Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 44(10): 1663-1670, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34319603

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV-LV conduction is typically measured in intrinsic rhythm. The differences in RV-LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood. METHODS: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing. RESULTS: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV-LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra-LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%. CONCLUSIONS: Differences in RV-LV conduction time, intra-LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Humanos , Masculino , Desenho de Prótese
2.
J Cardiovasc Electrophysiol ; 31(4): 825-833, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32009263

RESUMO

BACKGROUND: The AdaptivCRT (aCRT) algorithm continuously adjusts cardiac resynchronization therapy (CRT) according to intrinsic atrioventricular conduction, providing synchronized left ventricular pacing in patients with normal PR interval and adaptive BiV pacing in patients with prolonged PR interval. Previous analyses demonstrated an association between aCRT and clinical benefit. We evaluated the incidence of patient mortality and atrial fibrillation (AF) with aCRT compared with standard CRT in a real-world population. METHODS AND RESULTS: Patients enrolled in the Medtronic Personalized CRT Registry and implanted with a CRT from 2013-2018 were divided into aCRT ON or standard CRT groups based upon device-stored data. A Frailty survival model was used to evaluate the potential survival benefit of aCRT, accounting for patient heterogeneity and center variability. Daily AF burden and first device-detected AF episodes of various durations were recorded by the device during follow-up. A total of 1814 CRT patients with no reported long-standing AF history at implant were included. Mean follow-up time was 26.1 ± 16.5 months and 1162 patients (64.1%) had aCRT ON. Patient survival probability at 36 months was 88.3% for aCRT ON and 83.7% for standard CRT (covariate-adjusted hazard ratio [HR] = 0.71, 95% CI: 0.53-0.96, P = .028). Mean AF burden during follow-up was consistently lower in aCRT ON patients compared with standard CRT. At 36 months, the probability of AF was lower in patients with aCRT ON, regardless of which AF definition threshold was applied (6 minutes-30 days, all P < .001). CONCLUSION: Use of the AdaptivCRT algorithm was associated with improved patient survival and lower incidence of AF in a real-world, prospective, nonrandomized registry.


Assuntos
Algoritmos , Fibrilação Atrial/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Terapia Assistida por Computador/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Electrocardiol ; 60: 33-35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32240867

RESUMO

About 4.5-20% of patients after heart transplant require pacemaker (PM) implantation. The high infective risk profile and the low probability of pacing dependency make heart-transplanted patients the ideal candidates for a leadless single-chamber PM. We report the first multicenter experience of leadless PM implantation in a series of heart-transplanted patients with a long-term follow-up. Our data confirm the feasibility and acceptable safety of leadless device in this peculiar kind of patients, despite implantation seems to be slightly more challenging with respect to non-transplanted patients. Although more data are required, a leadless single-chamber surveillance PM seems a valuable option for heart-transplanted patients.


Assuntos
Transplante de Coração , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Eletrocardiografia , Desenho de Equipamento , Humanos , Resultado do Tratamento
4.
Europace ; 19(11): 1767-1775, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28031277

RESUMO

AIMS: To evaluate if the increased thromboembolic risk in female patients may be related to a higher burden of atrial fibrillation (AF). METHODS AND RESULTS: Data collected in a prospective observational research of patients implanted with a cardiac implantable electrical device (CIED) were analysed. We included 2398 patients: 489 (20.4%) were female and 1909 (79.6%) were male (oral anticoagulants treatment in 23.2%, independent of gender). During the follow-up (mean 42.8, median 37.7 months), 26 thromboembolic events occurred in 22 patients, with an incidence rate ratio of both stroke and stroke/transient ischemic attack (TIA) significantly higher in females compared with males [2.00, 95% confidence interval (CI) 1.53-2.61, P< 0.001 for stroke; 1.77 (95% C1.37-2.31, P< 0.001 for stroke/TIA]. An AF burden ≥5 min was a common finding (44% of patients), with no difference between men and women. The maximum daily AF burden and the time to evolution in permanent AF did not differ according to gender. The results of multivariate Cox regression showed that female gender, as well as history of CABG, were significant independent predictors of stroke and female gender was also an independent predictor of stroke/TIA. CONCLUSIONS: Among patients implanted with a CIED, an AF burden of at least 5 min is a common finding, (44% of patients). Female patients have a risk of stroke and TIAs that is around two-fold that of male patients, but this increased risk cannot be ascribed to a higher burden of AF or to differences in the evolution to permanent AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01007474.


Assuntos
Fibrilação Atrial/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Ataque Isquêmico Transitório/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Incidência , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/prevenção & controle , Itália/epidemiologia , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo
5.
Pacing Clin Electrophysiol ; 40(1): 46-56, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27862043

RESUMO

BACKGROUND: Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. METHODS: A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. RESULTS: Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. CONCLUSION: This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Crioterapia/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causalidade , Estudos de Coortes , Comorbidade , Estudos de Viabilidade , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/estatística & dados numéricos , Adulto Jovem
6.
Europace ; 18(9): 1391-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26826135

RESUMO

AIMS: Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. METHODS AND RESULTS: We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0-3.5] in Control CRT-D and 0.9% (CI = 0.4-2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21-0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16-0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11-0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1-4.2) in New CRT-D and 3.2 (CI = 2.1-5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2-0.9) in New CRT-D and 0.7 (CI = 0.5-1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6-1.6) in New CRT-D and 3.5 (CI = 3.0-4.1) in Control CRT-D (P < 0.001). CONCLUSION: Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.


Assuntos
Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/terapia , Falha de Prótese , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/prevenção & controle , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Bases de Dados Factuais , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
7.
Europace ; 18(11): 1719-1725, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27485577

RESUMO

AIMS: A long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial. METHODS AND RESULTS: A total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections). A total of 346 fast ventricular tachycardias (FVT) were detected in 169 patients: 208 in 105 patients with SDI and 138 in 64 patients with LDI. Setting LDI determined a significant reduction in appropriate but unnecessary therapies [208 in SDI vs. 138 in LDI; incidence rate ratio (IRR): 0.61 (95% CI 0.45-0.83), P = 0.002]. Anti-tachycardia pacing determined another 52% reduction in unnecessary shocks [208 in SDI with hypothetical shock-only programming vs. 66 in LDI with ATP; IRR: 0.37 (95% CI 0.25-0.53, P < 0.001)]. The efficacy of ATP in terminating FVT was 63% in SDI and 52% in LDI (P = 0.022). No difference in the safety profile (acceleration/degeneration and death/cardiovascular hospitalizations) was observed between the two groups. CONCLUSION: The combination of LDI and ATP during charging is extremely effective and significantly reduces appropriate but unnecessary therapies. The use of LDI alone yielded a 39% reduction in appropriate but unnecessary therapies; ATP on top of LDI determined another 52% reduction in unnecessary shocks. The strategy of associating ATP and LDI could be considered in the majority of ICD recipients.


Assuntos
Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Taquicardia Ventricular/terapia , Idoso , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevenção Secundária , Método Simples-Cego , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento
8.
Eur Heart J ; 36(24): 1529-35, 2015 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-25825044

RESUMO

AIMS: Opinions differ regarding the effectiveness of cardiac pacing in patients affected by reflex syncope. We assessed a standardized guideline-based algorithm in different forms of reflex syncope. METHODS AND RESULTS: In this prospective, multi-centre, observational study, patients aged >40 years, affected by severe unpredictable recurrent reflex syncopes, underwent carotid sinus massage (CSM), followed by tilt testing (TT) if CSM was negative, followed by implantation of an implantable loop recorder (ILR) if TT was negative. Those who had an asystolic response to one of these tests received a dual-chamber pacemaker. POPULATION: 253 patients, mean age 70 ± 12 years, median 4 (3-6) syncopes, 89% without or with short prodromes. Of these patients, 120 (47%) received a pacemaker and 106 were followed up for a mean of 13 ± 7 months: syncope recurred in 10 (9%). The recurrence rate was similar in 61 CSM+ (11%), 30 TT+ (7%), and 15 ILR+ (7%) patients. The actuarial total syncope recurrence rate was 9% (95% confidence interval (CI), 6-12) at 1 year and 15% (95% CI, 10-20) at 2 years and was significantly lower than that observed in the group of 124 patients with non-diagnostic tests who had received an ILR: i.e. 22% (95% CI, 18-26) at 1 year and 37% (95% CI, 30-43) at 2 years (P = 0.004). CONCLUSION: About half of older patients with severe recurrent syncopes without prodromes have an asystolic reflex for which cardiac pacing goes along with a low recurrence rate. The study supports the clinical utility of the algorithm for the selection of candidates to cardiac pacing in everyday clinical practice. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT01509534.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial , Síncope/terapia , Idoso , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Humanos , Masculino , Massagem/métodos , Estudos Prospectivos , Prevenção Secundária , Síncope/etiologia , Síncope/prevenção & controle , Teste da Mesa Inclinada , Resultado do Tratamento
9.
Circulation ; 130(4): 308-14, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-24838360

RESUMO

BACKGROUND: Three trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients. METHODS AND RESULTS: Of the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤ 320 ms. Eight-five percent of patients were men, with a mean age of 65 ± 12 years, a previous history of ventricular fibrillation in 37% of the cases, and a mean ejection fraction of 38 ± 13%. The ICD device mix was 37% single chamber, 47% dual chamber, and 16% triple chamber. Over a median period of 12 months, the long detection period was associated with a 25% reduction in the number of overall therapies (115.6 versus 86.8 per 100 patient-years; incidence rate ratio, 0.75; 95% confidence interval, 0.61-0.93; P=0.008) and a 34% reduction in the number of shocks (rate per 100 patient-years, 51.2 versus 38.1; incidence rate ratio, 0.66; 95% confidence interval, 0.48-0.89; P=0.007). Appropriate therapies (89.7 versus 67.7; incidence rate ratio, 0.77; 95% confidence interval, 0.60-0.97; P=0.029) and appropriate shocks (37.1 versus 28.1; incidence rate ratio, 0.64; 95% confidence interval, 0.45-0.93; P=0.018) were also reduced. CONCLUSIONS: ADVANCE III is the first randomized trial to assess a long detection window setting in ICDs in both primary and secondary prevention populations and demonstrates a reduction of overall therapies and shocks in the subgroup of secondary prevention patients. These data suggest that even the secondary prevention population may benefit from programming that combines a long detection period with antitachycardia pacing during charging. CLINICAL TRIAL REGISTRATION URL: http://www/clinicaltrials.gov. Unique identifier: NCT00617175.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/prevenção & controle , Idoso , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento , Feminino , Frequência Cardíaca , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Prevenção Secundária , Método Simples-Cego , Volume Sistólico , Síncope/epidemiologia , Síncope/etiologia , Taquicardia Ventricular/terapia , Fatores de Tempo , Fibrilação Ventricular/terapia
10.
Europace ; 16(6): 914-22, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24158255

RESUMO

AIMS: To assess the diagnostic yield of new external loop recorders (ELRs) in patients with history of syncope, pre-syncope, and sustained palpitations. METHODS AND RESULTS: Since 2005, we have established a registry including patients who consecutively received ELR monitoring for unexplained syncope or pre-syncope/palpitations. The registry included 307 patients (61% females, age 58 ± 19 years, range 8-94 years) monitored by high-capacity memory ELR of two subsequent generations: SpiderFlash-A(®) (SFA(®), Sorin CRM), storing two-lead electrocardiogram (ECG) patient-activated recordings by loop-recording technique (191 patients, 54 patients with syncope, years 2005-09), and SpiderFlash-T(®) (SFT(®)), adding auto-trigger detection for pauses, bradycardia, and supraventricular/ventricular arrhythmias (116 patients, 38 patients with syncope, years 2009-12). All the patients previously underwent routine workup for syncope or palpitation, including one or more 24 h Holter, not conclusive for diagnosis. Mean monitoring duration was 24.1 ± 8.9 days. Among 215 patients with palpitations, a conclusive diagnosis was obtained in 184 patients (86% diagnostic yield for palpitation). Among 92 patients with syncope, a conclusive diagnosis was obtained in 16 patients (17% clinical diagnostic yield for syncope), with recording during syncope of significant arrhythmias in 9 patients, and sinus rhythm in 7 patients. Furthermore, asymptomatic arrhythmias were de novo detected in 12 patients (13%), mainly by auto-trigger detection, suggesting an arrhythmic origin of the syncope. CONCLUSIONS: The diagnostic yield of ELR in patients with syncope, pre-syncope, or palpitation of unknown origin after routine workup was similar to implantable loop recorder (ILR) within the same timeframe, therefore, ELR could be considered for patients candidate for long-term ECG monitoring, stepwise before ILR.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Síncope/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/epidemiologia , Causalidade , Criança , Comorbidade , Diagnóstico Diferencial , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síncope/epidemiologia , Adulto Jovem
11.
Europace ; 16(3): 354-62, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24200715

RESUMO

AIMS: The general clinical profile of European pacemaker recipients who require predominant ventricular pacing (VP) is scarcely known. We examined the demographic and clinical characteristics of the 1808 participants (out of 1833 randomized patients) of the ongoing Biventricular Pacing for Atrio-ventricular Block to Prevent Cardiac Desynchronization (BioPace) study. METHODS AND RESULTS: BioPace recruited patients between May 2003 and September 2007 predominantly in European medical centres. We analysed demographic data and described clinical characteristics and electrophysiological parameters prior to device implantation in 1808 enrolled patients. The mean age ± standard deviation (SD) of the 1808 patients was 73.5 ± 9.2 years, 1235 (68%) were men, 654 (36%) presented without structural heart disease, 547 (30%) had ischemic, 355 (20%) hypertensive, 146 (8%) valvular, and 102 (6%) non-ischemic dilated cardiomyopathy. Mean left ventricular ejection fraction was 55.4 ± 12.3%. The main pacing indications were (a) permanent and intermittent atrioventricular (AV) block in 973 (54%), (b) atrial fibrillation with slow ventricular rate in 313 (17%), and (c) miscellaneous bradyarrhythmias in 522 (29%) patients. Mean QRS duration was 118.5 ± 30.5 ms, left bundle branch block was present in 316 (17%), and atrial tachyarrhythmias in 426 (24%) patients. CONCLUSION: To the best of our knowledge, this sample is a representative source of description of the general profile of European pacemaker recipients who require predominant VP. Patients' characteristics included advanced age, predominantly male gender, preserved left ventricular systolic function, high-grade AV block, narrow QRS complex, and atrial tachyarrhythmias, the latter being present in nearly one-fourth of the cohort.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/prevenção & controle , Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/prevenção & controle , Terapia de Ressincronização Cardíaca/mortalidade , Distribuição por Idade , Idoso , Comorbidade , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Prevalência , Fatores de Risco , Tamanho da Amostra , Distribuição por Sexo , Taxa de Sobrevida
13.
Circulation ; 125(24): 2985-92, 2012 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-22626743

RESUMO

BACKGROUND: Heart failure patients with implantable cardioverter-defibrillators (ICDs) or an ICD for resynchronization therapy often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. We hypothesized that Internet-based remote interrogation systems could reduce emergency healthcare visits. METHODS AND RESULTS: This multicenter randomized trial involving 200 patients compared remote monitoring with standard patient management consisting of scheduled visits and patient response to audible ICD alerts. The primary end point was the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or ICD-related events. Over 16 months, such visits were 35% less frequent in the remote arm (75 versus 117; incidence density, 0.59 versus 0.93 events per year; P=0.005). A 21% difference was observed in the rates of total healthcare visits for heart failure, arrhythmias, or ICD-related events (4.40 versus 5.74 events per year; P<0.001). The time from an ICD alert condition to review of the data was reduced from 24.8 days in the standard arm to 1.4 days in the remote arm (P<0.001). The patients' clinical status, as measured by the Clinical Composite Score, was similar in the 2 groups, whereas a more favorable change in quality of life (Minnesota Living With Heart Failure Questionnaire) was observed from the baseline to the 16th month in the remote arm (P=0.026). CONCLUSIONS: Remote monitoring reduces emergency department/urgent in-office visits and, in general, total healthcare use in patients with ICD or defibrillators for resynchronization therapy. Compared with standard follow-up through in-office visits and audible ICD alerts, remote monitoring results in increased efficiency for healthcare providers and improved quality of care for patients. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00873899.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Internet , Qualidade da Assistência à Saúde , Idoso , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Qualidade de Vida , Consulta Remota
14.
J Med Internet Res ; 15(5): e106, 2013 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-23722666

RESUMO

BACKGROUND: Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. OBJECTIVE: We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. METHODS: Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. RESULTS: Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. CONCLUSIONS: Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. TRIAL REGISTRATION: ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).


Assuntos
Análise Custo-Benefício , Desfibriladores Implantáveis , Insuficiência Cardíaca/cirurgia , Monitorização Fisiológica/métodos , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/fisiopatologia , Humanos , Monitorização Fisiológica/economia
15.
JAMA ; 309(18): 1903-11, 2013 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-23652522

RESUMO

IMPORTANCE: Using more intervals to detect ventricular tachyarrhythmias has been associated with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. OBJECTIVE: To determine whether using 30 of 40 intervals to detect ventricular arrhythmias (VT) (long detection) during spontaneous fast VT episodes reduces antitachycardia pacing (ATP) and shock delivery more than 18 of 24 intervals (standard detection). DESIGN, SETTING, AND PARTICIPANTS: Randomized, single-blind, parallel-group trial that enrolled 1902 primary and secondary prevention patients (mean [SD] age, 65 [11] years; 84% men; 75% primary prevention ICD) with ischemic and nonischemic etiology undergoing first ICD implant at 1 of 94 international centers (March 2008-December 2010). INTERVENTIONS: Patients were randomized 1:1 to programming with long- (n = 948) or standard-detection (n = 954) intervals. MAIN OUTCOMES AND MEASURES: Total number of ATPs and shocks delivered for all episodes (primary outcomes) and inappropriate shocks, mortality, and syncopal rate (secondary outcomes). RESULTS: During a median follow-up of 12 months (interquartile range, 11-13), long-detection group had 346 delivered therapies (42 therapies per 100 person-years, 95% CI, 38-47) vs 557 in the standard-detection group (67 therapies per 100 person-years [95% CI, 62-73]; incident rate ratio [IRR], 0.63 [95% CI, 0.51-0.78]; P < .001). The long- vs the standard-detection group experienced 23 ATPs per 100 person-years (95% CI, 20-27) vs 37 ATPs per 100 person-years (95% CI, 33-41; IRR, 0.58 [95% CI, 0.47-0.72]; P < .001); 19 shocks per 100 person-years (95% CI, 16-22) vs 30 shocks per 100 person-years (95% CI, 26-34; IRR, 0.77 [95% CI, 0.59-1.01]; P = .06), with a significant difference in the probability of therapy occurrence (P < .001); and a reduction in first occurrence of inappropriate shock (5.1 per 100 patient-years [95% CI, 3.7-6.9] vs 11.6 [95% CI, 9.4-14.1]; IRR, 0.55 [95% CI, 0.36-0.85]; P = .008). Mortality (5.5 [95% CI, 4.0-7.2] vs 6.3 [95% CI, 4.8-8.2] per 100 patient-years; HR, 0.87; P = .50) and arrhythmic syncope rates (3.1 [95% CI, 2.6-4.6] vs 1.9 [95% CI, 1.1-3.1] per 100 patient-years; IRR, 1.60 [95% CI, 0.76-3.41]; P = .22) did not differ significantly between groups. CONCLUSIONS AND RELEVANCE: Among patients receiving an ICD, the use of a long- vs standard-detection interval resulted in a lower rate of ATP and shocks, and inappropriate shocks. This programming strategy may be an appropriate alternative. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00617175.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/métodos , Idoso , Algoritmos , Arritmias Cardíacas/mortalidade , Estimulação Cardíaca Artificial , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Prevenção Primária , Qualidade de Vida , Prevenção Secundária , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
16.
Circulation ; 123(22): 2526-35, 2011 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-21576653

RESUMO

BACKGROUND: Long-term data on device-related untoward events in patients receiving defibrillators for resynchronization therapy (CRT-D) are lacking. We quantified the frequency of repeat invasive procedures and the nature of long-term complications in current clinical practice and examined possible predictors of device-related events and their association with long-term patient outcome. METHODS AND RESULTS: We analyzed data from 3253 patients who underwent de novo successful implantation of CRT-D and were followed up for a median of 18 months (25th to 75th percentiles: 9 to 30) in 117 Italian centers. Device-related events were reported in 416 patients, and, specifically, surgical interventions for system revision were described in 390 patients. Four years after the implantation procedure, 50% of patients underwent surgical revision for battery depletion and 14% for unanticipated events. For comparison, at 4 years battery depletion occurred in 10% and 13% of patients who received single- and dual-chamber defibrillators at the study centers, and unanticipated events were reported as 4% and 9%, respectively. In CRT-D, infections occurred at a rate of 1.0%/y, and the risk of infections increased after device replacement procedures (hazard ratio, 2.04; 95% confidence interval, 1.01 to 4.09; P=0.045). Left ventricular lead dislodgements were reported at a rate of 2.3%/y and were predicted by longer fluoroscopy time and higher pacing threshold on implantation. Device-related events were not associated with a worse clinical outcome; indeed, the risk of death was similar in patients with and without surgical revision (hazard ratio, 0.90; 95% confidence interval, 0.56 to 1.47; P=0.682). CONCLUSIONS: In current clinical practice device-related events are more frequent in CRT-D than in single- or dual-chamber defibrillators, and are frequently managed by surgical intervention for system revision. However, a worse clinical outcome is not associated with these events. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01007474.


Assuntos
Terapia de Ressincronização Cardíaca/efeitos adversos , Bases de Dados Factuais , Desfibriladores Implantáveis/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Reoperação/mortalidade , Reoperação/tendências , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
17.
Circulation ; 124(16): 1719-26, 2011 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-21931078

RESUMO

BACKGROUND: Heart failure is associated with frequent hospitalizations, often resulting from volume overload. Measurement of intrathoracic impedance with an implanted device with an audible patient alert may detect increases in pulmonary fluid retention early. We hypothesized that early intervention could prevent hospitalizations and affect outcome. METHODS AND RESULTS: We studied 335 patients with chronic heart failure who had undergone implantation of an implantable cardioverter-defibrillator alone (18%) or with cardiac resynchronization therapy (82%). All devices featured a monitoring tool to track changes in intrathoracic impedance (OptiVol) and other diagnostic parameters. Patients were randomized to have information available to physicians and patients as an audible alert in case of preset threshold crossings (access arm) or not (control arm). The primary end point was a composite of all-cause mortality and heart failure hospitalizations. During 14.9±5.4 months, this occurred in 48 patients (29%) in the access arm and in 33 patients (20%) in the control arm (P=0.063; hazard ratio, 1.52; 95% confidence interval, 0.97-2.37). This was due mainly to more heart failure hospitalizations (hazard ratio, 1.79; 95% confidence interval, 1.08-2.95; P=0.022), whereas the number of deaths was comparable (19 versus 15; P=0.54). The number of outpatient visits was higher in the access arm (250 versus 84; P<0.0001), with relatively more signs of heart failure among control patients during outpatient visits. Although the trial was terminated as a result of slow enrollment, a post hoc futility analysis indicated that a positive result would have been unlikely. CONCLUSION: Use of an implantable diagnostic tool to measure intrathoracic impedance with an audible patient alert did not improve outcome and increased heart failure hospitalizations and outpatient visits in heart failure patients. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT 00480077.


Assuntos
Terapia de Ressincronização Cardíaca/normas , Cardiografia de Impedância/métodos , Desfibriladores Implantáveis/normas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização/estatística & dados numéricos , Adolescente , Idoso , Terapia de Ressincronização Cardíaca/mortalidade , Doença Crônica , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
18.
J Card Fail ; 18(10): 762-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23040111

RESUMO

BACKGROUND: Reverse remodeling (RR) after cardiac resynchronization therapy (CRT) is associated with favorable clinical outcomes in heart failure (HF). The renin-angiotensin-aldosterone system (RAAS) is involved in the remodeling process. METHODS AND RESULTS: We assessed the association between RR and 8 common RAAS gene variants, which were determined by TaqMan assays, in 156 outpatients with chronic HF. RR was defined as a >15% decrease in left ventricular end systolic volume (LVESV) at 9 (interquartile range 7-12) months after CRT. We matched 76 patients who did not show RR (RR-) to 80 RR+ control subjects by age, sex, HF etiology, New York Heart Association (NYHA) functional class and left ventricular ejection fraction (LVEF). The frequency of the minor allele of the NR3C2 gene (rs5522 C/T), encoding the mineralocorticoid receptor, was higher in RR- than in RR (24/126 vs 10/150; P value after false discovery rate correction: <.0193). Conversely, LVESV decreased significantly less after CRT in carriers of the NR3C2 minor C allele (P = .02). After adjustment for age, sex, NYHA functional class, previous myocardial infarction, atrial fibrillation, and LVEF, RR- remained independently associated with NR3C2 C allele carriage (odds ratio 3.093, 95% confidence interval 1.253-7.632). CONCLUSIONS: The association of RR- after CRT with a common polymorphism in the mineralocorticoid receptor gene involved in aldosterone signaling suggests a possible role for variants in RAAS genes in progressive LV function decline, despite apparently effective CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Variação Genética , Insuficiência Cardíaca/genética , Receptores de Mineralocorticoides/genética , Sistema Renina-Angiotensina/genética , Remodelação Ventricular/genética , Idoso , Estudos de Casos e Controles , Intervalos de Confiança , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fenótipo , Projetos Piloto , Estatística como Assunto , Ultrassonografia
19.
Europace ; 14(9): 1324-33, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22549295

RESUMO

AIMS: Non-response rate to cardiac resynchronization therapy (CRT) might be decreased by optimizing device programming. The Clinical Evaluation on Advanced Resynchronization (CLEAR) study aimed to assess the effects of CRT with automatically optimized atrioventricular (AV) and interventricular (VV) delays, based on a Peak Endocardial Acceleration (PEA) signal system. METHODS AND RESULTS: This multicentre, single-blind study randomized patients in a 1 : 1 ratio to CRT optimized either automatically by the PEA-based system, or according to centres' usual practices, mostly by echocardiography. Patients had heart failure (HF) New York Heart Association (NYHA) functional class III/IV, left ventricular ejection fraction (LVEF) <35%, QRS duration >150 or >120 ms with mechanical dyssynchrony. Follow-up was 1 year. The primary endpoint was the proportion of patients who improved their condition at 1 year, based on a composite of all-cause death, HF hospitalizations, NYHA class, and quality of life. In all, 268 patients in sinus rhythm (63% men; mean age: 73.1 ± 9.9 years; mean NYHA: 3.0 ± 0.3; mean LVEF: 27.1 ± 8.1%; and mean QRS duration: 160.1 ± 22.0 ms) were included and 238 patients were randomized, 123 to PEA and 115 to the control group. At 1 year, 76% of patients assigned to PEA were classified as improved, vs. 62% in the control group (P= 0.0285). The percentage of patients with improved NYHA class was significantly (P= 0.0020) higher in the PEA group than in controls. Fatal and non-fatal adverse events were evenly distributed between the groups. CONCLUSION: PEA-based optimization of CRT in HF patients significantly increased the proportion of patients who improved with therapy, mainly through improved NYHA class, after 1 year of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Endocárdio/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Eletrocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Qualidade de Vida , Volume Sistólico/fisiologia , Resultado do Tratamento
20.
BMC Cardiovasc Disord ; 12: 72, 2012 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-22966862

RESUMO

BACKGROUND: A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients' outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI) and prophylactic cardioverter defibrillator (ICD) implant on device activations. METHODS: 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5%) and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. RESULTS: The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock) were higher in patients implanted longer time from last MI (Gray's Test p=0.002 and p=0.013 respectively). No significant differences were seen in all cause mortality (Gray's Test p=0.618) or sudden cardiac death across the MI stratification groups (Gray's Test p=0.663). CONCLUSIONS: Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Infarto do Miocárdio/complicações , Prevenção Primária/instrumentação , Disfunção Ventricular Esquerda/terapia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Sistema de Registros , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA