Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Inverse Probl ; 32(9)2016.
Artigo em Inglês | MEDLINE | ID: mdl-28255191

RESUMO

Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John's equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations and the Fourier-John equation, which are the duals of the consistency equations and John's equation, respectively. We then solve the Fourier consistency equations and Fourier-John equation using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms. Finally, we give numerical examples of implementation of a fast 2D TOF planogram projector and Fourier-based rebinning for a 2D TOF planograms using the FORCEs to show the efficacy of the Fourier-based solutions.

2.
IEEE Trans Nucl Sci ; 63(5): 2599-2606, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27812222

RESUMO

The point-spread-functions (PSFs) of reconstructed images can be deformed due to detector effects such as resolution blurring and parallax error, data acquisition geometry such as insufficient sampling or limited angular coverage in dual-panel PET systems, or reconstruction imperfections/simplifications. PSF deformation decreases quantitative accuracy and its spatial variation lowers consistency of lesion uptake measurement across the imaging field-of-view (FOV). This can be a significant problem with dual panel PET systems even when using TOF data and image reconstruction models of the detector and data acquisition process. To correct for the spatially variant reconstructed PSF distortions we propose to use an image-based resolution model (IRM) that includes such image PSF deformation effects. Originally the IRM was mostly used for approximating data resolution effects of standard PET systems with full angular coverage in a computationally efficient way, but recently it was also used to mitigate effects of simplified geometric projectors. Our work goes beyond this by including into the IRM reconstruction imperfections caused by combination of the limited angle, parallax errors, and any other (residual) deformation effects and testing it for challenging dual panel data with strongly asymmetric and variable PSF deformations. We applied and tested these concepts using simulated data based on our design for a dedicated breast imaging geometry (B-PET) consisting of dual-panel, time-of-flight (TOF) detectors. We compared two image-based resolution models; i) a simple spatially invariant approximation to PSF deformation, which captures only the general PSF shape through an elongated 3D Gaussian function, and ii) a spatially variant model using a Gaussian mixture model (GMM) to more accurately capture the asymmetric PSF shape in images reconstructed from data acquired with the B-PET scanner geometry. Results demonstrate that while both IRMs decrease the overall uptake bias in the reconstructed image, the second one with the spatially variant and accurate PSF shape model is also able to ameliorate the spatially variant deformation effects to provide consistent uptake results independent of the lesion location within the FOV.

3.
Phys Med Biol ; 69(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38330448

RESUMO

Dual panel PET systems, such as Breast-PET (B-PET) scanner, exhibit strong asymmetric and anisotropic spatially-variant deformations in the reconstructed images due to the limited-angle data and strong depth of interaction effects for the oblique LORs inherent in such systems. In our previous work, we studied time-of-flight (TOF) effects and image-based spatially-variant PSF resolution models within dual-panel PET reconstruction to reduce these deformations. The application of PSF based models led to better and more uniform quantification of small lesions across the field of view (FOV). However, the ability of such a model to correct for PSF deformation is limited to small objects. On the other hand, large object deformations caused by the limited-angle reconstruction cannot be corrected with the PSF modeling alone. In this work, we investigate the ability of deep-learning (DL) networks to recover such strong spatially-variant image deformations using first simulated PSF deformations in image space of a generic dual panel PET system and then using simulated and acquired phantom reconstructions from dual panel B-PET system developed in our lab at University of Pennsylvania. For the studies using real B-PET data, the network was trained on the simulated synthetic data sets providing ground truth for objects resembling experimentally acquired phantoms on which the network deformation corrections were then tested. The synthetic and acquired limited-angle B-PET data were reconstructed using DIRECT-RAMLA reconstructions, which were then used as the network inputs. Our results demonstrate that DL approaches can significantly eliminate deformations of limited angle systems and improve their quantitative performance.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Imagens de Fantasmas
4.
IEEE Trans Nucl Sci ; 60(1): 65-75, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23493920

RESUMO

Collimation can improve both the spatial resolution and sampling properties compared to the same scanner without collimation. Spatial resolution improves because each original crystal can be conceptually split into two (i.e., doubling the number of in-plane crystals) by masking half the crystal with a high-density attenuator (e.g., tungsten); this reduces coincidence efficiency by 4× since both crystals comprising the line of response (LOR) are masked, but yields 4× as many resolution-enhanced (RE) LORs. All the new RE LORs can be measured by scanning with the collimator in different configurations. In this simulation study, the collimator was assumed to be ideal, neither allowing gamma penetration nor truncating the field of view. Comparisons were made in 2D between an uncollimated small-animal system with 2-mm crystals that were assumed to be perfectly absorbing and the same system with collimation that narrowed the effective crystal size to 1 mm. Digital phantoms included a hot-rod and a single-hot-spot, both in a uniform background with activity ratio of 4:1. In addition to the collimated and uncollimated configurations, angular and spatial wobbling acquisitions of the 2-mm case were also simulated. Similarly, configurations with different combinations of the RE LORs were considered including (i) all LORs, (ii) only those parallel to the 2-mm LORs; and (iii) only cross pairs that are not parallel to the 2-mm LORs. Lastly, quantitative studies were conducted for collimated and uncollimated data using contrast recovery coefficient and mean-squared error (MSE) as metrics. The reconstructions show that for most noise levels there is a substantial improvement in image quality (i.e., visual quality, resolution, and a reduction in artifacts) by using collimation even when there are 4× fewer counts or - in some cases - comparing with the noiseless uncollimated reconstruction. By comparing various configurations of sampling, the results show that it is the matched combination of both improved spatial resolution of each LOR and the increase in the number of LORs that yields improved reconstructions. Further, the quantitative studies show that for low-count scans, the collimated data give better MSE for small lesions and the uncollimated data give better MSE for larger lesions; for high-count studies, the collimated data yield better quantitative values for the entire range of lesion sizes that were evaluated.

5.
PET Clin ; 16(1): 41-54, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33218603

RESUMO

Total-body PET image reconstruction follows a similar procedure to the image reconstruction process for standard whole-body PET scanners. One unique aspect of total-body imaging is simultaneous coverage of the entire human body, which makes it convenient to perform total-body dynamic PET scans. Therefore, four-dimensional dynamic PET reconstruction and parametric imaging are of great interest in total-body imaging. This article covers some basics of PET image reconstruction and then focuses on three- and four-dimensional PET reconstruction for total-body imaging. Methods for image formation from raw measurements in total-body PET are described. Challenges and opportunities in total-body PET image reconstruction are discussed.


Assuntos
Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Humanos
6.
J Med Imaging (Bellingham) ; 7(3): 032505, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32509914

RESUMO

Purpose: In spite of the general acceptance of iterative reconstruction for clinical use, analytic algorithms provide an important alternative tool due to their linearity, unbiased performance, and predictability for quantitative imaging and quality control studies. On modern time-of-flight (TOF) positron emission tomography scanners with excellent timing resolution, substantial angular compression of (histoprojection) data is possible without loss of resolution, but this also brings challenges for analytical algorithms. We propose TOF and non-TOF Fourier-based analytic approaches that appropriately handle the data sparsity on modern TOF systems. Approach: The proposed TOF algorithm (3D-DIFTOF-direct inversion Fourier transform for TOF) works directly on histoprojection data. The proposed Fourier-based approaches for histoprojection data are further extended to include non-TOF reconstruction (TOF-binned 3D-DIFT), which is particularly useful in time calibration procedures due to its insensitivity to time calibration errors. TOF information is used here to extend available histoprojection data to a larger number of views, essential for artifact-free non-TOF reconstruction. The proposed algorithms are compared with standard analytic techniques on Siemens scanners-space-based confidence-weighted TOF FBP and non-TOF DIFT. Results: 3D-DIFTOF reconstruction demonstrates both improved NEMA-based resolution and contrast versus background variability trade-offs. Similarly, the TOF-binned 3D-DIFT approach shows improved contrast-noise trade-offs over the standard non-TOF approach and is well suited for timing calibration. Conclusions: Our results demonstrate that the proposed 3D-DIFTOF technique provides an improved and more faithful characterization of image resolution compared with standard space-based analytic reconstructions. The proposed tools also provide accurate translation of sparse TOF data available on clinical scanners to upsampled data for non-TOF algorithms.

7.
J Med Imaging (Bellingham) ; 7(3): 032501, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32509913

RESUMO

Guest editors Scott D. Metzler, Samuel Matej, and J. Webster Stayman provide an introduction to the Special Section on Three-Dimensional Image Reconstruction in Nuclear Medicine, PET, and CT.

8.
IEEE Trans Radiat Plasma Med Sci ; 4(5): 603-612, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33163754

RESUMO

Limited-angle data, such as data obtained from a dual-panel Breast-PET scanner, result in substantial image blur in directions coinciding with the missing cone of the image spectrum. On systems with time-of-flight (TOF) capabilities, this blur is reduced as given by the TOF uncertainty, with the image spectrum being correspondingly expanded into the missing spectral cone. Modeling of the TOF uncertainty in the reconstruction is expected to deconvolve this residual TOF blurring. We have however observed that, as a tradeoff, this TOF de-blurring process also introduces ringing artifacts at the edges, analogous to the edge effects observed with line-of-response (LOR) resolution modeling, which attempts to deconvolve the blur due to detector resolution effects. However, in the former case, the ringing artifacts are much wider due to the spatial extent of the TOF uncertainty as compared to the width of typical LOR resolution blur. We illustrate and investigate the effects of using matched, as well as under-modeled and over-modeled, TOF kernels on edge artifacts in reconstruction from limited-angle data, and compare them with TOF reconstructions of complete data. Although for the conventional data with full angular coverage the reconstruction is fairly insensitive to the exact size of the TOF kernel and TOF modeling does not produce ringing artifacts, it is not the case for the limited-angle data. We show that it is important to use some form of regularization of the TOF uncertainty deconvolution process within reconstruction of the limited-angle data, such as decreasing the TOF kernel size.

9.
Phys Med Biol ; 65(23): 235037, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-32340014

RESUMO

Recent research has showed that attenuation images can be determined from emission data, jointly with activity images, up to a scaling constant when utilizing the time-of-flight (TOF) information. We aim to develop practical CT-less joint reconstruction for clinical TOF PET scanners to obtain quantitatively accurate activity and attenuation images. In this work, we present a joint reconstruction of activity and attenuation based on MLAA (maximum likelihood reconstruction of attenuation and activity) with autonomous scaling determination and joint TOF scatter estimation from TOF PET data. Our idea for scaling is to use a selected volume of interest (VOI) in a reconstructed attenuation image with known attenuation, e.g. a liver in patient imaging. First, we construct a unit attenuation medium which has a similar, though not necessarily the same, support to the imaged emission object. All detectable LORs intersecting the unit medium have an attenuation factor of e -1≈ 0.3679, i.e. the line integral of linear attenuation coefficients is one. The scaling factor can then be determined from the difference between the reconstructed attenuation image and the known attenuation within the selected VOI normalized by the unit attenuation medium. A four-step iterative joint reconstruction algorithm is developed. In each iteration, (1) first the activity is updated using TOF OSEM from TOF list-mode data; (2) then the attenuation image is updated using XMLTR-a extended MLTR from non-TOF LOR sinograms; (3) a scaling factor is determined based on the selected VOI and both activity and attenuation images are updated using the estimated scaling; and (4) scatter is estimated using TOF single scatter simulation with the jointly reconstructed activity and attenuation images. The performance of joint reconstruction is studied using simulated data from a generic whole-body clinical TOF PET scanner and a long axial FOV research PET scanner as well as 3D experimental data from the PennPET Explorer scanner. We show that the proposed joint reconstruction with proper autonomous scaling provides low bias results comparable to the reference reconstruction with known attenuation.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total , Simulação por Computador , Humanos
10.
J Inverse Ill Posed Probl ; 28(6): 923-932, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34690436

RESUMO

We present the comparative study of the analytical forward model and the statistical simulation of the Compton single scatter in the Positron Emission Tomography. The formula of the forward model has been obtained using the Single Scatter Simulation approximation under simplified assumptions and therefore we calculate scatter projections using independent Monte Carlo simulation mimicking the scatter physics. The numerical comparative study has been performed using a digital cylindrical phantom filled in with water and containing spherical sources of emission activity located at the central and several displaced positions. Good fits of the formula-based and statistically generated profiles of scatter projections are observed in the presented numerical results.

11.
Phys Med Biol ; 64(22): 225015, 2019 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-31569078

RESUMO

Dual-panel PET system configuration can lead to spatially variable point-spread functions (PSF) of considerable deformations due to depth-of-interaction effects and limited angular coverage. If not modelled properly, these effects result in decreased and inconsistent recovery of lesion activity across the field-of-view (FOV), as well as mispositioning of lesions in the reconstructed image caused by strong PSF asymmetries. We implemented and evaluated models of such PSF deformations with spatially-variant image-based resolution modeling (IRM) within reconstruction (varRM) using the Direct Image REConstruction for Time-of-flight (DIRECT) method and within post-reconstruction deconvolution methods. In addition, DIRECT reconstruction was performed with a spatially-invariant IRM (invRM) and without resolution modeling (noRM) for comparison. The methods were evaluated using simulated data for a realistic breast model with a set of 5 mm lesions located throughout the FOV of a dual-panel Breast-PET scanner. We simulated high-count data to focus on the ability of each method to correctly recover the PSF deformations, and a clinically realistic count level to assess the impact of low count data on the quantitative performance of the evaluated techniques. Performance of the methods evaluated herein was assessed by comparing lesion activity recovery (%BIAS), consistency (%SD) across the FOV, overall error (%RMSE), and recovery of each lesion location. As expected, all techniques using IRM provide considerable improvement over the noRM reconstruction. For the high-count cases, the overall quantitative performance of all IRM techniques, whether within reconstruction or within post-reconstruction, is similar if the lesion location misplacements are ignored. However, invRM provides less consistent performance on activity across lesions and is not able to recover accurate lesion locations. For a clinically realistic count level, varRM reconstruction consistently outperforms all compared approaches, while the post-reconstruction IRM approaches exhibit higher %SD and %RMSE values due to being more affected by the data noise than the within-reconstruction IRM approaches.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Algoritmos , Simulação por Computador , Feminino , Humanos , Modelos Estatísticos , Imagens de Fantasmas , Reprodutibilidade dos Testes
12.
IEEE Trans Radiat Plasma Med Sci ; 1(3): 262-267, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-29270539

RESUMO

Previously, we proposed to use a coincidence collimator to achieve fractional-crystal resolution in PET imaging. We have designed and fabricated a collimator prototype for a small-animal PET scanner, A-PET. To compensate for imperfections in the fabricated collimator prototype, collimator normalization, as well as scanner normalization, is required to reconstruct quantitative and artifact-free images. In this study, we develop a normalization method for the collimator prototype based on the A-PET normalization using a uniform cylinder phantom. We performed data acquisition without the collimator for scanner normalization first, and then with the collimator from eight different rotation views for collimator normalization. After a reconstruction without correction, we extracted the cylinder parameters from which we generated expected emission sinograms. Single scatter simulation was used to generate the scattered sinograms. We used the least-squares method to generate the normalization coefficient for each LOR based on measured, expected and scattered sinograms. The scanner and collimator normalization coefficients were factorized by performing two normalizations separately. The normalization methods were also verified using experimental data acquired from A-PET with and without the collimator. In summary, we developed a model-base collimator normalization that can significantly reduce variance and produce collimator normalization with adequate statistical quality within feasible scan time.

13.
IEEE Trans Med Imaging ; 25(7): 845-54, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16827486

RESUMO

Fourier-based approaches for three-dimensional (3-D) reconstruction are based on the relationship between the 3-D Fourier transform (FT) of the volume and the two-dimensional (2-D) FT of a parallel-ray projection of the volume. The critical step in the Fourier-based methods is the estimation of the samples of the 3-D transform of the image from the samples of the 2-D transforms of the projections on the planes through the origin of Fourier space, and vice versa for forward-projection (reprojection). The Fourier-based approaches have the potential for very fast reconstruction, but their straightforward implementation might lead to unsatisfactory results if careful attention is not paid to interpolation and weighting functions. In our previous work, we have investigated optimal interpolation parameters for the Fourier-based forward and back-projectors for iterative image reconstruction. The optimized interpolation kernels were shown to provide excellent quality comparable to the ideal sinc interpolator. This work presents an optimization of interpolation parameters of the 3-D direct Fourier method with Fourier reprojection (3D-FRP) for fully 3-D positron emission tomography (PET) data with incomplete oblique projections. The reprojection step is needed for the estimation (from an initial image) of the missing portions of the oblique data. In the 3D-FRP implementation, we use the gridding interpolation strategy, combined with proper weighting approaches in the transform and image domains. We have found that while the 3-D reprojection step requires similar optimal interpolation parameters as found in our previous studies on Fourier-based iterative approaches, the optimal interpolation parameters for the main 3D-FRP reconstruction stage are quite different. Our experimental results confirm that for the optimal interpolation parameters a very good image accuracy can be achieved even without any extra spectral oversampling, which is a common practice to decrease errors caused by interpolation in Fourier reconstruction.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons/métodos , Análise de Fourier , Análise Numérica Assistida por Computador , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Phys Med Biol ; 51(11): 2919-37, 2006 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-16723775

RESUMO

In this paper we propose a comprehensive energy-based scatter correction approach for positron emission tomography (PET). We take advantage of the marked difference between the energy spectra of the unscattered and scattered photons, and use the detailed energy information that comes with the list-mode data for the estimation of the scattered events distribution in the data space. Also, inside the maximum-likelihood expectation maximization (ML-EM) image reconstruction algorithm, we introduce energy-dependent factors that individualize the correction terms for each event, given its position and energy information. The central piece of our approach is the two-dimensional detector energy response model represented as a linear combination of four components, each one representing a particular state a PET event can be found in: both photons unscattered, the second scattered while the first not, the first photon scattered while the second not and both photons scattered. For a set of events collected in the vicinity of a point in the projection space, the coefficient of each component is determined by applying a statistical estimator. As a result we obtain the number of scattered events that are in the given set. The model also gives us the variation of scatter fraction with the photon pair energies for that particular position in the data space. A simulation study that demonstrates the proposed methods is presented.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Modelos Biológicos , Modelos Estatísticos , Imagens de Fantasmas , Espalhamento de Radiação
15.
Phys Med Biol ; 61(9): 3365-86, 2016 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-27032968

RESUMO

Iterative reconstruction algorithms are routinely used for clinical practice; however, analytic algorithms are relevant candidates for quantitative research studies due to their linear behavior. While iterative algorithms also benefit from the inclusion of accurate data and noise models the widespread use of time-of-flight (TOF) scanners with less sensitivity to noise and data imperfections make analytic algorithms even more promising. In our previous work we have developed a novel iterative reconstruction approach (DIRECT: direct image reconstruction for TOF) providing convenient TOF data partitioning framework and leading to very efficient reconstructions. In this work we have expanded DIRECT to include an analytic TOF algorithm with confidence weighting incorporating models of both TOF and spatial resolution kernels. Feasibility studies using simulated and measured data demonstrate that analytic-DIRECT with appropriate resolution and regularization filters is able to provide matched bias versus variance performance to iterative TOF reconstruction with a matched resolution model.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Modelos Teóricos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Humanos
16.
Phys Med Biol ; 61(2): 601-24, 2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26689836

RESUMO

Fully 3D time-of-flight (TOF) PET scanners offer the potential of previously unachievable image quality in clinical PET imaging. TOF measurements add another degree of redundancy for cylindrical PET scanners and make photon-limited TOF-PET imaging more robust than non-TOF PET imaging. The data space for 3D TOF-PET data is five-dimensional with two degrees of redundancy. Previously, consistency equations were used to characterize the redundancy of TOF-PET data. In this paper, we first derive two Fourier consistency equations and Fourier-John equation for 3D TOF PET based on the generalized projection-slice theorem; the three partial differential equations (PDEs) are the dual of the sinogram consistency equations and John's equation. We then solve the three PDEs using the method of characteristics. The two degrees of entangled redundancy of the TOF-PET data can be explicitly elicited and exploited by the solutions of the PDEs along the characteristic curves, which gives a complete understanding of the rich structure of the 3D x-ray transform with TOF measurement. Fourier rebinning equations and other mapping equations among different types of PET data are special cases of the general solutions. We also obtain new Fourier rebinning and consistency equations (FORCEs) from other special cases of the general solutions, and thus we obtain a complete scheme to convert among different types of PET data: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF data. The new FORCEs can be used as new Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. Further, we give a geometric interpretation of the general solutions--the two families of characteristic curves can be obtained by respectively changing the azimuthal and co-polar angles of the biorthogonal coordinates in Fourier space. We conclude the unified Fourier theory by showing that the Fourier consistency equations are necessary and sufficient for 3D x-ray transform with TOF measurement. Finally, we give numerical examples of inverse rebinning for a 3D TOF PET and Fourier-based rebinning for a 2D TOF PET using the FORCEs to show the efficacy of the unified Fourier solutions.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Análise de Fourier , Imageamento Tridimensional/métodos
17.
Phys Med Biol ; 60(16): 6563-83, 2015 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-26267223

RESUMO

In positron emission tomography (PET) imaging, attenuation correction with accurate attenuation estimation is crucial for quantitative patient studies. Recent research showed that the attenuation sinogram can be determined up to a scaling constant utilizing the time-of-flight information. The TOF-PET data can be naturally and efficiently stored in a histo-image without information loss, and the radioactive tracer distribution can be efficiently reconstructed using the DIRECT approaches. In this paper, we explore transmission-less attenuation estimation from TOF-PET histo-images. We first present the TOF-PET histo-image formation and the consistency equations in the histo-image parameterization, then we derive a least-squares solution for estimating the directional derivatives of the attenuation factors from the measured emission histo-images. Finally, we present a fast solver to estimate the attenuation factors from their directional derivatives using the discrete sine transform and fast Fourier transform while considering the boundary conditions. We find that the attenuation histo-images can be uniquely determined from the TOF-PET histo-images by considering boundary conditions. Since the estimate of the attenuation directional derivatives can be inaccurate for LORs tangent to the patient boundary, external sources, e.g. a ring or annulus source, might be needed to give an accurate estimate of the attenuation gradient for such LORs. The attenuation estimation from TOF-PET emission histo-images is demonstrated using simulated 2D TOF-PET data.


Assuntos
Algoritmos , Tomografia por Emissão de Pósitrons/métodos
18.
Phys Med Biol ; 60(2): 647-70, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25555160

RESUMO

Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector's intrinsic spatial resolution. To achieve images with better spatial resolution in a central region of interest (ROI), we have previously proposed using collimation in PET scanners. The collimator is designed to partially mask detector crystals to detect lines of response (LORs) within fractional crystals. A sequence of collimator-encoded LORs is measured with different collimation configurations. This novel collimated scanner geometry makes the reconstruction problem challenging, as both detector and collimator effects need to be modeled to reconstruct high-resolution images from collimated LORs. In this paper, we present a LOR-interleaving (LORI) algorithm, which incorporates these effects and has the advantage of reusing existing reconstruction software, to reconstruct high-resolution images for PET with fractional-crystal collimation. We also develop a 3D ray-tracing model incorporating both the collimator and crystal penetration for simulations and reconstructions of the collimated PET. By registering the collimator-encoded LORs with the collimator configurations, high-resolution LORs are restored based on the modeled transfer matrices using the non-negative least-squares method and EM algorithm. The resolution-enhanced images are then reconstructed from the high-resolution LORs using the MLEM or OSEM algorithm. For validation, we applied the LORI method to a small-animal PET scanner, A-PET, with a specially designed collimator. We demonstrate through simulated reconstructions with a hot-rod phantom and MOBY phantom that the LORI reconstructions can substantially improve spatial resolution and quantification compared to the uncollimated reconstructions. The LORI algorithm is crucial to improve overall image quality of collimated PET, which can have significant implications in preclinical and clinical ROI imaging applications.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Humanos , Aumento da Imagem/métodos
19.
IEEE Trans Med Imaging ; 23(4): 401-12, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15084066

RESUMO

Iterative image reconstruction algorithms play an increasingly important role in modern tomographic systems, especially in emission tomography. With the fast increase of the sizes of the tomographic data, reduction of the computation demands of the reconstruction algorithms is of great importance. Fourier-based forward and back-projection methods have the potential to considerably reduce the computation time in iterative reconstruction. Additional substantial speed-up of those approaches can be obtained utilizing powerful and cheap off-the-shelf fast Fourier transform (FFT) processing hardware. The Fourier reconstruction approaches are based on the relationship between the Fourier transform of the image and Fourier transformation of the parallel-ray projections. The critical two steps are the estimations of the samples of the projection transform, on the central section through the origin of Fourier space, from the samples of the transform of the image, and vice versa for back-projection. Interpolation errors are a limitation of Fourier-based reconstruction methods. We have applied min-max optimized Kaiser-Bessel interpolation within the nonuniform FFT (NUFFT) framework and devised ways of incorporation of resolution models into the Fourier-based iterative approaches. Numerical and computer simulation results show that the min-max NUFFT approach provides substantially lower approximation errors in tomographic forward and back-projection than conventional interpolation methods. Our studies have further confirmed that Fourier-based projectors using the NUFFT approach provide accurate approximations to their space-based counterparts but with about ten times faster computation, and that they are viable candidates for fast iterative image reconstruction.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Tomografia Computadorizada de Emissão/métodos , Simulação por Computador , Retroalimentação , Análise de Fourier , Humanos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tórax/diagnóstico por imagem , Tomografia/instrumentação , Tomografia/métodos , Tomografia Computadorizada de Emissão/instrumentação
20.
Nucl Med Commun ; 25(11): 1103-7, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15577588

RESUMO

INTRODUCTION: Fully three-dimensional (3-D) reconstruction algorithms have the potential to better utilize PET data acquired in true 3-D acquisition modes, as compared to 2-D approaches involving data reduction through rebinning procedures followed by a 2-D or 2.5-D reconstruction. Our previous studies, involving simulated and real phantom data from PET scanners working purely in 3-D acquisition mode, showed that the fully 3-D reconstruction approaches bring appreciable improvement on physical measures and visual image quality as well. Reconstruction procedures utilized in those studies were based upon the row action maximum likelihood algorithm (RAMLA) implemented on our clinical scanners. The purpose of this study was to investigate if the fully 3-D RAMLA reconstruction software brings an appreciable improvement in clinical image quality and reader confidence. MATERIALS AND METHODS: Ninety patient scans acquired on the Philips CPET scanner at our institution were reconstructed using 2.5-D RAMLA and 3-D RAMLA with differing reconstruction parameters. These scans were blindly presented to four experienced PET scan readers who graded various aspects of image quality. RESULTS: Our study concluded that 3-D RAMLA on the CPET scanner reduces artifacts and image noise and improves clinical confidence in interpreting PET images. CONCLUSION: This study led to the routine use of 3-D RAMLA reconstruction on the CPET scanner at our institution.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnica de Subtração , Artefatos , Humanos , Imageamento Tridimensional/métodos , Funções Verossimilhança , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA