Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 237
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
2.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
3.
Eur Heart J ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39217446

RESUMO

BACKGROUND AND AIMS: Deep learning applied to electrocardiograms (ECG-AI) is an emerging approach for predicting atrial fibrillation or flutter (AF). This study introduces an ECG-AI model developed and tested at a tertiary cardiac centre, comparing its performance with clinical and AF polygenic scores (PGS). METHODS: ECG in sinus rhythm from the Montreal Heart Institute were analysed, excluding those from patients with preexisting AF. The primary outcome was incident AF at 5 years. An ECG-AI model was developed by splitting patients into non-overlapping datasets: 70% for training, 10% for validation, and 20% for testing. Performance of ECG-AI, clinical models and PGS was assessed in the test dataset. The ECG-AI model was externally validated in the Medical Information Mart for Intensive Care-IV (MIMIC-IV) hospital dataset. RESULTS: A total of 669,782 ECGs from 145,323 patients were included. Mean age was 61±15 years, and 58% were male. The primary outcome was observed in 15% of patients and the ECG-AI model showed an area under the receiver operating characteristic curve (AUC) of 0.78. In time-to-event analysis including the first ECG, ECG-AI inference of high risk identified 26% of the population with a 4.3-fold increased risk of incident AF (95% confidence interval 4.02-4.57). In a subgroup analysis of 2,301 patients, ECG-AI outperformed CHARGE-AF (AUC=0.62) and PGS (AUC=0.59). Adding PGS and CHARGE-AF to ECG-AI improved goodness-of-fit (likelihood ratio test p<0.001), with minimal changes to the AUC (0.76-0.77). In the external validation cohort (mean age 59±18 years, 47% male, median follow-up 1.1 year) ECG-AI model performance= remained consistent (AUC=0.77). CONCLUSIONS: ECG-AI provides an accurate tool to predict new-onset AF in a tertiary cardiac centre, surpassing clinical and polygenic scores.

4.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
5.
J Cardiovasc Electrophysiol ; 35(10): 2006-2016, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39136311

RESUMO

BACKGROUND: The prevalence and impact of obesity on outcomes of atrial fibrillation (AF) ablation randomized controlled trials (RCTs) have not been well studied. OBJECTIVE: To examine the proportion of participants with obesity enrolled in RCTs of AF ablation and outcomes of ablation when subgroup analysis of participants with obesity were available. METHODS: We systematically searched PubMed and EMBASE for AF ablation RCTs published between January 1, 2015 to May 31, 2022. When body mass index (BMI) data were available, normal distribution was assumed and a z score was used to estimate the proportion of obesity. Results categorized by BMI or body weight status were reviewed. Authors were contacted for additional information. RESULTS: Of 148 eligible RCTs with 30174 participants, 144 (97.30%) RCTs did not report the proportion of participants with obesity, while published information regarding BMI was available in 63.51%. Three trials excluded patients based on BMI. Using reported BMI, we estimated the proportion of participants with obesity varied greatly across these trials, ranging from 5.82%-71.9% (median 38.02%, interquartile 29.64%, 49.10%). Patients with obesity were represented in a greater proportion among trials conducted in North America (50.23%) and Asia (44.72%), compared to others (32.16%), p < .001. Subgroup analysis or analysis adjusting for BMI was reported in only 13 (8.78%) RCTs; four (30.77%) of these suggested that BMI or body weight might negatively affect primary outcomes. CONCLUSION: Obesity is a common comorbidity among AF patients. However, most AF ablation RCTs underreported the proportion of participants with obesity and its impact on the primary outcomes.


Assuntos
Fibrilação Atrial , Índice de Massa Corporal , Ablação por Cateter , Obesidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Obesidade/epidemiologia , Obesidade/diagnóstico , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Masculino , Feminino , Prevalência , Pessoa de Meia-Idade , Fatores de Risco , Idoso , Medição de Risco , Frequência Cardíaca
6.
Europace ; 26(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39073570

RESUMO

Atrial fibrillation (AF) prediction and screening are of important clinical interest because of the potential to prevent serious adverse events. Devices capable of detecting short episodes of arrhythmia are now widely available. Although it has recently been suggested that some high-risk patients with AF detected on implantable devices may benefit from anticoagulation, long-term management remains challenging in lower-risk patients and in those with AF detected on monitors or wearable devices as the development of clinically meaningful arrhythmia burden in this group remains unknown. Identification and prediction of clinically relevant AF is therefore of unprecedented importance to the cardiologic community. Family history and underlying genetic markers are important risk factors for AF. Recent studies suggest a good predictive ability of polygenic risk scores, with a possible additive value to clinical AF prediction scores. Artificial intelligence, enabled by the exponentially increasing computing power and digital data sets, has gained traction in the past decade and is of increasing interest in AF prediction using a single or multiple lead sinus rhythm electrocardiogram. Integrating these novel approaches could help predict AF substrate severity, thereby potentially improving the effectiveness of AF screening and personalizing the management of patients presenting with conditions such as embolic stroke of undetermined source or subclinical AF. This review presents current evidence surrounding deep learning and polygenic risk scores in the prediction of incident AF and provides a futuristic outlook on possible ways of implementing these modalities into clinical practice, while considering current limitations and required areas of improvement.


Assuntos
Fibrilação Atrial , Aprendizado de Máquina , Fibrilação Atrial/genética , Fibrilação Atrial/diagnóstico , Humanos , Medição de Risco , Fatores de Risco , Herança Multifatorial , Valor Preditivo dos Testes , Predisposição Genética para Doença , Eletrocardiografia , Fenótipo
7.
Eur Heart J ; 44(9): 765-776, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36459112

RESUMO

AIMS: Atrial tachyarrhythmia recurrence ≥30 s remains the primary endpoint of clinical trials; however, this definition has not been correlated with clinical outcomes or pathophysiological processes. This study sought to determine the atrial tachyarrhythmia duration and burden associated with meaningful clinical outcomes. METHODS AND RESULTS: The time and duration of every atrial tachyarrhythmia episode recorded on implantable cardiac monitor were evaluated. Healthcare utilization and quality of life in the year following ablation were prospectively collected. Three hundred and forty-six patients provided 126 110 monitoring days. One-year freedom from recurrence increased with arrhythmia duration thresholds, from 52.6 (182/346) to 93.3% (323/346; P < 0.0001). Patients with atrial fibrillation (AF) recurrence limited to durations ≤1 h had rates of healthcare utilization comparable with patients free of recurrence, while patients with AF recurrences lasting >1 h had a relative risk for emergency department consultation of 3.2 [95% confidence interval (CI) 2.0-5.3], hospitalization of 5.3 (95% CI 2.9-9.6), and repeat ablation of 27.1 (95% CI 10.5-71.0). Patients with AF burden of ≤0.1% had rates of healthcare utilization comparable with patients free of recurrence, while patients with AF burden of >0.1% had a relative risk for emergency department consultation of 2.4 (95% CI 1.9-3.9), hospitalization of 6.8 (95% CI 3.6-13.0), cardioversion of 9.1 (95% CI 3.3-25.6), and repeat ablation of 21.8 (95% CI 9.2-52.2). Compared with patients free of recurrence, the disease-specific quality of life was significantly impaired with AF episode durations >24 h, or AF burdens >0.1%. CONCLUSION: AF recurrence, as defined by 30 s of arrhythmia, lacks clinical relevance. AF episode durations >1 h or burdens >0.1% were associated with increased rates of healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Qualidade de Vida , Taquicardia , Aceitação pelo Paciente de Cuidados de Saúde , Ablação por Cateter/métodos , Recidiva
8.
Circulation ; 145(1): 21-30, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34816727

RESUMO

BACKGROUND: Various noninvasive intermittent rhythm monitoring strategies have been used to assess arrhythmia recurrences in trials evaluating pharmacological and invasive therapeutic interventions for atrial fibrillation (AF). We determined whether a frequency and duration of noninvasive rhythm monitoring could be identified that accurately detects arrhythmia recurrences and approximates the AF burden derived from continuous monitoring using an implantable cardiac monitor (ICM). METHODS: The rhythm history of 346 patients enrolled in the CIRCA-DOSE trial (Cryoballoon Versus Contact-Force Irrigated Radiofrequency Catheter Ablation) was reconstructed. Using computer simulations, we evaluated event-free survival, sensitivity, negative predictive value, and AF burden of a range of noninvasive monitoring strategies, including those used in contemporary AF ablation trials. RESULTS: A total of 126 290 monitoring days were included in the analysis. At 12 months, 164 patients experienced atrial arrhythmia recurrence as documented by the ICM (1-year event-free survival, 52.6%). Most noninvasive monitoring strategies used in AF ablation trials had poor sensitivity for detecting arrhythmia recurrence. Sensitivity increased with the intensity of monitoring, with serial (3) short-duration monitors (24-/48-hour ECG monitors) missing a substantial proportion of recurrences (sensitivity, 15.8% [95% CI, 8.9%-20.7%] and 24.5% [95% CI, 16.2%-30.6%], respectively). Serial (3) longer-term monitors (14-day ECG monitors) more closely approximated the gold standard ICM (sensitivity, 64.6% [95% CI, 53.6%-74.3%]). AF burden derived from short-duration monitors significantly overestimated the true AF burden in patients with recurrences. Increasing monitoring duration resulted in improved correlation and concordance between noninvasive estimates of the invasive AF burden (R2 = 0.85 and interclass correlation coefficient = 0.91 for serial [3] 14-day ECG monitors versus ICM). CONCLUSIONS: The observed rate of postablation atrial tachyarrhythmia recurrence is highly dependent on the arrhythmia monitoring strategy employed. Between-trial discrepancies in outcomes may reflect different monitoring protocols. On the basis of measures of agreement, serial long-term (7-14 day) intermittent monitors accumulating at least 28 days of annual monitoring provide estimates of AF burden comparable with ICM. However, ICMs outperform intermittent monitoring for arrhythmia detection, and should be considered the gold standard for clinical trials. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01913522.


Assuntos
Fibrilação Atrial/radioterapia , Ablação por Cateter/métodos , Fibrilação Atrial/mortalidade , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão
9.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32374963

RESUMO

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Reutilização de Equipamento , Infecções/etiologia , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Estudos de Casos e Controles , Países em Desenvolvimento , Feminino , Seguimentos , Humanos , Incidência , Infecções/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Fatores de Risco , Esterilização
10.
Pacing Clin Electrophysiol ; 46(8): 895-903, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37433176

RESUMO

Bi-atrial tachycardia (BiAT) is not rare after extensive atrial ablation or cardiac surgery. The complexity of bi-atrial reentrant circuits poses a great challenge for clinical practice. With recent advances in mapping technologies, we are now able to characterize atrial activation in detail. However, given the involvement of both atria and multiple epicardial conductions, endocardial mapping for BiATs is not easy to understand. Knowledge of the atrial myocardial architecture is the foundation for the clinical management of BiATs; as it is required to understand the possible mechanism of the tachycardia and identify the optimal target of ablation. In this review we summarize current knowledge about the anatomy of interatrial connections as well as other epicardial fibers and discuss the interpretation of electrophysiological findings and ablation strategies for BiATs.

11.
Can Fam Physician ; 69(4): 245-256, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37072207

RESUMO

OBJECTIVE: To support family physicians in preventing atrial fibrillation (AF) in patients at risk and in identifying and managing those with established AF; and to summarize key recommendations for ideal screening and care of patients. SOURCES OF INFORMATION: The 2020 Canadian Cardiovascular Society and Canadian Heart Rhythm Society comprehensive guidelines for the management of AF, based on current evidence and clinical experience related to AF. MAIN MESSAGE: Atrial fibrillation, which is estimated to affect at least 500,000 Canadians, is associated with high risks of stroke, heart failure, and death. Primary care clinicians occupy a central role in the management of this chronic condition, focusing on the challenges of preventing AF and identifying, diagnosing, treating, and following patients with AF. Evidence-based guidelines that provide optimal management strategies have been published by the Canadian Cardiovascular Society and Canadian Heart Rhythm Society to assist in these tasks. Messages critical to primary care are offered to support effective knowledge translation. CONCLUSION: Most patients with AF can be managed effectively in primary care. Family physicians not only play an important role in ensuring patients with AF receive timely diagnoses, but they are also key to providing initial and ongoing care, especially in patients with comorbid conditions.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Canadá , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Doença Crônica , Atenção Primária à Saúde , Anticoagulantes/uso terapêutico
12.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
13.
Lancet ; 395(10221): 339-349, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32007169

RESUMO

BACKGROUND: Acute atrial fibrillation is the most common arrythmia treated in the emergency department. Our primary aim was to compare conversion to sinus rhythm between pharmacological cardioversion followed by electrical cardioversion (drug-shock), and electrical cardioversion alone (shock-only). Our secondary aim was to compare the effectiveness of two pad positions for electrical cardioversion. METHODS: We did a partial factorial trial of two protocols for patients with acute atrial fibrillation at 11 academic hospital emergency departments in Canada. We enrolled adult patients with acute atrial fibrillation. Protocol 1 was a randomised, blinded, placebo-controlled comparison of attempted pharmacological cardioversion with intravenous procainamide (15 mg/kg over 30 min) followed by electrical cardioversion if necessary (up to three shocks, each of ≥200 J), and placebo infusion followed by electrical cardioversion. For patients having electrical cardioversion, we used Protocol 2, a randomised, open-label, nested comparison of anteroposterior versus anterolateral pad positions. Patients were randomly assigned (1:1, stratified by study site) for Protocol 1 by on-site research personnel using an online electronic data capture system. Randomisation for Protocol 2 occurred 30 min after drug infusion for patients who had not converted and was stratified by site and Protocol 1 allocation. Patients and all research and emergency department staff were masked to treatment allocation for Protocol 1. The primary outcome was conversion to normal sinus rhythm for at least 30 min at any time after randomisation and up to a point immediately after three shocks. Protocol 1 was analysed by intention to treat and Protocol 2 excluded patients who did not receive electrical cardioversion. This study is registered at ClinicalTrials.gov, number NCT01891058. FINDINGS: Between July 18, 2013, and Oct 17, 2018, we enrolled 396 patients, and none were lost to follow-up. In the drug-shock group (n=204), conversion to sinus rhythm occurred in 196 (96%) patients and in the shock-only group (n=192), conversion occurred in 176 (92%) patients (absolute difference 4%; 95% CI 0-9; p=0·07). The proportion of patients discharged home was 97% (n=198) versus 95% (n=183; p=0·60). 106 (52%) patients in the drug-shock group converted after drug infusion only. No patients had serious adverse events in follow-up. The different pad positions in Protocol 2 (n=244), had similar conversions to sinus rhythm (119 [94%] of 127 in anterolateral group vs 108 [92%] of 117 in anteroposterior group; p=0·68). INTERPRETATION: Both the drug-shock and shock-only strategies were highly effective, rapid, and safe in restoring sinus rhythm for patients in the emergency department with acute atrial fibrillation, avoiding the need for return to hospital. The drug infusion worked for about half of patients and avoided the resource intensive procedural sedation required for electrical cardioversion. We also found no significant difference between the anterolateral and anteroposterior pad positions for electrical cardioversion. Immediate rhythm control for patients in the emergency department with acute atrial fibrillation leads to excellent outcomes. FUNDING: Heart and Stroke Foundation of Canada and the Canadian Institutes of Health Research.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos Clínicos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
15.
J Cardiovasc Electrophysiol ; 32(11): 2943-2952, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34455655

RESUMO

INTRODUCTION: The distance from the descending aorta (DA) to the posterior wall of the left atrium (LA) is variable. We aimed to determine whether the proximity between the DA and the left inferior pulmonary vein (LIPV) ostium has an impact on biophysical parameters and cryoballoon (CB) ablation efficacy during LIPV freezing. METHODS: Patients referred for CB-ablation of atrial fibrillation (AF) in two high-volume centers were included. Cryoablation data were collected prospectively for each patient. The anatomical relationships between the LIPV and the DA (distance LIPV ostium-DA, presence of an aortic imprint on the posterior aspect of the LIPV) were then retrospectively analysed on the LA computed tomography scans realized before AF ablation. RESULTS: A total of 350 patients were included (70% men, 59.7 ± 11.5 years). The decrease in the Ostium-DA distance was significantly correlated to the increase in the time-to-isolation (TTI) (r = -.31; p = .036), with less negative temperature (r = -.11; p = .045). Similarly, the presence of an aortic imprint on the LIPV was associated with a longer TTI (p < .001). The analysis of redo procedures data shows a trend toward the presence of shorter ostium-DA distances (15.3 ± 3.29 vs. 18.1 ± 4.99, p = .15) and more frequent aortic imprints (63.6% vs. 47.5%, p = .34) in patients with LIPV reconnection as opposed to patients without reconnection in the LIPV. CONCLUSION: Our findings indicated that the DA seems to have a "radiator" effect influencing LIPV cryoablation parameters during CB-ablation. Additional studies will be needed to elucidate whether this biophysical influence has a clinical impact in LIPVs reconnections.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Aorta Torácica , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
16.
BMC Health Serv Res ; 21(1): 435, 2021 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-33957918

RESUMO

BACKGROUND/PURPOSE: Interventional cardiac electrophysiology (EP) is a rapidly evolving field in Canada; a nationwide registry was established in 2011 to conduct a periodic review of resource allocation. METHODS: The registry collects annual data on EP lab infrastructure, imaging, tools, human resources, procedural volumes, success rates, and wait times. Leading physicians from each EP lab were contacted electronically; participation was voluntary. RESULTS: All Canadian EP centres were identified (n = 30); 50 and 45 % of active centres participated in the last 2 instalments of the registry. A mean of 508 ± 270 standard and complex catheter ablation procedures were reported annually for 2015-2016 by all responding centres. The most frequently performed ablation targets atrial fibrillation (PVI) arrhythmia accounting for 36 % of all procedures (mean = 164 ± 85). The number of full time physicians ranges between 1 and 7 per centre, (mean = 4). The mean wait time to see an electrophysiologist for an initial non-urgent consult is 23 weeks. The wait time between an EP consult and ablation date is 17.8 weeks for simple ablation, and 30.1 weeks for AF ablation. On average centres have 2 (range: 1-4) rooms equipped for ablations; each centre uses the EP lab an average of 7 shifts per week. While diagnostic studies and radiofrequency ablations are performed in all centres, point-by-point cryoablation is available in 85 % centres; 38 % of the respondents use circular ablation techniques. CONCLUSIONS: This initiative provides contemporary data on invasive electrophysiology lab practices. The EP registry provides activity benchmarks on national trends and practices.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Técnicas Eletrofisiológicas Cardíacas , Eletrofisiologia , Humanos , Sistema de Registros , Resultado do Tratamento
17.
Circulation ; 140(22): 1779-1788, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31630538

RESUMO

BACKGROUND: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation. METHODS: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder. RESULTS: One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%-100.0%) with CF-RF, 99.9% (interquartile range, 65.3%-100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%-100.0%) with Cryo-2 (P=0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups (P=0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 vs cryoballoon groups). CONCLUSIONS: In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913522.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Feminino , Fluoroscopia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-32627264

RESUMO

BACKGROUND: Concerns remain regarding the effectiveness of PVI using the fixed diameter non-compliant cryoballoon in the presence of a left common pulmonary vein (LCPV). We sought to evaluate the effectiveness of PVI performed by contact-force guided radiofrequency (CF-RF) versus second-generation cryoballoon-based ablation in patients with LCPV. METHODS AND RESULTS: We enrolled 346 patients with paroxysmal AF and randomized them to CF-RF or cryoballoon ablation. PV anatomy was not assessed prior to enrolment, and there were no exclusions based on PV anatomy. All patients received an implantable cardiac monitor. LCPV was observed in 13.6% of patients (47/346). Left atrial time and fluoroscopy time did not differ between those with and without LCPV (P=0.58 and P=0.06, respectively). Freedom from any atrial tachyarrhythmia at one year was observed in 46.8% with LCPV and 54.5% without LCPV (P=0.06). In those with LCPV the freedom from any atrial tachyarrhythmia did not differ between those randomized to CF-RF or cryoballoon ablation (HR for recurrence 1.19, 95% CI 0.53-2.65, P=0.69). In those with LCPV the AF burden was reduced to a similar extent with CF-RF and cryoballoon ablation (99.7% vs. 99.5%, respectively; P=0.97). CONCLUSIONS: In this randomized clinical trial, the presence of a LCPV was associated with a trend towards higher rates of arrhythmia recurrence following PVI. No significant difference in arrhythmia recurrence was observed between patients with LCPV randomized to cryoballoon ablation or contact-force guided RF ablation, suggesting that either ablation modality is suitable in this population. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE], NCT01913522) This article is protected by copyright. All rights reserved.

19.
Pacing Clin Electrophysiol ; 43(6): 583-592, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32333413

RESUMO

BACKGROUND: Existing data on the effectiveness and safety of atrial fibrillation (AF) ablation in females are limited to studies of small sample size, lacking longer term follow-up or adjustment for potential confounders. METHODS: A total of 6421 patients (2072 females) undergoing a first AF ablation procedure after enrollment in the Chinese Atrial Fibrillation Registry (China-AF) study between August 2011 and December 2017 were analyzed. We evaluated the effectiveness (recurrence of documented [symptomatic or not] atrial tachyarrhythmia (AT)) and the safety (incidence of procedure-related complications) of AF ablation in female patients compared to male patients. Sensitivity analyses based on routine data were also utilized to avoid potential sex differences in reporting of AF symptoms. RESULTS: Females were about 5 years older than males at the time of ablation (mean age 63.4 ± 9.5 vs 58.3 ± 10.8, P < .0001). A higher proportion of female patients had paroxysmal AF (74.3% vs 56.7%, P < .0001), hypertension (69.7% vs 61.3%, P < .0001), and hyperlipidemia (57.2% vs 52.9%, P = .001). Female sex was found to be an independent risk factor of AT recurrence in multivariate analyses (HR = 1.26, 95% CI 1.15-1.38, P < .0001). These findings were confirmed in sensitivity analyses using only Holter data. Female sex was also associated with a higher risk of periprocedural complications after adjustment for baseline variables (OR = 1.41, 95% CI 1.03-1.94, P = .03). CONCLUSIONS: Female sex is an independent risk factor of AT recurrence and periprocedural complications after AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores Sexuais , Resultado do Tratamento
20.
J Electrocardiol ; 60: 159-164, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32371199

RESUMO

BACKGROUND: Contemporary guidelines recommend that atrial fibrillation (AF) be classified into paroxysmal and persistent AF based on clinical assessment, with these categorizations forming the basis of therapeutic recommendations. While pragmatic, clinical assessment may introduce misclassification errors, which may impact treatment decisions. We sought to determine the relationship between AF classification, baseline AF burden, and post-ablation arrhythmia outcomes. DESIGN: The current study is a sub-analysis of a prospective, parallel-group, multicenter, single-blinded randomized clinical trial. All 346 patients enrolled in CIRCA-DOSE received an implantable cardiac monitor a median of 72 days prior to ablation. AF was classified as low burden paroxysmal, high burden paroxysmal, or persistent based on clinical assessment prior to device implantation. Prior to ablation patients were re-classified using the same definitions based on device monitoring data. Correlation between classifications, AF burden, and post-ablation arrhythmia outcomes were assessed. RESULTS: There was poor agreement between clinical and device-based AF classification (Cohen's kappa: 0.192). AF classification derived from pre-ablation continuous monitoring reflected baseline and post-ablation AF burden with greater accuracy and with less overlap between the AF classes (P < 0.01 for all categorical comparisons). Patients objectively classified as "Low Burden" paroxysmal by continuous monitoring data had significantly greater freedom from recurrent AF/AT/AFL compared to those classified as "High Burden" paroxysmal (hazard ratio [HR] 0.57 for AF/AT/AFL recurrence) or persistent AF (HR 0.19 for AF/AT/AFL recurrence). CONCLUSIONS: Classification of AF pattern based on pre-ablation continuous cardiac rhythm monitoring better predicted AF burden and freedom from recurrent AF post ablation. Despite the use of standardized definitions, classification of AF based on clinical assessment did not predict baseline AF burden, post ablation AF burden, or freedom from recurrent AF post ablation. TRIAL REGISTRATION: ClinicalTrials.govNCT01913522.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA