patient ranged from 1.01 to 1.22. CONCLUSIONS: The optimal IIR threshold to identify LA ablation scar by dark-blood LGE CMR is 1.09. Because of interpatient variability, the investigators recommend using a lower (1.00) and upper (1.10) threshold to prevent over- or underestimation of ablation scar.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38569919

RESUMO

OBJECTIVES: Thoracoscopic hybrid ablation is an effective and safe rhythm control strategy for patients with complex forms of atrial fibrillation. Its effect on left atrial function has not yet been studied. METHODS: In a retrospective single-centre analysis of patients undergoing thoracoscopic hybrid ablation, the left atrial emptying fraction was calculated using the biplane modified Simpson method in the apical 2- and 4-chamber views on transthoracic echocardiography. Left atrial strain (reservoir, conduction and contractility) was quantified using dedicated software. RESULTS: Sixty-seven patients were included (mean age 64 years, long-standing persistent atrial fibrillation in 69%, median atrial fibrillation history duration 64 months). At baseline, left atrial function and contractility were poor. The reservoir and contractile strain improved postprocedure compared to baseline [15 (standard deviation (SD): 8) and 17 (SD: 6); P = 0.013; 3 (SD: 5) and 4 (SD: 4), P = 0.008], whereas the left atrial volume indexed to the body surface area was reduced [51 ml/m2 (SD: 14) and 47 ml/m2 (SD: 18), P = 0.0024]. In patients with preoperative (long-standing) persistent atrial fibrillation and in patients with rhythm restoration, improvements in the emptying fraction, (reservoir and contractile) strain and the left ventricular ejection fraction were observed, whereas the left atrial volume decreased (P < 0.05). CONCLUSIONS: In this cohort of patients with severely diseased left atria, improvement in left atrial contractility and in the emptying fraction after thoracoscopic hybrid ablation for atrial fibrillation in patients with persistent atrial fibrillation is mainly due to rhythm restoration. Interestingly, the procedure itself also results in improved left atrial reservoir strain and reversed left atrial remodelling by reducing left atrial volume.

20.
Ann Cardiothorac Surg ; 13(1): 54-70, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38380145

RESUMO

In this state-of-the art review on hybrid atrial fibrillation (AF) ablation, we briefly focus on the pathophysiology of AF, the rationale for the hybrid approach, its technical aspects and the efficacy and safety outcomes after hybrid AF ablation, both from meta-analyses and randomized control trial data. Also, we performed a systematic search to provide a provisional overview of real-world hybrid AF ablation efficacy and safety outcomes. Furthermore, we give an insight into the 'Maastricht approach', an approach that allows us to tailor the ablation procedure to the individual patient. Finally, we reflect on future perspectives with the objective to continue improving our thoracoscopic hybrid AF ablation approach. Based on the review of the available literature, we believe it is fair to state that thoracoscopic hybrid AF ablation is a valid alternative to catheter ablation for the treatment of patients with more persistent forms of AF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA