Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Gynecol Obstet Fertil Senol ; 50(3): 220-228, 2022 Mar.
Artigo em Francês | MEDLINE | ID: mdl-34500133

RESUMO

OBJECTIVE: The integration of couples in decision making in obstetrics is necessary to improve the experience of giving birth. The objective of this work is to elaborate a new tool to provide information to health professionals. METHODS: A 5-round Delphi method was used to define the information points. The 20 multi-disciplinary experts answered 5 surveys on the information to deliver concerning childbirth. The selected items were organized with mind mapping. RESULTS: 54 items were identified on the first round. 5 were retained after the second survey while the rest were reformulated and submitted for the third round. Amongst the 47 items submitted, 19 were retained, the rest were removed, merged or reworded. The fourth survey included 22 items of which 11 were retained. The fifth survey concerned the 11 remaining items and 2 new ones. During this round, 7 items were retained. This round made it possible to reach the consensus. In total, 42 items reached the consensus of the experts. They were then split into 5 mind maps allowing their visual organization to form the information tool. CONCLUSION: The tool elaborated in a multi-disciplinary manner offers complementary information to that already given during childbirth preparation courses. It is a framework for the information to be given that leaves the content up to each professional.


Assuntos
Pessoal de Saúde , Trabalho de Parto , Consenso , Técnica Delphi , Feminino , Humanos , Gravidez , Inquéritos e Questionários
2.
Gynecol Obstet Fertil Senol ; 48(11): 814-819, 2020 11.
Artigo em Francês | MEDLINE | ID: mdl-32184177

RESUMO

The Odon Device™ has been described in the literature since 2013 and the World Health Organization supports its development through the Human Reproduction Program. This innovative device could be easier to use than usual instruments and could be an alternative to caesarean section during the second stage of labor, especially in countries where access to obstetric care is limited. The aim of the Odon Device™ is to position an air cuff over the fetal head, past its widest point (around the level of the fetal mouth anteriorly and the nape of the fetal neck posteriorly). Three mechanical principles favor the progression of the fetal head with the Odon Device™: partial propulsion, limited flexion and traction. Preliminary clinical studies on animals and simulators are reassuring and show that an appropriate use is no more at risk than the vaccum or forceps. A phase 1 study was conducted in Argentina and South Africa between 2011 and 2017. The reported failure rate was 29%, of which 77% was secondary to a mechanical failure of one of the components of the device. Improvements concerning the applicator, the handles and the inflatable air cuff have been made to the device. Phase II of the clinical research program began in 2018 and includes two studies in two different centers: The ASSIST Study in Bristol, England, and The BESANCON ASSIST Study, Besançon, France.


Assuntos
Extração Obstétrica , Trabalho de Parto , Animais , Cesárea , Feminino , Feto , Cabeça , Humanos , Gravidez
3.
Diagn Interv Imaging ; 101(2): 69-78, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31447393

RESUMO

PURPOSE: The first aim was to evaluate feasibility and reproducibility of 2-dimensional ultrasound (2D) shear wave elastography (SWE) of human fetal lungs and liver between 24 and 34weeks of gestation. The second aim was to model fetal lung-to-liver elastography ratio (LLE ratio) and to assess its variations according to gestational age and maternal administration of corticosteroids. MATERIAL AND METHODS: 2D-SWE examinations were prospectively performed in fetuses of women with an uncomplicated pregnancy (group 1) and fetuses of women with a threatened preterm labor requiring administration of corticosteroids (group 2). Two 2D-SWE examinations were performed at "day 0" and "day 2" in group 1; before and 24hours after a course of corticosteroid in group 2. Three operators performed 2 cycles of 3 measurements on the lung (regions A1, A2, A3) and the liver (regions IV, V, VI). Repeatability and reproducibility of measurements were calculated. The fetal LLE ratio was modeled from the most reproducible regions. RESULTS: Fifty-five women were enrolled in group 1 and 48 in group 2. For the lung, 8.6% of measurements were considered invalid and 6.9% for the liver. The most reproducible region for the lung was A3 [ICC between 0.70 (95% CI: 0.42-0.85) and 0.78 (95% CI: 0.48-0.90)] and region VI for the liver [ICC between 0.70 (95% CI: 0.40-0.85) and 0.84 (95% CI: 0.60-0.94)]. According to gestational age, a moderate positive linear correlation was found for stiffness values of A3 (R=0.56), V (R=0.46) and VI (R=0.44). LLE ratio values at "day 0" were not different between the two groups but decreased at "day 2" in group 2 (0.2; 95% CI: 0.07-0.34; P<0.001). CONCLUSION: Quantitative fetal lung and liver stiffness measurements are possible with 2D-SWE with acceptable reproducibility.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Fígado/embriologia , Pulmão/diagnóstico por imagem , Pulmão/embriologia , Adulto , Estudos de Casos e Controles , Técnicas de Imagem por Elasticidade/métodos , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Projetos Piloto , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal , Adulto Jovem
4.
Gynecol Obstet Fertil Senol ; 47(9): 672-679, 2019 09.
Artigo em Francês | MEDLINE | ID: mdl-31200108

RESUMO

OBJECTIVE: The aim of our study was to evaluate the safety and the benefits of manual rotation in the management of Occiput-posterior positions in 2019. METHODS: A systematic review of literature was performed using the MEDLINE and COCHRANE LIBRARY databases, in order to identify articles concerning maternal and neonatal outcomes after a manual rotation, through January 2019. Information on study characteristics (review, author, year of publication), population, objectives and main neonatal and maternal outcomes were extracted. RESULTS: A total of 51 articles were identified and 12 articles were selected for the systematic review. The rate of successful manual rotation were about 47 to 90%. There were more success if systematic manual rotation, multiparity, engagement, spontaneous labour and maternal age<35. The 2nd stage of labour was shorter after an attempt of manual rotation. The randomised controlled trials did not find any statistical difference concerning operative deliveries or neonatal and maternal outcomes. CONCLUSION: The manual rotation is an obstetrical manoeuvre which must be regulated and only practiced by trained operators. Currently, the state of science is not sufficient to recommend the manual rotation as a systematic practice in 2019.


Assuntos
Apresentação no Trabalho de Parto , Resultado da Gravidez , Versão Fetal/efeitos adversos , Versão Fetal/métodos , Cesárea , Parto Obstétrico/instrumentação , Parto Obstétrico/métodos , Feminino , Feto/fisiologia , Humanos , Recém-Nascido , Trabalho de Parto , MEDLINE , Saúde Materna , Gravidez , Ultrassonografia Pré-Natal
5.
Phys Sportsmed ; 27(7): 41-56, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20086732

RESUMO

Proper golf technique and equipment and preventive measures can minimize golf-related injuries of the back, shoulders, elbows, and hands and wrists. Rotating the shoulder and hip a similar amount during the backswing and keeping the spine vertical during the follow-through can reduce lumbar spine strain. A rigid back support may lower the risk of vertebral compression fracture in osteoporotic patients. Shortening the backswing can decrease pressure on a degenerative acromioclavicular joint. Therapy for 'golfer's elbow' includes medial counterforce bracing, larger club grips, and graphite shafts. Treatments for wrist and hand disorders include proper swing and grip technique and larger, softer grips. Diagnosis of the easy-to-miss fracture of the hook of the hamate may require tomogram, CT, or MRI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA