Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Nature ; 622(7983): 471-475, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37758953

RESUMO

Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices1. The search for more stable and convenient reference oscillators is continuing2-6. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations7-9. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10). The scientific potential of 45Sc was realized long ago, but applications require 45Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources11 that have become available only recently. Here we report on resonant X-ray excitation of the 45Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as [Formula: see text] with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.

2.
J Synchrotron Radiat ; 28(Pt 1): 120-124, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399560

RESUMO

This work presents the improvements in the design and testing of polarimeters based on channel-cut crystals for nuclear resonant scattering experiments at the 14.4 keV resonance of 57Fe. By using four asymmetric reflections at asymmetry angles of α1 = -28°, α2 = 28°, α3 = -28° and α4 = 28°, the degree of polarization purity could be improved to 2.2 × 10-9. For users, an advanced polarimeter without beam offset is now available at beamline P01 of the storage ring PETRA III.

3.
J Synchrotron Radiat ; 22(5): 1151-4, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26289265

RESUMO

The spectrum of the undulator radiation of beamline P01 at Petra III has been measured after passing a multiple reflection channel-cut polarimeter. Odd and even harmonics up to the 15th order, as well as Compton peaks which were produced by the high harmonics in the spectrum, could been measured. These additional contributions can have a tremendous influence on the performance of the polarimeter and have to be taken into account for further polarimeter designs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA