Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J Suppl ; 25(Suppl C): C189-C199, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125282

RESUMO

Treatments for structural heart diseases (SHD) have been considerably evolved by the widespread of transcatheter approach in the last decades. The progression of transcatheter treatments for SHD was feasible due to the improvement of devices and the advances in imaging techniques. In this setting, the cardiovascular imaging is pivotal not only for the diagnosis but even for the treatment of SHD. With the aim of fulfilling these tasks, a multimodality imaging approach with new imaging tools for pre-procedural planning, intra-procedural guidance, and follow-up of SHD was developed. This review will describe the current state-of-the-art imaging techniques for the most common percutaneous interventions as well as the new imaging tools. The imaging approaches will be addressed describing the use in pre-procedural planning, intra-procedural guidance, and follow-up.

2.
Int J Mol Sci ; 24(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37569352

RESUMO

A great deal of evidence has revealed an important link between gut microbiota and the heart. In particular, the gut microbiota plays a key role in the onset of cardiovascular (CV) disease, including heart failure (HF). In HF, splanchnic hypoperfusion causes intestinal ischemia resulting in the translocation of bacteria and their metabolites into the blood circulation. Among these metabolites, the most important is Trimethylamine N-Oxide (TMAO), which is responsible, through various mechanisms, for pathological processes in different organs and tissues. In this review, we summarise the complex interaction between gut microbiota and CV disease, particularly with respect to HF, and the possible strategies for influencing its composition and function. Finally, we highlight the potential role of TMAO as a novel prognostic marker and a new therapeutic target for HF.


Assuntos
Doenças Cardiovasculares , Microbioma Gastrointestinal , Insuficiência Cardíaca , Humanos , Metilaminas/metabolismo , Insuficiência Cardíaca/metabolismo
3.
Heart Fail Rev ; 26(2): 337-345, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32901315

RESUMO

Initially developed as glucose-lowering drugs, sodium-glucose co-transporter type 2 inhibitors (SGLT2i) have demonstrated to be effective agents for the risk reduction of cardiovascular (CV) events in patients with type 2 diabetes mellitus (T2DM). Subsequently, data has emerged showing a significant CV benefit in patients treated with SGLT2i regardless of diabetes status. Renal protection has been initially evaluated in CV randomized trials only as secondary endpoints; nonetheless, the positive results gained have rapidly led to the evaluation of nephroprotection as primary outcome in the CREDENCE trial. Different renal and vascular mechanisms can account for the CV and renal benefits enlightened in recent literature. As clinical guidelines rapidly evolve and the role of SGLT2i appears to become pivotal for CV, T2DM, and kidney disease management, in this review, we analyze the renal effects of SGLT2, the benefits derived from its inhibition, and how this may result in the multiple CV and renal benefits evidenced in recent clinical trials.


Assuntos
Doenças Cardiovasculares , Sistema Cardiovascular , Diabetes Mellitus Tipo 2 , Inibidores do Transportador 2 de Sódio-Glicose , Doenças Cardiovasculares/prevenção & controle , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Humanos , Rim , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico
4.
Europace ; 23(10): 1603-1611, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34297833

RESUMO

AIMS: To assess the clinical relevance of a history of atrial fibrillation (AF) in hospitalized patients with coronavirus disease 2019 (COVID-19). METHODS AND RESULTS: We enrolled 696 consecutive patients (mean age 67.4 ± 13.2 years, 69.7% males) admitted for COVID-19 in 13 Italian cardiology centres between 1 March and 9 April 2020. One hundred and six patients (15%) had a history of AF and the median hospitalization length was 14 days (interquartile range 9-24). Patients with a history of AF were older and with a higher burden of cardiovascular risk factors. Compared to patients without AF, they showed a higher rate of in-hospital death (38.7% vs. 20.8%; P < 0.001). History of AF was associated with an increased risk of death after adjustment for clinical confounders related to COVID-19 severity and cardiovascular comorbidities, including history of heart failure (HF) and increased plasma troponin [adjusted hazard ratio (HR): 1.73; 95% confidence interval (CI) 1.06-2.84; P = 0.029]. Patients with a history of AF also had more in-hospital clinical events including new-onset AF (36.8% vs. 7.9%; P < 0.001), acute HF (25.3% vs. 6.3%; P < 0.001), and multiorgan failure (13.9% vs. 5.8%; P = 0.010). The association between AF and worse outcome was not modified by previous or concomitant use of anticoagulants or steroid therapy (P for interaction >0.05 for both) and was not related to stroke or bleeding events. CONCLUSION: Among hospitalized patients with COVID-19, a history of AF contributes to worse clinical course with a higher mortality and in-hospital events including new-onset AF, acute HF, and multiorgan failure. The mortality risk remains significant after adjustment for variables associated with COVID-19 severity and comorbidities.


Assuntos
Fibrilação Atrial , COVID-19 , Insuficiência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Mortalidade Hospitalar , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , SARS-CoV-2
5.
Europace ; 23(7): 1072-1083, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33792661

RESUMO

AIMS: The aim of this registry was to evaluate the additional prognostic value of a composite cardiac magnetic resonance (CMR)-based risk score over standard-of-care (SOC) evaluation in a large cohort of consecutive unselected non-ischaemic cardiomyopathy (NICM) patients. METHODS AND RESULTS: In the DERIVATE registry (www.clinicaltrials.gov/registration: RCT#NCT03352648), 1000 (derivation cohort) and 508 (validation cohort) NICM patients with chronic heart failure (HF) and left ventricular ejection fraction <50% were included. All-cause mortality and major adverse arrhythmic cardiac events (MAACE) were the primary and secondary endpoints, respectively. During a median follow-up of 959 days, all-cause mortality and MAACE occurred in 72 (7%) and 93 (9%) patients, respectively. Age and >3 segments with midwall fibrosis on late gadolinium enhancement (LGE) were the only independent predictors of all-cause mortality (HR: 1.036, 95% CI: 1.0117-1.056, P < 0.001 and HR: 2.077, 95% CI: 1.211-3.562, P = 0.008, respectively). For MAACE, the independent predictors were male gender, left ventricular end-diastolic volume index by CMR (CMR-LVEDVi), and >3 segments with midwall fibrosis on LGE (HR: 2.131, 95% CI: 1.231-3.690, P = 0.007; HR: 3.161, 95% CI: 1.750-5.709, P < 0.001; and HR: 1.693, 95% CI: 1.084-2.644, P = 0.021, respectively). A composite clinical and CMR-based risk score provided a net reclassification improvement of 63.7% (P < 0.001) for MAACE occurrence when added to the model based on SOC evaluation. These findings were confirmed in the validation cohort. CONCLUSION: In a large multicentre, multivendor cohort registry reflecting daily clinical practice in NICM work-up, a composite clinical and CMR-based risk score provides incremental prognostic value beyond SOC evaluation, which may have impact on the indication of implantable cardioverter-defibrillator implantation.


Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Meios de Contraste , Feminino , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Volume Sistólico , Função Ventricular Esquerda
6.
Blood Press ; 29(6): 375-381, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32608283

RESUMO

PURPOSE: Cuffless blood pressure (CL-BP) measurements are believed to be a potentially alternative to cuff-occlusion-based (C-BP) measurement. A new cuffless device was developed for ambulatory BP monitoring. We assessed the accuracy of a new CL-BP device compared to a standard oscillatory C-BP device over the 24 h. MATERIALS AND METHODS: Eighty-four consecutive patients were included in the study. BP was measured simultaneously by the CL-BP device and by a C-BP device over the 24 h. Calculations included 24 h mean systolic (S) BP, the mean diastolic (D) BP and the heart rate (HR). Correlations between the CL-BP and C-BP measurements were sought using Pearson's correlation coefficients and Bland-Altman plots. RESULTS: Using the C-BP device, the 24 h SBP value for the cohort was 125.4 ± 10.9 mmHg (mean ± SD); the corresponding DBP value being 75 ± 8.3 mmHg. Mean SBP/DBP were higher with the CL-BP device, i.e. 131.1 ± 15.9/80.2 ± 9.7 mmHg . The correlation coefficients between the two sets of values were significant (SBP: r = 0.58, DBP: r = 0.65). Better correlations for SBP and DBP were found 1) in patients with BMI > 25 (SBP: r = 0.65, DBP: r = 0.70) compared to those with BMI <25 and 2) in males compared to females (SBP: r = 0.71, DBP: r = 0.77). CONCLUSIONS: In our patients a CL-BP device estimated 24 h mean SBP and DBP differently from the classical oscillometric device, with a moderate correlation. CL-BP measurements were most accurate on male and overweight subjects.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Pressão Sanguínea , Idoso , Diástole , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Sístole
7.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522488

RESUMO

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Ecocardiografia Tridimensional/métodos , Feminino , Masculino , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Pessoa de Meia-Idade , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Doppler em Cores/métodos , Reprodutibilidade dos Testes , Valva Mitral/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
8.
JACC Case Rep ; 29(4): 102200, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379644

RESUMO

Valve-in-ring procedures represent a feasible solution for high-risk patients with surgical repair failure. The risk of left ventricular outflow tract obstruction increases the challenge, and transcatheter approaches to prevent it are technically demanding and often do not resolve it. We demonstrate the feasibility and safety of a transseptal balloon-assisted translocation of the anterior mitral leaflet for valve-in-ring implantation.

9.
JACC Case Rep ; 29(12): 102372, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38774636

RESUMO

The diagnostic approach toward the management of cardiac implantable electronic device-related tricuspid regurgitation is challenging and undefined. Functional cardiac computed tomography angiography provides a complementary role to echocardiography in the evaluation of lead-leaflet interaction which can help the clinical decision-making process, as presented in this case series.

10.
Can J Cardiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38492735

RESUMO

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

11.
Eur Heart J Cardiovasc Imaging ; 24(5): 678-686, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-36056887

RESUMO

AIMS: In patients with obstructive hypertrophic cardiomyopathy (HCM) and mild septal thickness undergoing myectomy, resecting fibrotic anterior mitral leaflet (AML) secondary chordae moves the mitral valve (MV) away from the outflow tract and ejection flow, reducing the need for a deep septal excision. Aim of the present study was to assess whether chordal resection has similarly favourable effects in patients with important hypertrophy, who represent the majority of patients with obstructive HCM. METHODS AND RESULTS: The MV position in the ventricular cavity, assessed from echocardiography as AML-annulus ratio, was compared before and after chordal resection in 150 consecutive HCM patients with important (≥20 mm) and 62 with mild (≤19 mm) septal thickness undergoing myectomy. Preoperatively, MV position was displaced towards the septum to a similar extent in both groups. Postoperatively, AML-annulus ratio increased of an equal degree in both groups, from 0.43 ± 0.05 to 0.55 ± 0.06 (P < 0.001) a 28% increase, and from 0.43 ± 0.06 to 0.55 ± 0.06 (P < 0.001) a 26% increase, respectively, indicating a similar MV shift away from the outflow tract. When AML-annulus ratio was compared in the study cohort and 124 normal subjects, MV position was within normal range in <4% of patients preoperatively and normalized in >50% postoperatively. CONCLUSIONS: In obstructive HCM, displacement of the MV apparatus into the outflow tract interferes with the ejection flow. Resection of fibrotic secondary chordae moves the MV apparatus away from the outflow tract and enlarges the outflow area independently of septal thickness, facilitating septal myectomy by reducing the need for a deep muscular excision.


Assuntos
Cardiomiopatia Hipertrófica , Leucemia Mieloide Aguda , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia , Hipertrofia , Fibrose , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia
12.
J Arrhythm ; 39(3): 395-404, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37324751

RESUMO

Background: The role of left atrial appendage occlusion (LAAO) for atrial fibrillation patients that during oral anticoagulant therapy (OAC) suffer from ischemic events or present LAA sludge, and the best postinterventional anticoagulant regimen, need to be defined. We present our experience with a hybrid approach of LAAO+ lifelong OAC therapy in this cohort of patients. Methods: Out of 425 patients treated with LAAO, 102 underwent LAAO because, despite OAC, suffered from ischemic events or presented with LAA sludge. Patients without high bleeding risk were discharged with the aim of maintaining lifelong OAC. This cohort was then matched to a population who underwent LAAO in primary ischemic events prevention. The primary endpoint was the composite of all-cause death and major adverse cardiovascular events consisting of ischemic stroke, systemic embolism (SE), and major bleeding. Results: Procedural success was 98%, and 70% of patients were discharged with anticoagulant therapy. After a median follow-up of 47.2 months, the primary endpoint occurred in 27 patients (26%). At multivariate analyses, coronary artery disease (OR 5.1, CI 1.89-14.27, p = .003) and OAC at discharge (OR 0.29, CI 0.11-0.80, p = .017) were associated with the primary endpoint. After propensity score matching, no significant difference was found in the survival free from the primary endpoint according to the indication for LAAO (p = .19). Conclusions: In this high-ischemic risk cohort, LAAO + OAC seem a long-term safe and effective therapeutical approach, with no difference in the survival free from the primary endpoint according to the indication for LAAO in a matched cohort.

13.
J Am Soc Echocardiogr ; 36(10): 1083-1091, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37307939

RESUMO

BACKGROUND: Contrast-enhanced computed tomography is the reference-standard imaging technique to assess left atrial appendage (LAA) morphology. The aim of this study was to evaluate the accuracy and reliability of two-dimensional and new three-dimensional (3D) transesophageal echocardiographic rendering modalities in assessing LAA morphology. METHODS: Seventy consecutive patients who underwent both computed tomography and transesophageal echocardiography (TEE) were retrospectively enrolled. The traditional LAA morphology classification system (LAAcs; chicken wing, cauliflower, cactus, and windsock) and a new simplified LAAcs based on the LAA bend angle were used for the analysis. LAA morphology was independently assessed by two trained readers using three different modalities: two-dimensional TEE, 3D TEE with multiplanar reconstruction, and a new 3D transesophageal echocardiographic rendering modality with improved transparency (Glass). The new LAAcs and traditional LAAcs were compared in terms of intra- and interrater reliability. RESULTS: With the new LAAcs, two-dimensional TEE was fairly accurate in identifying LAA morphology (κ = 0.43, P < .05), with moderate interrater (κ = 0.50, P < .05) and substantial intrarater (κ = 0.65, P < .005) agreement. Three-dimensional TEE showed higher accuracy and reliability: 3D TEE with multiplanar reconstruction had almost perfect accuracy (κ = 0.85, P < .001) and substantial (κ = 0.79, P < .001) interrater reliability, while 3D TEE with Glass had substantial accuracy (κ = 0.70, P < .001) and almost perfect (κ = 0.84, P < .001) interrater reliability. Intrarater agreement was almost perfect for both 3D transesophageal echocardiographic modalities (κ = 0.85, P < .001). Accuracy was considerably lower when the traditional LAAcs was used, with 3D TEE with Glass being the most reliable technique (κ = 0.75, P < .05). The new LAAcs showed higher inter- and intrarater reliability compared with the traditional LAAcs (interrater, κ = 0.85 vs κ = 0.49; intrarater, κ = 0.94 vs κ = 0.68; P < .05). CONCLUSIONS: Three-dimensional TEE is an accurate, reliable, and feasible alternative to computed tomography in assessing LAA morphology with the new LAAcs. The new LAAcs shows higher reliability rates than the traditional one.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Ecocardiografia Transesofagiana/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
14.
Front Cardiovasc Med ; 10: 1172005, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37383696

RESUMO

Background: Percutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support. Methods: Intraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year. Results: Of the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p < 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan-Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring. Conclusions: Our results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers.

15.
J Cardiovasc Dev Dis ; 10(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37233154

RESUMO

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is emerging as an effective treatment for patients with symptomatically failing bioprosthetic valves and a high prohibitive surgical risk; a longer life expectancy has led to a higher demand for these valve reinterventions due to the increased possibilities of outliving the bioprosthetic valve's durability. Coronary obstruction is the most feared complication of valve-in-valve (ViV) TAVR; it is a rare but life-threatening complication and occurs most frequently at the left coronary artery ostium. Accurate pre-procedural planning, mainly based on cardiac computed tomography, is crucial to determining the feasibility of a ViV TAVR and to assessing the anticipated risk of a coronary obstruction and the eventual need for coronary protection measures. Intraprocedurally, the aortic root and a selective coronary angiography are useful for evaluating the anatomic relationship between the aortic valve and coronary ostia; transesophageal echocardiographic real-time monitoring of the coronary flow with a color Doppler and pulsed-wave Doppler is a valuable tool that allows for a determination of real-time coronary patency and the detection of asymptomatic coronary obstructions. Because of the risk of developing a delayed coronary obstruction, the close postprocedural monitoring of patients at a high risk of developing coronary obstructions is advisable. CT simulations of ViV TAVR, 3D printing models, and fusion imaging represent the future directions that may help provide a personalized lifetime strategy and tailored approach for each patient, potentially minimizing complications and improving outcomes.

16.
J Clin Med ; 12(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37240489

RESUMO

Severe tricuspid valve (TV) regurgitation (TR) has been associated with adverse long-term outcomes in several natural history studies, but isolated TV surgery presents high mortality and morbidity rates. Transcatheter tricuspid valve interventions (TTVI) therefore represent a promising field and may currently be considered in patients with severe secondary TR that have a prohibitive surgical risk. Tricuspid transcatheter edge-to-edge repair (T-TEER) represents one of the most frequently used TTVI options. Accurate imaging of the tricuspid valve (TV) apparatus is crucial for T-TEER preprocedural planning, in order to select the right candidates, and is also fundamental for intraprocedural guidance and post-procedural follow-up. Although transesophageal echocardiography represents the main imaging modality, we describe the utility and additional value of other imaging modalities such as cardiac CT and MRI, intracardiac echocardiography, fluoroscopy, and fusion imaging to assist T-TEER. Developments in the field of 3D printing, computational models, and artificial intelligence hold great promise in improving the assessment and management of patients with valvular heart disease.

17.
Eur Heart J Cardiovasc Imaging ; 24(11): 1509-1517, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37194460

RESUMO

AIMS: To evaluate the prognostic impact of pre-procedural right ventricular longitudinal strain (RVLS) in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge repair (TEER) in comparison with conventional echocardiographic parameters of RV function. METHODS AND RESULTS: This is a retrospective study including 142 patients with SMR undergoing TEER at two Italian centres. At 1-year follow-up 45 patients reached the composite endpoint of all-cause death or heart failure hospitalization. The best cut-off value of RV free-wall longitudinal strain (RVFWLS) to predict outcome was -18% [sensitivity 72%, specificity of 71%, area under curve (AUC) 0.78, P < 0.001], whereas the best cut-off value of RV global longitudinal strain (RVGLS) was -15% (sensitivity 56%, specificity 76%, AUC 0.69, P < 0.001). Prognostic performance was suboptimal for tricuspid annular plane systolic excursion, Doppler tissue imaging-derived tricuspid lateral annular systolic velocity and fractional area change (FAC). Cumulative survival free from events was lower in patients with RVFWLS ≥ -18% vs. RVFWLS < -18% (44.0% vs. 85.4%; < 0.001) as well as in patients with RVGLS ≥ -15% vs. RVGLS < -15% (54.9% vs. 81.7%; P < 0.001). At multivariable analysis FAC, RVGLS and RVFWLS were independent predictors of events. The identified cut-off of RVFWLS and RVGLS both resulted independently associated with outcomes. CONCLUSION: RVLS is a useful and reliable tool to identify patients with SMR undergoing TEER at high risk of mortality and HF hospitalization, on top of other clinical and echocardiographic parameters, with RVFWLS offering the best prognostic performance.


Assuntos
Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Prognóstico , Estudos Retrospectivos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valor Preditivo dos Testes
18.
Int J Cardiol ; 387: 131135, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37364718

RESUMO

BACKGROUND: To evaluate the long-term clinical outcome of a cohort of patients suffering from moderate tricuspid regurgitation (TR), regardless of its etiology. METHODS: Clinical and echocardiographic follow-up were assessed in 250 patients diagnosed with moderate TR between January 2016 and July 2020. TR progression at follow-up was defined as TR grade increase to at least severe. The primary endpoint was all-cause death; secondary endpoints were cardiovascular (CV) death and the composite of heart failure (HF) hospitalization plus tricuspid valve (TV) intervention. RESULTS: After a median follow-up of 3.6 years, TR progression occurred in 84 patients (34%). At multivariate analyses, atrial fibrillation (AF, OR 1.81, CI 1.01-3.29, p = 0.045) and right ventricular end-diastolic diameter (RVEDD, OR 2.19, CI 1.26-3.78, p = 0.005) were independent predictors of TR progression. The primary endpoint occurred in 59 patients (24%) and was significantly more frequent in the group with TR progression (p = 0.009). At multivariate analyses, chronic kideney disease (OR 2.80, CI 1.30-6.03, p = 0.009), left ventricular ejection fraction (OR 0.97, CI 0.94-0.99, p = 0.041) and TR progression (OR 2.32, CI 1.31-4.12, p = 0.004) were independent predictors of the primary outcome. Moreover, both the secondary endpoints of CV death and HF hospitalization plus TV intervention were more frequent in the TR progression group (p = 0.001 and p < 0.001, respectively). CONCLUSIONS: Moderate TR progresses in a significant proportion of patients over a long-term follow-up, leading to a worse prognosis. TR progression is an independent determinant of hard clinical events and AF and RVEDD are associated with TR progression.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Doença Crônica , Progressão da Doença
19.
Eur Heart J Cardiovasc Imaging ; 24(7): 887-896, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-36916015

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is the treatment of choice for high-risk patients with severe aortic stenosis (AS). A portion of TAVI recipients has no long-term clinical benefit, and myocardial fibrosis may contribute to unfavourable outcomes. We aimed to assess the prognostic value of an interstitial fibrosis marker, extracellular volume fraction (ECV), measured at planning computed tomography (CT) before TAVI. METHODS AND RESULTS: From October 2020 to July 2021, 159 consecutive patients undergoing TAVI planning CT were prospectively enroled. ECV was calculated as the ratio of myocardium and blood pool differential attenuations before and 5 min after contrast administration, pondered for haematocrit. A composite endpoint including heart failure hospitalization (HFH) and death was collected by telehealth or in-person follow-up visits in the 113 patients constituting the final study population. Cox proportional hazards model was used to assess association between ECV and the composite endpoint.Median follow-up was 13 (11-15) months. The composite endpoint occurred in 23/113 (20%) patients. These patients had lower aortic valve mean pressure gradient [39 (29-48) vs. 46 (40-54) mmHg, P = 0.002] and left ventricular and right ventricular ejection fraction [51 (37-69) vs. 66 (54-74)%, P = 0.014; 45 (31-53) vs. 49 (44-55)%, P = 0.010] and higher ECV [31.5 (26.9-34.3) vs. 27.8 (25.3-30.2)%, P = 0.006]. At multivariable Cox analysis, ECV higher than 31.3% was associated to increased risk of death or HFH at follow-up (hazard ratio = 5.92, 95% confidence interval 2.37-14.75, P < 0.001). CONCLUSION: In this prospective observational cohort study, ECV measured at TAVI planning CT predicts the composite endpoint (HFH or death) in high-risk severe AS patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Função Ventricular Direita , Prognóstico , Valva Aórtica/cirurgia , Fibrose , Tomografia Computadorizada por Raios X , Tomografia , Função Ventricular Esquerda
20.
Minerva Med ; 114(2): 137-147, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34180639

RESUMO

BACKGROUND: Limited real-world data are available regarding the comparison about safety and efficacy of DOACs prescription in very elderly patients (≥85 years) with non-valvular atrial fibrillation (NVAF). Concern about the risk of bleeding with anticoagulation in very older patients still represents an important challenge for clinicians. The aim of this study was to evaluate the different prevalence of major bleeding and thromboembolic events between very elderly NVAF patients (≥85 years) compared to those non very elderly (<85 years). METHODS: Single center multidisciplinary registry including NVAF patients treated with DOACs. Primary safety endpoint was 2-year rate of major bleeding. Primary efficacy endpoint was 2-year rate of thromboembolic events. Event-free survival curves among groups were compared using Cox-Mantel Test. RESULTS: 908 NVAF consecutive patients were included, of these, 805 patients were <85 years (89%) and 103 patients were very elderly patients with ≥85 years (11%). Compared to patients <85 years, those very elderly have higher CHA2DS2-VASc Score (P=0.001), higher rate of hypertension (P=0.001), diabetes mellitus (P=0.030), previous bleeding events (P<0.001), previous stroke/TIA/SE (P≤0.001), heart failure (P≤0.001), and lower creatinine clearance (P<0.001). In terms of safety endpoints (overall ISTH-major bleeding) no significative difference between two groups (P=0.952) were observed up to 2-year follow-up. Systemic thromboembolic event (primary efficacy endpoint) was significantly higher in patients with ≥85 years (P=0.027). The incidence of all-cause death was significantly higher in very elderly patients (P<0.001). CONCLUSIONS: This single center registry, showed that the use of DOACs in very elderly NVAF was safe and is a therapeutic option to be pursued for stroke prevention especially for those who are at high risk of ischemic events.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Anticoagulantes/uso terapêutico , Acidente Vascular Cerebral/etiologia , Hemorragia/induzido quimicamente , Tromboembolia/prevenção & controle , Administração Oral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA