Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cytometry A ; 103(9): 736-743, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37306103

RESUMO

Ultraviolet lasers are commonly used in flow cytometry to excite fluorochrome molecules with subsequent measurement of the specific fluorescence of individual cells. In this study, the performance of the ultraviolet light scattering (UVLS) in the analysis of individual particles with flow cytometry has been demonstrated for the first time. The main advantage of the UVLS relates to the improvement of the analysis of submicron particles due to the strong dependence of the scattering efficiency on the wavelength of the incident light. In this work, submicron particles were analyzed using a scanning flow cytometer (SFC) that allows measurements of light scattering in an angle-resolved regime. The measured light-scattering profiles of individual particles were utilized in solution of the inverse light-scattering problem to retrieve the particle characteristics using a global optimization. The standard polystyrene microspheres were successfully characterized from the analysis of UVLS which provided the size and refractive index (RI) of individual beads. We believe that the main application of UVLS relates to the analysis of microparticles in a serum, in particular in the analysis of chylomicrons (CMs). We have demonstrated the performance of the UVLS SFC in the analysis of CMs of a donor. The RI versus size scatterplot of CMs was successfully retrieved from the analysis. The current set-up of the SFC has allowed us to characterize individual CMs starting from the size of 160 nm that provides determination of the CM concentration in a serum with flow cytometry. This feature of the UVLS should help with the analysis of lipid metabolism measuring RI and size map evolution after lipase action.


Assuntos
Micropartículas Derivadas de Células , Raios Ultravioleta , Citometria de Fluxo , Espalhamento de Radiação , Metabolismo dos Lipídeos , Tamanho da Partícula
2.
Cytometry A ; 103(9): 712-722, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37195007

RESUMO

Methods for measuring erythrocyte age distribution are not available as a simple analytical tool. Most of them utilize the fluorescence or radioactive isotopes labeling to construct the age distribution and support physicians with aging indices of donor's erythrocytes. The age distribution of erythrocyte may be a useful snapshot of patient state over 120-days period of life. Previously, we introduced the enhanced assay of erythrocytes with measurement of 48 indices in four categories: concentration/content, morphology, aging and function (10.1002/cyto.a.24554). The aging category was formed by the indices based on the evaluation of the derived age of individual cells. The derived age does not exactly mean the real age of erythrocytes and its evaluation utilizes changes of cellular morphology during a lifespan. In this study, we are introducing the improved methodological approach that allows us to retrieve the derived age of individual erythrocytes, to construct the aging distribution, and to reform the aging category consisting of eight indices. The approach is based on the analysis of the erythrocyte vesiculation. The erythrocyte morphology is analyzed by scanning flow cytometry that measures the primary characteristics (diameter, thickness, and waist) of individual cells. The surface area (S) and sphericity index (SI) are calculated from the primary characteristics and the scattering diagram SI versus S is used in the evaluation of the derived age of each erythrocyte in a sample. We developed the algorithm to evaluate the derived age that provides eight indices in the aging category based on a model using light scatter features. The novel erythrocyte indices were measured for simulated cells and blood samples of 50 donors. We determined the first-ever reference intervals for these indices.


Assuntos
Índices de Eritrócitos , Eritrócitos , Humanos , Lactente , Citometria de Fluxo/métodos
3.
Cytometry A ; 103(1): 39-53, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35349217

RESUMO

Molecular/cell level of gas exchange function assumes the accurate measurement of erythrocyte characteristics and rate constants concerning to molecules involved into the CO2 /O2 transport. Unfortunately, common hematology analyzers provide the measurement of eight indices of erythrocytes only and say little about erythrocyte morphology and nothing about rate constants of cellular function. The aim of this study is to demonstrate the ability of the Scanning Flow Cytometer (SFC) in the complete morphological analysis of mature erythrocytes and characterization of erythrocyte function via measurement of lysing kinetics. With this study we are introducing 48 erythrocyte indices. To provide the usability of application of the SFC in clinical diagnosis, we formed four categories of indices which are as follows: content/concentration (9 indices), morphology (26 indices), age (5 indices), and function (8 indices). The erythrocytes of 39 healthy volunteers were analyzed with the SFC to fix the first-ever reference intervals for the new indices introduced. The essential measurable reliability of the presented method is expressed in terms of errors of characteristics of single erythrocytes retrieved from the solution of the inverse light-scattering problem and errors of parameters retrieved from the fitting of the experimental kinetics by molecular-kinetics model of erythrocyte lysis.


Assuntos
Índices de Eritrócitos , Eritrócitos , Humanos , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Morte Celular
4.
Cytometry A ; 95(12): 1275-1284, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31750613

RESUMO

Nifedipine is calcium channels and pumps blocker widely used in medicine. However, mechanisms of nifedipine action in blood are not clear. In particular, the influence of nifedipine on erythrocytes is far from completely understood. In this work, applying scanning flow cytometry, we observed experimentally for the first time the dynamics behind a significant increase of HCO3- /Cl- transmembrane exchange rate of CDB3 (main anion exchanger, AE1, Band 3, SLC4A1) of human erythrocytes in the presence of nifedipine in blood. It was found that the rate of CDB3 activation is not limited by the rate of nifedipine binding and/or Ca2+ transport. In order to explain the experimental data, we suggested a kinetic model assuming that the rate of CDB3 activation is limited by the dynamics of the balance between two intracellular processes (1) the activation of CDB3 limited by its interaction with intracellular Ca2+ , and (2) the spontaneous deactivation of CDB3. Thus the use of scanning flow cytometry allowed to clarify quantitatively the molecular kinetic mechanism of nifedipine action on human erythrocytes. In particular, the efficiency (~30) and rates of activation (~0.3 min-1 ) and deactivation (~10-3 min-1 ) of CDB3 in human erythrocytes was evaluated for two donors. © 2019 International Society for Advancement of Cytometry.


Assuntos
Proteína 1 de Troca de Ânion do Eritrócito/metabolismo , Eritrócitos/metabolismo , Citometria de Fluxo , Nifedipino/farmacologia , Eritrócitos/efeitos dos fármacos , Humanos
5.
PLoS Comput Biol ; 14(3): e1005899, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29518073

RESUMO

We present a simple physically based quantitative model of blood platelet shape and its evolution during agonist-induced activation. The model is based on the consideration of two major cytoskeletal elements: the marginal band of microtubules and the submembrane cortex. Mathematically, we consider the problem of minimization of surface area constrained to confine the marginal band and a certain cellular volume. For resting platelets, the marginal band appears as a peripheral ring, allowing for the analytical solution of the minimization problem. Upon activation, the marginal band coils out of plane and forms 3D convoluted structure. We show that its shape is well approximated by an overcurved circle, a mathematical concept of closed curve with constant excessive curvature. Possible mechanisms leading to such marginal band coiling are discussed, resulting in simple parametric expression for the marginal band shape during platelet activation. The excessive curvature of marginal band is a convenient state variable which tracks the progress of activation. The cell surface is determined using numerical optimization. The shapes are strictly mathematically defined by only three parameters and show good agreement with literature data. They can be utilized in simulation of platelets interaction with different physical fields, e.g. for the description of hydrodynamic and mechanical properties of platelets, leading to better understanding of platelets margination and adhesion and thrombus formation in blood flow. It would also facilitate precise characterization of platelets in clinical diagnosis, where a novel optical model is needed for the correct solution of inverse light-scattering problem.


Assuntos
Plaquetas/citologia , Plaquetas/fisiologia , Forma Celular/fisiologia , Biologia Computacional/métodos , Ativação Plaquetária/fisiologia , Algoritmos , Simulação por Computador , Humanos
6.
Cytometry A ; 93(7): 695-705, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30110130

RESUMO

We propose a calibration-free method to determine the number of receptors per cell, as well as the direct and the reverse reaction rate constants for a single receptor. The method is based on the analysis of the temporal evolution of the cells mean fluorescent intensity measured by a flow cytometer during the ligand-receptor (antigen-antibody) binding under the conditions of their comparable concentrations. We developed the kinetic approach accounting both for the delay between the dilution and the measurement and for the practical duration of the measurement itself. The method was applied to determine thenumber of CD14 receptors on human blood mononuclear (granulocytes, monocytes, lymphocytes) cells of several donors. We also obtained the direct ( k+= (5.6 ± 0.2) × 107 M-1 min-1 ) and reverse ( k-= (1.3 ± 0.2) × 10-2 min-1 ) rate constants of ligand-receptor interaction, and estimated the size of the binding site as b = 0.5 nm. The latter allows one to recalculate the rate constants for a different ligand, fluorescent label, medium viscosity, and/or temperature. The knowledge of the rate constants is essential for the calibration-free determination of the number of receptors per cell from a single kinetic curve of the cells mean fluorescence intensity.


Assuntos
Citometria de Fluxo/métodos , Imunoensaio/métodos , Receptores de Lipopolissacarídeos/química , Sítios de Ligação de Anticorpos , Humanos , Imunoglobulina G/química , Imunoglobulina G/imunologia , Leucócitos/química , Leucócitos/imunologia , Receptores de Lipopolissacarídeos/imunologia , Ligação Proteica
7.
J Theor Biol ; 454: 60-69, 2018 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-29859212

RESUMO

The dynamics of nuclear morphology changes during apoptosis remains poorly investigated and understood. Using 3D time-lapse confocal microscopy we performed a study of early-stage apoptotic nuclear morphological changes induced by etoposide in single living HepG2 cells. These observations provide a definitive evidence that nuclear apoptotic volume decrease (AVD) is occurring simultaneously with peripheral chromatin condensation (so called "apoptotic ring"). In order to describe quantitatively the dynamics of nuclear morphological changes in the early stage of apoptosis we suggest a general molecular kinetic model, which fits well the obtained experimental data in our study. Results of this work may clarify molecular mechanisms of nuclear morphology changes during apoptosis.


Assuntos
Apoptose/fisiologia , Núcleo Celular/fisiologia , Modelos Teóricos , Tamanho das Organelas/fisiologia , Análise de Célula Única/métodos , Núcleo Celular/ultraestrutura , Cromatina/química , Cromatina/metabolismo , Cromatina/ultraestrutura , Empacotamento do DNA , Células Hep G2 , Humanos , Imageamento Tridimensional , Cinética , Microscopia Confocal , Imagem com Lapso de Tempo/métodos
8.
Cytometry A ; 89(2): 159-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25808430

RESUMO

Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward-versus-side-scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light-scattering profiles and side scattering from MPs, respectively. The developed two-stage method allowed accurate separation of PLTs and MPs in platelet-rich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light-scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs-median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument-independent quantitative information on MPs, which can be used in studies of various factors affecting MP population.


Assuntos
Plaquetas/fisiologia , Micropartículas Derivadas de Células/fisiologia , Citometria de Fluxo/métodos , Calibragem , Humanos , Luz , Plasma Rico em Plaquetas/citologia , Espalhamento de Radiação
9.
J Theor Biol ; 393: 194-202, 2016 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-26780645

RESUMO

Magnesium sulfate (MgSO4) is widely used in medicine but molecular mechanisms of its protection through influence on erythrocytes are not fully understood and are considerably controversial. Using scanning flow cytometry, in this work for the first time we observed experimentally (both in situ and in vitro) a significant increase of HCO3(-)/Cl(-) transmembrane exchange rate of human erythrocytes in the presence of MgSO4 in blood. For a quantitative analysis of the obtained experimental data, we introduced and verified a molecular kinetic model, which describes activation of major anion exchanger Band 3 (or AE1) by its complexation with free intracellular Mg(2+) (taking into account Mg(2+) membrane transport and intracellular buffering). Fitting the model to our in vitro experimental data, we observed a good correspondence between theoretical and experimental kinetic curves that allowed us to evaluate the model parameters and to estimate for the first time the association constant of Mg(2+) with Band 3 as KB~0.07mM, which is in agreement with known values of the apparent Mg(2+) dissociation constant (from 0.01 to 0.1mM) that reflects experiments on enrichment of Mg(2+) at the inner erythrocyte membrane (Gunther, 2007). Results of this work partly clarify the molecular mechanisms of MgSO4 action in human erythrocytes. The method developed allows one to estimate quantitatively a perspective of MgSO4 treatment for a patient. It should be particularly helpful in prenatal medicine for early detection of pathologies associated with the risk of fetal hypoxia.


Assuntos
Antiportadores de Cloreto-Bicarbonato/metabolismo , Membrana Eritrocítica/metabolismo , Eritrócitos/metabolismo , Sulfato de Magnésio/farmacologia , Proteína 1 de Troca de Ânion do Eritrócito/metabolismo , Membrana Eritrocítica/efeitos dos fármacos , Eritrócitos/efeitos dos fármacos , Espaço Extracelular/metabolismo , Humanos , Cinética , Modelos Biológicos , Doadores de Tecidos
10.
J Opt Soc Am A Opt Image Sci Vis ; 32(12): 2407-8, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26831394

RESUMO

We report and address the errors in the analysis of the weighted discretization in Section 2.F of our published paper [J. Opt. Soc. Am. A23, 2578 (2006)JOAOD61084-752910.1364/JOSAA.23.002578].

11.
J Chem Phys ; 141(6): 064309, 2014 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-25134573

RESUMO

We theoretically analyze the aggregation kinetics of colloid particles with several active sites. Such particles (so-called "patchy particles") are well known as chemically anisotropic reactants, but the corresponding rate constant of their aggregation has not yet been established in a convenient analytical form. Using kinematic approximation for the diffusion problem, we derived an analytical formula for the diffusion-controlled reaction rate constant between two colloid particles (or clusters) with several small active sites under the following assumptions: the relative translational motion is Brownian diffusion, and the isotropic stochastic reorientation of each particle is Markovian and arbitrarily correlated. This formula was shown to produce accurate results in comparison with more sophisticated approaches. Also, to account for the case of a low number of active sites per particle we used Monte Carlo stochastic algorithm based on Gillespie method. Simulations showed that such discrete model is required when this number is less than 10. Finally, we applied the developed approach to the simulation of immunoagglutination, assuming that the formed clusters have fractal structure.


Assuntos
Coloides/química , Algoritmos , Anisotropia , Domínio Catalítico , Simulação de Dinâmica Molecular , Método de Monte Carlo , Tamanho da Partícula , Propriedades de Superfície
12.
Cytometry A ; 83(6): 568-75, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23568828

RESUMO

We demonstrate a flow-cytometric method to measure length and diameter of single Escherichia coli cells with sub-diffraction precision. The method is based on the original scanning flow cytometer that measures angle-resolved light-scattering patterns (LSPs) of individual particles. We modeled the shape of E. coli cells as a cylinder capped with hemispheres of the same radius, and simulated light scattering by the models using the discrete dipole approximation. We computed a database of the LSPs of individual bacteria in a wide range of model parameters and used it to solve the inverse light-scattering problem by the nearest-neighbor interpolation. The solution allows us to determine length and diameter of each individual bacterium, including uncertainties of these estimates. The developed method was tested on two strains of E. coli. The resulting precision of bacteria length and diameter measurements varied from 50 nm to 250 nm and from 5 nm to 25 nm, respectively. The measured distributions of samples over length and diameter were in good agreement with measurements performed by optical microscopy and literature data. The described approach can be applied for rapid morphological characterization of any rod-shaped bacteria.


Assuntos
Escherichia coli/ultraestrutura , Algoritmos , Citometria de Fluxo , Luz , Espalhamento de Radiação , Análise de Célula Única
13.
J Immunol Methods ; 521: 113555, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37666317

RESUMO

For the quantitative determination of cell receptors by fluorescence flow cytometry, we proposed a new method, which takes into account the reaction kinetics. The binding reaction of the ligand with receptors begins after placing the cells in the ligand solution. In the proposed method, there are several samples with the same concentration of cells and different initial concentrations of fluorescently labeled ligand, and each sample is measured by a flow cytometer once at the time when the following condition is met: the product of the incubation time (cells with ligand) and the initial concentration of ligand is the same for all samples. The proposed approach eliminates disadvantages and combines advantages of both kinetic and titration methods for quantification of receptors on single cells without the use of traditional calibration fluorescent beads. Practical application of the method was demonstrated in quantification of CD8 and CD14 on peripheral blood human leukocytes. Particularly, we found decreased (by a factor of two) mean number of CD14 on monocytes and granulocytes in patients with atherosclerosis (treated in the hospital) compared to conditionally healthy donors, whereas no difference was found in the mean CD8 expression on leukocytes between the same patient and donor groups.


Assuntos
Leucócitos , Receptores de Superfície Celular , Humanos , Ligantes , Citometria de Fluxo , Cinética
14.
Anal Methods ; 15(39): 5218-5224, 2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37781887

RESUMO

The analysis of individual particles with complex morphologies from light scattering is crucial in disperse systems studies, such as blood cells. Characterization, which assumes determining particle characteristics, has a higher likelihood of succeeding in solving the inverse light-scattering problem if an instrument provides enough light-scattering data. In this study, we demonstrate how we extend the operating angular interval for the 4π Scanning Flow Cytometer (4πSFC), which measures angle-resolved light-scattering profiles (LSPs) of individual particles. The angular interval is extended by additionally measuring light scattering for the backward hemisphere. Currently, the 4πSFC setup uses three lasers, a single optical cell, and three photomultipliers. It enables the measurement of the LSP of individual particles within the angular interval of 10 to 170° for polar angles with integration over azimuth angles, which covers the spatial angle of 98.5% of the 4π angle. We demonstrate the 4πSFC's performance in measuring LSPs from the analysis of polymer beads, mature and spherized erythrocytes, and platelets. The 4πSFC has the potential to be very useful in identifying platelet dimers and granulocytes without labels, characterizing lymphocytes, monocytes, and abnormal erythrocytes.


Assuntos
Plaquetas , Luz , Citometria de Fluxo , Espalhamento de Radiação , Granulócitos
15.
Biophys J ; 100(2): 507-16, 2011 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-21244847

RESUMO

Determining averaged effective diffusion constants from experimental measurements of fluorescent proteins in an inhomogeneous medium in the presence of ligand-receptor interactions poses problems of analytical tractability. Here, we introduced a nonfitting method to evaluate the averaged effective diffusion coefficient of a region of interest (which may include a whole nucleus) by mathematical processing of the entire cellular two-dimensional spatial pattern of recovered fluorescence. Spatially and temporally resolved measurements of protein transport inside cells were obtained using the fluorescence recovery after photobleaching technique. Two-dimensional images of fluorescence patterns were collected by laser-scanning confocal microscopy. The method was demonstrated by applying it to an estimation of the mobility of green fluorescent protein-tagged heterochromatin protein 1 in the nuclei of living mouse embryonic fibroblasts. This approach does not require the mathematical solution of a corresponding system of diffusion-reaction equations that is typical of conventional fluorescence recovery after photobleaching data processing, and is most useful for investigating highly inhomogeneous areas, such as cell nuclei, which contain many protein foci and chromatin domains.


Assuntos
Proteínas Cromossômicas não Histona/química , Proteínas Cromossômicas não Histona/genética , Recuperação de Fluorescência Após Fotodegradação/métodos , Microscopia Confocal/métodos , Modelos Moleculares , Animais , Linhagem Celular , Núcleo Celular/metabolismo , Homólogo 5 da Proteína Cromobox , Proteínas Cromossômicas não Histona/metabolismo , Difusão , Fluorescência , Proteínas de Fluorescência Verde/metabolismo , Humanos , Matemática , Camundongos , Fotodegradação , Reprodutibilidade dos Testes , Soluções
16.
Cytometry A ; 79(7): 570-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21548080

RESUMO

We instrumentally, theoretically, and experimentally demonstrate a new approach for characterization of nonspherical individual particles from light scattering. Unlike the original optical scheme of the scanning flow cytometer that measures an angle-resolved scattering corresponding in general to S11 element of the light-scattering matrix, the modernized instrument allows us to measure the polarized light-scattering profile of individual particles simultaneously. Theoretically, the polarized profile is expressed by the combination of a few light-scattering matrix elements. This approach supports us with additional independent data to characterize a particle with a complex shape and an internal structure. Applicability of the new method was demonstrated from analysis of polymer bispheres. The bisphere characteristics, sizes, and refractive indices of each sphere composing the bisphere were successfully retrieved from the solution of the inverse light-scattering problem. The solution provides determination of the Eulerian angles, which describe the orientation of the bispheres relative to the direction of the incident laser beam and detecting polarizer of the optical system. Both the ordinary and polarized profiles show a perfect agreement with T-matrix simulation resulting to 50-nm precision for sizing of bispheres.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Luz , Espalhamento de Radiação , Interpretação de Imagem Assistida por Computador/métodos
17.
J Theor Biol ; 290: 1-6, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-21920371

RESUMO

Though flow cytometry provides the entire distribution of cellular fluorescence (i.e., "fluorescence profile"), only mean fluorescence data are usually considered in studies of ligand-receptor binding. In this study, we presented a method of the treatment of the temporal evolution of the whole fluorescence profile with a comprehensive statistical approach extended to the reversible binding case. The method was demonstrated in the study of the 1D3 IgM monoclonal antibodies binding to FcγRIIIb receptors (CD16b) on neutrophils. Kinetic experiments were carried out using a FACSCalibur (Becton Dickinson, USA) flow cytometer. For each of four donors, we obtained the distribution of the number of FcγRIIIb surface receptors for neutrophils and the rate constants per receptor: the association rate constant of (2.7±0.4)×10(7) M(-1) min(-1), and the dissociation rate constant of (1.3±0.4)×10(-1) min(-1). Based on the obtained values, the size of the receptor reaction site was estimated at approximately 1 nm. It was found, that cell receptors distributions differed sufficiently between donors in mean and the skewness values, whereas the coefficient of variation (i.e., the ratio of the standard deviation to the mean) did not vary significantly.


Assuntos
Imunoglobulina M/sangue , Modelos Imunológicos , Neutrófilos/imunologia , Receptores de IgG/sangue , Algoritmos , Anticorpos Monoclonais/metabolismo , Sítios de Ligação de Anticorpos/imunologia , Citometria de Fluxo/métodos , Proteínas Ligadas por GPI/sangue , Humanos
18.
Anal Methods ; 13(29): 3233-3241, 2021 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-34184022

RESUMO

Analysis of blood platelets encounters a number of different preanalytical issues, which greatly decrease the reliability and accuracy of routine clinical analysis. Modern hematology analyzers determine only four parameters relating to platelets. Platelet shape and dose-dependent activation parameters are outside the scope of commercial instruments. We used the original scanning flow cytometer for measurement of angle-resolved light scattering and the discrete dipole approximation for simulation of light scattering from a platelet optical model, as an oblate spheroid, and global optimization with two algorithms: the DATABASE algorithm to retrieve platelet characteristics from light scattering and the DIRECT algorithm to retrieve dose-dependent activation parameters. We developed the original sampling protocol to decrease spontaneous platelet activation. The new protocol allows us to keep most of the platelets in resting and partially activated states before analysis. The analysis delivers 13 content and morphological parameters of the platelets. To analyze platelet shape change during ADP activation we developed a phenomenological model. This model was applied to the analysis of ADP activation of platelets to give 8 dose-dependent activation parameters. To demonstrate the applicability of the developed protocol and analytical method, we analyzed platelets from five donors. This novel approach to the analysis of platelets allows the determination of 21 parameters relating to their content, morphology and dose-dependent activation.


Assuntos
Plaquetas , Ativação Plaquetária , Simulação por Computador , Citometria de Fluxo , Humanos , Reprodutibilidade dos Testes
19.
Opt Express ; 18(6): 5681-90, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20389584

RESUMO

The discrete sources method (DSM) and the discrete dipole approximation (DDA) were compared for simulation of light scattering by a red blood cell (RBC) model. We considered RBCs with diameters up to 8 mum (size parameter up to 38), relative refractive indices 1.03 and 1.06, and two different orientations. The agreement in the angle-resolved S(11) element of the Mueller matrix obtained by these methods is generally good, but it deteriorates with increasing scattering angle, diameter and refractive index of a RBC. Based on the DDA simulations with very fine discretization (up to 93 dipoles per wavelength) for a single RBC, we attributed most of the disagreement to the DSM, which results contain high-frequency ripples. For a single orientation of a RBC the DDA is comparable to or faster than the DSM. However, the relation is reversed when a set of particle orientations need to be simulated at once. Moreover, the DSM requires about an order of magnitude less computer memory. At present, application of the DSM for massive calculation of light scattering patterns of RBCs is hampered by its limitations in size parameter of a RBC due to the high number of harmonics used for calculations.


Assuntos
Eritrócitos/citologia , Eritrócitos/fisiologia , Iluminação/métodos , Modelos Cardiovasculares , Nefelometria e Turbidimetria/métodos , Simulação por Computador , Luz , Espalhamento de Radiação
20.
J Theor Biol ; 251(1): 93-107, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18083194

RESUMO

A mathematical model of erythrocyte lysis in isotonic solution of ammonium chloride is presented in frames of a statistical approach. The model is used to evaluate several parameters of mature erythrocytes (volume, surface area, hemoglobin concentration, number of anionic exchangers on membrane, elasticity and critical tension of membrane) through their sphering and lysis measured by a scanning flow cytometer (SFC). SFC allows measuring the light-scattering pattern (indicatrix) of an individual cell over the angular range from 10 degrees to 60 degrees . Comparison of the experimentally measured and theoretically calculated light scattering patterns allows discrimination of spherical from non-spherical erythrocytes and evaluation of volume and hemoglobin concentration for individual spherical cells. Three different processes were applied for erythrocytes sphering: (1) colloid osmotic lysis in isotonic solution of ammonium chloride, (2) isovolumetric sphering in the presence of sodium dodecyl sulphate and albumin in neutrally buffered isotonic saline, and (3) osmotic fragility test in hypotonic media. For the hemolysis in ammonium chloride, the evolution of distributions of sphered erythrocytes on volume and hemoglobin content was monitored in real-time experiments. The analysis of experimental data was performed in the context of a statistical approach, taking into account that parameters of erythrocytes vary from cell to cell.


Assuntos
Cloreto de Amônio/toxicidade , Eritrócitos/efeitos dos fármacos , Soluções Isotônicas/toxicidade , Modelos Estatísticos , Adulto , Deformação Eritrocítica , Volume de Eritrócitos , Eritrócitos/patologia , Citometria de Fluxo , Hemólise , Humanos , Masculino , Modelos Biológicos , Fragilidade Osmótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA