RESUMO
Interlayer excitons (ILXs) - electron-hole pairs bound across two atomically thin layered semiconductors - have emerged as attractive platforms to study exciton condensation1-4, single-photon emission and other quantum information applications5-7. Yet, despite extensive optical spectroscopic investigations8-12, critical information about their size, valley configuration and the influence of the moiré potential remains unknown. Here, in a WSe2/MoS2 heterostructure, we captured images of the time-resolved and momentum-resolved distribution of both of the particles that bind to form the ILX: the electron and the hole. We thereby obtain a direct measurement of both the ILX diameter of around 5.2 nm, comparable with the moiré-unit-cell length of 6.1 nm, and the localization of its centre of mass. Surprisingly, this large ILX is found pinned to a region of only 1.8 nm diameter within the moiré cell, smaller than the size of the exciton itself. This high degree of localization of the ILX is backed by Bethe-Salpeter equation calculations and demonstrates that the ILX can be localized within small moiré unit cells. Unlike large moiré cells, these are uniform over large regions, allowing the formation of extended arrays of localized excitations for quantum technology.
RESUMO
Halide perovskite materials have promising performance characteristics for low-cost optoelectronic applications. Photovoltaic devices fabricated from perovskite absorbers have reached power conversion efficiencies above 25 per cent in single-junction devices and 28 per cent in tandem devices1,2. This strong performance (albeit below the practical limits of about 30 per cent and 35 per cent, respectively3) is surprising in thin films processed from solution at low-temperature, a method that generally produces abundant crystalline defects4. Although point defects often induce only shallow electronic states in the perovskite bandgap that do not affect performance5, perovskite devices still have many states deep within the bandgap that trap charge carriers and cause them to recombine non-radiatively. These deep trap states thus induce local variations in photoluminescence and limit the device performance6. The origin and distribution of these trap states are unknown, but they have been associated with light-induced halide segregation in mixed-halide perovskite compositions7 and with local strain8, both of which make devices less stable9. Here we use photoemission electron microscopy to image the trap distribution in state-of-the-art halide perovskite films. Instead of a relatively uniform distribution within regions of poor photoluminescence efficiency, we observe discrete, nanoscale trap clusters. By correlating microscopy measurements with scanning electron analytical techniques, we find that these trap clusters appear at the interfaces between crystallographically and compositionally distinct entities. Finally, by generating time-resolved photoemission sequences of the photo-excited carrier trapping process10,11, we reveal a hole-trapping character with the kinetics limited by diffusion of holes to the local trap clusters. Our approach shows that managing structure and composition on the nanoscale will be essential for optimal performance of halide perovskite devices.
RESUMO
BACKGROUND & AIMS: Oral antiviral therapy with nucleos(t)ide analogues (NAs) for chronic hepatitis B (CHB) is well-tolerated and lifesaving, but real-world data on utilization are limited. We examined rates of evaluation and treatment in patients from the REAL-B consortium. METHODS: This was a cross-sectional study nested within our retrospective multinational clinical consortium (2000-2021). We determined the proportions of patients receiving adequate evaluation, meeting AASLD treatment criteria, and initiating treatment at any time during the study period. We also identified factors associated with receiving adequate evaluation and treatment using multivariable logistic regression analyses. RESULTS: We analyzed 12,566 adult treatment-naïve patients with CHB from 25 centers in 9 countries (mean age 47.1 years, 41.7% female, 96.1% Asian, 49.6% Western region, 8.7% cirrhosis). Overall, 73.3% (9,206 patients) received adequate evaluation. Among the adequately evaluated, 32.6% (3,001 patients) were treatment eligible by AASLD criteria, 83.3% (2,500 patients) of whom were initiated on NAs, with consistent findings in analyses using EASL criteria. On multivariable logistic regression adjusting for age, sex, cirrhosis, and ethnicity plus region, female sex was associated with adequate evaluation (adjusted odds ratio [aOR] 1.13, p = 0.004), but female treatment-eligible patients were about 50% less likely to initiate NAs (aOR 0.54, p <0.001). Additionally, the lowest evaluation and treatment rates were among Asian patients from the West, but no difference was observed between non-Asian patients and Asian patients from the East. Asian patients from the West (vs. East) were about 40-50% less likely to undergo adequate evaluation (aOR 0.60) and initiate NAs (aOR 0.54) (both p <0.001). CONCLUSIONS: Evaluation and treatment rates were suboptimal for patients with CHB in both the East and West, with significant sex and ethnic disparities. Improved linkage to care with linguistically competent and culturally sensitive approaches is needed. IMPACT AND IMPLICATIONS: Significant sex and ethnic disparities exist in hepatitis B evaluation and treatment, with female treatment-eligible patients about 50% less likely to receive antiviral treatment and Asian patients from Western regions also about 50% less likely to receive adequate evaluation or treatment compared to Asians from the East (there was no significant difference between Asian patients from the East and non-Asian patients). Improved linkage to care with linguistically competent and culturally sensitive approaches is needed.
Assuntos
Antivirais , Disparidades em Assistência à Saúde , Hepatite B Crônica , Humanos , Feminino , Masculino , Antivirais/uso terapêutico , Estudos Transversais , Pessoa de Meia-Idade , Estudos Retrospectivos , Hepatite B Crônica/tratamento farmacológico , Hepatite B Crônica/etnologia , Adulto , Disparidades em Assistência à Saúde/estatística & dados numéricos , Disparidades em Assistência à Saúde/etnologia , Fatores Sexuais , Etnicidade/estatística & dados numéricos , Saúde GlobalRESUMO
BACKGROUND AND AIMS: The importance of withdrawal time during colonoscopy cannot be overstated in mitigating the risk of missed lesions and postcolonoscopy colorectal cancer. We evaluated a novel colonoscopy quality metric called the effective withdrawal time (EWT), which is an artificial intelligence (AI)-derived quantitative measure of quality withdrawal time, and its association with various colonic lesion detection rates as compared with standard withdrawal time (SWT). METHODS: Three hundred fifty video recordings of colonoscopy withdrawal (from the cecum to the anus) were assessed by the new AI model. The primary outcome was adenoma detection rate (ADR) according to different quintiles of EWT. Multivariate logistic regression, adjusting for baseline covariates, was used to determine the adjusted odd ratios (ORs) for EWT on lesion detection rates, with the lowest quintile as reference. The area under the receiver-operating characteristic curve of EWT was compared with SWT. RESULTS: The crude ADR in different quintiles of EWT, from lowest to highest, was 10.0%, 31.4%, 33.3%, 53.5%, and 85.7%. The ORs of detecting adenomas and polyps were significantly higher in all top 4 quintiles when compared with the lowest quintile. Each minute increase in EWT was associated with a 49% increase in ADR (aOR, 1.49; 95% confidence interval [CI], 1.36-1.65). The area under the receiver-operating characteristic curve of EWT was also significantly higher than SWT on adenoma detection (.80 [95% CI, .75-.84] vs .70 [95% CI, .64-.74], P < .01). CONCLUSIONS: AI-derived monitoring of EWT is a promising novel quality indicator for colonoscopy, which is more associated with ADR than SWT.
Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Inteligência Artificial , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Colonoscopia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Adenoma/diagnóstico , Adenoma/patologiaRESUMO
Valid, responsive blood biomarkers specific to peripheral nerve damage would improve management of peripheral nervous system (PNS) diseases. Neurofilament light chain (NfL) is sensitive for detecting axonal pathology but is not specific to PNS damage, as it is expressed throughout the PNS and CNS. Peripherin, another intermediate filament protein, is almost exclusively expressed in peripheral nerve axons. We postulated that peripherin would be a promising blood biomarker of PNS axonal damage. We demonstrated that peripherin is distributed in sciatic nerve, and to a lesser extent spinal cord tissue lysates, but not in brain or extra-neural tissues. In the spinal cord, anti-peripherin antibody bound only to the primary cells of the periphery (anterior horn cells, motor axons and primary afferent sensory axons). In vitro models of antibody-mediated axonal and demyelinating nerve injury showed marked elevation of peripherin levels only in axonal damage and only a minimal rise in demyelination. We developed an immunoassay using single molecule array technology for the detection of serum peripherin as a biomarker for PNS axonal damage. We examined longitudinal serum peripherin and NfL concentrations in individuals with Guillain-Barré syndrome (GBS, n = 45, 179 time points), chronic inflammatory demyelinating polyradiculoneuropathy (CIDP, n = 35, 70 time points), multiple sclerosis (n = 30), dementia (as non-inflammatory CNS controls, n = 30) and healthy individuals (n = 24). Peak peripherin levels were higher in GBS than all other groups (median 18.75 pg/ml versus < 6.98 pg/ml, P < 0.0001). Peak NfL was highest in GBS (median 220.8 pg/ml) and lowest in healthy controls (median 5.6 pg/ml), but NfL did not distinguish between CIDP (17.3 pg/ml), multiple sclerosis (21.5 pg/ml) and dementia (29.9 pg/ml). While peak NfL levels were higher with older age (rho = +0.39, P < 0.0001), peak peripherin levels did not vary with age. In GBS, local regression analysis of serial peripherin in the majority of individuals with three or more time points of data (16/25) displayed a rise-and-fall pattern with the highest value within the first week of initial assessment. Similar analysis of serial NfL concentrations showed a later peak at 16 days. Group analysis of serum peripherin and NfL levels in GBS and CIDP patients were not significantly associated with clinical data, but in some individuals with GBS, peripherin levels appeared to better reflect clinical outcome measure improvement. Serum peripherin is a promising new, dynamic and specific biomarker of acute PNS axonal damage.
Assuntos
Demência , Síndrome de Guillain-Barré , Esclerose Múltipla , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica , Humanos , Periferinas/metabolismo , Filamentos Intermediários , Síndrome de Guillain-Barré/patologia , Axônios/patologia , Biomarcadores , Demência/patologia , Esclerose Múltipla/patologiaRESUMO
BACKGROUND AND AIMS: Computer-assisted detection (CADe) is a promising technologic advance that enhances adenoma detection during colonoscopy. However, the role of CADe in reducing missed colonic lesions is uncertain. The aim of this study was to determine the miss rates of proximal colonic lesions by CADe and conventional colonoscopy. METHODS: This was a prospective, multicenter, randomized, tandem-colonoscopy study conducted in 3 Asian centers. Patients were randomized to receive CADe or conventional white-light colonoscopy during the first withdrawal of the proximal colon (cecum to splenic flexure), immediately followed by tandem examination of the proximal colon with white light in both groups. The primary outcome was adenoma/polyp miss rate, which was defined as any adenoma/polyp detected during the second examination. RESULTS: Of 223 patients (48.6% men; median age, 63 years) enrolled, 7 patients did not have tandem examination, leaving 108 patients in each group. There was no difference in the miss rate for proximal adenomas (CADe vs conventional: 20.0% vs 14.0%, P = .07) and polyps (26.7% vs 19.6%, P = .06). The CADe group, however, had significantly higher proximal polyp (58.0% vs 46.7%, P = .03) and adenoma (44.7% vs 34.6%, P = .04) detection rates than the conventional group. The mean number of proximal polyps and adenomas detected per patient during the first examination was also significantly higher in the CADe group (polyp: 1.20 vs .86, P = .03; adenoma, .91 vs .61, P = .03). Subgroup analysis showed that CADe enhanced proximal adenoma detection in patients with fair bowel preparation, shorter withdrawal time, and endoscopists with lower adenoma detection rate. CONCLUSIONS: This multicenter trial from Asia confirmed that CADe can further enhance proximal adenoma and polyp detection but may not be able to reduce the number of missed proximal colonic lesions. (Clinical trial registration number: NCT04294355.).
Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Estudos Prospectivos , Colonoscopia , Adenoma/diagnóstico , Adenoma/patologia , Computadores , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/patologiaRESUMO
BACKGROUND AND AIMS: Meta-analysis shows that up to 26% of adenomas could be missed during colonoscopy. We investigated whether the use of artificial intelligence (AI)-assisted real-time detection could provide new insights into mechanisms underlying missed lesions during colonoscopy. METHODS: A validated real-time deep-learning AI model for the detection of colonic polyps was first tested in videos of tandem colonoscopy of the proximal colon for missed lesions. The real-time AI model was then prospectively validated in a total colonoscopy in which the endoscopist was blinded to real-time AI findings. Segmental unblinding of the AI findings were provided, and the colonic segment was then re-examined when missed lesions were detected by AI but not the endoscopist. All polyps were removed for histologic examination as the criterion standard. RESULTS: Sixty-five videos of tandem examination of the proximal colon were reviewed by AI. AI detected 79.1% (19/24) of missed proximal adenomas in the video of the first-pass examination. In 52 prospective colonoscopies, real-time AI detection detected at least 1 missed adenoma in 14 patients (26.9%) and increased the total number of adenomas detected by 23.6%. Multivariable analysis showed that a missed adenoma(s) was more likely when there were multiple polyps (adjusted odds ratio, 1.05; 95% confidence interval, 1.02-1.09; P < .0001) or colonoscopy was performed by less-experienced endoscopists (adjusted odds ratio, 1.30; 95% confidence interval, 1.05-1.62; P = .02). CONCLUSIONS: Our findings provide new insights on the prominent role of human factors, including inexperience and distraction, on missed colonic lesions. With the use of real-time AI assistance, up to 80% of missed adenomas could be prevented. (Clinical trial registration number: NCT04227795.).
Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Adenoma/diagnóstico por imagem , Inteligência Artificial , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Humanos , Estudos ProspectivosRESUMO
BACKGROUND AND AIMS: Linked color imaging (LCI) is a newly available image-enhanced endoscopy (IEE) system that emphasizes the red mucosal color. No study has yet compared LCI with other available IEE systems. Our aim was to investigate polyp detection rates using LCI compared with narrow-band imaging (NBI). METHODS: This is a prospective randomized tandem colonoscopy study. Eligible patients who underwent colonoscopy for symptoms or screening/surveillance were randomized in a 1:1 ratio to receive tandem colonoscopy with both colonoscope withdrawals using LCI or NBI. The primary outcome was the polyp detection rate. RESULTS: Two hundred seventy-two patients were randomized (mean age, 62 years; 48.2% male; colonoscopy for symptoms, 72.8%) with 136 in each arm. During the first colonoscopy, the polyp detection rate (71.3% vs 55.9%; P = .008), serrated lesion detection rate (34.6% vs 22.1%; P = .02), and mean number of polyps detected (2.04 vs 1.35; P = .02) were significantly higher in the NBI group than in the LCI group. There was also a trend of higher adenoma detection rate in the NBI group compared with the LCI group (51.5% vs 39.7%, respectively; P = .05). Multivariable analysis confirmed that use of NBI (adjusted odds ratio, 1.99; 95% confidence interval, 1.09-3.68) and withdrawal time >8 minutes (adjusted odds ratio, 5.11; 95% confidence interval, 2.79-9.67) were associated with polyp detection. Overall, 20.5% of polyps and 18.1% of adenomas were missed by the first colonoscopy, but there was no significant difference in the miss rates between the 2 groups. CONCLUSION: NBI was significantly better than LCI for colorectal polyp detection. However, both LCI and NBI missed 20.5% of polyps. (Clinical trial registration number: NCT03336359.).
Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Aumento da Imagem , Imagem de Banda Estreita , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Colo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos ProspectivosRESUMO
We present a terahertz spectroscopic study of polar ferrimagnet FeZnMo_{3}O_{8}. Our main finding is a giant high-temperature optical diode effect, or nonreciprocal directional dichroism, where the transmitted light intensity in one direction is over 100 times lower than intensity transmitted in the opposite direction. The effect takes place in the paramagnetic phase with no long-range magnetic order in the crystal, which contrasts sharply with all existing reports of the terahertz optical diode effect in other magnetoelectric materials, where the long-range magnetic ordering is a necessary prerequisite. In FeZnMo_{3}O_{8}, the effect occurs resonantly with a strong magnetic dipole active transition centered at 1.27 THz and assigned as electron spin resonance between the eigenstates of the single-ion anisotropy Hamiltonian. We propose that the optical diode effect in paramagnetic FeZnMo_{3}O_{8} is driven by single-ion terms in magnetoelectric free energy.
RESUMO
Heparanase is a ß-d-endoglucuronidase that cleaves heparan sulphate, a key component of the ECM and basement membrane. The remodelling of the ECM by heparanase has been proposed to regulate both normal physiological and pathological processes, including wound healing, inflammation, tumour angiogenesis and cell migration. Heparanase is also known to exhibit non-enzymatic functions by regulating cell adhesion, cell signalling and differentiation. In this study, constitutive heparanase-deficient (Hpse(-/-) ) mice were generated on a C57BL/6 background using the Cre/loxP recombination system, with a complete lack of heparanase mRNA, protein and activity. Although heparanase has been implicated in embryogenesis and development, Hpse(-/-) mice are anatomically normal and fertile. Interestingly, consistent with the suggested function of heparanase in cell migration, the trafficking of dendritic cells from the skin to the draining lymph nodes was markedly reduced in Hpse(-/-) mice. Furthermore, the ability of Hpse(-/-) mice to generate an allergic inflammatory response in the airways, a process that requires dendritic cell migration, was also impaired. These findings establish an important role for heparanase in immunity and identify the enzyme as a potential target for regulation of an immune response.
Assuntos
Movimento Celular/imunologia , Células Dendríticas/imunologia , Glucuronidase/imunologia , Pneumonia/imunologia , Animais , Western Blotting , Movimento Celular/genética , Células Cultivadas , Células Dendríticas/metabolismo , Feminino , Citometria de Fluxo , Expressão Gênica/genética , Expressão Gênica/imunologia , Glucuronidase/deficiência , Glucuronidase/genética , Linfonodos/imunologia , Linfonodos/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia de Fluorescência , Pneumonia/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Pele/imunologia , Pele/metabolismoRESUMO
We report on the first terahertz (THz) emitter based on femtosecond-laser-ablated gallium arsenide (GaAs), demonstrating a 65% enhancement in THz emission at high optical power compared to the nonablated device. Counter-intuitively, the ablated device shows significantly lower photocurrent and carrier mobility. We understand this behavior in terms of n-doping, shorter carrier lifetime, and enhanced photoabsorption arising from the ablation process. Our results show that laser ablation allows for efficient and cost-effective optoelectronic THz devices via the manipulation of fundamental properties of materials.
RESUMO
OBJECTIVES: The aim of this study is to quantify the mortality rate, direct healthcare costs, and cumulative life costs of pediatric patients with spinal muscular atrophy (SMA) type 1, type 2, and type 3 born in Hong Kong. METHODS: Data were collected from genetically confirmed SMA patients born in or after 2000 from the Hospital Authority medical database. Patients were followed up from birth until they died, left Hong Kong, reached 18 years, or initiated disease-modifying treatment. Study outcomes included incidence risks of mortality, cumulative direct medical costs-attendances of special outpatient clinics, emergency department, allied health services, and mean length of stay in hospitals over time. Total direct medical costs were calculated as unit costs multiplied by utilization frequencies of corresponding healthcare services at each age. RESULTS: Seventy-one patients with SMA were included. Over a median follow-up period of 6 years, the overall incidence rate of death was 5.422/100 person-years (95%CI 3.542-7.945/100 person-years). 67.7% and 11% of deaths occurred in SMA1 and SMA2 groups, respectively. The median age of death was 0.8 years in SMA1 and 10.9 years in SMA2. The mean cumulative direct medical costs in overall SMA, SMA1, SMA2 and SMA3 groups per patient were US$935,570, US$2,393,250, US$413,165, and US$40,735, respectively. INTERPRETATION: Our results confirmed a significantly raised mortality and extremely high healthcare burden for patients with SMA especially SMA type 1 and 2 without disease-modifying treatment. Study evaluating health and economic impact of newborn screening and early treatment is needed.
Assuntos
Atrofia Muscular Espinal , Atrofias Musculares Espinais da Infância , Recém-Nascido , Criança , Humanos , Lactente , Atenção à Saúde , Custos de Cuidados de Saúde , Serviços de SaúdeRESUMO
BACKGROUND: While statin induces plaque regression, its effects, particularly with different doses on plaque virtual histology composition, remain unknown. METHODS AND RESULTS: In this prospective, randomized, double-blinded study, 40 consecutive statin-naive patients with stable angina requiring percutaneous coronary intervention (PCI) were randomized to 2 arms (20 patients each) receiving 6 months of atorvastatin 10 mg or 40 mg daily. The primary end-point was (VH-IVUS) changes from baseline to 6 months, as assessed by a core laboratory. Fifty-four VH-IVUS lesions were analyzed from the 10 mg group and 57 from the 40 mg group. Overall, plaque volume was reduced by 4.28% (-5.10±14.93 mm(3), P<0.001), absolute VH-IVUS fibrous volume by 10.54% (-4.87±10.74 mm(3), P<0.001), and relative percentage fibrous component by 3.29±7.84% (P<0.001), while relative percentage dense calcium increased by 1.50±3.08% (P<0.001), and necrotic core by 3.19±7.82% (P<0.001). Beneficial changes were more substantial in the higher dose (40 mg) group, with significantly more percentage plaque volume regression (-1.50±3.85% vs. 0.38±4.05% increase in the 10 mg group, P=0.014), less relative percentage necrotic core expansion (1.68±7.57% vs. 4.78±7.82% in the 10 mg group, P=0.037), and without occurrence of major adverse cardiac events (vs. 6 patients in the 10 mg group, P=0.020). CONCLUSIONS: In statin-naive patients requiring PCI, 6 months of atorvastatin induced a significant percentage of plaque volume reduction and substantial modification of VH-IVUS composition. In addition, these effects appeared to vary with different doses of atorvastatin, showing significantly better limitation of relative percentage necrotic core expansion at a higher dose.
Assuntos
Anticolesterolemiantes/administração & dosagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Ácidos Heptanoicos/administração & dosagem , Placa Aterosclerótica/tratamento farmacológico , Placa Aterosclerótica/patologia , Pirróis/administração & dosagem , Idoso , Atorvastatina , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Fatores de TempoRESUMO
OBJECTIVES. To evaluate attainment of low-density lipoprotein cholesterol goals among hypercholesterolaemic patients undergoing lipid-lowering drug treatment in Hong Kong and to identify potential determinants of treatment outcomes. DESIGN. Cross-sectional observational study. SETTING. A single site in Hong Kong, as part of the CEPHEUS Pan-Asian survey. PATIENTS. Subjects with hypercholesterolaemia aged 18 years or above, who had been on lipid-lowering drug treatment for at least 3 months with no dose adjustment for at least 6 weeks. RESULTS. A total of 561 such patients (mean age, 65.3; standard deviation, 9.7 years) were evaluated. Most had major cardiovascular risk factors; 534 (95.2%) of 561 patients had coronary heart disease and 534 (95.4%) of 560 patients had low-density lipoprotein cholesterol goals set at lower than 70 mg/dL. In all, 465 (82.9%) patients attained their respective low-density lipoprotein cholesterol goals. Among 75 patients who had coronary heart disease or equivalent risk, and multiple risk factors with a 10-year coronary heart disease risk of over 20%, 62 (82.7%) attained their respective low-density lipoprotein cholesterol goals. Significant predictors of low-density lipoprotein cholesterol goal attainment included the patient's baseline lipid profile (total cholesterol and low-density lipoprotein cholesterol levels), blood pressure, and drugs (statin/non-statin) used for treatment. CONCLUSIONS. Hypercholesterolaemic patients undergoing lipid-lowering drug treatment in the present Hong Kong study were able to achieve a very high attainment rate for the low-density lipoprotein cholesterol goal, despite the fact that most of them had major cardiovascular risk factors.
Assuntos
Doenças Cardiovasculares/prevenção & controle , LDL-Colesterol/sangue , Hipercolesterolemia/tratamento farmacológico , Hipolipemiantes/uso terapêutico , Adulto , Idoso , Pressão Sanguínea , Doenças Cardiovasculares/etiologia , Colesterol/sangue , Doença das Coronárias/etiologia , Doença das Coronárias/prevenção & controle , Estudos Transversais , Feminino , Hong Kong , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipercolesterolemia/complicações , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do TratamentoRESUMO
With rapidly growing photoconversion efficiencies, hybrid perovskite solar cells have emerged as promising contenders for next generation, low-cost photovoltaic technologies. Yet, the presence of nanoscale defect clusters, that form during the fabrication process, remains critical to overall device operation, including efficiency and long-term stability. To successfully deploy hybrid perovskites, we must understand the nature of the different types of defects, assess their potentially varied roles in device performance, and understand how they respond to passivation strategies. Here, by correlating photoemission and synchrotron-based scanning probe X-ray microscopies, we unveil three different types of defect clusters in state-of-the-art triple cation mixed halide perovskite thin films. Incorporating ultrafast time-resolution into our photoemission measurements, we show that defect clusters originating at grain boundaries are the most detrimental for photocarrier trapping, while lead iodide defect clusters are relatively benign. Hexagonal polytype defect clusters are only mildly detrimental individually, but can have a significant impact overall if abundant in occurrence. We also show that passivating defects with oxygen in the presence of light, a previously used approach to improve efficiency, has a varied impact on the different types of defects. Even with just mild oxygen treatment, the grain boundary defects are completely healed, while the lead iodide defects begin to show signs of chemical alteration. Our findings highlight the need for multi-pronged strategies tailored to selectively address the detrimental impact of the different defect types in hybrid perovskite solar cells.
RESUMO
An exciton, a two-body composite quasiparticle formed of an electron and hole, is a fundamental optical excitation in condensed matter systems. Since its discovery nearly a century ago, a measurement of the excitonic wave function has remained beyond experimental reach. Here, we directly image the excitonic wave function in reciprocal space by measuring the momentum distribution of electrons photoemitted from excitons in monolayer tungsten diselenide. By transforming to real space, we obtain a visual of the distribution of the electron around the hole in an exciton. Further, by also resolving the energy coordinate, we confirm the elusive theoretical prediction that the photoemitted electron exhibits an inverted energy-momentum dispersion relationship reflecting the valence band where the partner hole remains, rather than that of conduction band states of the electron.
RESUMO
BACKGROUND: Haemorrhoidectomy is associated with significant post-operative pain which is primarily managed pharmacologically. Whether a non-pharmacological adjunct such as a checklist can improve pain outcomes after an open haemorrhoidectomy has yet to be studied. The purpose of this study was to determine if a patient-completed checklist of prescribed post-haemorrhoidectomy pain medications would improve pain management after surgery. METHODS: We conducted a dual-centre randomized controlled trial of patients undergoing a Milligan-Morgan haemorrhoidectomy for symptomatic third or fourth degree haemorrhoids. Thirty-five patients were randomized into either a control group which received post-operative pain medication plus a visual analogue scale (VAS) form, or an intervention group which received a post-operative medication checklist in addition to the items the control group received. Both groups recorded their pain levels on the VAS forms at 10.00, 14.00 and 20.00 hours each day for 14 days post-operatively. RESULTS: Patients in the checklist group reported a significantly greater reduction in mean VAS pain score of 2.51 (95% confidence interval (CI) 1.34-3.68; P < 0.001) between day 1 post-op and day 14 post-op compared to 1.86 (95% CI 0.77-2.95; P = 0.001) for the control group. There was no significant difference between mean pain experienced by patients in either group over each of the 14 days individually or overall (P = 0.07). CONCLUSION: The pain medication checklist lead to a greater reduction in pain between day 1 and 14 after an open haemorrhoidectomy compared to standard care but did not significantly reduce mean pain across any individual days or overall.
Assuntos
Hemorroidectomia , Hemorroidas , Lista de Checagem , Hemorroidas/cirurgia , Humanos , Manejo da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controleRESUMO
Resolving momentum degrees of freedom of excitons, which are electron-hole pairs bound by the Coulomb attraction in a photoexcited semiconductor, has remained an elusive goal for decades. In atomically thin semiconductors, such a capability could probe the momentum-forbidden dark excitons, which critically affect proposed opto-electronic technologies but are not directly accessible using optical techniques. Here, we probed the momentum state of excitons in a tungsten diselenide monolayer by photoemitting their constituent electrons and resolving them in time, momentum, and energy. We obtained a direct visual of the momentum-forbidden dark excitons and studied their properties, including their near degeneracy with bright excitons and their formation pathways in the energy-momentum landscape. These dark excitons dominated the excited-state distribution, a surprising finding that highlights their importance in atomically thin semiconductors.