Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Am Chem Soc ; 146(2): 1681-1689, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38178655

RESUMO

The coupled relationship between carrier and phonon scattering severely limits the thermoelectric performance of n-type GeTe materials. Here, we provide an efficient strategy to enlarge grains and induce vacancy clusters for decoupling carrier-phonon scattering through the annealing optimization of n-type GeTe-based materials. Specifically, boundary migration is used to enlarge grains by optimizing the annealing time, while vacancy clusters are induced through the aggregation of Ge vacancies during annealing. Such enlarged grains can weaken carrier scattering, while vacancy clusters can strengthen phonon scattering, leading to decoupled carrier-phonon scattering. As a result, a ratio between carrier mobility and lattice thermal conductivity of ∼492.8 cm3 V-1 s-1 W-1 K and a peak ZT of ∼0.4 at 473 K are achieved in Ge0.67Pb0.13Bi0.2Te. This work reveals the critical roles of enlarged grains and induced vacancy clusters in decoupling carrier-phonon scattering and demonstrates the viability of fabricating high-performance n-type GeTe materials via annealing optimization.

2.
Calcif Tissue Int ; 111(2): 211-223, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35588014

RESUMO

Aseptic loosening of the prosthesis caused by wear-particle-induced osteolysis is a long-term complication and one of the most common reasons for the failure of joint implants. The primary cause of aseptic loosening of the prosthesis is overactive bone resorption caused by wear-particle-activated osteoclasts in both direct and indirect ways. Therefore, drugs that can inhibit differentiation and bone resorption of osteoclasts need investigation as a potential therapeutic strategy to prevent and treat peri-prosthetic osteolysis and thereby prolong the service life of the prosthesis. This study has verified the potential inhibitory effect of LY450139 on inflammatory osteolysis induced by titanium particles in a mice skull model. In addition, we found that LY450139 inhibited receptor activator of NF-κB ligand (RANKL)-induced osteoclastogenesis, bone resorption, and podosomal actin belt formation in a dose-dependent manner without evidence of cytotoxicity in vitro. In addition, LY450139 significantly decreased the expression of osteoclast-specific markers, including TRAP, CTSK, V-ATPase d2, CTR, DC-STAMP, NFATc1, and the downstream target gene Hes1 in Notch signaling pathway. Further investigation of the molecular mechanism demonstrated that LY450139 inhibited the formation of osteoclasts via inhibition of the NF-κB and Notch signaling pathways. In summary, LY450139 inhibited the formation of RANKL-mediated osteoclasts via NF-κB and Notch signaling and inhibited Ti particle-induced inflammatory osteolysis in vivo. LY450139 is a potential targeted drug for the treatment of peri-prosthetic osteolysis and other osteolytic disease associated with overactive osteoclasts.


Assuntos
Reabsorção Óssea , Osteólise , Alanina/análogos & derivados , Animais , Azepinas , Reabsorção Óssea/induzido quimicamente , Modelos Animais de Doenças , Camundongos , Camundongos Endogâmicos C57BL , NF-kappa B/metabolismo , Osteoclastos/metabolismo , Osteogênese , Osteólise/tratamento farmacológico , Ligante RANK/metabolismo , Transdução de Sinais , Solubilidade , Titânio/efeitos adversos
3.
BMC Musculoskelet Disord ; 23(1): 432, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-35534887

RESUMO

BACKGROUND: Accurate assessment of acetabular defects and designing precise and feasible surgical plans are essential for positive outcomes of hip revision arthroplasty. Additive manufacturing (AM) is a novel technique to print physical object models. We propose a three-dimensional acetabular bone defect classification system aided with AM model, and further assess its reliability and validity under blinded conditions. METHODS: We reviewed 104 consecutive patients who underwent hip revision arthroplasty at our department between January 2014 and December 2019, of whom 45 had AM models and were included in the reliability and validity tests. Three orthopedic surgeons retrospectively evaluated the bone defects of these 45 patients with our proposed classification, made surgical plans, and repeated the process after 2 weeks. The reliability and validity of the classification results and corresponding surgical plans were assessed using the intra-class correlation coefficient or kappa correlation coefficient. RESULTS: The reliability and validity of the classification results were excellent. The mean initial intra-class correlation coefficient for inter-observer reliability was 0.947, which increased to 0.972 when tested a second time. The intra-observer reliability ranged from 0.958 to 0.980. Validity of the classification results also showed a high kappa correlation coefficient of 0.951-0.967. When considering corresponding surgical plans, the reliability and validity were also excellent, with intra-class correlation coefficients and kappa correlation coefficients measuring all over 0.9. CONCLUSIONS: This three-dimensional acetabular defect classification has excellent reliability and validity. Using this classification system and AM models, accurate assessment of bone defect and reliable surgical plans could be achieved. This classification aided with AM is a promising tool for surgeons for preoperative evaluation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Humanos , Variações Dependentes do Observador , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
BMC Musculoskelet Disord ; 23(1): 437, 2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35546655

RESUMO

BACKGROUND: Mechanical failure, power shortage, and inadvertent contamination of the oscillating saw occasionally occurs in actualizing femoral neck osteotomy during total hip arthroplasty (THA); however, no appropriate alternative solution is currently available. This study aimed to introduce a novel osteotomy instrumentation (fretsaw, jig, cable passer hook) as a substitute tool while the oscillating saw was unavailable during THA. METHODS: This study included 40 patients (40 hips) who underwent femoral neck osteotomy during primary THA using the new osteotomy instrumentation (n = 20) and the oscillating saw (n = 20). Clinical data and intraoperative findings of all patients were evaluated. RESULTS: The mean osteotomy time was 22.3 ± 3.1 s (range, 17-30 s) and 29.4 ± 3.7 s (range, 25-39 s) in the oscillating saw group and in the new osteotomy instrumentation group, respectively (P < 0.001). The Harris Hip Score (HHS) improved in both groups; the mean HSS was 82.3 ± 2.5 and 83.3 ± 3.5 in the oscillating saw group and new osteotomy instrumentation group at 6 months after surgery, respectively (P = 0.297). CONCLUSIONS: The original osteotomy instrumentation can be an ideal substitute tool for femoral neck osteotomy in THA, especially when the oscillating saw is unavailable or malfunctioning.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Humanos , Osteotomia , Estudos Retrospectivos , Resultado do Tratamento
5.
J Arthroplasty ; 37(3): 538-543, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34923094

RESUMO

BACKGROUND: This study aimed to explore the anatomical correlation between the femoral neck shaft angle (NSA) and femoral anteversion angle (AA) in patients with developmental dysplasia of the hip based on the Crowe classification and provide a novel method to estimate the femoral AA on anteroposterior pelvic radiographs. METHODS: A total of 208 patients with dysplastic hips who underwent total hip arthroplasty at our institution were retrospectively included. Preoperative physiological AA and NSA were determined via 3-dimensional computed tomography. Linear regressions and Pearson's coefficients were calculated to assess the correlation between the femoral NSA and femoral AA. RESULTS: A total of 416 hips were divided into 5 subgroups: 99 normal, 143 type I, 71 type II, 63 type III, and 40 type IV hips following the Crowe classification. Dysplastic femurs had significantly higher AAs than normal hips (25.2° vs 31.4° vs 33.3° vs 35.5° vs 41.7°). Significant positive correlations between the AA and NSA were observed in normal (r = 0.635), type I (r = 0.700), type II (r = 0.612), and type III (r = 0.638) hips (P < .001); however, no meaningful correlation was observed in type IV hips (r = 0.218, P = .176). CONCLUSION: The NSA and AA correlated positively and significantly in the normal and dysplastic Crowe type I-III hips. The relationship between the NSA and AA indicates torsion of the proximal femur and offers an opportunity for straightforward estimation of AA based on NSA.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
J Nanobiotechnology ; 19(1): 11, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413447

RESUMO

BACKGROUND: Breast cancer bone metastasis has become one of the most common complications; however, it may cause cancer recurrence and bone nonunion, as well as local bone defects. METHODS: Herein, In vitro, we verified the effect of bioscaffold materials on cell proliferation and apoptosis through a CCK8 trial, staining of live/dead cells, and flow cytometry. We used immunofluorescence technology and flow cytometry to verify whether bioscaffold materials regulate macrophage polarization, and we used ALP staining, alizarin red staining and PCR to verify whether bioscaffold material promotes bone regeneration. In vivo, we once again studied the effect of bioscaffold materials on tumors by measuring tumor volume in mice, Tunel staining, and caspase-3 immunofluorescence. We also constructed a mouse skull ultimate defect model to verify the effect on bone regeneration. RESULTS: Graphene oxide (GO) nanoparticles, hydrated CePO4 nanorods and bioactive chitosan (CS) are combined to form a bioactive multifunctional CePO4/CS/GO scaffold, with characteristics such as photothermal therapy to kill tumors, macrophage polarization to promote blood vessel formation, and induction of bone formation. CePO4/CS/GO scaffold activates the caspase-3 proteasein local tumor cells, thereby lysing the DNA between nucleosomes and causing apoptosis. On the one hand, the as-released Ce3+ ions promote M2 polarization of macrophages, which secretes vascular endothelial growth factor (VEGF) and Arginase-1 (Arg-1), which promotes angiogenesis. On the other hand, the as-released Ce3+ ions also activated the BMP-2/Smad signaling pathway which facilitated bone tissue regeneration. CONCLUSION: The multifunctional CePO4/CS/GO scaffolds may become a promising platform for therapy of breast cancer bone metastases.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Cério/química , Grafite/farmacologia , Nanotubos/química , Fosfatos/química , Células 3T3 , Animais , Materiais Biocompatíveis , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/metabolismo , Regeneração Óssea , Osso e Ossos , Neoplasias da Mama/metabolismo , Proliferação de Células , Quitosana , Modelos Animais de Doenças , Feminino , Macrófagos , Camundongos , Metástase Neoplásica , Osteogênese , Células RAW 264.7 , Ratos , Ratos Sprague-Dawley , Fator A de Crescimento do Endotélio Vascular
7.
J Nanobiotechnology ; 19(1): 298, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34592996

RESUMO

BACKGROUND: Hypoxia is a characteristic of solid tumors that can lead to tumor angiogenesis and early metastasis, and addressing hypoxia presents tremendous challenges. In this work, a nanomedicine based on oxygen-absorbing perfluorotributylamine (PFA) and the bioreductive prodrug tirapazamine (TPZ) was prepared by using a polydopamine (PDA)-coated UiO-66 metal organic framework (MOF) as the drug carrier. RESULTS: The results showed that TPZ/PFA@UiO-66@PDA nanoparticles significantly enhanced hypoxia, induced cell apoptosis in vitro through the oxygen-dependent HIF-1α pathway and decreased oxygen levels in vivo after intratumoral injection. In addition, our study demonstrated that TPZ/PFA@UiO-66@PDA nanoparticles can accumulate in the tumor region after tail vein injection and effectively inhibit tumor growth when combined with photothermal therapy (PTT). TPZ/PFA@UiO-66@PDA nanoparticles increased HIF-1α expression while did not promote the expression of CD31 in vivo during the experiment. CONCLUSIONS: By using TPZ and PFA and the enhanced permeability and retention effect of nanoparticles, TPZ/PFA@UiO-66@PDA can target tumor tissues, enhance hypoxia in the tumor microenvironment, and activate TPZ. Combined with PTT, the growth of osteosarcoma xenografts can be effectively inhibited.


Assuntos
Fluorocarbonos , Estruturas Metalorgânicas , Osteossarcoma/metabolismo , Ácidos Ftálicos , Tirapazamina , Hipóxia Tumoral , Animais , Antineoplásicos/química , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Fluorocarbonos/química , Fluorocarbonos/farmacologia , Humanos , Indóis/química , Indóis/farmacologia , Masculino , Estruturas Metalorgânicas/química , Estruturas Metalorgânicas/farmacologia , Camundongos , Camundongos Nus , Nanopartículas/química , Nanopartículas/toxicidade , Ácidos Ftálicos/química , Ácidos Ftálicos/farmacologia , Polímeros/química , Polímeros/farmacologia , Tirapazamina/química , Tirapazamina/farmacologia
8.
J Cell Mol Med ; 24(5): 3203-3216, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32053272

RESUMO

Aseptic loosening caused by wear particles is a common complication after total hip arthroplasty. We investigated the effect of the quercetin on wear particle-mediated macrophage polarization, inflammatory response and osteolysis. In vitro, we verified that Ti particles promoted the differentiation of RAW264.7 cells into M1 macrophages through p-38α/ß signalling pathway by using flow cytometry, immunofluorescence assay and small interfering p-38α/ß RNA. We used enzyme-linked immunosorbent assays to confirm that the protein expression of M1 macrophages increased in the presence of Ti particles and that these pro-inflammatory factors further regulated the imbalance of OPG/RANKL and promoted the differentiation of osteoclasts. However, this could be suppressed, and the protein expression of M2 macrophages was increased by the presence of the quercetin. In vivo, we revealed similar results in the mouse skull by µ-CT, H&E staining, immunohistochemistry and immunofluorescence assay. We obtained samples from patients with osteolytic tissue. Immunofluorescence analysis indicated that most of the macrophages surrounding the wear particles were M1 macrophages and that pro-inflammatory factors were released. Titanium particle-mediated M1 macrophage polarization, which caused the release of pro-inflammatory factors through the p-38α/ß signalling pathway, regulated OPG/RANKL balance. Macrophage polarization is expected to become a new clinical drug therapeutic target.


Assuntos
Osteonecrose/tratamento farmacológico , Osteoprotegerina/genética , Quercetina/farmacologia , Ligante RANK/genética , Proteínas Quinases p38 Ativadas por Mitógeno/genética , Animais , Artroplastia de Quadril/efeitos adversos , Diferenciação Celular/efeitos dos fármacos , Polaridade Celular/efeitos dos fármacos , Regulação da Expressão Gênica no Desenvolvimento/efeitos dos fármacos , Humanos , Macrófagos/efeitos dos fármacos , Camundongos , Osteoclastos/efeitos dos fármacos , Osteonecrose/induzido quimicamente , Osteonecrose/genética , Osteonecrose/patologia , Células RAW 264.7 , Crânio/efeitos dos fármacos , Crânio/crescimento & desenvolvimento , Crânio/patologia , Titânio/efeitos adversos
9.
J Arthroplasty ; 35(2): 457-464, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31668697

RESUMO

BACKGROUND: Preoperative planning is fundamental for total hip arthroplasty. This study investigated the optimal femoral neck level for measuring femoral anteversion to predict postoperative stem anteversion in developmental dysplasia of the hip and determined the predictive role of average anteversion based on the sagittal 3-point fixation. METHODS: Sixty-two Crowe type II/III dysplastic hips that underwent total hip arthroplasty were retrospectively analyzed. Preoperative and postoperative anteversion was measured via 2-dimensional computed tomography. Anterior and posterior cortex anteversions were measured at 6 levels of the proximal femur. Femoral anteversion at each level was calculated. Average anterior (lesser trochanter) and posterior cortex anteversions (femoral neck) were calculated based on the sagittal 3-point fixation. RESULTS: From the lesser trochanter to head-neck junction, femoral anteversion decreased gradually from more to less than stem anteversion. For hips with femoral neck height ≥10 mm, femoral anteversion at the 10-mm level above the lesser trochanter proximal base showed no significant difference with stem anteversion, with a good correlation for the single-wedge and an excellent correlation for the double-wedge stem. Average anterior (lesser trochanter proximal base) and posterior cortex anteversions (femoral neck at 10 mm above the lesser trochanter proximal base) showed no significant difference from stem anteversion, with excellent correlations. CONCLUSION: For Crowe type II/III hips with femoral neck height ≥10 mm, the 10-mm level above the lesser trochanter proximal base is an optimal choice for measuring femoral anteversion to predict postoperative stem anteversion. The average of anterior cortex anteversion at the lesser trochanter and posterior cortex anteversion at the femoral neck has a predictive role.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Humanos , Estudos Retrospectivos
10.
Hereditas ; 156: 17, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31178673

RESUMO

BACKGROUND: Evidence is accumulating to characterise the key differences between systemic sclerosis (SSc) and rheumatoid arthritis (RA), which are similar but distinct systemic autoimmune diseases. However, the differences at the genetic level are not yet clear. Therefore, the aim of the present study was to identify key differential genes between patients with SSc and RA. METHODS: The Gene Expression Omnibus database was used to identify differentially expressed genes (DEGs) between SSc and RA biopsies. The DEGs were then functionally annotated using Gene Ontology (GO) terms and the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways with the Database for Annotation, Visualization and Integrated Discovery (DAVID) tools. A protein-protein interaction (PPI) network was constructed with Cytoscape software. The Molecular Complex Detection (MCODE) plugin was also used to evaluate the biological importance of the constructed gene modules. RESULTS: A total of 13,556 DEGs were identified between the five SSc patients and seven RA patients, including 13,465 up-regulated genes and 91 down-regulated genes. Interestingly, the most significantly enriched GO terms of up- and down-regulated genes were related to extracellular involvement and immune activity, respectively, and the top six highly enriched KEGG pathways were related to the same processes. In the PPI network, the top 10 hub nodes and top four modules harboured the most relevant genes contributing to the differences between SSc and RA, including key genes such as IL6, EGF, JUN, FGF2, BMP2, FOS, BMP4, LRRK2, CTNNB1, EP300, CD79, and CXCL13. CONCLUSIONS: These genes such as IL6, EGF, JUN, FGF2, BMP2, FOS, BMP4, LRRK2, CTNNB1, EP300, CD79, and CXCL13 can serve as new targets for focused research on the distinct molecular pathogenesis of SSc and RA. Furthermore, these genes could serve as potential biomarkers for differential diagnoses or therapeutic targets for treatment.


Assuntos
Artrite Reumatoide/genética , Regulação da Expressão Gênica , Escleroderma Sistêmico/genética , Artrite Reumatoide/metabolismo , Biomarcadores , Biologia Computacional/métodos , Bases de Dados Genéticas , Perfilação da Expressão Gênica , Humanos , Anotação de Sequência Molecular , Mapeamento de Interação de Proteínas , Mapas de Interação de Proteínas , Escleroderma Sistêmico/metabolismo , Transdução de Sinais , Transcriptoma
11.
Nanomedicine ; 18: 336-346, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30419364

RESUMO

Bioglass scaffolds have great application potentials in orthopedics, and Ursolic acid (UA) can effectively promote in vivo new bone formation. Herein, we for the first time developed the mesoporous bioglass/chitosan porous scaffolds loaded with UA (MBG/CS/UA) for enhanced bone regeneration. The MBG microspheres with particle sizes of ~300 nm and pore sizes of ~3.9 nm were uniformly dispersed on the CS films. The mesoporous structure within the MBG microspheres and the hydrogen bonding between the scaffolds and UA drugs made the MBG/CS/UA scaffolds have controlled drug release performances. The as-released UA drugs from the scaffolds increased remarkably the alkaline phosphatase activity, osteogenic differentiation related gene type I collagen, runt-related transcription factor 2 expression, and osteoblast-associated protein expression. Moreover, the results of micro-CT images, histomorphological observations demonstrated that the MBG/CS/UA scaffolds improved new bone formation ability. Therefore, the MBG/CS/UA porous scaffolds can be used as novel bone tissue engineering materials.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Cerâmica/química , Quitosana/química , Sistemas de Liberação de Medicamentos , Alicerces Teciduais/química , Triterpenos/farmacologia , Animais , Linhagem Celular , Colágeno Tipo I/metabolismo , Subunidade alfa 1 de Fator de Ligação ao Core/metabolismo , Liberação Controlada de Fármacos , Feminino , Humanos , Camundongos , Microesferas , Osseointegração/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Porosidade , Ratos Sprague-Dawley , Ácido Ursólico
12.
J Arthroplasty ; 32(3): 849-856, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27919583

RESUMO

BACKGROUND: This study compares the outcome between THA with and without femoral shortening osteotomy for unilateral mild to moderate high hip dislocation in developmental dysplasia of the hip patients. METHODS: The data on 42 hips in 42 patients who had undergone THA for unilateral mild to moderate high hip dislocation were retrospectively reviewed after being prospectively collected. In 22 patients, hips were reduced by soft tissue release and direct leverage using an elevator, without the osteotomy. The remaining 20 patients were treated with a subtrochanteric transverse shortening osteotomy. The mean follow-up of patients was 5 years (standard deviation = 1.0) for the nonosteotomy group and 6.2 years (standard deviation = 1.6) for the osteotomy group. RESULTS: The Harris Hip Score significantly improved in both groups. In the nonosteotomy group, we observed a lower leg length discrepancy compared with the osteotomy group (0.4 cm and 2.2 cm, respectively). Four patients (18.2%) in the nonosteotomy group and 15 patients (75%) in the osteotomy group developed a limp (P < .0001). Three patients (13%) developed femoral nerve palsy in the nonosteotomy group, but they all recovered completely within 6 months after the surgery. Nineteen patients in the nonosteotomy group showed knee valgus deformity immediately after the surgery but only 4 cases in the osteotomy group. CONCLUSION: Compared with THA with femoral shortening osteotomy, THA without the osteotomy was associated with a lower number of patients who developed a limp at the end of follow-up; however, the rehabilitation was slower and more difficult, and a larger number of patients showed reversible nerve palsy and knee valgus deformity.


Assuntos
Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Adulto , Idoso , Feminino , Fêmur/cirurgia , Luxação do Quadril/cirurgia , Humanos , Articulação do Joelho , Desigualdade de Membros Inferiores , Masculino , Pessoa de Meia-Idade , Osteotomia , Estudos Retrospectivos
13.
J Arthroplasty ; 32(4): 1374-1380, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27956127

RESUMO

BACKGROUND: Recommendations for minimum cup coverage based on anteroposterior radiographs are widely used as an intraoperative guide in total hip arthroplasty for patients with developmental dysplasia of the hip. The purpose of this study was to examine the validity of two-dimensional (2D) measurement of coverage with three-dimensional (3D) coverage and to identify parameters for determining the 3D coverage during surgery. METHODS: We developed a technique to accurately reproduce the intraoperative anatomic geometry of the dysplastic acetabulum and measure the 3D cup coverage postoperatively. With this technique, we retrospectively analyzed the difference and correlation between 2D and 3D measurements of native bone coverage in 35 patients (45 hips) with Crowe II or III DDH. Linear regression analysis was performed to examine the intraoperative parameters related to coverage. The mean follow-up period was 7.64 years (range, 6.1-9.5 years). RESULTS: There was a significant difference and a fair correlation between 2D and 3D measurements. The 2D measurement underestimated the 3D cup coverage by approximately 13%. An excellent linear relationship was noted between the 3D coverage/uncoverage and the height of the uncovered portion (R2 = 0.8440, P < .0001). There was no case of loosening or revision during the follow-up. CONCLUSION: Current minimum cup coverage recommendations based on 2D radiograph measurements should not be used as a direct intraoperative guide. The height of the uncovered portion is a useful parameter to determine the 3D coverage during surgery.


Assuntos
Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Acetábulo/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Radiografia , Estudos Retrospectivos , Adulto Jovem
14.
Clin Exp Rheumatol ; 34(5): 929-934, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27606839

RESUMO

Subchondral bone has received increasing attention in both basic and clinical research on osteoarthritis (OA). Subchondral bone in OA presents abnormalities in structure, biochemical composition, biomechanics and cellular function. Overall, subchondral bone mainly shows bone resorption in early OA and bone formation in late OA. More and more evidence suggests that abnormalities in subchondral bone of OA promote joint pain generation and articular cartilage degeneration. Inhibition or amelioration of subchondral bone abnormalities can reduce joint pain and can delay cartilage degeneration; thus, subchondral bone-targeted treatment promises to be a new treatment approach for OA. The pathological changes and the role of subchondral bone in OA still require further investigation.


Assuntos
Artralgia/etiologia , Remodelação Óssea , Cartilagem Articular/patologia , Articulações/patologia , Osteoartrite/patologia , Animais , Artralgia/patologia , Artralgia/fisiopatologia , Artralgia/prevenção & controle , Fenômenos Biomecânicos , Conservadores da Densidade Óssea/uso terapêutico , Remodelação Óssea/efeitos dos fármacos , Cartilagem Articular/efeitos dos fármacos , Cartilagem Articular/fisiopatologia , Humanos , Articulações/efeitos dos fármacos , Articulações/fisiopatologia , Osteoartrite/complicações , Osteoartrite/tratamento farmacológico , Osteoartrite/fisiopatologia , Fatores de Risco
16.
Clin Orthop Relat Res ; 474(3): 731-40, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26467611

RESUMO

BACKGROUND: Revision THA is particularly challenging in hips with severe acetabular bone loss. When the extent or geometry of the acetabular bone loss precludes more-straightforward techniques such as jumbo hemispheric cementless shells, reconstruction with morselized allograft protected by a custom cage may offer an alternative, but, to our knowledge, few series have reported on results with this approach. QUESTIONS/PURPOSES: For patients with severe (Paprosky IIIB) defects, we asked: do individualized custom cages result in (1) improved Harris hip scores; (2) restoration of hip center; and (3) a low incidence of surgical complications? METHODS: Twenty-six patients (26 hips) with a massive acetabular defect were involved in this study from 2003 to 2013. During this period, one patient was lost to followup and one died, leaving 24 patients (eight males, 16 females) in this retrospective analysis. The customized cages were individualized to each patient's bone defect based on rapid-prototype three-dimensional printed models. Mean followup was 67 months (range, 24-120 months). Harris hip scores were assessed before surgery and at each followup. Postoperative radiographs were evaluated for cage position, migration, and graft incorporation. Complications and reoperations were assessed by chart review. RESULTS: The mean Harris hip score improved from 36 (SD, 8; range, 20-49) to 82 (SD, 18; range, 60-96) (p < 0.001). Individualized custom cages resulted in generally reliable restoration of the hip center. No rerevisions have been performed. None of the cups showed radiographic migration, but one cage was believed to be loose, based on a circumferential 2-mm radiolucent line. Cancellous allografts appeared to be incorporated in 23 of 24 patients. One deep infection and one superficial infection were observed and treated with irrigation, débridement, and vacuum-sealing drainage. One dislocation and one suspected injury of the superior gluteal nerve also were observed and treated conservatively. CONCLUSIONS: Individualized custom cages using rapid prototyping and three-dimensional printing appeared to provide stable fixation and improved hip scores at short-term followup in this small, single-center series. As further improvements in the design and manufacturing process are made, future studies should evaluate larger patient groups for longer times, and, ideally, compare this approach with alternatives for these complex bone defects. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/patologia , Idoso , Avaliação da Deficiência , Feminino , Humanos , Fixadores Internos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Impressão Tridimensional , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
J Arthroplasty ; 31(6): 1233-1239, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26774406

RESUMO

BACKGROUND: We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. METHODS: Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). RESULTS: On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. CONCLUSION: This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Luxação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Cimentos Ósseos , Cerâmica , Feminino , Luxação do Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Pelve/cirurgia , Tomografia Computadorizada por Raios X
18.
J Arthroplasty ; 31(4): 850-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26681646

RESUMO

PURPOSES: To examine the clinical outcomes of patients treated with a nickel-titanium shape-memory sawtooth-arm embracing clamp (Ni-Ti SSEC) in complex femoral revision surgery. METHODS: We retrospectively evaluated the outcomes for 21 complex femoral revision hip arthroplasties that we treated using an Ni-Ti SSEC. The Ni-Ti SSEC was used for various procedures, including the fixation of extremely long cortical windows (11 patients), femoral shaft osteotomy (4 patients), an extended trochanteric osteotomy (3 patients), and protection of a penetrated femoral cortex by a primary stem (3 patients). All patients received follow-up care for an average of 48.2 months. RESULTS: The mean time of Ni-Ti SSEC insertion intraoperatively was 6 minutes. The mean Harris Hip Score improved from 21.2 points before revision surgery to 83.1 points at the most recent examination. No implant failures or malunions occurred. Dislocation and deep infection occurred in 1 case during the follow-up period. CONCLUSIONS: Our results show that the embracing clamp is a simple and valid method for fixing osteotomies in treating complex femoral revision surgery.


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/cirurgia , Prótese de Quadril , Adulto , Idoso , Artroplastia de Quadril/métodos , Materiais Biocompatíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Níquel , Osteotomia/instrumentação , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Titânio , Adulto Jovem
19.
J Arthroplasty ; 30(12): 2248-55, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26228491

RESUMO

The combined anteversion surgical technique has been proposed and used in clinical practice. To more objectively evaluate the feasibility of this surgical technique using combined anteversion concept for DDH patients, we studied 34 DDH patients (40 hips) in this research. Every patient underwent pelvic CT scans before and after surgery and the HHSs were recorded. Optimal range of joint motion was measured using a three-dimensional reconstruction technique and a dynamic measurement technique. The results revealed that joint function met the requirements of daily life and the range of motion was not over-limited by impingement between the prosthesis and the skeleton. Moreover, the combined anteversion was found to be the most critical parameter in this study.


Assuntos
Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Articulação do Quadril/fisiologia , Amplitude de Movimento Articular , Idoso , Feminino , Quadril/cirurgia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Pelve/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
20.
Int Orthop ; 39(10): 2023-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26285669

RESUMO

PURPOSE: Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. METHODS: Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. RESULTS: The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. CONCLUSIONS: The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Reabsorção Óssea/cirurgia , Articulação do Quadril/cirurgia , Artropatias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Transplante Ósseo , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Impressão Tridimensional , Cintilografia , Reoperação , Cirurgia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA