Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Appl Clin Med Phys ; 24(2): e13870, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36519622

RESUMO

PURPOSE: This work investigates the impact of tissue-equivalent attenuator choice on measured signal-to-noise ratio (SNR) for automatic exposure control (AEC) performance evaluation in digital mammography. It also investigates how the SNR changes for each material when used to evaluate AEC performance across different mammography systems. METHODS: AEC performance was evaluated for four mammography systems using seven attenuator sets at two thicknesses (4 and 8 cm). All systems were evaluated in 2D imaging mode, and one system was evaluated in digital breast tomosynthesis (DBT) mode. The methodology followed the 2018 ACR digital mammography quality control (DMQC) manual. Each system-attenuator-thickness combination was evaluated using For Processing images in ImageJ with standard ROI size and location. The closest annual physicist testing results were used to explore the impact of varying measured AEC performance on image quality. RESULTS: The measured SNR varied by 44%-54% within each system across all attenuators at 4 cm thickness in 2D mode. The variation appeared to be largely due to changes in measured noise, with variations of 46%-67% within each system across all attenuators at 4 cm thickness in 2D mode. Two systems had failing SNR levels for two of the materials using the minimum SNR criterion specified in the ACR DMQC manual. Similar trends were seen in DBT mode and at 8 cm thickness. Within each material, there was 115%-131% variation at 4 cm and 82%-114% variation at 8 cm in the measured SNR across the four imaging systems. Variation in SNR did not correlate with system operating level based on visual image quality and average glandular dose (AGD). CONCLUSION: Choice of tissue-equivalent attenuator for AEC performance evaluation affects measured SNR values. Depending on the material, the difference may be enough to result in failure following the longitudinal and absolute thresholds specified in the ACR DMQC manual.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Humanos , Imagens de Fantasmas , Mamografia/métodos , Razão Sinal-Ruído , Controle de Qualidade , Intensificação de Imagem Radiográfica/métodos
2.
Magn Reson Med ; 87(4): 1742-1757, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34775638

RESUMO

PURPOSE: To introduce proton density water fraction (PDWF) as a confounder-corrected (CC) MR-based biomarker of mammographic breast density, a known risk factor for breast cancer. METHODS: Chemical shift encoded (CSE) MR images were acquired using a low flip angle to provide proton density contrast from multiple echo times. Fat and water images, corrected for known biases, were produced by a six-echo CC CSE-MRI algorithm. Fibroglandular tissue (FGT) volume was calculated from whole-breast segmented PDWF maps at 1.5T and 3T. The method was evaluated in (1) a physical fat-water phantom and (2) normal volunteers. Results from two- and three-echo CSE-MRI methods were included for comparison. RESULTS: Six-echo CC-CSE-MRI produced unbiased estimates of the total water volume in the phantom (mean bias 3.3%) and was reproducible across protocol changes (repeatability coefficient [RC] = 14.8 cm3 and 13.97 cm3 at 1.5T and 3.0T, respectively) and field strengths (RC = 51.7 cm3 ) in volunteers, while the two- and three-echo CSE-MRI approaches produced biased results in phantoms (mean bias 30.7% and 10.4%) that was less reproducible across field strengths in volunteers (RC = 82.3 cm3 and 126.3 cm3 ). Significant differences in measured FGT volume were found between the six-echo CC-CSE-MRI and the two- and three-echo CSE-MRI approaches (p = 0.002 and p = 0.001, respectively). CONCLUSION: The use of six-echo CC-CSE-MRI to create unbiased PDWF maps that reproducibly quantify FGT in the breast is demonstrated. Further studies are needed to correlate this quantitative MR biomarker for breast density with mammography and overall risk for breast cancer.


Assuntos
Densidade da Mama , Prótons , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Água
3.
Magn Reson Med ; 84(1): 25-38, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31814173

RESUMO

PURPOSE: A multiecho, field of view (FOV)-oversampled k-t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least-squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low-SNR (signal-to-noise-ratio) species, local uncertainties in metabolite peaks, and echo-to-echo signal inconsistencies. THEORY: k-t spiral acquisitions redistribute readout points to be more densely spaced radially in k-space by acquiring an FOV and matrix that are oversampled by η. These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross-talk to better resolve 13 C-labeled species for spectroscopic imaging. METHODS: Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k-t spiral acquisitions. Image spectral cross-talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k-t spiral [1-13 C]pyruvate MRSI to reduce spectral cross-talk for 3 scenarios of different expected reconstruction stability. RESULTS: Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross-talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross-talk in lactate images acquired with η = 7 versus η = 1. CONCLUSION: The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low-SNR species, local uncertainties in metabolite resonances, and echo-to-echo signal inconsistencies can be improved with the use of FOV-oversampled k-t spiral acquisitions.


Assuntos
Imageamento por Ressonância Magnética , Ácido Pirúvico , Algoritmos , Animais , Isótopos de Carbono , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Camundongos , Imagens de Fantasmas
4.
Magn Reson Med ; 81(5): 3379-3391, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30652350

RESUMO

PURPOSE: Fluorescence lifetime imaging microscopy (FLIM) of endogenous fluorescent metabolites permits the measurement of cellular metabolism in cell, tissue and animal models. In parallel, magnetic resonance spectroscopy (MRS) of dynamic nuclear (hyper)polarized (DNP) 13 C-pyruvate enables measurement of metabolism at larger in vivo scales. Presented here are the design and initial application of a bioreactor that connects these 2 metabolic imaging modalities in vitro, using 3D cell cultures. METHODS: The model fitting for FLIM data analysis and the theory behind a model for the diffusion of pyruvate into a collagen gel are detailed. The device is MRI-compatible, including an optical window, a temperature control system and an injection port for the introduction of contrast agents. Three-dimensional printing, computer numerical control machining and laser cutting were used to fabricate custom parts. RESULTS: Performance of the bioreactor is demonstrated for 4 T1 murine breast cancer cells under glucose deprivation. Mean nicotinamide adenine dinucleotide (NADH) fluorescence lifetimes were 10% longer and hyperpolarized 13 C lactate:pyruvate (Lac:Pyr) ratios were 60% lower for glucose-deprived 4 T1 cells compared to 4 T1 cells in normal medium. Looking at the individual components of the NADH fluorescent lifetime, τ1 (free NADH) showed no significant change, while τ2 (bound NADH) showed a significant increase, suggesting that the increase in mean lifetime was due to a change in bound NADH. CONCLUSION: A novel bioreactor that is compatible with, and can exploit the benefits of, both FLIM and 13 C MRS in 3D cell cultures for studies of cell metabolism has been designed and applied.


Assuntos
Reatores Biológicos , Espectroscopia de Ressonância Magnética , Imagem Óptica , Animais , Linhagem Celular Tumoral , Sobrevivência Celular , Colágeno/química , Meios de Contraste , Difusão , Progressão da Doença , Desenho de Equipamento , Feminino , Géis , Glucose/metabolismo , Ácido Láctico/metabolismo , Neoplasias Mamárias Animais/diagnóstico por imagem , Neoplasias Mamárias Experimentais/diagnóstico por imagem , Camundongos , NAD/farmacologia , Impressão Tridimensional , Ácido Pirúvico/química , Temperatura
5.
Eur J Radiol ; 166: 110998, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37506475

RESUMO

PURPOSE: To evaluate the utility of the PI-QUAL score in assessing protocol changes aimed to improve image quality from a non-endorectal coil prostate MR imaging protocol during a 9-month quality improvement (QI) project and to quantify the inter-reader agreement of PI-QUAL scores between radiologists, technologists, and physicists. METHODS: This retrospective study audited 1,012 multiparametric prostate MRI examinations as part of a national QI project according to the PI-QUAL standard. PI-QUAL scores were used to inform MR protocol changes. Following the project, 4 radiologists, 2 technologists, and 1 medical physicist collectively audited an additional set of 150 examinations to identify statistical improvements in image quality using the two-tailed Wilcoxon rank sum test. The improvements due to individual protocol changes were assessed among subsets of the 1,012 examinations which compared examinations occurring before and after the isolated protocol change. Inter-reader variability was assessed using the percent majority agreement and the average standard deviation of PI-QUAL scores between evaluators. RESULTS: During this QI project, PI-QUAL scores improved from 3.67 ± 0.75 to 4.16 ± 0.59 (p < 0.01) after implementing a series of protocol changes. Among a subset of 451 cases, we found that adopting R/L rather than A/P phase encoding reduced distortion in diffusion-weighted imaging (DW) from 21.6% (41/190 A/P phase encoded cases) to 11.5% (30/261 R/L phase encoded cases) (p < 0.01). Similarly, in the same 451 cases, adopting R/L phase encoding in T2WI reduced breathing motion artifacts from 34.6% (94/272 A/P phase encoding cases) to 12.8% (23/179 R/L phase encoding cases) (p < 0.01). DWI wraparound artifact was mitigated by employing a full-pelvis shim and enabling the abdomen shim option. The occurrence of low signal-to-noise ratio was reduced from 19.4% (19/98 cases without a weight-based threshold) to 6.3% (10/160) by instituting a weight-based threshold for using an endorectal coil (p < 0.01). The percent majority agreement was similar between radiologists, technologists and physicists, and all evaluators combined (72%, 77%, and 67%, respectively). CONCLUSIONS: PI-QUAL can evaluate image quality changes resulting from protocol optimizations at both the exam- and series-levels. With training, radiologists, technologists, and physicists can perform PI-QUAL scoring with similar performance. Broadening the scope of the quality improvement team can result in meaningful and lasting change.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Pelve , Equipe de Assistência ao Paciente
6.
Metabolites ; 11(5)2021 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33925445

RESUMO

This study uses dynamic hyperpolarized [1-13C]pyruvate magnetic resonance spectroscopic imaging (MRSI) to estimate differences in glycolytic metabolism between highly metastatic (4T1, n = 7) and metastatically dormant (4T07, n = 7) murine breast cancer models. The apparent conversion rate of pyruvate-to-lactate (kPL) and lactate-to-pyruvate area-under-the-curve ratio (AUCL/P) were estimated from the metabolite images and compared with biochemical metabolic measures and immunohistochemistry (IHC). A non-significant trend of increasing kPL (p = 0.17) and AUCL/P (p = 0.11) from 4T07 to 4T1 tumors was observed. No significant differences in tumor IHC lactate dehydrogenase-A (LDHA), monocarboxylate transporter-1 (MCT1), cluster of differentiation 31 (CD31), and hypoxia inducible factor-α (HIF-1α), tumor lactate-dehydrogenase (LDH) activity, or blood lactate or glucose levels were found between the two tumor lines. However, AUCL/P was significantly correlated with tumor LDH activity (ρspearman = 0.621, p = 0.027) and blood glucose levels (ρspearman = -0.474, p = 0.042). kPL displayed a similar, non-significant trend for LDH activity (ρspearman = 0.480, p = 0.114) and blood glucose levels (ρspearman = -0.414, p = 0.088). Neither kPL nor AUCL/P were significantly correlated with blood lactate levels or tumor LDHA or MCT1. The significant positive correlation between AUCL/P and tumor LDH activity indicates the potential of AUCL/P as a biomarker of glycolytic metabolism in breast cancer models. However, the lack of a significant difference between in vivo tumor metabolism for the two models suggest similar pyruvate-to-lactate conversion despite differing metastatic potential.

7.
Magn Reson Imaging ; 68: 9-17, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31978518

RESUMO

PURPOSE: The goal of this study was to develop a methodology to investigate the relationship between contractile function and hyperpolarized (HP) [1-13C]pyruvate metabolism in a small animal model. To achieve sufficient signal from HP 13C compounds, HP 13C MRS/MRSI has required relatively large infusion volumes relative to the total blood volume in small animal models, which may affect cardiac function. METHODS: Eight female Sprague Dawley rats were imaged on a 4.7T scanner with a dual tuned 1H/13C volume coil. ECG and respiratory gated k-t spiral MRSI and an IDEAL based reconstruction to determine [1-13C]pyruvate metabolism in the myocardium. This was coupled with 1H cine MRI to determine ventricular volumes and mechanical function pre- and post-infusion of [1-13C]pyruvate. For comparison to the [1-13C]pyruvate experiments, three female Sprague Dawley rats were imaged with 1H cine MRI to determine myocardial function pre- and post-saline infusion. RESULTS: We demonstrated significant changes in cardiac contractile function between pre- and post-infusion of [1-13C]pyruvate. Specifically, there was an increase in end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF). Additionally, the ventricular vascular coupling ratio (VVCR) showed an improvement after [1-13C]pyruvate infusion, indicating increased systolic performance due to an increased arterial load. There was a moderate to strong relationship between the downstream metabolic conversion of pyruvate to bicarbonate and a strong relationship between the conversion of pyruvate to lactate and the cardiac mechanical function response. CONCLUSION: The infusion of [1-13C]pyruvate resulted in demonstrable increases in contractile function which was related to pyruvate conversion to bicarbonate and lactate. The combined effects of the infusion volume and inotropic effects of pyruvate metabolism likely explains the augmentation in myocardial mechanical function seen in these experiments. Given the relationship between pyruvate metabolism and contractile function observed in this study, this methodological approach may be utilized to better understand cardiac metabolic and functional remodeling in heart disease.


Assuntos
Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Animais , Área Sob a Curva , Bicarbonatos/metabolismo , Isótopos de Carbono , Feminino , Ventrículos do Coração , Ácido Láctico/metabolismo , Ácido Pirúvico/metabolismo , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA