Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Molecules ; 29(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38611915

RESUMO

Vitamin D (Vit D) is a fat-soluble molecule acting like a hormone, and it is involved in several biological mechanisms such as gene expression, calcium homeostasis, bone metabolism, immune modulation, viral protection, and neuromuscular functions. Vit D deficiency can lead to chronic hypocalcemia, hyperparathyroidism, and many other pathological conditions; in this context, low and very low levels of 25-hydroxy-vitamin D (25-OH-D) were found to be associated with an increased risk of COVID-19 infection and the likelihood of many severe diseases. For all these reasons, it is important to quantify and monitor 25-OH-D levels to ensure that the serum/blood concentrations are not clinically suboptimal. Serum concentration of 25-OH-D is currently the main indicator of Vit D status, and it is currently performed by different assays, but the most common quantitation techniques involve immunometric methods or chromatography. Nevertheless, other quantitation techniques and instruments are now emerging, such as AFIAS-1® and AFIAS-10® (Boditech and Menarini) based on the immunofluorescence analyzer, that guarantee an automated system with cartridges able to give quick and reliable results as a point-of-care test (POCT). This work aims to compare AFIAS-1® and AFIAS-10® (Boditech and Menarini) Vit D quantitation with Ultra High-Performance Liquid Chromatography coupled with tandem mass spectrometry that currently represents the gold standard technique for Vit D quantitation. The analyses were performed in parallel on 56 samples and in different conditions (from fresh and frozen plasma) to assess the reliability of the results. Any statistically significant differences in methods, the fixed error, and the error proportional to concentration were reported. Results obtained in all conditions showed a good correlation between both AFIAS® instruments and LC-MS/MS, and we can affirm that AFIAS-1® and AFIAS-10® are reliable instruments for measuring 25-OH-D with accuracy and in a fast manner.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Cromatografia Líquida , Reprodutibilidade dos Testes , Vitaminas , Imunofluorescência , Imunoensaio
2.
Pharmaceutics ; 15(9)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37765315

RESUMO

BACKGROUND: Fosfomycin acts against aerobic Gram-/+ bacteria by blocking the synthesis of peptidoglycan. Its use has been currently re-evaluated for intravenous administration for the treatment of systemic infections by multidrug-resistant bacteria. Concentration-/time-dependent activity has been suggested, with potential clinical advantages from prolonged or continuous infusion. Nevertheless, little is known about Fosfomycin stability in elastomeric pumps. The aim of the present work was stability investigation before administration at 4 °C and during administration at 34 °C. METHODS: InfectoFos® (InfectoPharm s.r.l., Milan, Italy) preparation for intravenous use in elastomeric pumps at 4 °C and 34 °C was analyzed following EMA guidelines for drug stability. Samples were analyzed with an ultra-high performance liquid chromatography coupled with tandem mass spectrometry method on a LX50® UHPLC system equipped with a QSight 220® (Perkin Elmer, Milan, Italy) tandem mass spectrometer. RESULTS: Fosfomycin in elastomeric preparation is stable for at least 5 days at a storage temperature of 4 °C and 34 °C. CONCLUSIONS: The results suggest Fosfomycin eligibility for continuous infusion even in the context of outpatient parenteral antibiotic therapy. Therefore, this approach should be tested in clinical and pharmacokinetic studies, in order to evaluate the possible gains in the pharmacokinetic profile and the clinical effectiveness.

3.
Biomed Pharmacother ; 163: 114790, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37126927

RESUMO

BACKGROUND: Therapeutic drug monitoring (TDM) for antibiotic drugs represents a consolidated practice to optimize the effectiveness and to limit the toxicity of specific drugs by guiding dosage adjustments. The comparison of TDM results with drug-specific pharmacokinetic/pharmacodynamic (PK/PD) parameters, based on killing dynamics and bacterial susceptibility, increases the probability of therapeutic success. PURPOSE: The aim of this study was the analytical validation of a new UHPLC-MS/MS assay for the quantification of 19 antibiotics divided in two different sets considering their chemical/pharmacological properties. This method has been implemented in an analytical LC-MS/MS Kit System by CoQua Lab s.r.l (Turin). METHODS: The analytical validation is developed in accordance with "ICH Harmonized Guideline M10 on bioanalytical method validation and study sample analysis" and "Guidelines for regulatory auditing of quality management system of medical device manufacturers". Method suitability in the clinical context was tested by analysing clinical samples from patients treated with antibiotic drugs. RESULTS: This method allows for simultaneous TDM of the following molecules: dalbavancin, daptomycin, linezolid, tedizolid, levofloxacin, moxifloxacin, meropenem, ertapenem, vaborbactam, avibactam, sulbactam, tazobactam, ceftazidime, ceftriaxone, ceftolozane, ceftobiprole, cefiderocol, ceftaroline and piperacillin. These drugs were quantified showing analytical performance parameters compliant with guidelines in terms of repeatability, reproducibility, robustness, bias, LOD, LOQ and linearity. The method was capable to successfully monitor drug concentrations in 65 samples from 52 patients undergoing treatment. CONCLUSION: The UHPLC-MS/MS method described in this work can be useful for TDM of the reported antimicrobial agents. The analytical protocol is rapid and suitable to be used in routine analysis.


Assuntos
Antibacterianos , Espectrometria de Massas em Tandem , Humanos , Antibacterianos/uso terapêutico , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes
4.
Antioxidants (Basel) ; 12(5)2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-37237997

RESUMO

An uncontrolled inflammatory response during SARS-CoV-2 infection has been highlighted in several studies. This seems to be due to pro-inflammatory cytokines whose production could be regulated by vitamin D, ROS production or mitogen-activated protein kinase (MAPK). Several genetic studies are present in the literature concerning genetic influences on COVID-19 characteristics, but there are few data on oxidative stress, vitamin D, MAPK and inflammation-related factors, considering gender and age. Therefore, the aim of this study was to evaluate the role of single nucleotide polymorphisms in these pathways, clarifying their impact in affecting COVID-19-related clinical features. Genetic polymorphisms were evaluated through real-time PCR. We prospectively enrolled 160 individuals: 139 patients were positive for SARS-CoV-2 detection. We detected different genetic variants able to affect the symptoms and oxygenation. Furthermore, two sub-analyses were performed considering gender and age, showing a different impact of polymorphisms according to these characteristics. This is the first study highlighting a possible contribution of genetic variants of these pathways in affecting COVID-19 clinical features. This may be relevant in order to clarify the COVID-19 etiopathogenesis and to understand the possible genetic contribution for further SARS infections.

5.
Biomed Pharmacother ; 165: 115103, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37413901

RESUMO

Schizophrenia affects approximately 24 million people worldwide and clozapine is the most effective antipsychotic drug. Nevertheless, its use in therapy is limited due to adverse effects.Therapeutic drug monitoring is a clinical tool useful to reduce the clozapine toxicity. In the literature, papers showed how psychiatric disorders could be associated with low vitamin D levels, but a few studies focusing on its role in affecting clozapine exposure are available. A TDM repository was analyzed: clozapine and vitamin D levels measured with liquid chromatography were considered. 1261 samples obtained from 228 individuals were evaluated: 624 patients (49.5%) showed clozapine plasma levels in therapeutic range (350-600 ng/mL). Clozapine toxic plasma levels (>1000 ng/mL) were more present in winter (p = 0.025), compared to other seasons. Concerning vitamin D, a sub-analysis of 859 samples was performed: 326 (37.81%) were deficient ( ng/mL), 490 (57.12%) had insufficient concentrations (10-30 ng/mL), while 43 (5.02%) had sufficient (>30 ng/mL) levels. A correlation between vitamin D and clozapine plasma levels (p = 0.007, Pearson coefficient=0.093) was observed. The role of seasonal variation in clozapine plasma exposure in psychiatric patients treated with clozapine was suggested. Further studies in larger cohorts are needed in order to clarify these aspects.


Assuntos
Antipsicóticos , Clozapina , Esquizofrenia , Humanos , Clozapina/efeitos adversos , Vitamina D/uso terapêutico , Antipsicóticos/efeitos adversos , Esquizofrenia/tratamento farmacológico , Esquizofrenia/induzido quimicamente , Plasma , Vitaminas/uso terapêutico
6.
Biomed Pharmacother ; 156: 113899, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36279720

RESUMO

Cannabinoid derivates have been largely used for different medical purpose. In the literature, several methods capable of separating THC and its principles metabolites are described, although Δ8- and Δ9-THC separation has not been completely achieved. THC metabolism has not been fully understood and metabolites plasma distribution in healthy and pathological patients remains to further deepen. The aim of this study was the validation of UHPLC-MS/MS method for the quantification of 10 cannabinoids in human plasma, as important tool for improving clinical efficacy of cannabis administration. Obtained results were in accordance with recommendations of ICH Harmonised Guideline for bioanalytical method validation, showing a good linearity, optimal accuracy as well as satisfactory results in terms of intra-day and inter-day precision and matrix effect. Furthermore, blood sampling study was performed to investigate the better collection method. Optimal separation of Δ-9-tetrahydrocannabinol (Δ9-THC), Δ8-tetrahydrocannabinol (Δ8-THC) was obtained. The present method showed optimal linearity and satisfactory results in terms of specificity and selectivity. Recovery was between 92.0% and 96.5% for all analytes. The matrix-effect showed good performance; no carry over was observed. Cannabinoid metabolites present in higher plasma concentrations were: 11-Hydroxy-Δ9-tetrahydrocannabinol, 11-Nor-9carboxy-Δ9-tetrahydrocannabinol and THC-COOH-glucuronide. Method performance makes it suitable for routine purposes and a potential tool for therapeutic ranges definition. The present work will be used to test several samples in a long-term clinical study, paving the way for further future works.


Assuntos
Canabinoides , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Canabinoides/metabolismo , Dronabinol/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA