Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cardiovasc Revasc Med ; 40S: 135-138, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34426086

RESUMO

A 16-years-old male with prior diagnosis of situs inversus totalis and pulmonary atresia with interventricular communication underwent percutaneous pulmonary valve implantation 3 months after successful RVOT stenting following a negative balloon sizing test. Once finished the procedure, after consciousness recovery in the intensive care unit, the patient developed oppressive chest pain with very subtle electrocardiographic changes over his basal right bundle branch block. An urgent coronary angiography showed a severe stenosis in the proximal right coronary artery with TIMI 2 distal flow. Intravascular ultrasound imaging confirmed extrinsic compression. A 4 × 21 mm drug-eluting stent was successfully implanted relieving symptoms immediately. TIMI 3 flow was restored and good apposition and expansion were confirmed with intravascular ultrasound. A carefully review of the procedure showed that the pitfall responsible for this complication was the oversizing of the valve with respect to the size of the balloon used for the sizing test.


Assuntos
Stents Farmacológicos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar , Valva Pulmonar , Adolescente , Angiografia Coronária , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Stents , Resultado do Tratamento
2.
Rev Esp Cardiol (Engl Ed) ; 74(7): 591-601, 2021 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32830074

RESUMO

INTRODUCTION AND OBJECTIVES: The NitOcclud Lê VSD Coil was specifically designed for transcatheter occlusion of ventricular septal defects (VSD) and became available for this purpose in August 2010. Our objective was to describe the Spanish experience of this technique and analyze its reliability and short- to mid-term efficacy. METHODS: National multicenter observational study, which retrospectively recruited all patients (of any age) with VSD (of any location or type) who underwent percutaneous NitOcclud occlusion, using an intention-to-treat analysis, until January 2019. RESULTS: A total of 117 attempts were made to implant at least 1 NitOcclud in 116 patients in 13 institutions. The median [range] age and weight was 8.6 [0.4-69] years and 27 [5.8-97] kg, respectively. In 99 patients (85%), the VSD was an isolated congenital defect. The location was perimembranous in 95 (81%), and 74 (63%) of them were aneurysmatic. The mean fluoroscopy time was 34 [11.4-124] minutes. Of the 117 attempts, 104 were successful (89%) with a follow-up of 31.4 [0.6-59] months. At the last review, final complete occlusion of the defect without residual shunt or with only a minimal shunt was achieved in 92.3% (no shunt, n=73; trivial shunt, n=23). Four patients required a second procedure for residual shunt occlusion. Two devices had to be surgically explanted due to severe hemolysis. There were no deaths or other major complications. CONCLUSIONS: The NitOcclud device can be used successfully for a wide anatomical spectrum of VSD. The main issue is residual shunt, but its incidence decreases over time. The incidence of hemolysis was very low and no permanent changes were detected in atrioventricular conduction.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular , Comunicação Interventricular/cirurgia , Humanos , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
3.
Rev Esp Cardiol (Engl Ed) ; 69(9): 836-41, 2016 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27156642

RESUMO

INTRODUCTION AND OBJECTIVES: There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. METHODS: Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. RESULTS: We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. CONCLUSIONS: Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved.


Assuntos
Transposição das Grandes Artérias/efeitos adversos , Hipertensão Pulmonar/etiologia , Complicações Pós-Operatórias/epidemiologia , Pressão Propulsora Pulmonar/fisiologia , Transposição dos Grandes Vasos/cirurgia , Cateterismo Cardíaco , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Incidência , Recém-Nascido , Masculino , Estudos Retrospectivos , Espanha/epidemiologia
4.
Rev Esp Cardiol (Engl Ed) ; 65(3): 249-57, 2012 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-22217453

RESUMO

INTRODUCTION AND OBJECTIVES: To adapt the Pediatric Quality of Life Inventory (PedsQL(TM)) (General Module and Cardiac Module, 3.0 version) into Spanish. METHODS: Forward and back translation methodology. Cognitive interviewing was used to check the pre-test version. Psychometric properties were computed for the PedsQL(TM) Cardiac Module Scales. Cross-informant variance between children and parents was assessed. RESULTS: The Spanish version has some format changes to make it easier to read and to clarify response choices (version for 5-7 years age group). Some semantically complex terms were replaced with synonyms and others illustrated with examples. Some "out of context" problems were identified with respect to some items (version for children 2-4 and 5-7 years). The percentage of missing item responses ranged from 0% to 5.9%. A high ceiling effect was found, especially in the Cardiac Module, which ranged from 19% to 48.6%. Internal consistency was higher than 0.7, except for Physical Appearance Scale and School Functioning in children. Agreement between information given by children and parents was generally very high. A decreasing trend in scores on all scales was observed in relation to the severity of heart disease, but the differences were only statistically significant in some dimensions. CONCLUSIONS: The Spanish version of the PedsQL(TM) differs somewhat from the original version, particularly on the School Functioning and Physical Appearance Scales, as observed in cognitive interviews. Predictive validity was not demonstrated.


Assuntos
Cardiopatias/psicologia , Qualidade de Vida , Inquéritos e Questionários , Adolescente , Fatores Etários , Procedimentos Cirúrgicos Cardíacos , Criança , Pré-Escolar , Feminino , Cardiopatias/cirurgia , Humanos , Idioma , Masculino , Pais , Reprodutibilidade dos Testes , Instituições Acadêmicas , Fatores Sexuais , Comportamento Social , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA