Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Heart Fail Rev ; 29(2): 559-569, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38329583

RESUMO

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Ecocardiografia , Estudos Retrospectivos
2.
Clin Transplant ; 38(6): e15370, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38922995

RESUMO

BACKGROUND: Methods for risk stratification of candidates for heart transplantation (HTx) supported by extracorporeal membrane oxygenation (ECMO) are limited. We evaluated the reliability of the APACHE IV score to identify the risk of mortality in this patient subset in a multicenter study. METHODS: Between January 2010 and December 2022, 167 consecutive ECMO patients were bridged to HTx; they were divided into two groups, according to a cutoff value of APACHE IV score, obtained by receiver operating characteristic curve analysis for 90-day mortality. Kaplan-Meier survival curves were plotted, and compared through the log-Rank test. Cox regression model was used to estimate which factors were associated with survival. RESULTS: The 90-day mortality prediction of the APACHE IV score showed an area under the curve of 0.87 (95% CI: 0.80-0.94), with a cutoff value of 49 (specificity 91.7%-sensibility 69.6%). 125 patients (74.8%) showed an APACHE IV score value < 49 (Group A), and 42 (25.2%) ≥ 49 (Group B). 90-day mortality was 11.2% in Group A and 76.2% in Group B (p < 0.01). Survival at 1 and 5 years was 85.5%, 77% versus 23.4%, 23.4% (p < 0.01) in Groups A and B. Mortality correlated at univariable analysis with recipient age, body mass index, mechanical ventilation, APACHE IV score, and platelets number. At multivariable analysis only APACHE IV score (HR: 1.07 [1.05-1.09, 95% CI]) independently affected survival. CONCLUSIONS: The APACHE IV score represents a powerful predictor of survival in patients bridged to HTx on ECMO support, and could guide candidacy of patients on ECMO.


Assuntos
APACHE , Oxigenação por Membrana Extracorpórea , Transplante de Coração , Humanos , Transplante de Coração/mortalidade , Feminino , Masculino , Prognóstico , Pessoa de Meia-Idade , Seguimentos , Adulto , Taxa de Sobrevida , Estudos Retrospectivos , Fatores de Risco , Curva ROC , Medição de Risco/métodos
3.
Artif Organs ; 46(12): 2486-2492, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35866429

RESUMO

BACKGROUND: We investigated the synergistic effect of the new cone-bearing design of Jarvik 2000 (Jarvik Heart Inc., NY) together with a minimally-invasive approach to outcomes of LVAD patients. METHODS: We retrospectively reviewed all patients from 5 institutions involved in the Jarvik 2000 Italian Registry, from October 2008 to October 2016. Patients were divided into three groups according to pump design and implantation technique: pin-bearing design and conventional approach (Group 1); cone-bearing and conventional approach (Group 2); cone-bearing and minimally-invasive implantation (Group 3). RESULTS: A total of 150 adult patients with end-stage heart failure were enrolled: 26 subjects in Group 1, 74 in Group 2, and 50 in Group 3. Nineteen patients (73%) in Group 1, 51 (69%) in Group 2, and 36 (72%) in Group 3 were discharged. During follow-up, 22 patients underwent transplantation, while in 3 patients the LVAD was explanted. The overall 1-year survival was 58 ± 10%, 64 ± 6%, and 74% ± 7% in Groups 1, 2, and 3, respectively (p = 0.034). The competing-risks-adjusted cumulative incidence rate for adverse events was 42.1 [27-62.7] per 100 patient-years in Group 1, 35.4 [25.3-48.2] in Group 2, and 22.1 [12.4-36.4] in Group 3 (p = 0.046 for Group 1 vs. 3). CONCLUSIONS: The association of the modern cone-bearing configuration of Jarvik 2000 and minimally invasive surgery improved survival and minimized the risk for cardiovascular events, as a result of combining technology and technique.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Adulto , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Insuficiência Cardíaca/cirurgia , Sistema de Registros , Tecnologia , Resultado do Tratamento
4.
J Card Surg ; 37(12): 5411-5417, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36403259

RESUMO

OBJECTIVES: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. METHODS: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. RESULTS: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%-6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%-3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%-0.7% and Perceval 0%-1%), endocarditis (Intuity 0.2%-0.7% and Perceval 1.6%-6.6%), stroke (Intuity 0.36%-1.4% and Perceval 0%-0.8%), MI (Intuity 0.07%-0.26%), and SVD (Intuity 0.12%-0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%-2.1% for SFS. Hospital costs outcomes ranged from $37,187-$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. CONCLUSIONS: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Transpl Infect Dis ; 23(1): e13428, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32743882

RESUMO

BACKGROUND: The risk of COVID-19 is expected to be higher among solid organ transplant. The aim of the present study was to evaluate the incidence of COVID-19 and the impact of the SARS-CoV-2 outbreak on the personal hygiene and expectations in heart and lung transplant recipients. METHODS: A telephone survey of heart (n = 69) and lung (n = 41) transplant patients and a group of controls (n = 41) was conducted concerning personal hygiene before and after the outbreak; the impact on subjective expectations regarding graft outcome; symptoms possibly associated with SARS-CoV-2 infection; and diagnosis of COVID-19. RESULTS: Seventy nine percent of the patients declared they increased the use of face masks and handwash. Behavior at home regarding self-isolation did not change. About half the patients said they were afraid of the virus. A higher percentage of Lung transplant (LTX) were convinced that SARS-CoV-2 could have a negative impact on the outcome of their graft. 28% declared that they were afraid to come to the hospital for routine examinations and asked to postpone. Nine LTX and five Heart transplant (HTX) patients experienced symptoms that could have been associated with SARS-CoV-2 infection, but none of them underwent a nasopharyngeal swab. Only one LTX was diagnosed with the infection. CONCLUSIONS: In our study, we observed a low incidence of COVID-19 in heart and lung transplant patients (0.9%), similar to that of the general population of our Region. Isolation measures were already observed before the pandemic and were further strengthened in most cases. Particular attention should also be paid to new psychological and physical complications indirectly linked to the COVID-19 pandemic.


Assuntos
COVID-19/complicações , Desinfecção das Mãos , Transplante de Coração-Pulmão , Máscaras , Preferência do Paciente , SARS-CoV-2 , Adulto , Estudos de Casos e Controles , Controle de Doenças Transmissíveis , Coleta de Dados , Feminino , Luvas Cirúrgicas , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade
6.
Artif Organs ; 45(3): 236-243, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32860268

RESUMO

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/efeitos adversos , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Aorta/fisiopatologia , Aorta/cirurgia , Creatinina/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Hemólise/fisiologia , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Resultado do Tratamento
7.
J Clin Ultrasound ; 46(1): 32-40, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28949022

RESUMO

PURPOSE: We aimed to assess the relationship between mitral regurgitation (MR) severity, symptoms, and left atrial (LA) structure and function, before and after mitral valve repair (MVR). METHODS: Global peak atrial longitudinal strain (PALS) was evaluated in 37 patients with severe symptomatic MR and preserved left ventricular (LV) ejection fraction (60.4% ± 4.6%) before and 3 months after MVR and was compared with values from 30 age- and gender-matched controls. RESULTS: Before surgery, PALS was worse in patients than in controls and indexed LA volume was greater (P < .0001 for both). After MVR, PALS deteriorated further and LA volume decreased (P = .001 and P = .05, respectively) as did LV ejection fraction, longitudinal strain (P = .05 and P < .001, respectively), and LV mass (P < .0001). Before surgery, LA volume correlated modestly with LV end-diastolic volume (R = 0.51; P = .01); effective regurgitant orifice area (EROA) correlated with PALS (R = -0.69, P < .001) and with LV longitudinal strain (R = 0.54, P = .01), and New York Heart Association class correlated with PALS (R = -0.69, P < .001), EROA (R = 0.69, P < .001), and LA volume (R = 0.51, P = .04). LA volume was the strongest predictor of global PALS reduction (P < .001), whereas global PALS was the main predictor of postoperative atrial fibrillation (AF) (P < .001). CONCLUSIONS: In patients with severe MR, EROA correlate with symptoms and LA PALS, which itself predicts the occurrence of postoperative AF. Strain values were superior to 2D data for the prediction of postoperative AF.


Assuntos
Coração/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Função do Átrio Esquerdo , Procedimentos Cirúrgicos Cardíacos , Estudos de Casos e Controles , Ecocardiografia , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem
8.
J Heart Valve Dis ; 26(2): 234-236, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28820558

RESUMO

In Europe, mitral regurgitation (MR) is the second most common form of valvular heart disease requiring surgical treatment. The case is presented of a 36-year-old woman with end-stage heart failure secondary to chemotherapy-induced cardiotoxicity, complicated by severe MR. She was listed for heart transplantation and underwent percutaneous MitraClip® implantation in order to preclude further clinical deterioration while awaiting a suitable donor. The one-year follow-up showed a strong improvement of symptoms and mostly reverse left ventricular remodelling, with consequent removal from the heart transplantation list. Video 1: Four-chamber view at baseline. Video 2: Four-chamber view at one-year follow up. Video 3: Tricuspid regurgitation and right ventricle at baseline. Video 4: Tricuspid regurgitation and right ventricle at one-year follow up.


Assuntos
Antibióticos Antineoplásicos/efeitos adversos , Cateterismo Cardíaco/instrumentação , Doxorrubicina/efeitos adversos , Insuficiência Cardíaca/terapia , Transplante de Coração , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Adulto , Ecocardiografia , Feminino , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Listas de Espera
9.
J Card Fail ; 22(11): 901-907, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26952240

RESUMO

PURPOSE: To evaluate potential relationships between different components of left ventricular (LV) function and histopathological evidence for myocardial fibrosis in patients undergoing heart transplantation. METHODS: The study population included patients with advanced heart failure, referred for an echocardiographic examination before heart transplantation. Traditional LV function measurements and global longitudinal strain (GLS) by speckle tracking echocardiography, averaging all LV segments in 4-, 2-, and 3-chamber views were obtained in all subjects. LV tissue samples were obtained from all patients who underwent heart transplantation. Myocardial fibrosis was assessed using Masson's staining. RESULTS: Of 106 patients referred for cardiac transplantation, 47 underwent cardiac transplantation and were enrolled in the study. LV myocardial fibrosis and its grade strongly correlated with GLS (r = 0.75, P = .0001), modestly with global circumferential strain and LV torsion (r = 0.61, P = .001 and r = 0.52, P = .01, respectively) and weakly with mitral S' wave (r = -0.41; P = .01) and mitral annular plane systolic excursion (r = -0.35; P = .05) but did not correlate with LV ejection fraction (r = -0.12; P = NS). GLS had the strongest accuracy for detecting LV fibrosis (area under the curve, 0.92). None of the echo parameters correlated with patient's exercise capacity. CONCLUSION: Global longitudinal strain is the most accurate LV global function measure that correlates with the extent of myocardial fibrosis in patients with advanced systolic HF requiring heart transplantation.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Interpretação de Imagem Assistida por Computador , Miocárdio/patologia , Disfunção Ventricular Esquerda/epidemiologia , Idoso , Biópsia por Agulha , Estudos de Coortes , Comorbidade , Bases de Dados Factuais , Ecocardiografia/métodos , Feminino , Fibrose/diagnóstico por imagem , Fibrose/epidemiologia , Fibrose/patologia , Fibrose/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Transplante de Coração/mortalidade , Mortalidade Hospitalar , Humanos , Imuno-Histoquímica , Itália , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Análise de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/cirurgia
10.
Cardiovasc Ultrasound ; 12: 20, 2014 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-24935114

RESUMO

BACKGROUND: Heart transplantation is limited by severe donor organ shortage. Regardless of the changes made in the acceptance of marginal donors, any such mechanism cannot be considered successful unless recipient graft survival rates remain acceptable. A stress echo-driven selection of donors has proven successful in older donors with normal left ventricular resting function and in standard donors with reversible resting left ventricular dysfunction acutely improving during stress, or slowly improving (over hours) during intensive hormonal treatment. Aim of this study is to assess the medium-term outcome of recipients of marginal donor hearts selected with new echocardiographic techniques over standard criteria. METHODS AND RESULTS: We enrolled 43 recipients of marginal donor hearts: age > 55 years, or < 55 years but with concomitant risk factors, n = 32; acutely improving during stress, n = 3; or slowly improving during hormonal treatment, n = 8. At follow-up (median, 30 months; interquartile range, 21-52 months), 37 of the recipients were still alive. One-year survival was 93%. CONCLUSION: The strict use of new stress-echocardiographic techniques over standard criteria of marginal donor management, together with comprehensive monitoring of the donor, has the potential to substantially increase the number of donor hearts without adverse effects on recipient medium-term outcome.


Assuntos
Ecocardiografia sob Estresse/métodos , Transplante de Coração/mortalidade , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Idoso , Angiografia Coronária , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Doadores de Tecidos , Obtenção de Tecidos e Órgãos , Resultado do Tratamento
11.
Diagnostics (Basel) ; 14(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38893722

RESUMO

BACKGROUND: An increasing proportion of heart failure (HF) patients progress to the advanced stage (AdHF) with high event rates and limited treatment options. Echocardiography, particularly Speckle Tracking-derived myocardial work (MW), is useful for HF diagnosis and prognosis. We aimed to assess MW's feasibility in the prognostic stratification of AdHF. METHODS: We retrospectively screened patients with AdHF who accessed our hospital in 2018-2022. We excluded subjects with inadequate acoustic windows; unavailable brachial artery cuff pressure at the time of the echocardiography; atrial fibrillation; and mitral or aortic regurgitation. We measured standard parameters and left ventricular (LV) strain (LS) and MW. The population was followed up to determine the composite outcomes of all-cause mortality, left ventricular assist device implantation and heart transplantation (primary endpoint), as well as unplanned HF hospitalization (secondary endpoint). RESULTS: We enrolled 138 patients, prevalently males (79.7%), with a median age of 58 years (IQR 50-62). AdHF etiology was predominantly non-ischemic (65.9%). Thirty-five patients developed a composite event during a median follow-up of 636 days (IQR 323-868). Diastolic function, pulmonary pressures, and LV GLS and LV MW indices were not associated with major events. Contrarily, for the secondary endpoint, the hazard ratio for each increase in global work index (GWI) by 50 mmHg% was 0.90 (p = 0.025) and for each increase in global constructive work (GCW) by 50 mmHg% was 0.90 (p = 0.022). Kaplan-Meier demonstrated better endpoint-free survival, with an LV GWI ≥ 369 mmHg%. CONCLUSIONS: GWI and GCW, with good feasibility, can help in the better characterization of patients with AdHF at higher risk of HF hospitalization and adverse events, identifying the need for closer follow-up or additional HF therapy.

12.
Eur Heart J Cardiovasc Imaging ; 25(4): 446-453, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38109280

RESUMO

AIMS: Advanced heart failure (AdHF) is characterized by variable degrees of left ventricular (LV) dysfunction, myocardial fibrosis, and raised filling pressures which lead to left atrial (LA) dilatation and cavity dysfunction. This study investigated the relationship between LA peak atrial longitudinal strain (PALS), assessed by speckle-tracking echocardiography (STE), and invasive measures of LV filling pressures and fibrosis in a group of AdHF patients undergoing heart transplantation (HTX). METHODS AND RESULTS: We consecutively enrolled patients with AdHF who underwent HTX at our Department. Demographic and basic echocardiographic data were registered, then invasive intracardiac pressures were obtained from right heart catheterization, and STE was also performed. After HTX, biopsy specimens from explanted hearts were collected to quantify the degree of LV myocardial fibrosis. Sixty-four patients were included in the study (mean age 62.5 ± 11 years, 42% female). The mean LV ejection fraction (LVEF) was 26.7 ± 6.1%, global PALS was 9.65 ± 4.5%, and mean pulmonary capillary wedge pressure (PCWP) was 18.8 ± 4.8 mmHg. Seventy-three % of patients proved to have severe LV fibrosis. Global PALS was inversely correlated with PCWP (R = -0.83; P < 0.0001) and with LV fibrosis severity (R = -0.78; P < 0.0001) but did not correlate with LVEF (R = 0.15; P = 0.2). Among echocardiographic indices of LV filling pressures, global PALS proved the strongest [area under the curve 0.955 (95% confidence interval 0.87-0.99)] predictor of raised (>18 mmHg) PCWP. CONCLUSION: In patients with AdHF, reduced global PALS strongly correlated with the invasively assessed LV filling pressure and degree of LV fibrosis. Such relationship could be used as non-invasive indicator for optimum patient stratification for therapeutic strategies.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Função do Átrio Esquerdo , Função Ventricular Esquerda , Ventrículos do Coração , Volume Sistólico , Fibrose
13.
Pharmacology ; 92(5-6): 281-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24296902

RESUMO

OBJECTIVES: The dual endothelin receptor antagonist bosentan improves pulmonary vascular resistance (PVR) in patients with primary pulmonary hypertension (PH). The effects of bosentan on secondary PH due to systolic heart failure (HF) are not well defined. This study evaluates the effect and tolerability of bosentan in patients with PH secondary to HF. METHODS: Seventeen adult HF patients with PH and New York Heart Association class III-IV symptoms were treated with bosentan, 62.5 mg twice daily, for 1 month, which was gradually increased to 125 mg twice daily thereafter. Right heart catheterization (RHC), a clinical evaluation and echocardiographic measurements were performed at baseline and at 4 ± 3 (mean ± SD) months of follow-up. Response to bosentan was defined as an improvement in clinical, echocardiographic and RHC parameters. RESULTS: Six patients did not complete the study (therapy was discontinued due to hypotension, elevated liver enzymes or acute decompensation of HF), 11 patients completed the follow-up; 9 patients responded to therapy. Systemic arterial pressures, pulmonary pressures, PVR and the transpulmonary gradient significantly decreased compared with baseline levels in 9 responders (p = 0.05, 0.05, 0.01 and 0.004, respectively), and 4 became eligible for heart transplantation and 3 for left ventricular assist device implantation. CONCLUSIONS: Bosentan decreased pulmonary pressures and PVR in the majority of patients with PH secondary to systolic HF, thereby allowing them to be considered candidates for heart transplantation.


Assuntos
Anti-Hipertensivos/uso terapêutico , Insuficiência Cardíaca Sistólica/complicações , Hipertensão Pulmonar/tratamento farmacológico , Sulfonamidas/uso terapêutico , Bosentana , Cateterismo Cardíaco/métodos , Ecocardiografia , Antagonistas dos Receptores de Endotelina , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/etiologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Resistência Vascular/efeitos dos fármacos
14.
Eur Heart J Cardiovasc Imaging ; 25(1): 105-115, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37542478

RESUMO

AIMS: Right heart failure (RHF) after left ventricular assist device (LVAD) implant is burdened by high morbidity and mortality rates and should be prevented by appropriate patient selection. Adequate right ventricular function is of paramount importance but its assessment is complex and cannot disregard afterload. Myocardial work (MW) is a non-invasive Speckle Tracking Echocardiography-derived method to estimate pressure-volume loops. The aim of this study was to evaluate the performance of right ventricular myocardial work to predict RHF and long-term mortality after LVAD implant. METHODS AND RESULTS: Consecutive patients from May 2017 to February 2022 undergoing LVAD implant were retrospectively reviewed. Patients without a useful echocardiographic exam prior to LVAD implant were excluded. MW analysis was performed. The primary endpoints were early RHF (<30 days from LVAD implant) and death at latest available follow-up. We included 23 patients (mean age 64 ± 8 years, 91% men). Median follow-up was 339 days (IQR: 30-1143). Early RHF occurred in six patients (26%). A lower right ventricular global work efficiency [RVGWE, OR 0.86, 95% confidence intervals (CI) 0.76-0.97, P = 0.014] was associated with the occurrence of early RHF. Among MW indices, the performance for early RHF prediction was greatest for RVGWE [area under the curve (AUC) 0.92] and a cut-off of 77% had a 100% sensitivity and 82% specificity. At long-term follow-up, death occurred in 4 of 14 patients (28.6%) in the RVGWE > 77% group and in 6 of 9 patients (66.7%) in the RVGWE < 77% group (HR 0.25, 95% CI 0.07-0.90, P = 0.033). CONCLUSION: RVGWE was a predictor of early RHF after LVAD implant and brought prognostic value in terms of long-term mortality.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/epidemiologia , Prognóstico , Ecocardiografia , Disfunção Ventricular Direita/diagnóstico por imagem
15.
ESC Heart Fail ; 10(5): 2853-2864, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37415291

RESUMO

AIMS: The presence of anti-human leucocyte antigen (HLA) antibodies has been implicated in a higher incidence of complications as well as mortality rate in heart transplantation. The aim of the study was to identify through non-invasive parameters early signs of myocardial dysfunction in the presence of anti-HLA antibodies but without evidence of antibody-mediated rejection (AMR) and its possible prognostic impact. METHODS AND RESULTS: A total of 113 heart-transplanted patients without acute cellular rejection (ACR) and AMR or cardiac allograft vasculopathy (CAV) were prospectively enrolled and divided into two groups ['HLA+' (50 patients) and 'HLA-' (63 patients)], based on the presence of anti-HLA antibodies. Each patient was followed for 2 years after the enrolment, recording episodes of AMR, ACR, CAV, and mortality. Clinical characteristics were similar between the two groups. Among laboratory data, N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin values were significantly higher in the presence of anti-HLA antibodies (P < 0.001 and P = 0.003, respectively). The echocardiographic parameters that showed a statistically significant difference between the two groups were deceleration time of E wave (DecT E, P < 0.001), left ventricular global longitudinal strain (P < 0.001), tricuspid annular plane systolic excursion (P = 0.011), tricuspid S' wave (P = 0.002), and free wall right ventricular longitudinal strain (fwRVLS, P = 0.027), whereas left atrial strain did not differ significantly (P = 0.408). Univariate analysis showed that anti-HLA antibodies were associated with the development of CAV at both 1 and 2 year follow-up [odds ratio (OR) 11.90, 95% confidence interval (CI) 1.43-90.79, P = 0.022 and OR 3.37, 95% CI 1.78-9.67, P = 0.024, respectively]. Bivariate analysis demonstrated that both fwRVLS and DecT E were predictors of CAV development independently from HLA status. CONCLUSIONS: The presence of circulating anti-HLA antibodies is correlated with a mild cardiac dysfunction, even in the absence of AMR, and CAV development. Interestingly, reduced values of DecT E and fwRVLS were predictors of future development of CAV, independently from anti-HLA antibody.


Assuntos
Transplante de Coração , Humanos , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Anticorpos , Prognóstico , Rejeição de Enxerto/diagnóstico , Ecocardiografia
16.
Diagnostics (Basel) ; 13(16)2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37627879

RESUMO

BACKGROUND: The hemodynamic definition of PH has recently been revised with unchanged threshold of peak tricuspid regurgitation velocity (TRV). The aim of this study was to evaluate the predictive accuracy of peak TRV for PH based on the new (>20 mmHg) and the old (>25 mmHg) cut-off value for mean pulmonary artery pressure (mPAP) and to compare it with the mean right ventricular-right atrial (RV-RA) pressure gradient. METHODS: Patients with advanced heart failure were screened from 2016 to 2021. The exclusion criteria were absent right heart catheterization (RHC) results, chronic obstructive pulmonary disease, any septal defect, inadequate acoustic window or undetectable TR. The mean RV-RA gradient was calculated from the velocity-time integral of TR. RESULTS: The study included 41 patients; 34 (82.9%) had mPAP > 20 mmHg and 24 (58.5%) had mPAP > 25 mmHg. The AUC for the prediction of PH with mPAP > 20 mmHg was 0.855 for peak TRV and mean RV-RA gradient was 0.811. AUC for the prediction of PH defined as mPAP > 25 mmHg for peak TRV was 0.860 and for mean RV-RA gradient was 0.830. A cutoff value of 2.4 m/s for peak TRV had 65% sensitivity and 100% positive predictive value for predicting PH according to the new definition. CONCLUSIONS: Peak TRV performed better than mean RV-RA pressure gradient in predicting PH irrespective of hemodynamic definitions. Peak TRV performed similarly with the two definitions of PH, but a lower cutoff value had higher sensitivity and equal positive predictive value for PH.

17.
J Clin Med ; 12(10)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37240611

RESUMO

Background: The gold-standard treatment for end-stage heart failure is heart transplantation, but the lack of organ donors remains an important limitation in this field. An accurate selection of marginal hearts is fundamental to increase organ availability. Purpose: In our study we analyzed if recipients receiving marginal donor (MD) hearts, selected by dipyridamole stress echocardiography according to the ADOHERS national protocol, had different outcomes compared to recipients with acceptable donor (AD) hearts. Methods: Data were collected and retrospectively analyzed from patients who received an orthotopic heart transplant at our institution between 2006 and 2014. Dipyridamole stress echo was performed on identified marginal donors and selected hearts were eventually transplanted. Clinical, laboratory and instrumental features of the recipients were evaluated and patients with homogenous baseline characteristics were selected. Results: Eleven recipients transplanted with a selected marginal heart and eleven recipients transplanted with an acceptable heart were included. Mean donor age was 41 ± 23. The median follow-up was 113 months (IQR 86-146 months). Age, cardiovascular risk and morpho-functional characteristics of the left ventricle were comparable between the two populations (p > 0.05). Left atrial size was significantly higher in patients with marginal hearts (acceptable atrial volume: 23 ± 5 mL; marginal atrial volume: 38 ± 5 mL; p = 0.003). Acceptable donor recipients showed a higher impact of Cardiac Allograph Vasculopathy (p = 0.019). No rejection differences were found between the two groups. Four patients deceased, three were standard donor recipients and one was from the marginal donor group. Conclusions: Our study shows how cardiac transplant (Htx) from selected marginal donor hearts through a non-invasive bedside technique can alleviate the shortage of organs without a difference in survival compared to acceptable donor hearts.

18.
ESC Heart Fail ; 10(4): 2607-2620, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37345220

RESUMO

AIMS: Mechanical circulatory support (MCS) systems are increasingly employed in cardiogenic shock and advanced heart failure. A thorough understanding of the complex interactions occurring among heart, vasculature, and device is essential to optimize patient's management. The aim of this study is to explore non-invasive haemodynamic profiling of patients undergoing MCS based on pressure-strain (PS) analysis. METHODS: Clinical and echocardiographic data from consecutive patients undergoing different MCS systems positioning/implantation admitted to the third level cardiological intensive care unit of Siena Hospital from August 2021 to November 2021 were retrospectively reviewed. Patients without a useful echocardiographic exam or without arterial blood pressure recording at the time of echocardiography were excluded. Myocardial work analysis was performed in the included patients. RESULTS: We reviewed 18 patients, of which nine were excluded. Included patients were three patients with intra-aortic balloon pump (IABP), two patients with durable left ventricular assist device (dLVAD), two patients with Impella®, one patient with extracorporeal membrane oxygenation (ECMO), and one patient with ECMO and IABP. Myocardial work analysis was feasible in each included patient. The use of IABP shifted the PS curve rightward and downward. Global work index (GWI) and global wasted work (GWW) decreased after IABP positioning, whereas global work efficiency (GWE) increased. The use of continuous-flow pumps, whether temporaneous (Impella®) or long term (dLVAD), induced a change in the PS loop morphology, with a shift towards a triangular shape. ECMO positioning alone resulted in a narrowing of the PS loop, with a decrease in GWI and GWE and an increase in GWW and mean arterial pressure. The combined used of IABP with ECMO widened the PS loop and improved GWI and GWE. CONCLUSIONS: PS loops analysis in patients undergoing MCS seems to be feasible and may unveil MCS-induced haemodynamic variations. Myocardial work could be used to monitor ventricular-arterial-device coupling and guide tailored MCS management.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Choque Cardiogênico/terapia , Insuficiência Cardíaca/terapia , Hemodinâmica
19.
J Card Fail ; 18(3): 208-15, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22385941

RESUMO

BACKGROUND: Right ventricular (RV) systolic function has a critical role in determining the clinical outcome and success of using left ventricular assist devices (LVADs) in patients with refractory heart failure. Tissue Doppler and M-mode measurements of tricuspid systolic motion (tricuspid S' and tricuspid annular plane systolic excursion [TAPSE]) are the most currently used methods for the quantification of RV longitudinal function; RV deformation analysis by speckle-tracking echocardiography (STE) has recently allowed the analysis of global RV longitudinal function. Using cardiac catheterization as the reference standard, this study aimed at exploring the correlation between RV longitudinal function by STE and RV stroke work index (RVSWI) in patients referred for cardiac transplantation. METHODS AND RESULTS: Right-side heart catheterization and transthoracic echo Doppler were simultaneously performed in 41 patients referred for cardiac transplantation evaluation for advanced systolic heart failure. Thermodilution RV stroke volume and invasive pulmonary pressures were used to obtain RVSWI. RV longitudinal strain (RVLS) by STE was assessed averaging all segments in apical 4-chamber view (global RVLS) and by averaging RV free-wall segments (free-wall RVLS). Tricuspid S' and TAPSE were also calculated. No significant correlations were found for TAPSE or tricuspid S' with RVSWI (r = 0.14; r = 0.06; respectively). Close negative correlations between global RVLS and free-wall RVLS with the RVSWI were found (r = -0.75; r = -0.82; respectively; both P < .0001). Furthermore, free-wall RVLS demonstrated the highest diagnostic accuracy (area under the receiver operating characteristic (ROC) curve 0.90) and good sensitivity and specificity of 92% and 86%, respectively, to predict depressed RVSWI using a cutoff value of less than -11.8%. CONCLUSIONS: In a group of patients referred for heart transplantation, TAPSE and tricuspid S' did not correlate with invasively obtained RVSWI. RV longitudinal deformation analysis by STE correlated well with RVSWI, providing a better estimation of RV systolic performance.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Volume Sistólico , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta , Índice de Gravidade de Doença , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/cirurgia
20.
J Clin Ultrasound ; 40(7): 451-4, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22287493

RESUMO

A 44-year-old woman, who had undergone orthotopic cardiac transplantation in 1999, presented acute allograft rejection 4 months after childbirth. Analysis of myocardial deformation by speckle tracking echocardiography showed, in contrast with traditional markers of systolic function, a strong reduction of left ventricular strain, which recovered, together with rejection, under pharmacological treatment. This case documents the potential advantages of speckle tracking echocardiography in the noninvasive management of transplant recipients.


Assuntos
Ecocardiografia/métodos , Rejeição de Enxerto/diagnóstico por imagem , Transplante de Coração/imunologia , Adulto , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA