Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Catheter Cardiovasc Interv ; 99(3): 736-745, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34761492

RESUMO

BACKGROUND: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) disagree in about 20% of intermediate coronary lesions. As the physiological pattern of coronary artery disease has a significant influence on FFR-iFR discordance, we sought to assess it may impact on the diagnostic accuracy of quantitative flow reserve (QFR). METHODS: One hundred and ninety-four patients with 224 intermediate coronary lesions were investigated with iFR, FFR, and QFR. The physiological pattern of disease was assessed with iFR Scout pullback and QFR virtual pullback in all the cases. RESULTS: A predominantly physiologically focal pattern was observed in 81 (36.2%) lesions, whereas a predominantly physiologically diffuse was observed in 143 (63.8%) cases. QFR demonstrated a significant correlation (r = 0.581, p < 0.001) and a substantial agreement with iFR, both in diffuse (AUC = 0.798) and in focal (AUC = 0.812) pattern of disease. Discordance between QFR and iFR was observed in 51 (22.8%) lesions, consisting of iFR+/QFR- (64.7%) and iFR-/QFR+ (35.3%). Notably, the physiological pattern of disease was the only variable significantly associated with iFR/QFR discordance. QFR virtual pullback demonstrated an excellent agreement (83.9%) with iFR Scout pullback in classifying the physiological pattern of disease. CONCLUSIONS: QFR has a good diagnostic accuracy in assessing myocardial ischemia independently of the pattern of coronary disease. However, the physiological pattern of disease has an influence on the QFR/iFR discordance, which occurs in ~20% of the cases. The QFR virtual pullback correctly defined the physiological pattern of disease in the majority of the cases using the iFR pullback as reference.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Heart ; 110(8): 603-612, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38040448

RESUMO

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Microcirculação , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
3.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-38912744

RESUMO

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Assuntos
Stents Farmacológicos , Humanos , Itália , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia
4.
Am J Cardiol ; 221: 102-109, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Incidência , Idoso , Falha de Prótese , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia
5.
Heart ; 109(10): 785-793, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36598066

RESUMO

OBJECTIVES: We hypothesised that low flow low gradient aortic stenosis (LFLGAS) is associated with more severe coronary microvascular dysfunction (CMD) compared with normal-flow high-gradient aortic stenosis (NFHGAS) and that CMD is related to reduced cardiac performance. METHODS: Invasive CMD assessment was performed in 41 consecutive patients with isolated severe aortic stenosis with unobstructed coronary arteries undergoing transcatheter aortic valve implantation (TAVI). The index of microcirculatory resistance (IMR), resistive reserve ratio (RRR) and coronary flow reserve (CFR) were measured in the left anterior descending artery before and after TAVI. Speckle tracking echocardiography was performed to assess cardiac function at baseline and repeated at 6 months. RESULTS: IMR was significantly higher in patients with LFLGAS compared with patients with NFHGAS (24.1 (14.6 to 39.1) vs 12.8 (8.6 to 19.2), p=0.002), while RRR was significantly lower (1.4 (1.1 to 2.1) vs 2.6 (1.5 to 3.3), p=0.020). No significant differences were observed in CFR between the two groups. High IMR was associated with low stroke volume index, low cardiac output and reduced peak atrial longitudinal strain (PALS). TAVI determined no significant variation in microvascular function (IMR: 16.0 (10.4 to 26.1) vs 16.6 (10.2 to 25.6), p=0.403) and in PALS (15.9 (9.9 to 26.5) vs 20.1 (12.3 to 26.7), p=0.222). Conversely, left ventricular (LV) global longitudinal strain increased after TAVI (-13.2 (8.4 to 16.6) vs -15.1 (9.4 to 17.8), p=0.047). In LFLGAS, LV systolic function recovered after TAVI in patients with preserved microvascular function but not in patients with CMD. CONCLUSIONS: CMD is more severe in patients with LFLGAS compared with NFHGAS and is associated with low-flow state, left atrial dysfunction and reduced cardiac performance.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Estudo de Prova de Conceito , Fibrilação Atrial/complicações , Microcirculação , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico
6.
Int J Cardiovasc Imaging ; 39(1): 233-244, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36336756

RESUMO

Coronary microvascular dysfunction (CMD) has been proposed as a key driver in the etiopathogenesis of Takotsubo syndrome (TTS), likely related to an "adrenergic storm" upon a susceptible microvascular circulation. The aim of our manuscript was to assess CMD in patients with TTS through the computation of the angiography-derived index of microcirculatory resistance (IMR) and its correlation with clinical presentation. Coronary angiograms of 41 consecutive TTS patients were retrospectively analyzed to derive angiography-based indices of CMD. Three indices (NH-IMRangio, AngioIMR and A-IMR) were calculated based on quantitative flow ratio. CMD was defined as an IMRangio value ≥ 25 units. The correlation between CMD and clinical presentation was then assessed. Median age was 76 years, 85.7% were women and mean left ventricular ejection fraction (LVEF) at first echocardiogram was 41.2%. Angiography-derived IMR was higher in left anterior descending artery (LAD) than circumflex and right coronary artery with either NH-IMRangio (53.9 ± 19.8 vs 35.8 ± 15.4 vs 40.8 ± 18.5, p-value < 0.001), AngioIMR (47.2 ± 17.3 vs 31.8 ± 12.2 vs 37.3 ± 13.7, p-value < 0.001) or A-IMR (52.7 ± 19 vs 36.1 ± 14.1 vs 41.8 ± 16.1, p-value < 0.001). All patients presented CMD with angiography-derived IMR ≥ 25 in at least one territory with each formula. Angiography-derived IMR in LAD territory was significantly higher in patients presenting with LVEF impairment (≤ 40%) than in those with preserved ventricular global function (NH-IMRangio: 59.3 ± 18.1 vs 46.3 ± 16.0 p-value = 0.030; AngioIMR: 52.9 ± 17.8 vs 41.4 ± 14.2, p-value = 0.037; A-IMR: 59.2 ± 18.6 vs 46.3 ± 17.0, p-value = 0.035). CMD assessed with angiography-derived IMR is a common finding in TTS and it is inversely correlated with LV function. The available formulas have a substantial superimposable diagnostic performance in assessing coronary microvascular function.


Assuntos
Isquemia Miocárdica , Cardiomiopatia de Takotsubo , Humanos , Feminino , Idoso , Masculino , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Volume Sistólico , Estudos Retrospectivos , Microcirculação , Função Ventricular Esquerda , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária , Resistência Vascular , Circulação Coronária
7.
Clin Res Cardiol ; 112(9): 1331-1342, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37338598

RESUMO

OBJECTIVE: The risk of vessel-oriented cardiac adverse events (VOCE) in patients with diabetes mellitus (DM) undergoing intracoronary physiology-guided coronary revascularization is poorly defined. The purpose of this work is to evaluate the risk of VOCE in patients with and without DM in whom percutaneous coronary intervention (PCI) was performed or deferred based on pressure-wire functional assessment. METHODS: This is a retrospective analysis of a multicenter registry of patients evaluated with fractional flow reserve (FFR) and/or non-hyperaemic pressure ratio (NHPR). Primary endpoint was a composite of VOCE including cardiac death, vessel-related myocardial infarction (MI), and ischemia-driven target vessel revascularization (TVR). RESULTS: A large cohort of 2828 patients with 3353 coronary lesions was analysed to assess the risk of VOCE at long-term follow-up (23 [14-36] months). Non-insulin-dependent-DM (NIDDM) was not associated with the primary endpoint in the overall cohort (adjusted Hazard Ratio [aHR] 1.18, 95% CI 0.87-1.59, P = 0.276) or in patients with coronary lesions treated with PCI (aHR = 1.30, 95% CI 0.78-2.16, P = 0.314). Conversely, insulin-dependent diabetes mellitus (IDDM) demonstrated an increased risk of VOCE in the overall cohort (aHR 1.76, 95% CI 1.07-2.91, P = 0.027), but not in coronary lesions undergoing PCI (aHR 1.26, 95% CI 0.50-3.16, P = 0.621). Importantly, in coronary lesions deferred after functional assessment IDDM (aHR 2.77, 95% CI 1.11-6.93, P = 0.029) but not NIDDM (aHR = 0.94, 95% CI 0.61-1.44, P = 0.776) was significantly associated with the risk of VOCE. IDDM caused a significant effect modification of FFR-based risk stratification (P for interaction < 0.001). CONCLUSION: Overall, DM was not associated with an increased risk of VOCE in patients undergoing physiology-guided coronary revascularization. However, IDDM represents a phenotype at high risk of VOCE.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Estudos Retrospectivos , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio/etiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Angiografia Coronária , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia
8.
Can J Cardiol ; 36(10): 1690.e9-1690.e11, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32360795

RESUMO

A young woman with concomitant symptomatic severe stenosis and regurgitation was managed by percutaneous valve implantation because of a failing mitral homograft in the tricuspid position. The implant procedure was performed using an Edwards S3 23-mm valve. Good hemodynamic results were achieved, and, at intermediate follow-up, she did not require hospitalization and was free of symptoms.


Assuntos
Síndrome de Down/fisiopatologia , Cardiopatias Congênitas , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Valva Mitral , Complicações Pós-Operatórias , Valva Tricúspide , Desfibriladores Implantáveis , Ecocardiografia/métodos , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/cirurgia , Reoperação/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA