Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(6): 1046-1053, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36645354

RESUMO

OBJECTIVES: The aim was to evaluate the stability of serum bicarbonate at room temperature, depending on time to centrifugation and air exposure. METHODS: Stability study was conducted in the laboratory of Clinical Hospital Centre Rijeka, Croatia in January-February 2022. Nine samples from 10 volunteers were collected in clot activator gel tubes (Greiner Bio-One). Bicarbonate was measured on Beckman Coulter AU480 (Beckman Coulter, Brea, USA). Three tubes were left at room temperature for 30 min, three tubes for 2 h, three tubes for 4 h until centrifugation. First tube from first group (baseline) was measured immediately after centrifugation. Other measurements were expressed as percentage deviation (PD%) from baseline. First tube was remeasured after 1 and 2 h (OT_0h_1h; OT_0h_2h). Second and third tubes were opened 1 and 2 h after centrifugation (C_0h_1h; C_0h_2h). Second group of tubes was processed the same way with 2-hour centrifugation delay (WB_2h; OT_2h_1h; OT_2h_2h; C_2h_1h; C_2h_2h), and third group with 4-hour delay (WB_4h; OT_4h_1h; OT_4h_2h; C_4h_1h; C_4h_2h). PD% was compared to Maximum Permissible Difference (MPD=5.69%). MedCalc statistical software was used (MedCalc, Ostend, Belgium). RESULTS: Bicarbonate baseline mean value (range) was 27.3 (23.4-29.6) mmol/L. Obtained PD% (95%CI) were: C_0h_1h 0.46 (-1.21, 2.12); C_0h_2h 0.18 (-2.22, 2.57); OT_0h_1h -6.46 (-7.57, -5.36); OT_0h_2h -10.67 (-12.13, -9.21); WB_2h -0.15 (-2.04, 1.74); C_2h_1h 0.01 (-1.52, 1.54); C_2h_2h -0.40 (-2.65, 1.85); OT_2h_1h -5.43 (-7.30, -3.55); OT_2h_2h -11.32 (-13.57, -9.07); WB_4h -0.85 (-3.28, 1.58); C_4h_1h -2.52 (-4.93, 0.11); C_4h_2h -3.02 (-5.62, 0.43); OT_4h_1h -7.34 (-9.64, -5.05); OT_4h_2h -11.85 (-14.38, -9.33). CONCLUSIONS: Serum bicarbonate is stable for 4 h in closed uncentrifuged tubes, another 2 h in closed tubes after centrifugation, and is unstable within 1 h in opened tube.


Assuntos
Bicarbonatos , Brassicaceae , Humanos , Coleta de Amostras Sanguíneas , Temperatura , Lista de Checagem , Centrifugação
2.
Biochem Med (Zagreb) ; 32(1): 010501, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35210925

RESUMO

The sweat test (ST) is a cornerstone in the diagnosis of cystic fibrosis (CF), together with newborn screening and genetic testing. However, the performance of the ST can depend on the operator's skill, so several international guidelines have been published to standardise the ST, but inconsistencies remain. The joint Working Group for ST Standardisation (WG STS) of the Croatian Society of Medical Biochemistry and Laboratory Medicine, in association with cistic fybrosis health professional and the Cistic Fibrosis Centre for Paediatrics and Adults, have issued National Guidelines for the Performance of the Sweat Test in order to ensure consistency in ST performance and accuracy of reported results. Many of the standards were taken from the 2nd Edition of the UK Guidelines for Performance of the ST for the Diagnosis of CF, while others were taken from independent consensus statements from the WG STS based on local ST equipment and practices. The standards cover every step of the ST, from the indications for testing to reporting of results and their interpretation, including the analytical phase and quality control. In addition, National Guidelines include appendices with practical examples in order to aid implementation of the recommendations in routine practice.


Assuntos
Fibrose Cística , Pediatria , Criança , Fibrose Cística/diagnóstico , Hospitais Universitários , Humanos , Recém-Nascido , Laboratórios , Suor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA