Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 95(36): 13586-13595, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37624148

RESUMO

In this paper, we present a highly effective microfluidic emulsion system using an integrated microchannel plate (MCP), a porous glass membrane that is readily available and densely packs millions of through-microchannels, for high-throughput production of monodisperse droplets. The physical controls of droplet formation, including viscosity, flow rate, and pore size, have been extensively explored for optimum emulsification conditions. The performance of the device has been validated where monodisperse droplets with a narrow coefficient of variance (<5%) can be achieved at a dispersed phase flux of 3 mL h-1 from a piece of 4 × 4 mm2 MCP. The average droplet size is two times the nominal membrane pore diameter and thus can be easily controlled by choosing the appropriate membrane type. The preparation of hydrogel microspheres has also been demonstrated with a high throughput of 1.5 × 106 particles min-1. These microspheres with a uniform size range and rough surface morphology provide suitable bioenvironments and serve as ideal carriers for cell culture. Mouse fibroblasts are shown to be cultured on these 3D scaffolds with an average cell viability of over 96%. The cell attachment rate can reach up to 112 ± 7% in 24 h and the proliferation ability increases with the number of culture days. Furthermore, the device has been applied in the droplet digital polymerase chain reaction for absolute quantification of lung cancer-related PLAU genes. The detection limit achieved was noted to be 0.5 copies/µL with a dynamic range of 105 ranging from 1 × 102 to 1 × 106 copies/µL. Given the easy fabrication, robust performance, and simple operation, the emulsion system sets the stage for the laboratory's droplet-based assays and applications in tissue engineering.


Assuntos
Hidrogéis , Microfluídica , Animais , Camundongos , Microesferas , Emulsões , Bandagens
2.
Sensors (Basel) ; 23(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36850733

RESUMO

P(VDF-TrFE) is a promising material for flexible acoustic devices owing to its good piezoelectric performance and excellent stretchability. However, the high density of internal pores and large surface roughness of the conventional P(VDF-TrFE) results in a high propagation attenuation for acoustic waves, which limits its use in flexible acoustic devices. In this paper, a novel method based on two-step annealing is proposed to effectively remove the pores inside the P(VDF-TrFE) film and reduce its surface roughness. The obtained P(VDF-TrFE) film possesses excellent characteristics, including a high breakdown strength of >300 kV/mm, a high-purity ß-phase content of more than 80%, and high piezoelectric coefficients (d33) of 42 pm/V. Based on the low-porosity ß-phase P(VDF-TrFE) film, we fabricated flexible film bulk acoustic resonators (FBARs) which exhibit high sharp resonance peaks. The pressure sensor was made by sandwiching the FBARs with two PDMS microneedle patches. Heartbeat and respiration rate monitoring were achieved using the pressure sensor. This work demonstrates the feasibility of high-performance flexible piezoelectric acoustic resonators based on low-porosity P(VDF-TrFE) films, which could see wider applications in the wearable sensors for both physical and chemical sensing.

3.
Sensors (Basel) ; 23(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37571601

RESUMO

Pain management is a crucial concern in medicine, particularly in the case of children who may struggle to effectively communicate their pain. Despite the longstanding reliance on various assessment scales by medical professionals, these tools have shown limitations and subjectivity. In this paper, we present a pain assessment scheme based on skin potential signals, aiming to convert subjective pain into objective indicators for pain identification using machine learning methods. We have designed and implemented a portable non-invasive measurement device to measure skin potential signals and conducted experiments involving 623 subjects. From the experimental data, we selected 358 valid records, which were then divided into 218 silent samples and 262 pain samples. A total of 38 features were extracted from each sample, with seven features displaying superior performance in pain identification. Employing three classification algorithms, we found that the random forest algorithm achieved the highest accuracy, reaching 70.63%. While this identification rate shows promise for clinical applications, it is important to note that our results differ from state-of-the-art research, which achieved a recognition rate of 81.5%. This discrepancy arises from the fact that our pain stimuli were induced by clinical operations, making it challenging to precisely control the stimulus intensity when compared to electrical or thermal stimuli. Despite this limitation, our pain assessment scheme demonstrates significant potential in providing objective pain identification in clinical settings. Further research and refinement of the proposed approach may lead to even more accurate and reliable pain management techniques in the future.


Assuntos
Dor , Pele , Humanos , Criança , Dor/diagnóstico , Algoritmos , Aprendizado de Máquina , Algoritmo Florestas Aleatórias
4.
Sensors (Basel) ; 23(5)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36904975

RESUMO

The manipulation of biomedical particles, such as separating circulating tumor cells from blood, based on standing surface acoustic wave (SSAW) has been widely used due to its advantages of label-free approaches and good biocompatibility. However, most of the existing SSAW-based separation technologies are dedicated to isolate bioparticles in only two different sizes. It is still challenging to fractionate various particles in more than two different sizes with high efficiency and accuracy. In this work, to tackle the problems of low efficiency for multiple cell particle separation, integrated multi-stage SSAW devices with different wavelengths driven by modulated signals were designed and studied. A three-dimensional microfluidic device model was proposed and analyzed using the finite element method (FEM). In addition, the effect of the slanted angle, acoustic pressure, and the resonant frequency of the SAW device on the particle separation were systemically studied. From the theoretical results, the separation efficiency of three different size particles based on the multi-stage SSAW devices reached 99%, which was significantly improved compared with conventional single-stage SSAW devices.

5.
Anal Chem ; 2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36562720

RESUMO

The atmospheric oxidation of chemicals has produced many new unpredicted pollutants. A microwave plasma torch-based ion/molecular reactor (MPTIR) interfacing an online mass spectrometer has been developed for creating and monitoring rapid oxidation reactions. Oxygen in the air is activated by the plasma into highly reactive oxygen radicals, thereby achieving oxidation of thioethers, alcohols, and various environmental pollutants on a millisecond scale without the addition of external oxidants or catalysts (6 orders of magnitude faster than bulk). The direct and real-time oxidation products of polycyclic aromatic hydrocarbons and p-phenylenediamines from the MPTIR match those of the long-term multistep environmental oxidative process. Meanwhile, two unreported environmental compounds were identified with an MPTIR and measured in the actual water samples, which demonstrates the considerable significance of the proposed device for both predicting the environmental pollutants (non-target screening) and studying the mechanism of atmospheric oxidative processes.

6.
Nanotechnology ; 32(32)2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-33930891

RESUMO

Memristors are an important component of the next-generation artificial neural network, high computing systems, etc. In the past, two-dimensional materials based memristors have achieved a high performance and low power consumption, though one at the cost of the other. Furthermore, their performance can not be modulated frequently once their structures are fixed, which remains the bottleneck in the development. Herein, a series of forming free memristors are fabricated with the same Cu/Fe3GeTe2oxide/Fe3GeTe2/Al structure, yet the On/Off ratio and set voltage is modulated continuously by varying the oxidation time during fabrication. With an optimal oxidation time, a large On/Off ratio (1.58 × 103) and low set voltage (0.74 V) is achieved in a single device. The formation and rapture of Al conductive filaments are found to be responsible for the memristors, and the filaments density and the cross-section area increase with the increase of current compliance, which achieves a higher On/Off ratio. The memristor can imitate basic biological synaptic functions using voltage pulses, demonstrating the potential for low-power consuming neuromorphic computing applications.


Assuntos
Materiais Biomiméticos/química , Eletrônica/métodos , Germânio/química , Ferro/química , Redes Neurais de Computação , Telúrio/química , Animais , Cobre/química , Condutividade Elétrica , Humanos , Oxirredução , Óxidos/química , Sinapses/fisiologia , Transmissão Sináptica/fisiologia
7.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540831

RESUMO

Emotion recognition is of great importance for artificial intelligence, robots, and medicine etc. Although many techniques have been developed for emotion recognition, with certain successes, they rely heavily on complicated and expensive equipment. Skin potential (SP) has been recognized to be correlated with human emotions for a long time, but has been largely ignored due to the lack of systematic research. In this paper, we propose a single SP-signal-based method for emotion recognition. Firstly, we developed a portable wireless device to measure the SP signal between the middle finger and left wrist. Then, a video induction experiment was designed to stimulate four kinds of typical emotion (happiness, sadness, anger, fear) in 26 subjects. Based on the device and video induction, we obtained a dataset consisting of 397 emotion samples. We extracted 29 features from each of the emotion samples and used eight well-established algorithms to classify the four emotions based on these features. Experimental results show that the gradient-boosting decision tree (GBDT), logistic regression (LR) and random forest (RF) algorithms achieved the highest accuracy of 75%. The obtained accuracy is similar to, or even better than, that of other methods using multiple physiological signals. Our research demonstrates the feasibility of the SP signal's integration into existing physiological signals for emotion recognition.


Assuntos
Inteligência Artificial , Emoções , Pele , Algoritmos , Humanos , Modelos Logísticos , Tecnologia sem Fio
8.
Nano Lett ; 20(5): 3263-3270, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32233442

RESUMO

The ability to actuate liquids remains a fundamental challenge in smart microsystems, such as those for soft robotics, where devices often need to conform to either natural or three-dimensional solid shapes, in various orientations. Here, we propose a hierarchical nanotexturing of piezoelectric films as active microfluidic actuators, exploiting a unique combination of both topographical and chemical properties on flexible surfaces, while also introducing design concepts of shear hydrophobicity and tensile hydrophilicity. In doing so, we create nanostructured surfaces that are, at the same time, both slippery (low in-plane pinning) and sticky (high normal-to-plane liquid adhesion). By enabling fluid transportation on such arbitrarily shaped surfaces, we demonstrate efficient fluid motions on inclined, vertical, inverted, or even flexible geometries in three dimensions. Such surfaces can also be deformed and then reformed into their original shapes, thereby paving the way for advanced microfluidic applications.

9.
Nanotechnology ; 31(25): 255204, 2020 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32101798

RESUMO

The increased public concerns on healthcare, the environment and sustainable development inspired the development of biodegradable and biocompatible electronics that could be used as degradable electronics in implants. In this work, a fully biodegradable and flexible resistance random access memory (RRAM) was developed with low-cost biomaterial gelatin as the dielectric layer and the biodegradable polymer poly(lactide-coglycolide) acid (PLGA) as the substrate. PLGA can be synthesized by a simple solution process, and the PLGA substrate can be peeled off the handling substrate for operation once the devices are fabricated. The fabricated memory devices exhibited reliable nonvolatile resistive switching characteristics with a long retention time over 104 s and a near-constant on/off resistance ratio of 102 even after 200 bending cycles, showing the promising potential for application in flexible electronics. Degradation of the devices in deionized water and in phosphate buffered saline (PBS) solution showed that the whole devices can be completely degraded in water. The dissolution time of the metals and the gelatin layer was a few days, while that for PLGA is about 6 months, and can be modified by changing the synthesis conditions of the film, thus allowing the development of biodegradable electronics with designed dissolution time.

10.
Sensors (Basel) ; 20(17)2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-32867180

RESUMO

The lack of a universal simulation method for triboelectric nanogenerator (TENG) makes the device design and optimization difficult before experiment, which protracts the research and development process and hinders the landing of practical TENG applications. The existing electrostatic induction models for TENGs have limitations in simulating TENGs with complex geometries and their dynamic behaviors under practical movements due to the topology change issues. Here, a dynamic finite element method (FEM) model is proposed. The introduction of air buffer layers and the moving mesh method eliminates the topology change issues during practical movement and allows simulation of dynamic and time-varying behaviors of TENGs with complex 2D/3D geometries. Systematic investigations are carried out to optimize the air buffer thickness and mesh densities, and the optimized results show excellent consistency with the experimental data and results based on other existing methods. It also shows that a 3D disk-type rotating TENG can be simulated using the model, clearly demonstrating the capability and superiority of the dynamic FEM model. Moreover, the dynamic FEM model is used to optimize the shape of the tribo-material, which is used as a preliminary example to demonstrate the possibility of designing a TENG-based sensor.

11.
Sensors (Basel) ; 20(24)2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33322434

RESUMO

Platinum (Pt) gratings on langasite (LGS) substrates are a widely used structures in high temperature surface acoustic wave (SAW) devices. Multiple modes can be excited in Pt/LGS SAW devices owing to the heavy weight of the Pt electrode and leaky waves in the LGS substrate. In this work, we report on a detailed mode analysis of Pt/LGS SAW devices, where three commonly used LGS cuts are considered. A three-dimensional (3D) finite element method (FEM) numerical model was developed, and the simulation and experiment results were compared. The experiment and simulation results showed that there are two modes excited in the Pt/LGS SAW devices with Euler angle (0°, 138.5°, 27°) and (0°, 138.5°, 117°), which are Rayleigh-type SAW and SH-type leaky wave, respectively. Only the Rayleigh-type mode was observed in the Pt/LGS SAW devices with Euler angle (0°, 138.5°, 72°). It was found that the acoustic velocities are dependent on the wavelength, which is attributed to the change of wave penetration depth in interdigital transducers (IDTs) and the velocity dispersion can be modulated by the thickness of the Pt electrode. We also demonstrated that addition of an Al2O3 passivation layer has no effect on the wave modes, but can increase the resonant frequencies. This paper provides a better understanding of the acoustic modes of Pt/LGS SAW devices, as well as useful guidance for device design. It is believed that the Rayleigh-type SAW and SH-type leaky waves are potentially useful for dual-mode sensing applications in harsh environments, to achieve multi-parameter monitoring or temperature-compensation on a single chip.

12.
Sensors (Basel) ; 20(5)2020 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-32121461

RESUMO

This paper reports a novel flexible film bulk acoustic resonator (FBAR) based on -phase polyvinylidene fluoride (PVDF) piezoelectric polymer. The proposed device was simulated and evaluated; then, a low-temperature photolithography process with a double exposure method was developed to pattern the electrodes for the device, which enabled the device to retain the piezoelectric properties of the -phase PVDF film. Results showed that the ß-phase PVDF FBARs had a resonant frequency round 9.212 with a high electromechanical coupling coefficient () of 12.76% ± 0.56%. The device performed well over a wide bending-strain range up to 2400 owing to its excellent flexibility. It showed good stability as a strain sensor with a sensitivity of 80 , and no visible deterioration was observed after cyclic bending tests. The PVDF FBAR also exhibited an exceptionally large temperature coefficient of frequency (TCF) of -4630 , two orders of magnitude larger than those of other FBARs based on common inorganic piezoelectric materials, extraordinarily high sensitivity for temperature sensing. All results showed that -phase PVDF FBARs have the potential to expand the application scope for future flexible electronics.

13.
Small ; 15(14): e1805361, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30821937

RESUMO

Cryopreservation is essential to effectively extend the shelf life of delicate biomaterials while maintaining proper levels of cell functions. Cryopreservation requires a cryoprotective agent (CPA) to suppress intracellular ice formation during freezing, but it must be removed prior to clinical use due to its toxicity. Conventional multistep CPA loading and unloading approaches are time consuming, often creating osmotic shocks and causing mechanical injuries for biological samples. An efficient surface-acoustic-wave- (SAW-) based lab-on-a-chip (LoC) for fast loading and removal of CPAs is presented here. With the SAW-based multistep CPA loading/removal approach, high concentration (3 m) CPA can be successfully loaded and removed in less than 1 min. Results show that the technique causes the least harm to umbilical cord matrix mesenchymal stem cells as compared to conventional method, and an average of 24% higher cell recovery rate is achieved, while preserving the integrity and morphology of the cells. This device is the first of its kind to combine high loading/unloading efficiency, high cell viability, and high throughput into one LoC device, offering not only a more efficient and safer route for CPA loading and removal from cells, but also paving the way for other cryopreservation-dependent applications.


Assuntos
Acústica , Membrana Celular/metabolismo , Criopreservação , Crioprotetores/metabolismo , Dispositivos Lab-On-A-Chip , Acústica/instrumentação , Transporte Biológico , Proliferação de Células , Sobrevivência Celular , Matriz Extracelular/metabolismo , Corantes Fluorescentes/química , Humanos , Células-Tronco Mesenquimais/citologia , Propriedades de Superfície , Cordão Umbilical/citologia
14.
Sensors (Basel) ; 19(15)2019 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-31344933

RESUMO

A triboelectric nanogenerator-based self-powered resonant sensor is proposed and investigated. By integrating an inductor and a microswitch with a triboelectric nanogenerator, a new type triboelectric nanogenerator is obtained, the pulse voltage output is converted to an oscillating signal with a very stable modulated resonant frequency, immune to the cross disturbance of contact-related variation (force, frequency, distance) and environmental variation, such as humidity and temperature. This is utilized for non-destructive defect detection. When the coil inductor scans the surface of a specimen with defects, varying resonant frequencies are obtained for different types of defects, showing excellent consistency between the experimental and simulated results. The results demonstrate the potential of the self-powered TENG-based resonant sensor to be a highly stable and sensitive magnetic sensor for the non-destructive defect detection applications.

15.
Rapid Commun Mass Spectrom ; 30(16): 1914-22, 2016 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-27476664

RESUMO

RATIONALE: High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is an analytical technique based on the principle of non-linear electric field dependence of coefficient of mobility of ions for separation that was originally conceived in the Soviet Union in the early 1980s. Being well developed over the past decades, FAIMS has become an efficient method for the separation and characterization of gas-phase ions at ambient pressure, often in air, to detect trace amounts of chemical species including explosives, toxic chemicals, chemical warfare agents and other compounds. However the resolution of FAIMS and ion separation capability need to be improved for more applications of the technique. METHODS: The effects of above-ambient pressure varying from 1 to 3 atm on peak position, resolving power, peak width, and peak intensity are investigated theoretically and experimentally using micro-fabricated planar FAIMS in purified air. RESULTS: Peak positions, varying with pressure in a way as a function of dispersion voltage, could be simplified by expressing both compensation and dispersion fields in Townsend units for E/N, the ratio of electric field intensity (E) to the gas number density (N). CONCLUSIONS: It is demonstrated that ion Townsend-scale peak positions remain unchanged for a range of pressures investigated, implying that the higher the pressure is, stronger compensation and separation fields are needed within limits of air breakdown field. Increase in pressure is found to separate ions that could not be distinguished in ambient pressure, which could be interpreted as the differentials of ions' peak compensation voltage expanded wider than the dilation of peak widths leading to resolving power enhancement with pressure. Increase in pressure can also result in an increase in peak intensity.

16.
Nanotechnology ; 25(35): 355202, 2014 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-25116064

RESUMO

Ultrathin dielectric materials prepared by atomic-layer-deposition (ALD) technology are commonly used in graphene electronics. Using the first-principles density functional theory calculations with van der Waals (vdW) interactions included, we demonstrate that single-side fluorinated graphene (SFG) and hexagonal boron nitride (h-BN) exhibit large physical adsorption energy and strong electrostatic interactions with H2O-based ALD precursors, indicating their potential as the ALD seed layer for dielectric growth on graphene. In graphene-SFG vdW heterostructures, graphene is n-doped after ALD precursor adsorption on the SFG surface caused by vertical intrinsic polarization of SFG. However, graphene-h-BN vdW heterostructures help preserving the intrinsic characteristics of the underlying graphene due to in-plane intrinsic polarization of h-BN. By choosing SFG or BN as the ALD seed layer on the basis of actual device design needs, the graphene vdW heterostructures may find applications in low-dimensional electronics.

17.
Biomicrofluidics ; 18(1): 011303, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38362304

RESUMO

The robust identification and quantification of various biomarkers is of utmost significance in clinical diagnostics and precision medicine. Fluorescent immunoassays are widely used and considered as a gold standard for biomarker detection due to their high specificity and accuracy. However, current commercial immunoassay tests suffer from limited detection sensitivity and complicated, labor-intensive operation procedures, making them impractical for point-of-care diagnosis, particularly in resource-limited regions. Recently, microfluidic immunoassay devices integrated with plasmonic nanostructures have emerged as a powerful tool for sensitive detection of biomarkers, addressing specific issues, such as integration schemes, easy operation, multiplexed detection, and sensitivity enhancement. In this paper, we provide a discussion on the recent advances in the plasmonic nanostructures integrated with microfluidic devices for fluorescent immunoassays. We shed light on the nanofabrication strategies and various fluidic designs for rapid, sensitive, and highly efficient sensing of antigens. Finally, we share our perspectives on the potential directions of these integrated devices for practical applications.

18.
Polymers (Basel) ; 16(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38201815

RESUMO

Poly(vinylidene fluoride-trifluorethylene) (P(VDF-TrFE)) has promising potential applications in radio-frequency filters due to their excellent piezoelectric properties, flexibility, and stability. In this paper, a flexible film bulk acoustic wave filter is investigated based on P(VDF-TrFE) as piezoelectric film. A new method based on three-step annealing is developed to efficiently remove the porosity inside the P(VDF-TrFE) films so as to improve its properties. The obtained film achieved high ß-phase content beyond 80% and a high piezoelectric coefficient of 27.75 pm/V. Based on the low porosity ß-phase films, a flexible wide-band RF filter is designed, which consists of a bulk acoustic wave resonator and lumped inductor-capacitor elements as a hybrid configuration. The resonator sets the filter's center frequency, while the lumped LC-based matching network extends the bandwidth and enhances out-of-band rejection. The testing results of the proposed wide-band filter show its good performance, with 12.5% fractional bandwidth and an insertion loss of 3.1 dB. To verify the possibility of folding and stacking the flexible bulk acoustic wave devices for high-density multi-filter integration in MIMO communication, bending tests of the filter are also conducted with the bending strain range up to 5500 µÎµ. The testing results show no noticeable performance degradation after four bending cycles. This work demonstrates the potential of ß-phase P(VDF-TrFE) bulk acoustic wave filters to expand the scope of future flexible radio-frequency filter applications.

19.
Nanomaterials (Basel) ; 14(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38334511

RESUMO

Advancements in brain-machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT's biocompatibility and chemical inertness, the electrode's flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.

20.
ACS Appl Mater Interfaces ; 16(1): 1492-1501, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38153799

RESUMO

Piezoelectric poly(vinylidene fluoride) (PVDF) and its copolymers have been widely investigated for applications in wearable electric devices and sensing systems, owing to their intrinsic piezoelectricity and superior flexibility. However, their weak piezoelectricity poses major challenges for practical applications. To overcome these challenges, we propose a two-step synthesis approach to fabricate sandwich-structured piezoelectric films (BaTiO3@PDA/PVDF/BaTiO3@PDA) with significantly enhanced ferroelectric and piezoelectric properties. As compared to pristine PVDF films or conventional 0-3 composite films, a maximum polarization (Pmax) of 11.24 µC/cm2, a remanent polarization (Pr) of 5.83 µC/cm2, and an enhanced piezoelectric coefficient (d33 ∼ 14.6 pC/N) were achieved. Simulation and experimental results have demonstrated that the sandwich structure enhances the ability of composite films to withstand higher poling electric fields in comparison with 0-3 composites. The sandwich-structured piezoelectric films are further integrated into a wireless sensor system with a high force sensitivity of 288 mV/N, demonstrating great potential for movement monitoring applications. This facile approach shows great promise for the large-scale production of composite films with remarkable flexibility, ferroelectricity, and piezoelectricity for wearable sensing devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA