RESUMO
BACKGROUND: The diagnostic accuracy of stress myocardial perfusion single-photon emission computed tomography (SPECT) to detect coronary artery disease (CAD) is reduced by the balanced reduction of myocardial perfusion in patients with multi-vessel or left main trunk CAD (multi-vessel group). This study investigated the diagnostic performance of a simultaneous acquisition rest 99 mTc/stress 201Tl dual-isotope protocol for myocardial perfusion SPECT (MPS) in a multi-vessel group by examining the assessment of a slow 201Tl washout rate (WR) finding in comparison to the accuracy of perfusion assessments.MethodsâandâResults: This study enrolled 91 patients who had undergone angiography within 3 months after MPS. The diagnostic performances of perfusion assessments and a slow 201Tl WR parameter were compared using the area under the curve (AUC) in a multi-vessel group of patients with mild ischemia (2≤summed difference score [SDS]≤7). The AUC of a slow WR parameter was significantly larger compared with that for perfusion assessments, in patients with mild ischemia, (AUC, 0.736 vs. 0.504-0.558, P value: <0.01-0.05). CONCLUSIONS: Among patients with mild ischemia, a slow 201Tl WR parameter improved the detection of CAD in a multi-vessel group.
Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Câmaras gama , Humanos , Imagem de Perfusão do Miocárdio/métodos , Descanso , Semicondutores , Tecnécio , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodosRESUMO
BACKGROUND: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT.MethodsâandâResults:The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). CONCLUSIONS: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.
Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Teste de Esforço , Imagem de Perfusão do Miocárdio/métodos , Descanso , Adenosina/administração & dosagem , Idoso , Cardiotônicos/administração & dosagem , Confiabilidade dos Dados , Dobutamina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Vasodilatadores/administração & dosagemRESUMO
The diagnostic performance of 320-detector cardiac computed tomography (CCT) for the detection of thrombi in the left atrial appendage (LAA), relative to transesophageal echocardiography (TEE) as the gold standard, has not yet been evaluated. A total of 91 consecutive patients who were scheduled to undergo pulmonary vein isolation and underwent TEE and CCT were enrolled in this study. Delayed scanning on CCT was performed following early scanning, at 60 seconds after the start of the contrast injection. The radiation dose was estimated for both scans. The early scans showed a contrast medium filling defect (FD) in the LAA in 27 patients, whereas the delayed scans showed an FD in the LAA in six patients. Of these, five patients were confirmed to have a thrombus in the LAA by TEE. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 100, 74.4, 18.5, 100, and 75.8% for early scanning and 100, 98.8, 83.3, 100, and 98.9% for delayed scanning, respectively. The area under the curve for the detection of a thrombus in the LAA on the delayed scans was significantly larger than that for the detection on the early scans (0.99 versus 0.87, P < 0.001). The estimated median radiation doses for the early and delayed scans were 2.86 and 0.42 mSv, respectively. Addition of delayed scanning to early scanning improved the diagnostic performance for the detection of a thrombus in the LAA and may obviate unnecessary TEE, with minimal additional radiation exposure.
Assuntos
Apêndice Atrial/diagnóstico por imagem , Cardiopatias/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Trombose/diagnóstico , Idoso , Fibrilação Atrial/complicações , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Trombose/etiologiaRESUMO
BACKGROUND: The aim of this study was to evaluate the clinical feasibility of simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope single-photon emission computed tomography with a semiconductor gamma camera. METHODSâANDâRESULTS: Ninety-four patients with known or suspected coronary artery disease (CAD) were enrolled in the study. First, patients were injected with (99m)Tc-tetrofosmin (296 MBq) for rest imaging, followed by (201)Tl (74 MBq) injection during 6 min of vasodilator stress test. Immediately after the stress test, the patients underwent the first electrocardiogram (ECG)-gated simultaneous acquisition including rest and stress perfusion scans. Patients were brought back for the second simultaneous acquisition for the comparison of ECG-gated wall motion between stress and rest scan 30 min later. Coronary angiography was performed in all the patients within 3 months of this protocol. Sensitivity, specificity and accuracy on a per patient basis to detect significant coronary artery stenosis (≥75%) were 88.6%, 79.2% and 86.2%, respectively. Per coronary vessel, sensitivity, specificity and accuracy were as follows: 84.9%, 80.5% and 83% in the left anterior descending coronary artery; 75%, 93.1% and 86.2% in the left circumflex coronary artery; and 74.2%, 85.7% and 81.9% in the right coronary artery. CONCLUSIONS: Simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope protocol had high diagnostic accuracy for significant CAD. (Circ J 2016; 80: 689-695).
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/instrumentação , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados/administração & dosagem , Compostos de Organotecnécio/administração & dosagemRESUMO
Background: The use of 201Tl in myocardial perfusion single-photon emission computed tomography (SPECT) is predominantly not recommended because of the higher radiation exposure of 201Tl compared to 99mTc agent. However, the advent of new gamma cameras with semiconductor detectors has made it possible to reduce the 201Tl dose and lower radiation exposure. In our hospital, the dose of 201Tl is adjusted according to the patient's body mass index (BMI), with 50 MBq for BMI<25 and 74 MBq for BMI≥25. The dose of 201Tl during simultaneous acquisition dual-isotope myocardial perfusion SPECT (MPS; stress 201Tl and rest 99mTc agent) exceeds 9 mSv/examination when 74 MBq of 201Tl is administered. In order to further reduce the radiation dose, optimization of the 201Tl dose was investigated. Methods: Two hundred and eighty consecutive patients who underwent stress MPS using simultaneous acquisition dual-isotope protocol (SDI protocol) for the estimation of ischemic heart disease were included. Patients with prior myocardial infarction were excluded. Correlations between BMI and acquisition time were determined in patients receiving 50 MBq (n=154) or 74 MBq (n=126) of 201Tl. In addition, linear regression analysis was used to determine the slope and intercept to derive a linear functional equation, and the theoretically optimal 201Tl dose was evaluated. Results: The correlation coefficient between BMI and acquisition time in the 201Tl 50 MBq group was 0.532 (P< 0.00001) and in the 201Tl 74 MBq group was 0.478 (P<0.00001), both showing a positive correlation. Linear regression analysis yielded two equations: y=0.52x-0.32 (201Tl 50 MBq group) and y=0.41x-0.69 (201Tl 74 MBq group). Linear function equation results indicated that patients with BMI between 25 and 30 could be examined within approximately 15 minutes with 50 MBq of 201Tl. Conclusion: Considering examination efficiency, a single acquisition time of less than 15 minutes is ideal. Theoretically, patients with BMI less than 30 could be examined within approximately 15 minutes with 50 MBq of 201Tl.
RESUMO
Since Agatston et al. first reported quantification of the coronary artery calcification score (CACS) in 1990, discussion of its clinical significance and use in diagnostic management has continued. Recent papers have reported the relationship between CACS and myocardial perfusion single photon emission computed tomography (SPECT: MPS) and its combined diagnostic value. When interpreting CACS results, it should be noted that the frequency of significant ischemia detected by MPS, likelihood of coronary artery disease (CAD), and event rate gradually increased from mild to moderate CACS (1-400). At present, high CACS is considered to be moderately consistent with abnormal MPS, and abnormal CACS in normal MPS may contribute to CAD risk stratification. However, it should be noted that CACS=0 does not completely exclude CAD, which is particularly important when using CACS as a gatekeeper for MPS. Both stand-alone computed tomography (CT) scanner and hybrid SPECT-CT scanner are available for combined risk stratification of CACS and MPS in addition to improvement of image quality with attenuation correction.