Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 83(2): 695-711, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31483521

RESUMO

PURPOSE: Local specific absorption rate (SAR) cannot be measured and is usually evaluated by offline numerical simulations using generic body models that of course will differ from the patient's anatomy. An additional safety margin is needed to include this intersubject variability. In this work, we present a deep learning-based method for image-based subject-specific local SAR assessment. We propose to train a convolutional neural network to learn a "surrogate SAR model" to map the relation between subject-specific B1+ maps and the corresponding local SAR. METHOD: Our database of 23 subject-specific models with an 8-transmit channel body array for prostate imaging at 7 T was used to build 5750 training samples. These synthetic complex B1+ maps and local SAR distributions were used to train a conditional generative adversarial network. Extra penalization for local SAR underestimation errors was included in the loss function. In silico and in vivo validation were performed. RESULTS: In silico cross-validation shows a good qualitative and quantitative match between predicted and ground-truth local SAR distributions. The peak local SAR estimation error distribution shows a mean overestimation error of 15% with 13% probability of underestimation. The higher accuracy of the proposed method allows the use of less conservative safety factors compared with standard procedures. In vivo validation shows that the method is applicable with realistic measurement data with impressively good qualitative and quantitative agreement to simulations. CONCLUSION: The proposed deep learning method allows online image-based subject-specific local SAR assessment. It greatly reduces the uncertainty in current state-of-the-art SAR assessment methods, reducing the time in the examination protocol by almost 25%.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Simulação por Computador , Bases de Dados Factuais , Voluntários Saudáveis , Humanos , Masculino , Modelos Estatísticos , Redes Neurais de Computação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
3.
NMR Biomed ; 32(1): e4015, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30376201

RESUMO

The differentiation grade of cervical cancer is histologically assessed by examining biopsies or surgical specimens. MRS is a highly sensitive technique that images tissue metabolism and can be used to increase the specificity of tissue characterization in a non-invasive manner. We aim to explore the feasibility of using in vivo 1 H-MRS at 7 T in women with cervical cancer to study tissue fatty acid composition. 10 women with histologically proven Stage IB1-IIB cervical cancer were scanned with a whole-body 7 T MR system with a multi-transmit system and an internal receive only monopole antenna. A STEAM sequence was used to obtain 1 H-MRS data. Fatty acid resonances were fitted with Lorentzian curves and the 2.1 ppm/1.3 ppm ratios were calculated. 1 H-MRS data showed fatty acid signals resonating at 2.1 ppm, 1.9 ppm, 1.5 ppm, 1.3 ppm and 0.9 ppm. Mean 2.1/1.3 ppm ratios were 0.019 ± 0.01, 0.021 ± 0.006, 0.12 ± 0.089 and 0.39 ± 0.27 for normal, Grade I, Grade II and Grade III groups respectively. Poorly differentiated tumor tissue (Grade III) showed elevated fatty acid ratios when compared with the well differentiated tumor (Grade I) or normal tissue. 1 H-MRS in cervical cancer at 7 T is feasible and individual fatty acid signals were detected. In addition, poorly differentiated tumors show more fatty acid unsaturation. The 2.1 ppm/1.3 ppm ratio has potential for tumor characterization in a non-invasive manner for uterine cervical cancer.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Ácidos Graxos/metabolismo , Feminino , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias do Colo do Útero/patologia
4.
Magn Reson Med ; 78(6): 2449-2459, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28164362

RESUMO

PURPOSE: We introduce a new MR-based method to determine the transfer function (TF) for radiofrequency (RF) safety assessment of active implantable medical devices. Transfer functions are implant-specific measures that relate the incident tangential electric field on an (elongated) implant to a scattered electric field at its tip. The proposed method allows for TF determination with a high spatial resolution in relatively fast measurements without requiring dedicated bench setups from MRI images. THEORY AND METHODS: The principle of reciprocity is used in conjunction with the potential to measure currents with MRI to determine TF. Low-flip angle 3D dual gradient echo MRI data are acquired with an implant as transceive antenna, which requires minimal hardware adaptations. The implant-specific TF is determined from the acquired MRI data, with two different postprocessing methods for comparison. RESULTS: TFs of linear and helical implants can be determined accurately (with a Pearson correlation coefficient R ≥ 0.7 between measurements and simulations, and a difference in field at the tip ΔEtip ≤ 19%) from relatively quick (t < 20 minutes) MRI acquisitions with (several) millimeter spatial resolution. CONCLUSION: Transfer function determination with MRI for RF safety assessment of implantable medical devices is possible. The proposed MR-based method allows for TF determination in more realistic exposure scenarios and solid media. Magn Reson Med 78:2449-2459, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Próteses e Implantes , Animais , Gráficos por Computador , Simulação por Computador , Estimulação Encefálica Profunda , Campos Eletromagnéticos , Radiação Eletromagnética , Humanos , Campos Magnéticos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Razão Sinal-Ruído
5.
Magn Reson Med ; 77(1): 221-228, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26762855

RESUMO

PURPOSE: Development of a passive respiratory motion sensor based on the noise variance of the receive coil array. METHODS: Respiratory motion alters the body resistance. The noise variance of an RF coil depends on the body resistance and, thus, is also modulated by respiration. For the noise variance monitoring, the noise samples were acquired without and with MR signal excitation on clinical 1.5/3 T MR scanners. The performance of the noise sensor was compared with the respiratory bellow and with the diaphragm displacement visible on MR images. Several breathing patterns were tested. RESULTS: The noise variance demonstrated a periodic, temporal modulation that was synchronized with the respiratory bellow signal. The modulation depth of the noise variance resulting from the respiration varied between the channels of the array and depended on the channel's location with respect to the body. The noise sensor combined with MR acquisition was able to detect the respiratory motion for every k-space read-out line. CONCLUSION: Within clinical MR systems, the respiratory motion can be detected by the noise in receive array. The noise sensor does not require careful positioning unlike the bellow, any additional hardware, and/or MR acquisition. Magn Reson Med 77:221-228, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Respiração , Processamento de Sinais Assistido por Computador , Algoritmos , Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Humanos , Ondas de Rádio , Razão Sinal-Ruído
6.
NMR Biomed ; 30(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28574604

RESUMO

The aim of this study was to investigate the signal-to-noise ratio (SNR) gain in early-stage cervical cancer at ultrahigh-field MRI (e.g. 7 T) using a combination of multiple external antennas and a single endorectal antenna. In particular, we used an endorectal monopole antenna to increase the SNR in cervical magnetic resonance imaging (MRI). This should allow high-resolution, T2 -weighted imaging and magnetic resonance spectroscopy (MRS) for metabolic staging, which could facilitate the local tumor status assessment. In a prospective feasibility study, five healthy female volunteers and six patients with histologically proven stage IB1-IIB cervical cancer were scanned at 7 T. We used seven external fractionated dipole antennas for transmit-receive (transceive) and an endorectally placed monopole antenna for reception only. A region of interest, containing both normal cervix and tumor tissue, was selected for the SNR measurement. Separated signal and noise measurements were obtained in the region of the cervix for each element and in the near field of the monopole antenna (radius < 30 mm) to calculate the SNR gain of the endorectal antenna in each patient. We obtained high-resolution, T2 -weighted images with a voxel size of 0.7 × 0.8 × 3.0 mm3 . In four cases with optimal placement of the endorectal antenna (verified on the T2 -weighted images), a mean gain of 2.2 in SNR was obtained at the overall cervix and tumor tissue area. Within a radius of 30 mm from the monopole antenna, a mean SNR gain of 3.7 was achieved in the four optimal cases. Overlap between the two different regions of the SNR calculations was around 24%. We have demonstrated that the use of an endorectal monopole antenna substantially increases the SNR of 7-T MRI at the cervical anatomy. Combined with the intrinsically high SNR of ultrahigh-field MRI, this gain may be employed to obtain metabolic information using MRS and to enhance spatial resolutions to assess tumor invasion.


Assuntos
Imageamento por Ressonância Magnética/métodos , Reto/diagnóstico por imagem , Razão Sinal-Ruído , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Adulto , Idoso , Feminino , Humanos , Estadiamento de Neoplasias
7.
NMR Biomed ; 29(9): 1122-30, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26278544

RESUMO

Although the potential of dipole antennas for ultrahigh-field (UHF) MRI is largely recognized, they are still relatively unknown to the larger part of the MRI community. This article intends to provide electromagnetic insight into the general operating principles of dipole antennas by numerical simulations. The major part focuses on a comparison study of dipole antennas and loop coils at frequencies of 128, 298 and 400 MHz. This study shows that dipole antennas are only efficient radiofrequency (RF) coils in the presence of a dielectric and/or conducting load. In addition, the conservative electric fields (E-fields) at the ends of a dipole are negligible in comparison with the induced E-fields in the center. Like loop coils, long dipole antennas perform better than short dipoles for deeply located imaging targets and vice versa. When the optimal element is chosen for each depth, loop coils have higher B1 (+) efficiency for shallow depths, whereas dipole antennas have higher B1 (+) efficiency for large depths. The cross-over point depth decreases with increasing frequency: 11.6, 6.2 and 5.0 cm for 128, 298 and 400 MHz, respectively. For single elements, loop coils demonstrate a better B1 (+) /√SARmax ratio for any target depth and any frequency. However, one example study shows that, in an array setup with loop coil overlap for decoupling, this relationship is not straightforward. The overlapping loop coils may generate increased specific absorption rate (SAR) levels under the overlapping parts of the loops, depending on the drive phase settings. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Modelos Teóricos , Transdutores , Imagem Corporal Total/instrumentação , Animais , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Campos Magnéticos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
NMR Biomed ; 29(9): 1295-304, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-25916399

RESUMO

Thus far, blood flow velocity measurements with MRI have only been feasible in large cerebral blood vessels. High-field-strength MRI may now permit velocity measurements in much smaller arteries. The aim of this proof of principle study was to measure the blood flow velocity and pulsatility of cerebral perforating arteries with 7-T MRI. A two-dimensional (2D), single-slice quantitative flow (Qflow) sequence was used to measure blood flow velocities during the cardiac cycle in perforating arteries in the basal ganglia (BG) and semioval centre (CSO), from which a mean normalised pulsatility index (PI) per region was calculated (n = 6 human subjects, aged 23-29 years). The precision of the measurements was determined by repeated imaging and performance of a Bland-Altman analysis, and confounding effects of partial volume and noise on the measurements were simulated. The median number of arteries included was 14 in CSO and 19 in BG. In CSO, the average velocity per volunteer was in the range 0.5-1.0 cm/s and PI was 0.24-0.39. In BG, the average velocity was in the range 3.9-5.1 cm/s and PI was 0.51-0.62. Between repeated scans, the precision of the average, maximum and minimum velocity per vessel decreased with the size of the arteries, and was relatively low in CSO and BG compared with the M1 segment of the middle cerebral artery. The precision of PI per region was comparable with that of M1. The simulations proved that velocities can be measured in vessels with a diameter of more than 80 µm, but are underestimated as a result of partial volume effects, whilst pulsatility is overestimated. Blood flow velocity and pulsatility in cerebral perforating arteries have been measured directly in vivo for the first time, with moderate to good precision. This may be an interesting metric for the study of haemodynamic changes in aging and cerebral small vessel disease. © 2015 The Authors NMR in Biomedicine Published by John Wiley & Sons Ltd.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Cerebral/métodos , Artérias Cerebrais/fisiologia , Circulação Cerebrovascular/fisiologia , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia , Adulto , Artérias Cerebrais/anatomia & histologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
NMR Biomed ; 29(6): 709-20, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27037615

RESUMO

Widespread use of ultrahigh-field (31) P MRSI in clinical studies is hindered by the limited field of view and non-uniform radiofrequency (RF) field obtained from surface transceivers. The non-uniform RF field necessitates the use of high specific absorption rate (SAR)-demanding adiabatic RF pulses, limiting the signal-to-noise ratio (SNR) per unit of time. Here, we demonstrate the feasibility of using a body-sized volume RF coil at 7 T, which enables uniform excitation and ultrafast power calibration by pick-up probes. The performance of the body coil is examined by bench tests, and phantom and in vivo measurements in a 7-T MRI scanner. The accuracy of power calibration with pick-up probes is analyzed at a clinical 3-T MR system with a close to identical (1) H body coil integrated at the MR system. Finally, we demonstrate high-quality three-dimensional (31) P MRSI of the human body at 7 T within 5 min of data acquisition that includes RF power calibration. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Imagem Molecular/instrumentação , Compostos de Fósforo/metabolismo , Isótopos de Fósforo/farmacocinética , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
10.
Neuroradiology ; 58(9): 853-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27236563

RESUMO

INTRODUCTION: Cerebellar cortical infarct cavities are a newly recognised entity associated with atherothromboembolic cerebrovascular disease and worse physical functioning. We aimed to investigate the relationship of cerebellar cortical infarct cavities with symptomatic vertebrobasilar ischaemia and with vascular risk factors. METHODS: We evaluated the MR images of 46 patients with a recent vertebrobasilar TIA or stroke and a symptomatic vertebral artery stenosis ≥50 % from the Vertebral Artery Stenting Trial (VAST) for the presence of cerebellar cortical infarct cavities ≤1.5 cm. At inclusion in VAST, data were obtained on age, sex, history of vertebrobasilar TIA or stroke, and vascular risk factors. Adjusted risk ratios were calculated with Poisson regression analyses for the relation between cerebellar cortical infarct cavities and vascular risk factors. RESULTS: Sixteen out of 46 (35 %) patients showed cerebellar cortical infarct cavities on the initial MRI, and only one of these 16 patients was known with a previous vertebrobasilar TIA or stroke. In patients with symptomatic vertebrobasilar ischaemia, risk factor profiles of patients with cerebellar cortical infarct cavities were not different from patients without these cavities. CONCLUSION: Cerebellar cortical infarct cavities are seen on MRI in as much as one third of patients with recently symptomatic vertebral artery stenosis. Since patients usually have no prior history of vertebrobasilar TIA or stroke, cerebellar cortical infarct cavities should be added to the spectrum of common incidental brain infarcts visible on routine MRI.


Assuntos
Doenças Cerebelares/epidemiologia , Infarto Cerebral/epidemiologia , Angiografia por Ressonância Magnética/estatística & dados numéricos , Insuficiência Vertebrobasilar/epidemiologia , Insuficiência Vertebrobasilar/cirurgia , Distribuição por Idade , Causalidade , Doenças Cerebelares/diagnóstico por imagem , Doenças Cerebelares/prevenção & controle , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/prevenção & controle , Comorbidade , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prevalência , Fatores de Risco , Distribuição por Sexo , Stents/estatística & dados numéricos , Resultado do Tratamento , Insuficiência Vertebrobasilar/diagnóstico por imagem
11.
NMR Biomed ; 28(4): 514-22, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25802216

RESUMO

Lactate levels are measurable by MRS and are related to neural activity. Therefore, it is of interest to accurately measure lactate levels in the basal ganglia networks. If sufficiently stable, lactate measurements may be used to investigate alterations in dopaminergic signalling in the striatum, facilitating the detection and diagnosis of metabolic deficits. The aim of this study is to provide a J-difference editing MRS technique for the selective editing of lactate only, thus allowing the detection of lactate without contamination of overlapping macromolecules. As a validation procedure, macromolecule nulling was combined with J-difference editing, and this was compared with J-difference editing with a new highly selective editing pulse. The use of a high-field (7T) MR scanner enables the application of editing pulses with very narrow bandwidth, which are selective for lactate. We show that, despite the sensitivity to B0 offsets, the use of a highly selective editing pulse is more efficient for the detection of lactate than the combination of a broad-band editing pulse with macromolecule nulling. Although the signal-to-noise ratio of uncontaminated lactate detection in healthy subjects is relatively low, this article describes the test-retest performance of lactate detection in the striatum when using highly selective J-difference editing MRS at 7 T. The coefficient of variation, σw and intraclass correlation coefficients for within- and between-subject differences of lactate were determined. Lactate levels in the left and right striatum were determined twice in 10 healthy volunteers. Despite the fact that the test-retest performance of lactate detection is moderate with a coefficient of variation of about 20% for lactate, these values can be used for the design of new studies comparing, for example, patient populations with healthy controls.


Assuntos
Corpo Estriado/química , Ácido Láctico/análise , Espectroscopia de Ressonância Magnética , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Gânglios da Base/química , Colina/análise , Creatina/análise , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
12.
Mult Scler ; 21(2): 155-62, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25013150

RESUMO

BACKGROUND: Virchow-Robin spaces (VRS) are associated with vascular and neurodegenerative disease. In multiple sclerosis (MS), VRS have been associated with neuroinflammation. Ultra-high field imaging may be used to gain insight in these contradictory findings. OBJECTIVE: The objective of this paper is to analyze VRS in MS patients using high-resolution 7 Tesla (T) MRI. Additionally, we investigated whether the widening of VRS is related to inflammatory or neurodegenerative aspects of MS. METHODS: Thirty-four MS patients and 11 healthy controls were examined at 7T. Number and size of VRS were measured on three-dimensional (3D) T1-weighted images, and 3D fluid-attenuated inversion recovery (FLAIR) images were used for MS lesion detection. Brain atrophy was quantified by computing supratentorial brain volume fraction (sBVF). VRS counts were correlated with clinical variables, lesion count and sBVF. RESULTS: MS patients displayed more VRS (median 11) than healthy controls (median four), p = 0.001. VRS size did not differ between both groups. VRS count in MS patients was associated with sBVF (rho = -0.40, p = 0.02), but not with lesion count (p = 0.22). CONCLUSIONS: The 7T MRI reveals increased numbers of VRS in MS. The finding that VRS are associated with supratentorial brain atrophy, but not with lesion count, suggests that VRS might rather serve as a neurodegenerative than an inflammatory marker in MS.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Doenças Neurodegenerativas/patologia , Adulto , Atrofia/patologia , Biomarcadores , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Doenças Neurodegenerativas/diagnóstico
13.
Breast Cancer Res Treat ; 144(3): 583-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24570008

RESUMO

Phosphorus metabolite ratios are potential biomarkers in breast cancer diagnosis and treatment monitoring. Our purpose was to investigate the metabolite ratios phosphomonoester to phosphodiester, phosphoethanolamine (PE) to glycerophosphoethanolamine (GPE), and phosphocholine (PC) to glycerophosphocholine (GPC) in glandular breast tissue, and the potential effect of the menstrual cycle, using (31)P magnetic resonance spectroscopy (MRS) at 7T. Seven women with regular menstrual cycles each underwent four examinations using a 3D (31)P multi-echo magnetic resonance spectroscopic imaging sequence. Peak integrals were assessed using IDL and JMRUI software. First, T2 relaxation times were calculated using multi-echo data pooled across subjects and time points. Subsequent, metabolite ratios were calculated for each phase of the menstrual cycle using the calculated T2 values to account for when combining the free induction decay and all five echoes. The metabolite ratios were calculated both on group level and individually. T2 decay fits resulted in a T2 relaxation time for PE of 154 ms (95 % CI 144-164), for PC of 173 ms (95 % CI 148-205), for Pi of 188 ms (95 % CI 182-193), for GPE of 48 ms (95 % CI 44-53), and for GPC of 23 ms (95 % CI 21-26). The metabolite ratios analyzed on group level showed negligible variation throughout the menstrual cycle. Individual results did show an apparent intra-individual variation; however, not significant due to the measurements' uncertainty. To conclude, phospholipids in glandular tissue as measured with (31)P MRS at 7 T are not significantly affected by the menstrual cycle.


Assuntos
Mama/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Ciclo Menstrual/metabolismo , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Metabolômica/métodos , Fósforo/metabolismo , Adulto Jovem
14.
Magn Reson Med ; 71(4): 1641-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23788130

RESUMO

PURPOSE: Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilitates RF shimming based on the traveling waves. METHODS: The multimode, coaxial waveguide combines the coaxial waveguide, cylindrical waveguide, high dielectric permittivity lining, and eight radial stub antennas. Each antenna excites multiple waveguide modes. Based on modes orthogonality, a method was devised to decompose an excitation pattern of single stub antenna into waveguide modes. RESULTS: The number of modes present in the excitation pattern of a single stub antenna increased with the higher effective permittivity of the dielectric lining. Thus, RF shimming performance of the setup was improved. An average homogeneity of 10% was demonstrated for a single slice of each principle plane in the human head at 7 T. CONCLUSION: Traveling wave RF shimming is feasible both in axial and longitudinal directions and is improved with an increased amount of orthogonal waveguide modes. Nevertheless, with the currently available RF amplifiers at 7 T, the performance of the setup is limited to low flip angles.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Campos Magnéticos , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
15.
NMR Biomed ; 27(10): 1248-55, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25146680

RESUMO

Here, we show that the sensitivity of (31)P MRSI of (31)P spins J-coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi-echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi-echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7-T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal-to-noise ratio (SNR) enhancement for the J-coupled phosphomonoesters was 270% when compared with an Ernst angle pulse-acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled (31)P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst-angle excitation pulse-acquire sequence by multi-echo direct detection.


Assuntos
Mama/química , Espectroscopia de Ressonância Magnética/métodos , Adulto , Algoritmos , Etanolaminas/análise , Feminino , Glicerilfosforilcolina/análise , Humanos , Isótopos de Fósforo , Fosforilcolina/análise , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
16.
NMR Biomed ; 27(11): 1353-60, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25212868

RESUMO

Spectral degradations as a result of temporal field variations are observed in MRSI of the human prostate. Moving organs generate substantial temporal and spatial field fluctuations as a result of susceptibility mismatch with the surrounding tissue (i.e. periodic breathing, cardiac motion or random bowel motion). Nine patients with prostate cancer were scanned with an endorectal coil (ERC) on a 7-T MR scanner. Temporal B0 field variations were observed with fast dynamic B0 mapping in these patients. Simulations of dynamic B0 corrections were performed using zero- to second-order shim terms. In addition, the temporal B0 variations were applied to simulated MR spectra causing, on average, 15% underestimation of the choline/citrate ratio. Linewidth distortions and frequency shifts (up to 30 and 8 Hz, respectively) were observed. To demonstrate the concept of observing local field fluctuations in real time during MRSI data acquisition, a field probe (FP) tuned and matched for the (19) F frequency was incorporated into the housing of the ERC. The data acquired with the FP were compared with the B0 field map data and used to correct the MRSI datasets retrospectively. The dynamic B0 mapping data showed variations of up to 30 Hz (0.1 ppm) over 72 s at 7 T. The simulated zero-order corrections, calculated as the root mean square, reduced the standard deviation (SD) of the dynamic variations by an average of 41%. When using second-order corrections, the reduction in the SD was, on average, 56%. The FP data showed the same variation range as the dynamic B0 data and the variation patterns corresponded. After retrospective correction, the MRSI data showed artifact reduction and improved spectral resolution. B0 variations can degrade the MRSI substantially. The simple incorporation of an FP into an ERC can improve prostate cancer MRSI without prior knowledge of the origin of the dynamic field distortions.


Assuntos
Adenocarcinoma/química , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Próstata/química , Neoplasias da Próstata/química , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Algoritmos , Artefatos , Colina/análise , Citratos/análise , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Masculino , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Reto , Fatores de Tempo
17.
Magn Reson Med ; 70(3): 885-94, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23044511

RESUMO

Application of travelling wave MR to human body imaging is restricted by the limited peak power of the available RF amplifiers. Nevertheless, travelling wave MR advantages like a large field of view excitation and distant location of transmit elements would be desirable for whole body MRI. In this work, improvement of the B1+ efficiency of travelling wave MR is demonstrated. High permittivity dielectric lining placed next to the scanner bore wall effectively reduces attenuation of the travelling wave in the longitudinal direction and at the same time directs the radial power flow toward the load. First, this is shown with an analytical model of a metallic cylindrical waveguide with the dielectric lining next to the wall and loaded with a cylindrical phantom. Simulations and experiments also reveal an increase of B1+ efficiency in the center of the bore for travelling wave MR with a dielectric lining. Phantom experiments show up to a 2-fold gain in B1+ with the dielectric lining. This corresponds to a 4-fold increase in power efficiency of travelling wave MR. In vivo experiments demonstrate an 8-fold signal-to-noise ratio gain with the dielectric lining. Overall, it is shown that dielectric lining is a constructive method to improve efficacy of travelling wave MR.


Assuntos
Imageamento por Ressonância Magnética/métodos , Humanos , Modelos Teóricos , Imagens de Fantasmas
18.
Magn Reson Med ; 69(4): 1186-93, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22760686

RESUMO

A setup for 7T MRI of the carotid arteries in the neck was designed and constructed. Separate dedicated arrays were used for transmit and receive. For the transmit array, single-side adapted dipole antennas were mounted on a dielectric pillow, which was shown to serve as a leaky waveguide, efficiently distributing B1 into the neck. Risk assessment was performed by simulations. Phantom measurements were performed to establish optimal positions of the antennas on the pillow. Using two antennas, a dual transmit setup was created. In vivo B1 (+) maps with different shim configurations were acquired to assess transmit performance. This effective transmit array was used in combination with a dedicated 30 channel small element receive coil. High-resolution in vivo turbo spin echo images were acquired to demonstrate the excellent performance of the setup.


Assuntos
Artérias Carótidas/anatomia & histologia , Aumento da Imagem/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
NMR Biomed ; 26(11): 1596-601, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23893556

RESUMO

A method to measure the T2 relaxation time of GABA with spectral editing techniques is proposed. Spectral editing techniques can be used to unambiguously extract signals of low concentration J-coupled spins such as γ-aminobutyric acid (GABA) from overlapping resonances such as creatine and macromolecules. These sequences, however, generally have fixed and relatively long echo times. Therefore, for the absolute quantification of the edited spectrum, the T2 relaxation time must be taken into account. To measure the T2 relaxation time, the signal intensity has to be obtained at multiple echo times. However, on a coupled spin system such as GABA this is challenging, since the signal intensity of the target resonances is modulated not only by T2 decay but also by the J-coupling, which strongly influences the shapes and amplitudes of the edited signals, depending on the echo time. Here, we propose to refocus the J-modulation of the edited signal at different echo times by using chemical shift selective refocusing. In this way the echo time can be arbitrarily extended while preserving the shape of the edited signal. The method was applied in combination with the MEGA-sLASER editing technique to measure the in vivo T2 relaxation time of GABA (87 ± 11 ms, n = 10) and creatine (109 ± 8 ms, n = 10) at 7 T. The T1 relaxation time of these metabolites in a single subject was also determined (GABA, 1334 ± 158 ms; Cr, 1753 ± 12 ms). The T2 decay curve of coupled spin systems can be sampled in an arbitrary fashion without the need for signal shape correction. Furthermore, the method can be applied with any spectral editing technique. The shortest echo time of the method is limited by the echo time of the spectral editing technique.


Assuntos
Imageamento por Ressonância Magnética , Ácido gama-Aminobutírico/metabolismo , Creatina/metabolismo , Humanos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Fatores de Tempo
20.
NMR Biomed ; 26(4): 436-42, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23074162

RESUMO

Higher magnetic field strengths, such as 7 T, offer increased spectral resolution and higher signal-to-noise ratio. These properties can be very advantageous for MRSI. In particular, signals that generally overlap at lower fields, such as choline, polyamines and creatine, can be resolved at 7 T. However, higher magnetic field strengths suffer from strong radiofrequency (RF) field nonuniformities. These nonuniformities become even stronger when using surface transceivers, such as an endorectal coil for prostate imaging. In order to obtain uniform excitations for accurate MRSI measurements, adiabatic sequences are therefore recommended. Conventional adiabatic MRS sequences (i.e. localization by adiabatic selective refocusing, LASER) have relatively long TEs, especially when optimized to measure the strongly coupled spins of citrate in the prostate. The semi-LASER (sLASER) sequence has a significantly shorter TE, although it does not provide adiabatic excitation. Therefore, we propose an adiabatic sLASER sequence that either has a composite adiabatic slice-selective excitation (cLASER) or a non-slice-selective adiabatic excitation (nsLASER), allowing for shorter TEs, whilst maintaining the adiabatic spin excitation. Furthermore, the spatial properties of the composite adiabatic excitation allow for a high slice excitation bandwidth, resulting in negligible chemical shift displacement artifacts. Exclusion of the slice selection can be considered once the field of view extends beyond the transmit field of the RF coil. The use of a transceiver at high magnetic field strengths has shown that the cLASER and nsLASER sequences are suitable for MRSI of the prostate in both phantom and in vivo validations.


Assuntos
Espectroscopia de Ressonância Magnética , Próstata/patologia , Simulação por Computador , Humanos , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Ondas de Rádio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA