Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Pharm Biopharm ; 199: 114278, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38583787

RESUMO

The transfer from batch-based to continuous tablet manufacturing increases the quality and efficiency of processes. Nonetheless, as in the development of a batch process, the continuous process design requires optimization studies to ensure a robust process. In this study, processing of a commercially batch-manufactured tablet product was tested with two continuous direct compression lines while keeping the original formulation composition and tablet quality requirements. Tableting runs were conducted with different values of process parameters. Changes in parameter settings were found to cause differences in tablet properties. Most of these quality properties could be controlled and maintained within the set limits effortlessly already at this stage of studies. However, the API content and content uniformity seemed to require more investigation. The observed content uniformity challenges were traced to individual tablets with a high amount of API. This was suspected to be caused by API micro-agglomerates since tablet weight variability did not explain the issue. This could be solved by adding a mill between two blenders in the process line. Overall, this case study produced promising results with both tested manufacturing lines since many tablet properties complied with the test result limits without optimization of process parameter settings.


Assuntos
Química Farmacêutica , Composição de Medicamentos , Excipientes , Comprimidos , Composição de Medicamentos/métodos , Química Farmacêutica/métodos , Excipientes/química , Tecnologia Farmacêutica/métodos
2.
Int J Pharm ; 647: 123509, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-37832703

RESUMO

As is the case with batch-based tableting processes, continuous tablet manufacturing can be conducted by direct compression or with a granulation step such as dry or wet granulation included in the production procedure. In this work, continuous manufacturing tests were performed with a commercial tablet formulation, while maintaining its original material composition. Challenges were encountered with the feeding performance of the API during initial tests which required designing different powder pre-blend compositions. After the pre-blend optimization phase, granules were prepared with a roller compactor. Tableting was conducted with the granules and an additional brief continuous direct compression run was completed with some ungranulated mixture. The tablets were assessed with off-line tests, applying the quality requirements demanded for the batch-manufactured product. Chemical maps were obtained by Raman mapping and elemental maps by scanning electron microscopy with energy-dispersive X-ray spectroscopy. Large variations in both tablet weights and breaking forces were observed in all tested samples, resulting in significant quality complications. It was suspected that the API tended to adhere to the process equipment, accounting for the low API content in the powder mixture and tablets. These results suggest that this API or the tablet composition was unsuitable for manufacturing in a continuous line; further testing could be continued with different materials and changes in the process.


Assuntos
Tecnologia Farmacêutica , Atorvastatina , Pós/química , Comprimidos/química , Pressão , Composição de Medicamentos/métodos , Tecnologia Farmacêutica/métodos , Tamanho da Partícula
3.
Int J Pharm ; 628: 122355, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36341918

RESUMO

Continuous tablet manufacturing is a competitive option to replace the traditional batch manufacturing approach. The aim of this study was to evaluate technology transfer from batch-based direct compression of a commercial tablet formulation to continuous direct compression without changes to the composition of the formulation. Some powder studies were conducted with the raw materials and multi-tip punches were utilized in the tableting studies. To lower the high level of tablet weight variability that was evident during preliminary tests, a process parameter optimization was performed using an experimental design with different rpm values of force feeder and mixer impeller. By selecting the most appropriate settings of these parameters for the studied product, the weights of the tablets could be controlled adequately to meet the specification criteria. The functionality of the best-performing parameter settings was investigated with a three-hour-long tableting run. The tablets were evaluated with the same quality criteria as the commercial batch-produced tablets, and they passed all the tests performed in this study. Despite the challenging material properties according to the flowability tests, production of tablets with the desired quality was achieved using the original composition with continuous direct compression.


Assuntos
Bisoprolol , Tecnologia Farmacêutica , Comprimidos , Pós , Pressão , Composição de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA