Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(11): e14165, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37782250

RESUMO

Non-coplanar radiotherapy treatment techniques on C-arm linear accelerators have the potential to reduce dose to organs-at-risk in comparison with coplanar treatment techniques. Accurately predicting possible collisions between gantry, table and patient during treatment planning is needed to ensure patient safety. We offer a freely available collision prediction tool using Blender, a free and open-source 3D computer graphics software toolset. A geometric model of a C-arm linear accelerator including a library of patient models is created inside Blender. Based on the model, collision predictions can be used both to calculate collision-free zones and to check treatment plans for collisions. The tool is validated for two setups, once with and once without a full body phantom with the same table position. For this, each gantry-table angle combination with a 2° resolution is manually checked for collision interlocks at a TrueBeam system and compared to simulated collision predictions. For the collision check of a treatment plan, the tool outputs the minimal distance between the gantry, table and patient model and a video of the movement of the gantry and table, which is demonstrated for one use case. A graphical user interface allows user-friendly input of the table and patient specification for the collision prediction tool. The validation resulted in a true positive rate of 100%, which is the rate between the number of correctly predicted collision gantry-table combinations and the number of all measured collision gantry-table combinations, and a true negative rate of 89%, which is the ratio between the number of correctly predicted collision-free combinations and the number of all measured collision-free combinations. A collision prediction tool is successfully created and able to produce maps of collision-free zones and to test treatment plans for collisions including visualisation of the gantry and table movement.


Assuntos
Comportamento de Utilização de Ferramentas , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
2.
Int J Mol Sci ; 24(17)2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37686468

RESUMO

Both FoxO transcription factors and the circadian clock act on the interface of metabolism and cell cycle regulation and are important regulators of cellular stress and stem cell homeostasis. Importantly, FoxO3 preserves the adult neural stem cell population by regulating cell cycle and cellular metabolism and has been shown to regulate circadian rhythms in the liver. However, whether FoxO3 is a regulator of circadian rhythms in neural stem cells remains unknown. Here, we show that loss of FoxO3 disrupts circadian rhythmicity in cultures of neural stem cells, an effect that is mediated via regulation of Clock transcriptional levels. Using Rev-Erbα-VNP as a reporter, we then demonstrate that loss of FoxO3 does not disrupt circadian rhythmicity at the single cell level. A meta-analysis of published data revealed dynamic co-occupancy of multiple circadian clock components within FoxO3 regulatory regions, indicating that FoxO3 is a Clock-controlled gene. Finally, we examined proliferation in the hippocampus of FoxO3-deficient mice and found that loss of FoxO3 delayed the circadian phase of hippocampal proliferation, indicating that FoxO3 regulates correct timing of NSC proliferation. Taken together, our data suggest that FoxO3 is an integral part of circadian regulation of neural stem cell homeostasis.


Assuntos
Relógios Circadianos , Ritmo Circadiano , Proteína Forkhead Box O3 , Células-Tronco Neurais , Animais , Camundongos , Ciclo Celular , Divisão Celular , Relógios Circadianos/genética , Ritmo Circadiano/genética , Proteína Forkhead Box O3/genética , Proteína Forkhead Box O3/fisiologia
3.
Medicina (Kaunas) ; 56(12)2020 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-33348865

RESUMO

Urothelial carcinoma (UC) is the fourth most frequent tumor in Western countries and upper tract urothelial carcinoma (UTUC), affecting pyelocaliceal cavities and ureter, accounts for 5-10% of all UCs. Computed tomography urography (CTU) is now considered the imaging modality of choice for diagnosis and staging of UTUC, guiding disease management. Although its specificity is very high, both benign and malignant diseases could mimic UTUCs and therefore have to be well-known to avoid misdiagnosis. We describe CTU findings of upper urinary tract carcinoma, features that influence disease management, and possible differential diagnosis.


Assuntos
Carcinoma de Células de Transição , Ureter , Neoplasias Urológicas , Carcinoma de Células de Transição/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X , Urografia , Neoplasias Urológicas/diagnóstico por imagem
4.
Proc Natl Acad Sci U S A ; 113(45): E7087-E7096, 2016 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-27791111

RESUMO

The forkhead transcription factor FoxO6 is prominently expressed during development of the murine neocortex. However, its function in cortical development is as yet unknown. We now demonstrate that cortical development is altered in FoxO6+/- and FoxO6-/- mice, showing migrating neurons halted in the intermediate zone. Using a FoxO6-directed siRNA approach, we substantiate the requirement of FoxO6 for a correct radial migration in the developing neocortex. Subsequent genome-wide transcriptome analysis reveals altered expression of genes involved in cell adhesion, axon guidance, and gliogenesis upon silencing of FoxO6 We then show that FoxO6 binds to DAF-16-binding elements in the Plexin A4 (Plxna4) promoter region and affects Plxna4 expression. Finally, ectopic Plxna4 expression restores radial migration in FoxO6+/- and siRNA-mediated knockdown models. In conclusion, the presented data provide insights into the molecular mechanisms whereby transcriptional programs drive cortical development.

5.
Arterioscler Thromb Vasc Biol ; 36(4): 673-81, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26891740

RESUMO

OBJECTIVE: To understand the anatomy and physiology of ascending aortic aneurysms in angiotensin II-infused ApoE(-/-) mice. APPROACH AND RESULTS: We combined an extensive in vivo imaging protocol (high-frequency ultrasound and contrast-enhanced microcomputed tomography at baseline and after 3, 10, 18, and 28 days of angiotensin II infusion) with synchrotron-based ultrahigh resolution ex vivo imaging (phase contrast X-ray tomographic microscopy) in n=47 angiotensin II-infused mice and 6 controls. Aortic regurgitation increased significantly over time, as did the luminal volume of the ascending aorta. In the samples that were scanned ex vivo, we observed one or several focal dissections, with the largest located in the outer convex aspect of the ascending aorta. The volume of the dissections moderately correlated to the volume of the aneurysm as measured in vivo (r(2)=0.46). After 3 days of angiotensin II infusion, we found an interlaminar hematoma in 7/12 animals, which could be linked to an intimal tear. There was also a significant increase in single laminar ruptures, which may have facilitated a progressive enlargement of the focal dissections over time. At later time points, the hematoma was resorbed and the medial and adventitial thickness increased. Fatal transmural dissection occurred in 8/47 mice at an early stage of the disease, before adventita remodeling. CONCLUSIONS: We visualized and quantified the dissections that lead to ascending aortic aneurysms in angiotensin II-infused mice and provided unique insight into the temporal evolution of these lesions.


Assuntos
Aorta/patologia , Aneurisma da Aorta Abdominal/patologia , Dissecção Aórtica/patologia , Ruptura Aórtica/patologia , Remodelação Vascular , Dissecção Aórtica/induzido quimicamente , Dissecção Aórtica/diagnóstico por imagem , Angiotensina II , Animais , Aorta/diagnóstico por imagem , Aorta/metabolismo , Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/induzido quimicamente , Ruptura Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Aortografia/métodos , Apolipoproteínas E/deficiência , Apolipoproteínas E/genética , Dilatação Patológica , Modelos Animais de Doenças , Progressão da Doença , Tecido Elástico/patologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Fatores de Tempo , Ultrassonografia Doppler de Pulso , Microtomografia por Raio-X
6.
J Cell Physiol ; 230(5): 1013-23, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25216324

RESUMO

FoxK2 is a forkhead transcription factor expressed ubiquitously in the developing murine central nervous system. Here we investigated the role of FoxK2 in vitro and focused on proliferation and cellular survival. Knockdown of FoxK2 results in a decrease in BrdU incorporation and H3 phosphorylation, suggesting attenuation of proliferation. In the absence of growth factors, FoxK2 knockdown results in a dramatic increase in caspase 3 activity and propidium iodide positive cells, indicative of cell death. Additionally, knockdown of FoxK2 results in an increase in the mRNA of Gadd45α, Gadd45γ, as well as an increase in the phosphorylation of the mTOR dependent kinase p70S6K. Rapamycin treatment completely blocked the increase in p70S6K and synergistically potentiated the decrease in H3 phosphorylation upon FoxK2 knockdown. To gain more insight into the proapoptotic effects upon FoxK2 knockdown we screened for changes in Bcl2 genes. Upon FoxK2 knockdown both Puma and Noxa were significantly upregulated. Both genes were not inhibited by rapamycin treatment, instead rapamycin increased Noxa mRNA. FoxK2 requirement in cellular survival is further emphasized by the fact that resistance to TGFß-induced cell death was greatly diminished after FoxK2 knockdown. Overall our data suggest FoxK2 is required for proliferation and survival, that mTOR is part of a feedback loop partly compensating for FoxK2 loss, possibly by upregulating Gadd45s, whereas cell death upon FoxK2 loss is induced in a Bcl2 dependent manner via Puma and Noxa.


Assuntos
Fatores de Transcrição Forkhead/metabolismo , Animais , Morte Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Técnicas de Silenciamento de Genes , Células HEK293 , Histonas/metabolismo , Humanos , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Espaço Intracelular/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Modelos Biológicos , Células NIH 3T3 , Fosforilação/efeitos dos fármacos , Transporte Proteico/efeitos dos fármacos , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , RNA Interferente Pequeno/metabolismo , Reprodutibilidade dos Testes , Proteínas Quinases S6 Ribossômicas 70-kDa/metabolismo , Serina-Treonina Quinases TOR/metabolismo , Fator de Crescimento Transformador beta/farmacologia , Proteínas GADD45
7.
Phys Imaging Radiat Oncol ; 30: 100586, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38808098

RESUMO

Background and purpose: Dynamic trajectory radiotherapy (DTRT) has been shown to improve healthy tissue sparing compared to volumetric arc therapy (VMAT). This study aimed to assess and compare the robustness of DTRT and VMAT treatment-plans for head and neck (H&N) cancer to patient-setup (PS) and machine-positioning uncertainties. Materials and methods: The robustness of DTRT and VMAT plans previously created for 46 H&N cases, prescribed 50-70 Gy to 95 % of the planning-target-volume, was assessed. For this purpose, dose distributions were recalculated using Monte Carlo, including uncertainties in PS (translation and rotation) and machine-positioning (gantry-, table-, collimator-rotation and multi-leaf collimator (MLC)). Plan robustness was evaluated by the uncertainties' impact on normal tissue complication probabilities (NTCP) for xerostomia and dysphagia and on dose-volume endpoints. Differences between DTRT and VMAT plan robustness were compared using Wilcoxon matched-pair signed-rank test (α = 5 %). Results: Average NTCP for moderate-to-severe xerostomia and grade ≥ II dysphagia was lower for DTRT than VMAT in the nominal scenario (0.5 %, p = 0.01; 2.1 %, p < 0.01) and for all investigated uncertainties, except MLC positioning, where the difference was not significant. Average differences compared to the nominal scenario were ≤ 3.5 Gy for rotational PS (≤ 3°) and machine-positioning (≤ 2°) uncertainties, <7 Gy for translational PS uncertainties (≤ 5 mm) and < 20 Gy for MLC-positioning uncertainties (≤ 5 mm). Conclusions: DTRT and VMAT plan robustness to the investigated uncertainties depended on uncertainty direction and location of the structure-of-interest to the target. NTCP remained on average lower for DTRT than VMAT even when considering uncertainties.

8.
Med Phys ; 51(2): 1326-1339, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38131614

RESUMO

BACKGROUND: Non-coplanar techniques have shown to improve the achievable dose distribution compared to standard coplanar techniques for multiple treatment sites but finding optimal beam directions is challenging. Dynamic collimator trajectory radiotherapy (colli-DTRT) is a new intensity modulated radiotherapy technique that uses non-coplanar partial arcs and dynamic collimator rotation. PURPOSE: To solve the beam angle optimization (BAO) problem for colli-DTRT and non-coplanar VMAT (NC-VMAT) by determining the table-angle and the gantry-angle ranges of the partial arcs through iterative 4π fluence map optimization (FMO) and beam direction elimination. METHODS: BAO considers all available beam directions sampled on a gantry-table map with the collimator angle aligned to the superior-inferior axis (colli-DTRT) or static (NC-VMAT). First, FMO is performed, and beam directions are scored based on their contributions to the objective function. The map is thresholded to remove the least contributing beam directions, and arc candidates are formed by adjacent beam directions with the same table angle. Next, FMO and arc candidate trimming, based on objective function penalty score, is performed iteratively until a desired total gantry angle range is reached. Direct aperture optimization on the final set of colli-DTRT or NC-VMAT arcs generates deliverable plans. colli-DTRT and NC-VMAT plans were created for seven clinically-motivated cases with targets in the head and neck (two cases), brain, esophagus, lung, breast, and prostate. colli-DTRT and NC-VMAT were compared to coplanar VMAT plans as well as to class-solution non-coplanar VMAT plans for the brain and head and neck cases. Dosimetric validation was performed for one colli-DTRT (head and neck) and one NC-VMAT (breast) plan using film measurements. RESULTS: Target coverage and conformity was similar for all techniques. colli-DTRT and NC-VMAT plans had improved dosimetric performance compared to coplanar VMAT for all treatment sites except prostate where all techniques were equivalent. For the head and neck and brain cases, mean dose reduction-in percentage of the prescription dose-to parallel organs was on average 0.7% (colli-DTRT), 0.8% (NC-VMAT) and 0.4% (class-solution) compared to VMAT. The reduction in D2% for the serial organs was on average 1.7% (colli-DTRT), 2.0% (NC-VMAT) and 0.9% (class-solution). For the esophagus, lung, and breast cases, mean dose reduction to parallel organs was on average 0.2% (colli-DTRT) and 0.3% (NC-VMAT) compared to VMAT. The reduction in D2% for the serial organs was on average 1.3% (colli-DTRT) and 0.9% (NC-VMAT). Estimated delivery times for colli-DTRT and NC-VMAT were below 4 min for a full gantry angle range of 720°, including transitions between arcs, except for the brain case where multiple arcs covered the whole table angle range. These times are in the same order as the class-solution for the head and neck and brain cases. Total optimization times were 25%-107% longer for colli-DTRT, including BAO, compared to VMAT. CONCLUSIONS: We successfully developed dosimetrically motivated BAO for colli-DTRT and NC-VMAT treatment planning. colli-DTRT and NC-VMAT are applicable to multiple treatment sites, including body sites, with beneficial or equivalent dosimetric performances compared to coplanar VMAT and reasonable delivery times.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Masculino , Encéfalo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Rotação , Feminino
9.
Med Phys ; 50(10): 6535-6542, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37338935

RESUMO

BACKGROUND: Dynamic trajectory radiotherapy (DTRT) extends state-of-the-art volumetric modulated arc therapy (VMAT) by dynamic table and collimator rotations during beam-on. The effects of intrafraction motion during DTRT delivery are unknown, especially regarding the possible interplay between patient and machine motion with additional dynamic axes. PURPOSE: To experimentally assess the technical feasibility and quantify the mechanical and dosimetric accuracy of respiratory gating during DTRT delivery. METHODS: A DTRT and VMAT plan are created for a clinically motivated lung cancer case and delivered to a dosimetric motion phantom (MP) placed on the table of a TrueBeam system using Developer Mode. The MP reproduces four different 3D motion traces. Gating is triggered using an external marker block, placed on the MP. Mechanical accuracy and delivery time of the VMAT and DTRT deliveries with and without gating are extracted from the logfiles. Dosimetric performance is assessed by means of gamma evaluation (3% global/2 mm, 10% threshold). RESULTS: The DTRT and VMAT plans are successfully delivered with and without gating for all motion traces. Mechanical accuracy is similar for all experiments with deviations <0.14° (gantry angle), <0.15° (table angle), <0.09° (collimator angle) and <0.08 mm (MLC leaf positions). For DTRT (VMAT), delivery times are 1.6-2.3 (1.6- 2.5) times longer with than without gating for all motion traces except one, where DTRT (VMAT) delivery is 5.0 (3.6) times longer due to a substantial uncorrected baseline drift affecting only DTRT delivery. Gamma passing rates with (without) gating for DTRT/VMAT were ≥96.7%/98.5% (≤88.3%/84.8%). For one VMAT arc without gating it was 99.6%. CONCLUSION: Gating is successfully applied during DTRT delivery on a TrueBeam system for the first time. Mechanical accuracy is similar for VMAT and DTRT deliveries with and without gating. Gating substantially improved dosimetric performance for DTRT and VMAT.


Assuntos
Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Humanos , Estudos de Viabilidade , Radiometria , Pulmão , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
10.
Med Phys ; 50(11): 7104-7117, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37748175

RESUMO

BACKGROUND: To improve organ at risk (OAR) sparing, dynamic trajectory radiotherapy (DTRT) extends VMAT by dynamic table and collimator rotation during beam-on. However, comprehensive investigations regarding the impact of the gantry-table (GT) rotation gradient on the DTRT plan quality have not been conducted. PURPOSE: To investigate the impact of a user-defined GT rotation gradient on plan quality of DTRT plans in terms of dosimetric plan quality, dosimetric robustness, deliverability, and delivery time. METHODS: The dynamic trajectories of DTRT are described by GT and gantry-collimator paths. The GT path is determined by minimizing the overlap of OARs with planning target volume (PTV). This approach is extended to consider a GT rotation gradient by means of a maximum gradient of the path ( G m a x ${G}_{max}$ ) between two adjacent control points ( G = | Δ table angle / Δ gantry angle | $G = | \Delta {{\mathrm{table\ angle}}/\Delta {\mathrm{gantry\ angle}}} |$ ) and maximum absolute change of G ( Δ G m a x ${{\Delta}}{G}_{max}$ ). Four DTRT plans are created with different maximum G&∆G: G m a x ${G}_{max}$ & Δ G m a x ${{\Delta}}{G}_{max}$  = 0.5&0.125 (DTRT-1), 1&0.125 (DTRT-2), 3&0.125 (DTRT-3) and 3&1|(DTRT-4), including 3-4 dynamic trajectories, for three clinically motivated cases in the head and neck and brain region (A, B, and C). A reference VMAT plan for each case is created. For all plans, plan quality is assessed and compared. Dosimetric plan quality is evaluated by target coverage, conformity, and OAR sparing. Dosimetric robustness is evaluated against systematic and random patient-setup uncertainties between ± 3 mm $ \pm 3\ {\mathrm{mm}}$ in the lateral, longitudinal, and vertical directions, and machine uncertainties between ± 4 ∘ $ \pm 4^\circ \ $ in the dynamically rotating machine components (gantry, table, collimator rotation). Delivery time is recorded. Deliverability and delivery accuracy on a TrueBeam are assessed by logfile analysis for all plans and additionally verified by film measurements for one case. All dose calculations are Monte Carlo based. RESULTS: The extension of the DTRT planning process with user-defined G m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ to investigate the impact of the GT rotation gradient on plan quality is successfully demonstrated. With increasing G m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ , slight (case C, D m e a n , p a r o t i d l . ${D}_{mean,\ parotid\ l.}$ : up to|-1|Gy) and substantial (case A, D 0.03 c m 3 , o p t i c n e r v e r . ${D}_{0.03c{m}^3,\ optic\ nerve\ r.}$ : up to -9.3 Gy, case|B, D m e a n , b r a i n $\ {D}_{mean,\ brain}$ : up to -4.7|Gy) improvements in OAR sparing are observed compared to VMAT, while maintaining similar target coverage. All plans are delivered on the TrueBeam. Expected and actual machine position values recorded in the logfiles deviated by <0.2° for gantry, table and collimator rotation. The film measurements agreed by >96% (2%|global/2 mm Gamma passing rate) with the dose calculation. With increasing G m a x & Δ G m a x ${G}_{max}\& {{\Delta}}{G}_{max}$ , delivery time is prolonged by <2 min/trajectory (DTRT-4) compared to VMAT and DTRT-1. The DTRT plans for case A and B and the VMAT plan for case C plan reveal the best dosimetric robustness for the considered uncertainties. CONCLUSION: The impact of the GT rotation gradient on DTRT plan quality is comprehensively investigated for three cases in the head and neck and brain region. Increasing freedom in this gradient improves dosimetric plan quality at the cost of increased delivery time for the investigated cases. No clear dependency of GT rotation gradient on dosimetric robustness is observed.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Rotação , Planejamento da Radioterapia Assistida por Computador , Radiometria
11.
Med Phys ; 49(7): 4780-4793, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35451087

RESUMO

BACKGROUND: Evaluating plan robustness is a key step in radiotherapy. PURPOSE: To develop a flexible Monte Carlo (MC)-based robustness calculation and evaluation tool to assess and quantify dosimetric robustness of intensity-modulated radiotherapy (IMRT) treatment plans by exploring the impact of systematic and random uncertainties resulting from patient setup, patient anatomy changes, and mechanical limitations of machine components. METHODS: The robustness tool consists of two parts: the first part includes automated MC dose calculation of multiple user-defined uncertainty scenarios to populate a robustness space. An uncertainty scenario is defined by a certain combination of uncertainties in patient setup, rigid intrafraction motion and in mechanical steering of the following machine components: angles of gantry, collimator, table-yaw, table-pitch, table-roll, translational positions of jaws, multileaf-collimator (MLC) banks, and single MLC leaves. The Swiss Monte Carlo Plan (SMCP) is integrated in this tool to serve as the backbone for the MC dose calculations incorporating the uncertainties. The calculated dose distributions serve as input for the second part of the tool, handling the quantitative evaluation of the dosimetric impact of the uncertainties. A graphical user interface (GUI) is developed to simultaneously evaluate the uncertainty scenarios according to user-specified conditions based on dose-volume histogram (DVH) parameters, fast and exact gamma analysis, and dose differences. Additionally, a robustness index (RI) is introduced with the aim to simultaneously evaluate and condense dosimetric robustness against multiple uncertainties into one number. The RI is defined as the ratio of scenarios passing the conditions on the dose distributions. Weighting of the scenarios in the robustness space is possible to consider their likelihood of occurrence. The robustness tool is applied on IMRT, a volumetric modulated arc therapy (VMAT), a dynamic trajectory radiotherapy (DTRT), and a dynamic mixed beam radiotherapy (DYMBER) plan for a brain case to evaluate the robustness to uncertainties of gantry-, table-, collimator angle, MLC, and intrafraction motion. Additionally, the robustness of the IMRT, VMAT, and DTRT plan against patient setup uncertainties are compared. The robustness tool is validated by Delta4 measurements for scenarios including all uncertainty types available. RESULTS: The robustness tool performs simultaneous calculation of uncertainty scenarios, and the GUI enables their fast evaluation. For all evaluated plans and uncertainties, the planning target volume (PTV) margin prevented major clinical target volume (CTV) coverage deterioration (maximum observed standard deviation of D 98 % CTV $D98{\% _{{\rm{CTV}}}}$ was 1.3 Gy). OARs close to the PTV experienced larger dosimetric deviations (maximum observed standard deviation of D 2 % chiasma $D2{\% _{{\rm{chiasma}}}}$ was 14.5 Gy). Robustness comparison by RI evaluation against patient setup uncertainties revealed better dosimetric robustness of the VMAT and DTRT plans as compared to the IMRT plan. Delta4 validation measurements agreed with calculations by >96% gamma-passing rate (3% global/2 mm). CONCLUSIONS: The robustness tool was successfully implemented. Calculation and evaluation of uncertainty scenarios with the robustness tool were demonstrated on a brain case. Effects of patient and machine-specific uncertainties and the combination thereof on the dose distribution are evaluated in a user-friendly GUI to quantitatively assess and compare treatment plans and their robustness.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Método de Monte Carlo , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Incerteza
12.
Ann Rheum Dis ; 70(6): 1138-43, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21389044

RESUMO

OBJECTIVES: Interferon α (IFNα) plays a central role in the pathogenesis of systemic lupus erythematosus (SLE) and is considered a target for its treatment. In the current study, the ability of active immunisation with a human (hu) IFNα2b Kinoid (IFN-K) to break B cell tolerance to IFNα and to induce huIFNα-neutralising antibodies in mice immunotolerant to huIFNα2b was assessed. METHODS: IFN-K was manufactured by crosslinking huIFNα2b to keyhole limpet haemocyanin (KLH). Transgenic mice expressing huIFNα2b received by intramuscular injection either saline or polymerised huIFNα2b as controls, or IFN-K, emulsified in ISA51vg adjuvant. RESULTS: All of the huIFNα2b-expressing mice immunised with IFN-K generated neutralising antibodies against huIFNα2b. In addition, these antibodies neutralised all 13 subtypes of huIFNα. They also neutralised IFNα activity in sera collected from 10 different patients with active SLE. However, the antibodies did not bind to huIFNγ or huIFNß. Finally, cellular activation assays showed that immunisation with IFN-K did not induce memory T cells reactive to native huIFNα2b, whereas it did induce memory cells reactive to KLH. CONCLUSION: These results show that active immunisation with IFN-K induces polyclonal antibodies that neutralise all subtypes of huIFNα as well as IFNα in sera from patients with SLE by breaking humoral but not cellular tolerance to IFNα. This suggests that immunisation with IFN-K is a promising new therapeutic strategy for the treatment of SLE.


Assuntos
Interferon-alfa/imunologia , Lúpus Eritematoso Sistêmico/imunologia , Animais , Relação Dose-Resposta Imunológica , Feminino , Hemocianinas/imunologia , Humanos , Tolerância Imunológica/imunologia , Imunoglobulina G/biossíntese , Memória Imunológica/imunologia , Imunoterapia Ativa/métodos , Interferon alfa-2 , Camundongos , Camundongos Transgênicos , Proteínas Recombinantes , Baço/imunologia , Linfócitos T/imunologia
13.
Cancers (Basel) ; 12(4)2020 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-32244473

RESUMO

In the adult, many embryologic processes can be co-opted by during cancer progression. The mechanisms of divisions, migration, and the ability to escape immunity recognition linked to specific embryo antigens are also expressed by malignant cells. In particular, cells derived from neural crests (NC) contribute to the development of multiple cell types including melanocytes, craniofacial cartilage, glia, neurons, peripheral and enteric nervous systems, and the adrenal medulla. This plastic performance is due to an accurate program of gene expression orchestrated with cellular/extracellular signals finalized to regulate long-distance migration, proliferation, differentiation, apoptosis, and survival. During neurulation, prior to initiating their migration, NC cells must undergo an epithelial-mesenchymal transition (EMT) in which they alter their actin cytoskeleton, lose their cell-cell junctions, apicobasal polarity, and acquire a motile phenotype. Similarly, during the development of the tumors derived from neural crests, comprising a heterogeneous group of neoplasms (Neural crest-derived tumors (NCDTs)), a group of genes responsible for the EMT pathway is activated. Here, retracing the molecular pathways performed by pluripotent cells at the boundary between neural and non-neural ectoderm in relation to the natural history of NCDT, points of contact or interposition are highlighted to better explain the intricate interplay between cancer cells and the innate and adaptive immune response.

14.
Prog Neurobiol ; 173: 41-53, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29886147

RESUMO

Neural stem cells persist in the adult central nervous system as a continuing source of astrocytes, oligodendrocytes and neurons. Various signalling pathways and transcription factors actively maintain this population by regulating cell cycle entry and exit. Similarly, the circadian clock is interconnected with the cell cycle and actively maintains stem cell populations in various tissues. Here, we discuss emerging evidence for an important role of the circadian clock in neural stem cell maintenance. We propose that the NAD+-dependent deacetylase SIRT1 exerts control over the circadian clock in adult neural stem cell function to limit exhaustion of their population. Conversely, disruption of the circadian clock may compromise neural stem cell quiescence resulting in a premature decline of the neural stem cell population. As such, energy metabolism and the circadian clock converge in adult neural stem cell maintenance.


Assuntos
Células-Tronco Adultas/fisiologia , Relógios Circadianos/fisiologia , Células-Tronco Neurais/fisiologia , Animais , Proliferação de Células/fisiologia , Humanos
15.
Allergy ; 63(3): 310-26, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18269676

RESUMO

Allergen extracts have been used for diagnosis and treatment of allergy for around 100 years. During the second half of 20th century, the notion increasingly gained foothold that accurate standardization of such extracts is of great importance for improvement of their quality. As a consequence, manufacturers have implemented extensive protocols for standardization and quality control. These protocols have overall IgE-binding potencies as their focus. Unfortunately, each company is using their own in-house reference materials and their own unique units to express potencies. This does not facilitate comparison of different products. During the last decades, most major allergens of relevant allergen sources have been identified and it has been established that effective immunotherapy requires certain minimum quantities of these allergens to be present in the administered maintenance dose. Therefore, the idea developed to introduce major allergens measurements into standardization protocols. Such protocols based on mass units of major allergen, quantify the active ingredients of the treatment and will at the same time allow comparison of competitor products. In 2001, an EU funded project, the CREATE project, was started to support introduction of major allergen based standardization. The aim of the project was to evaluate the use of recombinant allergens as reference materials and of ELISA assays for major allergen measurements. This paper gives an overview of the achievements of the CREATE project.


Assuntos
Alérgenos/classificação , Guias como Assunto , Hipersensibilidade/diagnóstico , Proteínas Recombinantes , Estudos de Validação como Assunto , Cromatografia Líquida de Alta Pressão/normas , Dessensibilização Imunológica/normas , Ensaio de Imunoadsorção Enzimática/normas , Europa (Continente) , Feminino , Humanos , Masculino , Espectrometria de Massas/normas , Proteínas Recombinantes/normas , Padrões de Referência , Valores de Referência , Sensibilidade e Especificidade , Análise Espectral/normas , Organização Mundial da Saúde
16.
Phys Med ; 45 Suppl 1: S3, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29413853

RESUMO

Over the last couple of years the implementation of Monte Carlo (MC) methods of grating based imaging techniques is of increasing interest. Several different approaches were taken to include coherent effects into MC in order to simulate the radiation transport of the image forming procedure. These include full MC using FLUKA [1], which however are only considering monochromatic sources. Alternatively, ray-tracing based MC [2] allow fast simulations with the limitation to provide only qualitative results, i.e. this technique is not suitable for dose calculation in the imaged object. Finally, hybrid models [3] were used allowing quantitative results in reasonable computation time, however only two-dimensional implementations are available. Thus, this work aims to develop a full MC framework for X-ray grating interferometry imaging systems using polychromatic sources suitable for large-scale samples. For this purpose the EGSnrc C++ MC code system is extended to take Snell's law, the optical path length and Huygens principle into account. Thereby the EGSnrc library was modified, e.g. the complex index of refraction has to be assigned to each region depending on the material. The framework is setup to be user-friendly and robust with respect to future updates of the EGSnrc package. These implementations have to be tested using dedicated academic situations. Next steps include the validation by comparisons of measurements for different setups with the corresponding MC simulations. Furthermore, the newly developed implementation will be compared with other simulation approaches. This framework will then serve as bases for dose calculation on CT data and has further potential to investigate the image formation process in grating based imaging systems.

18.
Med Phys ; 44(4): 1212-1223, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28134989

RESUMO

PURPOSE: To develop a robust and efficient process that detects relevant dose errors (dose errors of ≥5%) in external beam radiation therapy and directly indicates the origin of the error. The process is illustrated in the context of electronic portal imaging device (EPID)-based angle-resolved volumetric-modulated arc therapy (VMAT) quality assurance (QA), particularly as would be implemented in a real-time monitoring program. METHODS: A Swiss cheese error detection (SCED) method was created as a paradigm for a cine EPID-based during-treatment QA. For VMAT, the method compares a treatment plan-based reference set of EPID images with images acquired over each 2° gantry angle interval. The process utilizes a sequence of independent consecutively executed error detection tests: an aperture check that verifies in-field radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment check to examine if rotation, scaling, and translation are within tolerances; pixel intensity check containing the standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each check were determined. To test the SCED method, 12 different types of errors were selected to modify the original plan. A series of angle-resolved predicted EPID images were artificially generated for each test case, resulting in a sequence of precalculated frames for each modified treatment plan. The SCED method was applied multiple times for each test case to assess the ability to detect introduced plan variations. To compare the performance of the SCED process with that of a standard gamma analysis, both error detection methods were applied to the generated test cases with realistic noise variations. RESULTS: Averaged over ten test runs, 95.1% of all plan variations that resulted in relevant patient dose errors were detected within 2° and 100% within 14° (<4% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 89.1% were detected by the SCED method within 2°. Based on the type of check that detected the error, determination of error sources was achieved. With noise ranging from no random noise to four times the established noise value, the averaged relevant dose error detection rate of the SCED method was between 94.0% and 95.8% and that of gamma between 82.8% and 89.8%. CONCLUSIONS: An EPID-frame-based error detection process for VMAT deliveries was successfully designed and tested via simulations. The SCED method was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of relevant dose errors. Compared to a typical (3%, 3 mm) gamma analysis, the SCED method produced a higher detection rate for all introduced dose errors, identified errors in an earlier stage, displayed a higher robustness to noise variations, and indicated the error source.


Assuntos
Equipamentos e Provisões Elétricas , Erros Médicos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia de Intensidade Modulada/instrumentação , Humanos , Erros Médicos/prevenção & controle , Imagens de Fantasmas , Dosagem Radioterapêutica , Fatores de Tempo
19.
Cardiovasc Res ; 113(10): 1230-1242, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28898997

RESUMO

AIMS: Angiotensin II-infused ApoE-/- mice are a popular mouse model for preclinical aneurysm research. Here, we provide insight in the often-reported but seldom-explained variability in shape of dissecting aneurysms in these mice. METHODS AND RESULTS: N = 45 excised aortas were scanned ex vivo with phase-contrast X-ray tomographic microscopy. Micro-ruptures were detected near the ostium of celiac and mesenteric arteries in 8/11 mice that were sacrificed after 3 days of angiotensin II-infusion. At later time points (after 10, 18, and 28 days) the variability in shape of thoraco-abdominal lesions (occurring in 31/34 mice) was classified into 7 different categories based on the presence or absence of a medial tear (31/31), an intramural hematoma (23/31) or a false channel (11/23). Medial tears were detected both in the thoracic and the abdominal aorta and were most prevalent at the left and ventral aspects of celiac and mesenteric arteries. The axial length of the hematoma strongly correlated to the total number of ruptured branch ostia (r2 = 0.78) and in 22/23 mice with a hematoma the ostium of the left suprarenal artery had ruptured. Supraceliac diameters at baseline were significantly lower for mice that did not develop an intramural hematoma, and the formation of a false channel within that intramural hematoma depended on the location, rather than the length, of the medial tear. CONCLUSION: Based on our observations we propose an elaborate hypothesis that explains how aortic side branches (i) affect the initiation and propagation of medial tears and the subsequent adventitial dissection and (ii) affect the variability in shape of dissecting aneurysms. This hypothesis was partially validated through the live visualization of a dissecting aneurysm that formed during micro-CT imaging, and led us to the conclusion that angiotensin II-infused mice are more clinically relevant for the study of aortic dissections than for the study of abdominal aortic aneurysms.


Assuntos
Angiotensina II , Aorta Abdominal/patologia , Aorta Torácica/patologia , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Torácica/patologia , Dissecção Aórtica/patologia , Dissecção Aórtica/induzido quimicamente , Dissecção Aórtica/genética , Dissecção Aórtica/metabolismo , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/metabolismo , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/metabolismo , Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/genética , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Torácica/induzido quimicamente , Aneurisma da Aorta Torácica/genética , Aneurisma da Aorta Torácica/metabolismo , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Modelos Animais de Doenças , Progressão da Doença , Hematoma/patologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout para ApoE , Fatores de Tempo , Ultrassonografia Doppler de Pulso , Remodelação Vascular , Microtomografia por Raio-X
20.
Biochim Biophys Acta ; 1731(2): 133-8, 2005 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-16289364

RESUMO

Forkhead transcription factors comprise a large family of key regulators of embryonic development. Here, we describe the cloning and analysis of the murine Foxi2 gene, coding for a putative 311 amino acid protein resembling Foxi subfamily members in mice and other species. Expression analysis during the final stages of embryonic development revealed that Foxi2 expression is mainly confined to subsets of cells in epithelial structures and particular ducts, in addition to the developing forebrain and neural retina. Since FoxI factors are thought to be implicated in the regulation of cell fate, the highly restricted expression pattern of Foxi2 suggestive of a possible role in controlling cellular identity.


Assuntos
Clonagem Molecular , Camundongos/genética , Sequência de Aminoácidos , Animais , Sequência de Bases , Camundongos/embriologia , Camundongos Endogâmicos C57BL , Dados de Sequência Molecular , Prosencéfalo/embriologia , Prosencéfalo/enzimologia , Retina/embriologia , Retina/metabolismo , Alinhamento de Sequência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA