Air displacement plethysmography (ADP) is fast, accurate, and reliable. Nevertheless, in about 3% of the cases, standard ADP tests provide rogue results. To spot these outliers and improve precision, repeated trials protocols have been devised, but few works have addressed their reliability. This study was conducted to evaluate the test-retest reliabilities of two known protocols and a new one, proposed here. Ninety-two healthy adults (46 men and 46 women) completed six consecutive ADP tests. To evaluate the reliability of single measurements, we used the results of the first two tests; for multiple measures protocols, we computed the test result from trials 1-3 and the retest result from trials 4-6. Bland-Altman analysis revealed that the bias and the width of the 95% interval of agreement were smaller for multiple trials than for single ones. For percent body fat (%BF)/fat-free mass, the technical error of measurement was 1% BF/0.68 kg for single trials and 0.62% BF/0.46 kg for the new protocol of multiple trials, which proved to be the most reliable. The minimal detectable change (MDC) was 2.77% BF/1.87 kg for single trials and 1.72% BF/1.26 kg for the new protocol.


Assuntos
Composição Corporal , Pletismografia , Tecido Adiposo , Adulto , Viés , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes