Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 26(1): 101035, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38460841

RESUMO

BACKGROUND: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings. PURPOSE: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons. METHODS: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001). CONCLUSION: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner.


Assuntos
Compreensão , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Letramento em Saúde , Educação de Pacientes como Assunto , Doenças Cardiovasculares/diagnóstico por imagem , Feminino , Masculino
2.
Eur Radiol ; 33(8): 5498-5508, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36949253

RESUMO

OBJECTIVES: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS). METHODS: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PE2RT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus). Clinical follow-up data was reviewed up to three years after discharge. The relationship between PE2RT features and the occurrence of MACE (cardiovascular death or new hospitalisation due to acute myocardial injury, arrhythmia, or chronic heart failure) was examined using Cox regression analysis and Kaplan-Meier estimator. RESULTS: Seventy-nine patients (mean age, 68 ± 14 years; 72 women) with TTS were included. CMR was performed in a median of 4 days (IQR, 2-6) after symptom onset. Over a median follow-up of 13.3 months (IQR, 0.4-36.0), MACE occurred in 14/79 (18%) patients: re-hospitalisation due to acute symptoms (9/79, 11%) or chronic heart failure symptoms (4/79, 5%), and cardiac death (1/79, 1%). Patients with MACE had a higher PE2RT score (median [IQR], 2 [2-3] vs 1 [0-1]; p < 0.001). PE2RT score was associated with MACE on Cox regression analysis (hazard ratio per PE2RT feature, 2.44; 95%CI: 1.62-3.68; p < 0.001). Two or more PE2RT complications were strongly associated with the occurrence of MACE (log-rank p < 0.001). CONCLUSIONS: The introduced PE2RT complication score might enable an easy-to-assess outcome evaluation of TTS patients by CMR. KEY POINTS: • Complications like pericardial effusion, pleural effusion, right ventricular involvement, and ventricular thrombus (summarised as PE2RT features) are relatively common in takotsubo syndrome. • The proposed PE2RT score (one point per complication) was associated with the occurrence of major adverse cardiac events on follow-up. • Complications easily detected by cardiac magnetic resonance imaging can help clinicians derive long-term prognostic information on patients with takotsubo syndrome.


Assuntos
Insuficiência Cardíaca , Cardiomiopatia de Takotsubo , Trombose , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Função Ventricular Esquerda , Estudos Retrospectivos , Imageamento por Ressonância Magnética/efeitos adversos , Prognóstico , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética/efeitos adversos , Valor Preditivo dos Testes , Fatores de Risco
3.
BMC Neurol ; 23(1): 86, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36855093

RESUMO

BACKGROUND: Outcome assessment in stroke patients is essential for evidence-based stroke care planning. Computed tomography (CT) is the mainstay of diagnosis in acute stroke. This study aimed to investigate whether CT-derived cervical fat-free muscle fraction (FFMF) as a biomarker of muscle quality is associated with outcome parameters after acute ischemic stroke. METHODS: In this retrospective study, 66 patients (mean age: 76 ± 13 years, 30 female) with acute ischemic stroke in the anterior circulation who underwent CT, including CT-angiography, and endovascular mechanical thrombectomy of the middle cerebral artery between August 2016 and January 2020 were identified. Based on densitometric thresholds, cervical paraspinal muscles covered on CT-angiography were separated into areas of fatty and lean muscle and FFMF was calculated. The study cohort was binarized based on median FFMF (cutoff value: < 71.6%) to compare clinical variables and outcome data between two groups. Unpaired t test and Mann-Whitney U test were used for statistical analysis. RESULTS: National Institute of Health Stroke Scale (NIHSS) (12.2 ± 4.4 vs. 13.6 ± 4.5, P = 0.297) and modified Rankin scale (mRS) (4.3 ± 0.9 vs. 4.4 ± 0.9, P = 0.475) at admission, and pre-stroke mRS (1 ± 1.3 vs. 0.9 ± 1.4, P = 0.489) were similar between groups with high and low FFMF. NIHSS and mRS at discharge were significantly better in patients with high FFMF compared to patients with low FFMF (NIHSS: 4.5 ± 4.4 vs. 9.5 ± 6.7; P = 0.004 and mRS: 2.9 ± 2.1 vs.3.9 ± 1.8; P = 0.049). 90-day mRS was significantly better in patients with high FFMF compared to patients with low FFMF (3.3 ± 2.2 vs. 4.3 ± 1.9, P = 0.045). CONCLUSION: Cervical FFMF obtained from routine clinical CT might be a new imaging-based muscle quality biomarker for outcome prediction in stroke patients.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Projetos Piloto , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Músculos , Acidente Vascular Cerebral/diagnóstico por imagem
4.
J Cardiovasc Magn Reson ; 24(1): 55, 2022 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-36384752

RESUMO

BACKGROUND: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA. METHODS: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied. RESULTS: Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6). CONCLUSION: In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA.


Assuntos
Cardiopatias Congênitas , Angiografia por Ressonância Magnética , Masculino , Humanos , Criança , Pré-Escolar , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Meios de Contraste , Valor Preditivo dos Testes , Cardiopatias Congênitas/diagnóstico por imagem
5.
Radiology ; 301(3): E419-E425, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34374593

RESUMO

Background Myocardial injury and inflammation at cardiac MRI in patients with COVID-19 have been described in recent publications. Concurrently, a chronic COVID-19 syndrome (CCS) after SARS-CoV-2 infection has been observed and manifests with symptoms such as fatigue and exertional dyspnea. Purpose To explore the relationship between CCS and myocardial injury and inflammation as an underlying cause of the persistent complaints in previously healthy individuals. Materials and Methods In this prospective study from January 2021 to April 2021, study participants without known cardiac or pulmonary diseases prior to SARS-CoV-2 infection who had persistent CCS symptoms such as fatigue or exertional dyspnea after convalescence and healthy control participants underwent cardiac MRI. The cardiac MRI protocol included evaluating the T1 and T2 relaxation times, extracellular volume, T2 signal intensity ratio, and late gadolinium enhancement (LGE). Student t tests, Mann-Whitney U tests, and χ2 tests were used for statistical analysis. Results Forty-one participants with CCS (mean age, 39 years ± 13 [standard deviation]; 18 men) and 42 control participants (mean age, 39 years ± 16; 26 men) were evaluated. The median time between the initial incidence of mild to moderate COVID-19 not requiring hospitalization and undergoing cardiac MRI was 103 days (interquartile range, 88-158 days). Troponin T levels were normal. Parameters indicating myocardial inflammation and edema were comparable between participants with CCS and control participants (T1 relaxation times: 978 msec ± 23 vs 971 msec ± 25 [P = .17]; T2 relaxation times: 53 msec ± 2 vs 52 msec ± 2 [P = .47]; T2 signal intensity ratios: 1.6 ± 0.2 vs 1.6 ± 0.3 [P = .10]). Visible myocardial edema was present in none of the participants. Three of 41 (7%) participants with CCS demonstrated nonischemic LGE, whereas no participants in the control group demonstrated nonischemic LGE (0 of 42 [0%]; P = .07). None of the participants fulfilled the 2018 Lake Louise criteria for the diagnosis of myocarditis. Conclusion Individuals with chronic COVID-19 syndrome who did not undergo hospitalization for COVID-19 did not demonstrate signs of active myocardial injury or inflammation at cardiac MRI. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lima and Bluemke in this issue.


Assuntos
COVID-19/diagnóstico , COVID-19/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Miocardite/fisiopatologia , Adulto , COVID-19/complicações , Doença Crônica , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Miocardite/etiologia , Gravidade do Paciente , Estudos Prospectivos , SARS-CoV-2 , Fatores de Tempo
6.
Radiology ; 300(3): 633-640, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34184931

RESUMO

Background Cervical spine CT is regularly performed to exclude cervical spine injury during the initial evaluation of trauma patients. Patients with asymmetry of the lateral atlantodental interval (LADI) often undergo subsequent MRI to rule out ligamentous injuries. The clinical relevance of an asymmetric LADI and the benefit of additional MRI remain unclear. Purpose To evaluate the diagnostic benefit of additional MRI in patients with blunt trauma who have asymmetry of the LADI and no other cervical injuries. Materials and Methods Patients who underwent cervical spine CT during initial trauma evaluation between March 2017 and August 2019 were retrospectively evaluated. Those who underwent subsequent MRI because of LADI asymmetry of 1 mm or greater with no other signs of cervical injury were identified and reevaluated by two readers blinded to clinical data and initial study reports regarding possible ligamentous injuries. Results Among 1553 patients, 146 (9%) had LADI asymmetry of 1 mm or greater. Of these, 46 patients (mean age ± standard deviation, 39 years ± 22; 28 men; median LADI asymmetry, 2.4 mm [interquartile range, 1.8-3.1 mm]) underwent supplementary MRI with no other signs of cervical injury at initial CT. Ten of the 46 patients (22%) showed cervical tenderness at clinical examination, and 36 patients (78%) were asymptomatic. In two of the 46 patients (4%), MRI revealed alar ligament injury; both of these patients showed LADI asymmetry greater than 3 mm, along with cervical tenderness at clinical examination, and underwent treatment for ligamentous injury. In 13 of the 46 patients (28%), signal intensity alterations of alar ligaments without signs of rupture were observed. Four of these 13 patients (31%) were subsequently treated for ligamentous injury despite being asymptomatic. Conclusion Subsequent MRI following CT of the cervical spine in trauma patients with lateral atlantodental interval asymmetry may have diagnostic benefit only in symptomatic patients. In asymptomatic patients without proven cervical injuries, subsequent MRI showed no diagnostic benefit and may even lead to overtreatment. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Vértebras Cervicais/lesões , Ligamentos Articulares/lesões , Imageamento por Ressonância Magnética/métodos , Traumatismos da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Estudos Retrospectivos
7.
Radiology ; 301(3): 602-609, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34581628

RESUMO

Background Immune checkpoint inhibitors (ICIs) for cancer treatment are associated with a spectrum of immune-related adverse events, including ICI-induced myocarditis; however, the extent of subclinical acute cardiac effects related to ICI treatment is unclear. Purpose To explore the extent of cardiac injury and inflammation related to ICI therapy that can be detected with use of cardiac MRI. Materials and Methods In this prospective study from November 2019 to April 2021, oncologic participants, without known underlying structural heart disease or cardiac symptoms, underwent multiparametric cardiac MRI before planned ICI therapy (baseline) and 3 months after starting ICI therapy (follow-up). The cardiac MRI protocol incorporated assessment of cardiac function, including systolic myocardial strain, myocardial edema, late gadolinium enhancement (LGE), T1 and T2 relaxation times, and extracellular volume fraction. The paired t test, Wilcoxon signed-rank test, and McNemar test were used for intraindividual comparisons. Results Twenty-two participants (mean age ± standard deviation, 65 years ± 14; 13 men) were evaluated, receiving a median of four infusions of ICI therapy (interquartile range, four to six infusions). Compared with baseline MRI, participants displayed increased markers of diffuse myocardial edema at follow-up (T1 relaxation time, 972 msec ± 26 vs 1006 msec ± 36 [P < .001]; T2 relaxation time, 54 msec ± 3 vs 58 msec ± 4 [P < .001]; T2 signal intensity ratio, 1.5 ± 0.3 vs 1.7 ± 0.3 [P = .03]). Left ventricular average systolic longitudinal strain had decreased at follow-up MRI (-23.4% ± 4.8 vs -19.6% ± 5.1, respectively; P = .005). New nonischemic LGE lesions were prevalent in two of 22 participants (9%). Compared with baseline, small pericardial effusions were more evident at follow-up (one of 22 participants [5%] vs 10 of 22 [45%]; P = .004). Conclusion In participants who received immune checkpoint inhibitor therapy for cancer treatment, follow-up cardiac MRI scans showed signs of systolic dysfunction and increased parameters of myocardial edema and inflammation. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Inibidores de Checkpoint Imunológico/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Miocardite/induzido quimicamente , Miocardite/diagnóstico por imagem , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos
8.
Eur Radiol ; 31(11): 8807-8815, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33974149

RESUMO

OBJECTIVES: To investigate the diagnostic performance of deep transfer learning (DTL) to detect liver cirrhosis from clinical MRI. METHODS: The dataset for this retrospective analysis consisted of 713 (343 female) patients who underwent liver MRI between 2017 and 2019. In total, 553 of these subjects had a confirmed diagnosis of liver cirrhosis, while the remainder had no history of liver disease. T2-weighted MRI slices at the level of the caudate lobe were manually exported for DTL analysis. Data were randomly split into training, validation, and test sets (70%/15%/15%). A ResNet50 convolutional neural network (CNN) pre-trained on the ImageNet archive was used for cirrhosis detection with and without upstream liver segmentation. Classification performance for detection of liver cirrhosis was compared to two radiologists with different levels of experience (4th-year resident, board-certified radiologist). Segmentation was performed using a U-Net architecture built on a pre-trained ResNet34 encoder. Differences in classification accuracy were assessed by the χ2-test. RESULTS: Dice coefficients for automatic segmentation were above 0.98 for both validation and test data. The classification accuracy of liver cirrhosis on validation (vACC) and test (tACC) data for the DTL pipeline with upstream liver segmentation (vACC = 0.99, tACC = 0.96) was significantly higher compared to the resident (vACC = 0.88, p < 0.01; tACC = 0.91, p = 0.01) and to the board-certified radiologist (vACC = 0.96, p < 0.01; tACC = 0.90, p < 0.01). CONCLUSION: This proof-of-principle study demonstrates the potential of DTL for detecting cirrhosis based on standard T2-weighted MRI. The presented method for image-based diagnosis of liver cirrhosis demonstrated expert-level classification accuracy. KEY POINTS: • A pipeline consisting of two convolutional neural networks (CNNs) pre-trained on an extensive natural image database (ImageNet archive) enables detection of liver cirrhosis on standard T2-weighted MRI. • High classification accuracy can be achieved even without altering the pre-trained parameters of the convolutional neural networks. • Other abdominal structures apart from the liver were relevant for detection when the network was trained on unsegmented images.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Cirrose Hepática/diagnóstico por imagem , Aprendizado de Máquina , Masculino , Estudos Retrospectivos
9.
Eur Radiol ; 31(1): 85-93, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32749584

RESUMO

OBJECTIVES: In patients with advanced liver disease, portal hypertension is an important risk factor, leading to complications such as esophageal variceal bleeding, ascites, and hepatic encephalopathy. This study aimed to determine the diagnostic value of T1 and T2 mapping and extracellular volume fraction (ECV) for the non-invasive assessment of portal hypertension. METHODS: In this prospective study, 50 participants (33 patients with indication for trans-jugular intrahepatic portosystemic shunt (TIPS) and 17 healthy volunteers) underwent MRI. The derivation and validation cohorts included 40 and 10 participants, respectively. T1 and T2 relaxation times and ECV of the liver and the spleen were assessed using quantitative mapping techniques. Direct hepatic venous pressure gradient (HVPG) and portal pressure measurements were performed during TIPS procedure. ROC analysis was performed to compare diagnostic performance. RESULTS: Splenic ECV correlated with portal pressure (r = 0.72; p < 0.001) and direct HVPG (r = 0.50; p = 0.003). No significant correlations were found between native splenic T1 and T2 relaxation times with portal pressure measurements (p > 0.05, respectively). In the derivation cohort, splenic ECV revealed a perfect diagnostic performance with an AUC of 1.000 for the identification of clinically significant portal hypertension (direct HVPG ≥ 10 mmHg) and outperformed other parameters: hepatic T2 (AUC, 0.731), splenic T2 (AUC, 0.736), and splenic native T1 (AUC, 0.806) (p < 0.05, respectively). The diagnostic performance of mapping parameters was comparable in the validation cohort. CONCLUSION: Splenic ECV was associated with portal pressure measurements in patients with advanced liver disease. Future studies should explore the diagnostic value of parametric mapping accross a broader range of pressure values. KEY POINTS: • Non-invasive assessment and monitoring of portal hypertension is an area of unmet interest. • Splenic extracellular volume fraction is strongly associated with portal pressure in patients with end-stage liver disease. • Quantitative splenic and hepatic MRI-derived parameters have a potential to become a new non-invasive diagnostic parameter to assess and monitor portal pressure.


Assuntos
Varizes Esofágicas e Gástricas , Hipertensão Portal , Hemorragia Gastrointestinal , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Pressão na Veia Porta , Estudos Prospectivos , Baço/diagnóstico por imagem
10.
J Cardiovasc Magn Reson ; 23(1): 117, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34689811

RESUMO

BACKGROUND: Cardiovascular magnetic resonance angiography (CMRA) is a non-invasive imaging modality of choice in pediatric patients with congenital heart disease (CHD). This study was aimed to evaluate the diagnostic utility of a respiratory- and electrocardiogram-gated steady-state CMRA with modified Dixon (mDixon) fat suppression technique and compressed sensing in comparison to standard first-pass CMRA in pediatric patients with CHD at 3 T. METHODS: In this retrospective single center study, pediatric CHD patients who underwent CMR with first-pass CMRA followed by mDixon steady-state CMRA at 3 T were analyzed. Image quality using a Likert scale from 5 (excellent) to 1 (non-diagnostic) and quality of fat suppression were assessed in consensus by two readers. Blood-to-tissue contrast and quantitative measurements of the thoracic vasculature were assessed separately by two readers. CMRA images were reevaluated by two readers for additional findings, which could be identified only on either one of the CMRA types. Paired Student t test, Wilcoxon test, and intraclass correlation coefficients (ICCs) were used for statistical analysis. RESULTS: 32 patients with CHD (3.3 ± 1.7 years, 13 female) were included. Overall image quality of steady-state mDixon CMRA was higher compared to first-pass CMRA (4.5 ± 0.5 vs. 3.3 ± 0.5; P < 0.001). Blood-to-tissue contrast ratio of steady-state mDixon CMRA was comparable to first-pass CMRA (7.85 ± 4.75 vs. 6.35 ± 2.23; P = 0.133). Fat suppression of steady-state mDixon CMRA was perfect in 30/32 (94%) cases. Vessel diameters were greater in first-pass CMRA compared to steady-state mDixon CMRA with the greatest differences at the level of pulmonary arteries and veins (e.g., right pulmonary artery for reader 1: 10.4 ± 2.4 vs. 9.9 ± 2.3 mm, P < 0.001). Interobserver agreement was higher for steady-state mDixon CMRA for all measurements compared to first-pass CMRA (ICCs > 0.92). In 9/32 (28%) patients, 10 additional findings were identified on mDixon steady-state CMRA (e.g., partial anomalous venous return, abnormalities of coronary arteries, subclavian artery stenosis), which were not depicted using first-pass CMRA. CONCLUSIONS: Steady-state mDixon CMRA offers a robust fat suppression, a high image quality, and diagnostic utility for the assessment of the thoracic vasculature in pediatric CHD patients.


Assuntos
Cardiopatias Congênitas , Angiografia por Ressonância Magnética , Criança , Meios de Contraste , Vasos Coronários , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Valor Preditivo dos Testes , Estudos Retrospectivos
11.
J Cardiovasc Magn Reson ; 23(1): 91, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-34275486

RESUMO

BACKGROUND: To evaluate a non-contrast respiratory- and electrocardiogram-gated 3D cardiovascular magnetic resonance angiography (CMRA) based on magnetization-prepared Dixon method (relaxation-enhanced angiography without contrast and triggering, REACT) for the assessment of the thoracic vasculature in congenital heart disease (CHD) patients. METHODS: 70 patients with CHD (mean 28 years, range: 10-65 years) were retrospectively identified in this single-center study. REACT-CMRA was applied with respiratory- and cardiac-gating. Image quality (IQ) of REACT-CMRA was compared to standard non-gated multi-phase first-pass-CMRA and respiratory- and electrocardiogram-gated steady-state-CMRA. IQ of different vessels of interest (ascending aorta, left pulmonary artery, left superior pulmonary vein, right coronary ostium, coronary sinus) was independently assessed by two readers on a five-point Likert scale. Measurements of vessel diameters were performed in predefined anatomic landmarks (ascending aorta, left pulmonary artery, left superior pulmonary vein). Both readers assessed artifacts and vascular abnormalities. Friedman test, chi-squared test, and Bland-Altman method were used for statistical analysis. RESULTS: Overall IQ score of REACT-CMRA was higher compared to first-pass-CMRA (3.5 ± 0.4 vs. 2.7 ± 0.4, P < 0.001) and did not differ from steady-state-CMRA (3.5 ± 0.4 vs. 3.5 ± 0.6, P = 0.99). Non-diagnostic IQ of the defined vessels of interest was observed less frequently on REACT-CMRA (1.7 %) compared to steady-state- (4.3 %, P = 0.046) or first-pass-CMRA (20.9 %, P < 0.001). Close agreements in vessel diameter measurements were observed between REACT-CMRA and steady-state-CMRA (e.g. ascending aorta, bias: 0.38 ± 1.0 mm, 95 % limits of agreement (LOA): - 1.62-2.38 mm). REACT-CMRA showed high intra- (bias: 0.04 ± 1.0 mm, 95 % LOA: - 1.9-2.0 mm) and interobserver (bias: 0.20 ± 1.1 mm, 95 % LOA: - 2.0-2.4 mm) agreements regarding vessel diameter measurements. Fat-water separation artifacts were observed in 11/70 (16 %) patients on REACT-CMRA but did not limit diagnostic utility. Six vascular abnormalities were detected on REACT-CMRA that were not seen on standard contrast-enhanced CMRA. CONCLUSIONS: Non-contrast-enhanced cardiac-gated REACT-CMRA offers a high diagnostic quality for assessment of the thoracic vasculature in CHD patients.


Assuntos
Cardiopatias Congênitas , Angiografia por Ressonância Magnética , Meios de Contraste , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
BMC Med Imaging ; 21(1): 65, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827475

RESUMO

BACKGROUND: Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease, characterized by bile duct inflammation and destruction, leading to biliary fibrosis and cirrhosis. The purpose of this study was to investigate the utility of T1 and T2 mapping parameters, including extracellular volume fraction (ECV) for non-invasive assessment of fibrosis severity in patients with PSC. METHODS: In this prospective study, patients with PSC diagnosis were consecutively enrolled from January 2019 to July 2020 and underwent liver MRI. Besides morphological sequences, MR elastography (MRE), and T1 and T2 mapping were performed. ECV was calculated from T1 relaxation times. The presence of significant fibrosis (≥ F2) was defined as MRE-derived liver stiffness ≥ 3.66 kPa and used as the reference standard, against which the diagnostic performance of MRI mapping parameters was tested. Student t test, ROC analysis and Pearson correlation were used for statistical analysis. RESULTS: 32 patients with PSC (age range 19-77 years) were analyzed. Both, hepatic native T1 (r = 0.66; P < 0.001) and ECV (r = 0.69; P < 0.001) correlated with MRE-derived liver stiffness. To diagnose significant fibrosis (≥ F2), ECV revealed a sensitivity of 84.2% (95% confidence interval (CI) 62.4-94.5%) and a specificity of 84.6% (CI 57.8-95.7%); hepatic native T1 revealed a sensitivity of 52.6% (CI 31.7-72.7%) and a specificity of 100.0% (CI 77.2-100.0%). Hepatic ECV (area under the curve (AUC) 0.858) and native T1 (AUC 0.711) had an equal or higher diagnostic performance for the assessment of significant fibrosis compared to serologic fibrosis scores (APRI (AUC 0.787), FIB-4 (AUC 0.588), AAR (0.570)). CONCLUSIONS: Hepatic T1 and ECV can diagnose significant fibrosis in patients with PSC. Quantitative mapping has the potential to be a new non-invasive biomarker for liver fibrosis assessment and quantification in PSC patients.


Assuntos
Colangite Esclerosante/complicações , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
13.
Pediatr Radiol ; 51(13): 2470-2480, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34435226

RESUMO

BACKGROUND: The diagnostic value of cardiac magnetic resonance imaging (MRI) employing the 2018 Lake Louise criteria in pediatric and adolescent patients with acute myocarditis is undefined. OBJECTIVE: To evaluate the diagnostic value of the Lake Louise criteria in pediatric and adolescent patients with suspected acute myocarditis and to show the utility of cardiac MRI for follow-up in this patient cohort. MATERIALS AND METHODS: Forty-three patients (age range: 8-21 years) with suspected acute myocarditis and 13 control patients who underwent cardiac MRI were retrospectively analyzed. T2-weighted and late gadolinium enhancement imaging were performed in all patients. T1 and T2 mapping were available in 26/43 patients (60%). The Lake Louise criteria were assessed. In 27/43 patients (63%), cardiac MRI follow-up was available. Receiver operating characteristic analysis, Pearson's correlation coefficient and paired Student's t-test were used for statistical analysis. RESULTS: In the total cohort, the Lake Louise criteria achieved a sensitivity of 86% (95% confidence interval [CI]: 72-95%) and a specificity of 100% (95% CI: 79-100%) for the diagnosis of acute myocarditis. In the subgroup of patients with available mapping parameters, the diagnostic performance of the Lake Louise criteria was higher when mapping parameters were implemented into the score (area under the receiver operating characteristic curve: 0.944 vs. 0.870; P=0.033). T2 relaxation times were higher in patients with admission to the intermediate care unit and were associated with the length of intermediate care unit stay (r=0.879, P=0.049). Cardiac MRI markers of active inflammation decreased on follow-up examinations (e.g., T1 relaxation times: 1,032±39 ms vs. 975±33 ms, P<0.001; T2 relaxation times: 58±5 ms vs. 54±5 ms, P=0.003). CONCLUSION: The Lake Louise criteria have a high diagnostic performance for the diagnosis of acute myocarditis and are a valuable tool for follow-up in pediatric and adolescent patients. The mapping techniques enhance the diagnostic performance of the 2018 Lake Louise criteria.


Assuntos
Miocardite , Doença Aguda , Adolescente , Adulto , Criança , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Miocardite/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
14.
J Cardiovasc Magn Reson ; 22(1): 63, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-32892751

RESUMO

BACKGROUND: Myocardial native T1 and T2 relaxation time mapping are sensitive to pathological increase of myocardial water content (e.g. myocardial edema). However, the influence of physiological hydration changes as a possible confounder of relaxation time assessment has not been studied. The purpose of this study was to evaluate, whether changes in myocardial water content due to dehydration and hydration might alter myocardial relaxation times in healthy subjects. METHODS: A total of 36 cardiovascular magnetic resonance (CMR) scans were performed in 12 healthy subjects (5 men, 25.8 ± 3.2 years). Subjects underwent three successive CMR scans: (1) baseline scan, (2) dehydration scan after 12 h of fasting (no food or water), (3) hydration scan after hydration. CMR scans were performed for the assessment of myocardial native T1 and T2 relaxation times and cardiac function. For multiple comparisons, repeated measures ANOVA or the Friedman test was used. RESULTS: There was no change in systolic blood pressure or left ventricular ejection fraction between CMR scans (P > 0.05, respectively). T1 relaxation times were significantly reduced with dehydration (987 ± 27 ms [baseline] vs. 968 ± 29 ms [dehydration] vs. 986 ± 28 ms [hydration]; P = 0.006). Similar results were observed for T2 relaxation times (52.9 ± 1.8 ms [baseline] vs. 51.5 ± 2.0 ms [dehydration] vs. 52.2 ± 1.9 ms [hydration]; P = 0.020). CONCLUSIONS: Dehydration may lead to significant alterations in relaxation times and thereby may influence precise, repeatable and comparable assessment of native T1 and T2 relaxation times. Hydration status should be recognized as new potential confounder of native T1 and T2 relaxation time assessment in clinical routine.


Assuntos
Composição Corporal , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Estado de Hidratação do Organismo , Função Ventricular Esquerda , Equilíbrio Hidroeletrolítico , Adulto , Desidratação , Diástole , Feminino , Voluntários Saudáveis , Coração/fisiologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
15.
Sci Rep ; 14(1): 497, 2024 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-38177651

RESUMO

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.


Assuntos
Implantes Dentários , Artefatos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Bochecha , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
16.
Heliyon ; 10(6): e28142, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38533048

RESUMO

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38912832

RESUMO

AIMS: To evaluate different cardiovascular magnetic resonance (CMR) parameters for the differentiation of light chain amyloidosis (AL) and transthyretin-related amyloidosis (ATTR). METHODS AND RESULTS: In total, 75 patients, 53 with cardiac amyloidosis (20 patients with AL (66±12 years, 14 males [70%]) and 33 patients with ATTR (78±5 years, 28 males [88%])) were retrospectively analyzed regarding CMR parameters such as T1 and T2 mapping, extracellular volume (ECV), and late gadolinium enhancement (LGE) distribution patterns, and myocardial strain, and compared to a control cohort with other causes of left ventricular hypertrophy (LVH; 22 patients (53±16 years, 17 males [85%])). One way-ANOVA and receiver operating characteristic analysis were used for statistical analysis. ECV was the single best parameter to differentiate between cardiac amyloidosis and controls (area under the curve [AUC]: 0.97, 95% confidence intervals [CI]: 0.89-0.99, p<.0001, cutoff: >30%). T2 mapping was the best single parameter to differentiate between AL and ATTR amyloidosis (AL: 63±4 ms, ATTR: 58±2 ms, p<.001, AUC: 0.86, 95% CI: 0.74-0.94, cutoff: >61 ms). Subendocardial LGE was predominantly observed in AL patients (10/20 [50%] vs. 5/33 [15%]; p=.002). Transmural LGE was predominantly observed in ATTR patients (23/33 [70%] vs. 2/20 [10%]; p<.001). The diagnostic performance of T2 mapping to differentiate between AL and ATTR amyloidosis was further increased with the inclusion of LGE patterns (AUC: 0.96, 95% CI: 0.86-0.99]; p=.05). CONCLUSION: ECV differentiates cardiac amyloidosis from other causes of LVH. T2 mapping combined with LGE differentiates AL from ATTR amyloidosis with high accuracy on a patient level.

18.
Cardiovasc Intervent Radiol ; 46(5): 658-663, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36826490

RESUMO

PURPOSE: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup. MATERIALS AND METHODS: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc., USA). To assess the radial forces of the VCX above 8 mm, balloon expansion was performed between cycles. RESULTS: All VCX stents show an abrupt decrease in COF at an external diameter of 8.3 mm; RRF decreases likewise at an external diameter of 8.5 mm. The predecessor VIATORR stent without the "controlled expansion" feature shows linear radial force reduction until full expansion at a diameter of 10 mm. The physical properties of the VCX can be altered by balloon modulation. Point of COF (RRF) reduction shifts to 8.5 mm (8.6 mm), 8.6 mm (8.8 mm) and 9.3 mm (9.6 mm) following modulation with a 8 mm, 9 mm and 10 mm balloon. CONCLUSIONS: The VCX shows an abrupt and disproportionate decrease in COF and RRF at an external diameter of 8.3 mm, thus passive expansion to its nominal diameter of 10 mm is not to be expected. By means of balloon dilatation the physical properties of the stent can be altered, enabling customized TIPS creation. The previous VIATORR stent shows continuous COF and RRF until total expansion.


Assuntos
Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Stents , Desenho de Prótese
19.
Sci Rep ; 13(1): 8955, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268675

RESUMO

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Estudos Retrospectivos , Metais , Tomografia Computadorizada por Raios X/métodos , Artefatos , Algoritmos
20.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070533

RESUMO

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Neoplasias da Próstata/diagnóstico por imagem , Razão Sinal-Ruído , Artefatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA