1.
Radiography (Lond) ; 20(3): 251-257, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26512196

RESUMO

PURPOSE: Quantitative fluoroscopy is an emerging technology for assessing continuous inter-vertebral motion in the lumbar spine, but information on radiation dose is not yet available. The purposes of this study were to compare the radiation dose from quantitative fluoroscopy of the lumbar spine with lumbar spine radiographs, and identify opportunities for dose reduction in quantitative fluoroscopy. METHODS: Internationally reported dose area product (DAP) and effective dose data for lumbar spine radiographs were compared with the same for quantitative fluoroscopy and with data from a local hospital for functional radiographs (weight bearing AP, lateral, and/or flexion and extension) (n = 27). The effects of procedure time, age, weight, height and body mass index on the fluoroscopy dose were determined by multiple linear regression using SPSS v19 software (IBM Corp., Armonck, NY, USA). RESULTS AND CONCLUSION: The effective dose (and therefore the estimated risk) for quantitative fluoroscopy is 0.561 mSv which is lower than in most published data for lumbar spine radiography. The dose area product (DAP) for sagittal (flexion + extension) quantitative fluoroscopy is 3.94 Gy cm2 which is lower than local data for two view (flexion and extension) functional radiographs (4.25 Gy cm2), and combined coronal and sagittal dose from quantitative fluoroscopy (6.13 Gy cm2) is lower than for four view functional radiography (7.34 Gy cm2). Conversely DAP for coronal and sagittal quantitative fluoroscopy combined (6.13 Gy cm2) is higher than that published for both lumbar AP or lateral radiographs, with the exception of Nordic countries combined data. Weight, procedure time and age were independently positively associated with total dose, and height (after adjusting for weight) was negatively associated, thus as height increased, the DAP decreased.

2.
Radiography (Lond) ; 29(5): 941-949, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37531694

RESUMO

INTRODUCTION: Pelvic radiographs are commonly used for the investigation of a variety of conditions. Comparison between examinations requires a consistent radiographic technique but variations in image quality and radiographic centring points are frequently reported in the literature. The aim of this study was to establish the amount of variation in the radiographic centring point (RCP) and pelvic axial rotation (PAR), with a secondary aim of reporting the reliability of such measures. METHODS: Using a previously acquired imaging archive, 633 adult pelvis/hip radiographs were identified on a Picture Archiving and Communication System (PACS). Radiographs with bilateral prostheses, evidence of acute pelvic trauma, projections acquired on a stretcher/trolley and those demonstrating large discontinuity between the detector and X-ray field centre were excluded. To determine centring point variation (+ values denote superior variations) and axial rotation multiple measurements were obtained from each radiograph. A video was used to train five observers and each of these reviewed ten random cases to determine inter- and intra-rater reliability. One of the five observers then performed the measurements on all remaining radiographs. RESULTS: Following exclusions 380 radiographs were evaluated. The median (IQR) RCP deviation from the inter-acetabular line was +22 (+2 to +43) mm where both iliac crests were present and -29 (-45 to -12) mm where they were not. Eleven (3%) cases demonstrate RCP variation from the midline of greater than 25 mm (no bias towards the left or right side). The median (IQR) PAR was 0.0 (-1.5 to 1.4) degrees with greater variance in PAR for male participants (p = 0.004). Almost 60% of inter-rater ICC measurements were categorised as excellent, good or moderate. CONCLUSION: Variations in RCP and PAR exist when evaluating a sample of routinely acquired pelvis radiographs. Some initial factors, such as sex and sub-examination type (full pelvis [XPEL] or low centred pelvis [XHIPB]) have been identified as having a statistical affect on variability. Further research and methods to standardise radiographic techniques is required and must be multidimensional in nature. IMPLICATIONS FOR PRACTICE: Selection of radiographic technique, including RCP, appears to influence components of the pelvis radiograph. Given the increasing clinical requirements for pelvic radiography further standardisation alongside individual optimisation is warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA