1.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36257545

RESUMO

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Procedimentos Cirúrgicos sem Sutura , Humanos , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Relatório de Pesquisa , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos sem Sutura/efeitos adversos
2.
Echocardiography ; 35(1): 64-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29071795

RESUMO

OBJECTIVES: The aim of this study was to evaluate the hemodynamic performance of a sutureless bioprosthesis under high workload at mid-term follow-up. METHODS: Thirty-two patients who underwent isolated aortic valve replacement with a Perceval sutureless bioprosthesis with a minimum follow-up of 1 year were enrolled in this study. S size prosthesis was deployed in 10 patients (31.3%), M size in 9 (28.1%), L size in 8 (25%) and XL size in 5 (15.6%). Effective orifice area (EOA), EOA index (EOAi), and transvalvular gradients were assessed at rest and during dobutamine stress echocardiography (DSE) a median of 19.5 months after surgery. RESULTS: Dobutamine stress echocardiography (DSE) significantly increased heart rate, stroke volume, ejection fraction, and transvalvular gradients (peak gradient, 24.0 ± 7.6 vs 38.7 ± 13.6 mm Hg, P < .001; mean gradient, 12.6 ± 4.2 vs 19.8 ± 8.3, P < .001). When compared to baseline, estimated valve areas significantly increased at follow-up (EOA, 1.48 ± 0.46 vs 2.06 ± 0.67, P < .001; EOAi, 0.84 ± 0.26 vs 1.17 ± 0.37, P < .001). Mean percentage increase in EOAi was 40.3% ± 28.0%. S size prostheses had the highest increase in EOA1, but the difference was not significant (S 46.0% ± 27.5% vs M 45.4% ± 34.5% vs L 32.7% ± 26.4% vs XL 32.1% ± 20.5%, P = .66). Severe patient-prosthesis mismatch (EOAi ≤ 0.65 cm2 /m2 ) was present at rest in 8 patients (25%), but only in one patient (3.1%) during DSE. CONCLUSIONS: The Perceval sutureless bioprosthesis demonstrated good hemodynamics at rest and under high workload. The significant increase in EOAi during DSE suggests the potential advantages of Perceval sutureless bioprostheses in case of small aortic annulus or when patient-prosthesis mismatch is anticipated.


Assuntos
Bioprótese , Ecocardiografia sob Estresse/métodos , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Procedimentos Cirúrgicos sem Sutura/métodos , Idoso , Feminino , Seguimentos , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia
3.
Transfusion ; 57(1): 178-186, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27774615

RESUMO

BACKGROUND: Excessive bleeding and blood transfusion are associated with adverse outcome after cardiac surgery, but their mechanistic effects are difficult to disentangle in patients with increased operative risk. This study aimed to evaluate the incidence and prognostic impact of bleeding and transfusion of blood products in low-risk patients undergoing coronary artery bypass grafting (CABG). STUDY DESIGN AND METHODS: Sixteen tertiary European centers of cardiac surgery contributed to the prospective European registry of CABG (E-CABG). The severity of bleeding was defined by the E-CABG bleeding severity classification and universal definition of perioperative bleeding (UDPB) classification. RESULTS: Of 1213 patients with EuroSCORE II of less than 2% (mean, 1.1 ± 0.4%), 18.5% suffered from mild bleeding (E-CABG bleeding Grade 1) and 3.4% experienced severe bleeding (E-CABG bleeding Grade 2-3). Similarly, 19.7% had UDPB Class 2 and 5.9% had UDPB Classes 3 and 4. Mild and severe bleeding defined by the E-CABG and UDPB classifications were associated with an increased risk of several adverse events as adjusted by multiple covariates. The risk of death, stroke, and acute kidney injury was particularly increased in patients with severe bleeding. CONCLUSION: Severe bleeding is rather uncommon in low-risk patients undergoing CABG, but it is associated with an increased risk of major adverse events. Prevention of excessive perioperative bleeding and patient blood management may improve the outcome of cardiac surgery also in low-risk patients.


Assuntos
Transfusão de Sangue , Ponte de Artéria Coronária/efeitos adversos , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/terapia , Sistema de Registros , Idoso , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/diagnóstico , Prognóstico , Estudos Prospectivos , Fatores de Risco , Centros de Atenção Terciária
4.
Heart Vessels ; 31(3): 427-33, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25573258

RESUMO

The aim of this study was to compare the immediate outcome of patients undergoing transcatheter (TAVI) versus surgical aortic valve replacement with the sutureless Perceval bioprosthesis (SU-AVR). This is a retrospective multicenter analysis of 773 patients who underwent either TAVI (394 patients, mean age, 80.8 ± 5.5 years, mean EuroSCORE II 5.6 ± 4.9 %) or SU-AVR (379 patients, 77.4 ± 5.4 years, mean EuroSCORE II 4.0 ± 3.9 %) with or without concomitant myocardial revascularization. Data on SU-AVRs were provided by six European institutions (Belgium, Finland, Germany, Italy and Sweden) and data on TAVIs were provided by a single institution (Catania, Italy). In-hospital mortality was 2.6 % after SU-AVR and 5.3 % after TAVI (p = 0.057). TAVI was associated with a significantly high rate of mild (44.0 vs. 2.1 %) and moderate-severe paravalvular regurgitation (14.1 vs. 0.3 %, p < 0.0001) as well as the need for permanent pacemaker implantation (17.3 vs. 9.8 %, p = 0.003) compared with SU-AVR. The analysis of patients within the 25th and 75th percentiles interval of EuroSCORE II, i.e., 2.1-5.8 %, confirmed the findings of the overall series. One-to-one propensity score-matched analysis resulted in 144 pairs with similar baseline characteristics and operative risk. Among these matched pairs, in-hospital mortality (6.9 vs. 1.4 %, p = 0.035) was significantly higher after TAVI. SU-AVR with the Perceval prosthesis in intermediate-risk patients is associated with excellent immediate survival and is a valid alternative to TAVI in these patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos sem Sutura , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Pontuação de Propensão , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/mortalidade , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiothorac Vasc Anesth ; 30(2): 330-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26708697

RESUMO

OBJECTIVE: The authors aimed to validate the European Multicenter Study on Coronary Artery Bypass Grafting (E-CABG) classification of postoperative complications in patients undergoing coronary artery bypass grafting (CABG). DESIGN: Retrospective, observational study. SETTING: University hospital. PARTICIPANTS: A total of 2,764 patients with severe coronary artery disease. Complete baseline, operative, and postoperative data were available for patients who underwent isolated CABG. INTERVENTIONS: Isolated CABG. MEASUREMENTS AND MAIN RESULTS: The E-CABG complication classification was used to stratify the severity and prognostic impact of adverse postoperative events. Primary outcome endpoints were 30-day, 90-day, and long-term all-cause mortality. The secondary outcome endpoints was the length of intensive care unit stay. Both the E-CABG complication grades and additive score were predictive of 30-day (area under the receiver operating characteristics curve 0.866, 95% confidence interval [CI] 0.829-0.903; and 0.876; 95% CI 0.844-0.908, respectively) and 90-day (area under the receiver operating characteristics curve 0.850, 95% CI 0.812-0.887; and 0.863, 95% CI 0.829-0.897, respectively) all-cause mortality. The complication grades were independent predictors of increased mortality at actuarial (log-rank: p<0.0001) and adjusted analysis (p<0.0001; grade 1: hazard ratio [HR] 1.757, 95% CI 1.111-2.778; grade 2: HR 2.704, 95% CI 1.664-4.394; grade 3: HR 5.081, 95% CI 3.148-8.201). When patients who died within 30 days were excluded from the analysis, this grading method still was associated with late mortality (p<0.0001). The grading method (p<0.0001) and the additive score (rho, 0.514; p<0.0001) were predictive of the length of intensive care unit stay. CONCLUSIONS: The E-CABG postoperative complication classification seems to be a promising tool for stratifying the severity and prognostic impact of postoperative complications in patients undergoing cardiac surgery.


Assuntos
Algoritmos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Vasos Coronários/cirurgia , Complicações Pós-Operatórias/classificação , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos
6.
J Cardiothorac Vasc Anesth ; 29(2): 275-82, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25791689

RESUMO

OBJECTIVES: The aim of this study was to evaluate the immediate and late outcome of emergency coronary artery bypass grafting (CABG) in a multicenter setting. DESIGN: Multicenter, retrospective study. SETTING: Four university hospitals. PARTICIPANTS: 596 patients were included in this study. INTERVENTIONS: Included patients underwent isolated, emergency CABG. MEASUREMENTS AND MAIN RESULTS: Sixty patients (absolute rate: 10.1%, pooled rate: 8.7%) died during the in-hospital stay period. Increasing emergency CABG classes (p<0.0001), recent myocardial infarction (p=0.019), left ventricular ejection fraction≤30% (p=0.034), on-pump surgery (p=0.012), and participating centers (p<0.0001) were independent predictors of in-hospital mortality. Survival rates at 1, 3, and 5 years were 86.4%, 81.6%, and 76.1%, respectively. Extracorporeal membrane oxygenation was used in 6 patients and 3 of them (50.0%) survived the immediate postoperative period. Patient populations of participating centers differed significantly in most of baseline characteristics. The preoperative use of intra-aortic balloon pump (8% to 51%) and off-pump surgery (2.8% to 56.3%) varied significantly between institutions. In-hospital mortality (2.8%, 5.9%, 7.7% and 19.8%, p<0.0001), as well as midterm survival, significantly differed between institutions (at 3 years, 90.6%, 89.8%, 81.2%, and 67.2%, p<0.0001). CONCLUSIONS: The outcome after emergency CABG is satisfactory despite a significant operative risk. However, the results of emergency CABG significantly differed between the participating institutions, likely due to differences in the referral pathways and perioperative treatment strategies. Evaluation of these factors is crucial for implementation of treatment in centers with suboptimal results.


Assuntos
Ponte de Artéria Coronária/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea/estatística & dados numéricos , Feminino , Finlândia/epidemiologia , Mortalidade Hospitalar , Humanos , Balão Intra-Aórtico/estatística & dados numéricos , Itália/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Retrospectivos , Taxa de Sobrevida
7.
Minerva Cardiol Angiol ; 71(3): 311-320, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36305774

RESUMO

BACKGROUND: The safety of concomitant percutaneous coronary intervention (PCI) during transcatheter aortic valve implantation (TAVI) setting is still highly debated. This study aimed to assess the safety and the effectiveness of TAVI and PCI performed in the same session compared with TAVI alone. METHODS: Patients with severe aortic stenosis and coronary artery disease (CAD) (N.=786) who underwent TAVI from June 2007 to April 2021 were divided into two groups: patients who underwent TAVI alone (N.=633) and patients treated with TAVI and concomitant PCI (N.=153). The propensity-score matching adjustment was used to account for baseline confounding variables. RESULTS: A total of 302 TAVI with CAD patients (151 matched pairs), undergoing either isolated TAVI or TAVI+PCI were compared. In-hospital death (6% vs. 4%; P=0.427), stroke (2% vs. 0.7%; P=0.314), myocardial infarction (MI) (0% vs. 0.7%; P=0.317), major and life-threatening bleeding (14.6% vs. 15.9%; P=0.749), and acute kidney injury (9.3% vs. 10.6%; P=0.700) were similar for both groups. At 3 years, the rates of all-cause death (25.2% vs. 19.2%; P=0.615), the composite endpoints of all-cause death and MI (27.2% vs. 21.2%; P=0.699) and all-cause death, MI, and stroke (28.5% vs. 22.5%; P=0.739) were also comparable between the two groups. Achieving complete coronary revascularization in the TAVI setting did not impact on long-term mortality (P=0.257). CONCLUSIONS: In patients with severe aortic stenosis and CAD, concomitant TAVI and PCI was as safe and effective as TAVI alone up to 3-year follow-up.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Mortalidade Hospitalar , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Acidente Vascular Cerebral/complicações
8.
J Clin Med ; 11(12)2022 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-35743475

RESUMO

BACKGROUND: Hypertrophic obstructive cardiomyopathy (HOCM) is a heterogeneous disease with different clinical presentations, albeit producing similar dismal long-term outcomes if left untreated. Several approaches are available for the treatment of HOCM; e.g., alcohol septal ablation (ASA) and surgical myectomy (SM). The objectives of the current review were to (1) discuss the place of the standard invasive treatment modalities (ASA and SM) for HOCM; (2) summarize and compare novel techniques for the management of HOCM; (3) analyze current guidelines addressing HOCM management; and (4) offer suggestions for the treatment of complex HOCM presentations. METHODS: We searched the literature and attempted to gather the most relevant and impactful available evidence on ASA, SM, and other invasive means of treatment of HOCM. The literature search yielded thousands of results, and 103 significant publications were ultimately included. RESULTS: We critically analyzed available guidelines and provided context in the setting of patient selection for standard and novel treatment modalities. This review offers the most comprehensive analysis to-date of available invasive treatments for HOCM. These include the standard treatments, SM and ASA, as well as novel treatments such as dual-chamber pacing and radiofrequency catheter ablation. We also account for complex pathoanatomic presentations and current guidelines to offer suggestions for tailored care of patients with HOCM. Finally, we consider promising future therapies for HOCM. CONCLUSIONS: HOCM is a heterogeneous disease associated with poor outcomes if left untreated. Several strategies for treatment of HOCM are available but patient selection for the procedure is crucial.

9.
G Ital Cardiol (Rome) ; 23(6): 461-468, 2022 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-35674037

RESUMO

BACKGROUND: To assess the longitudinal changes in transcatheter aortic valve implantation (TAVI) practice and patients' outcomes in a high-volume Italian center. METHODS: We analyzed all patients undergoing TAVI at our Institution from June 2007 to August 2021. We stratified the overall population considering four time periods according to procedural advancements and changes in clinical practice: period 1 (2007-2009, n=107) vs period 2 (2010-2014, n=449) vs period 3 (2015-2019, n=864) vs period 4 (2019-2021, n=638). Baseline and procedural characteristics, and in-hospital outcomes among the four groups were compared. RESULTS: A total of 2058 patients underwent TAVI receiving all the available devices. Patients had a median age of 82 years (78-85) with no differences among time periods. A stepwise reduction of median Society of Thoracic Surgeons mortality risk score (3.7 [2.8-5.3] vs 3.6 [2.6-5.4] vs 3.6 [2.5-5.5] vs 3.3 [2.2-4.9]; p=0.01) was observed. In-hospital all-cause-death (7.5% vs 5.1% vs 2.9% vs 3.0%; p<0.05), major stroke (4.7% vs 0.7% vs 1.0% vs 0.8%; p<0.05), major vascular complications (17.8% vs 8.7% vs 10.5% vs 5.8%; p<0.05) and permanent pacemaker implantation (23.4% vs 12.0% vs 8.7% vs 8.8%; p<0.05) rates significantly lowered over time. Device success markedly improved (80.4% vs 87.1% vs 95.0% vs 96.3%; p<0.05) with significant improvement of paravalvular regurgitation after TAVI (moderate-to-severe 16.8% vs 8.1% vs 0.7% vs 0.2%; mild 61.4% vs 38.2% vs 38.5% vs 25.6%; p<0.05). CONCLUSIONS: All-cause death and in-hospital outcomes of patients undergoing TAVI significantly improved accordingly to technical advancements and changes in clinical practice over 15-year experience.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
Ann Thorac Surg ; 114(3): 758-765, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34563505

RESUMO

BACKGROUND: This study compared clinical and hemodynamic in-hospital outcomes of patients undergoing sutureless vs rapid deployment aortic valve replacement (SURD-AVR) in the large population of the Sutureless and Rapid Deployment International Registry (SURD-IR). METHODS: We examined 4695 patients who underwent isolated or combined SURD-AVR. The "sutureless" Perceval valve (LivaNova PLC, London, United Kingdom) was used in 3133 patients and the "rapid deployment" Intuity (Edwards Lifesciences, Irvine, CA) in 1562. Potential confounding factors were addressed by the use of propensity score matching. After matching, 2 well-balanced cohorts of 823 pairs (isolated SURD-AVR) and 467 pairs (combined SURD-AVR) were created. RESULTS: Patients who received Perceval and Intuity valves showed similar in-hospital mortality and rate of major postoperative complications. Perceval was associated shorter cross-clamp and cardiopulmonary bypass times. In the isolated SURD-AVR group, patients receiving Perceval were more likely to undergo anterior right thoracotomy incision. Postoperative transvalvular gradients were significantly lower for the Intuity valve compared with those of the Perceval valve, either in isolated and combined SURD-AVR. The Intuity valve was associated with a lower rate of postoperative mild aortic regurgitation. CONCLUSIONS: Our results confirm the safety and efficacy of SURD-AVR regardless of the valve type. The Perceval valve was associated with reduced operative times and increased anterior right thoracotomy incision. The Intuity valve showed superior hemodynamic outcomes and a lower incidence of postoperative mild aortic regurgitation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35775935

RESUMO

OBJECTIVES: To compare procedural and in-hospital outcomes of patients undergoing sutureless (Perceval, Livanova PLC, London, UK) and rapid deployment (Intuity Elite, Edwards Lifesciences, Irvine, CA, USA) aortic valve replacement (group 1) versus sutured aortic valve replacement (group 2). METHODS: Patients receiving isolated aortic valve replacement between 2014 and 2020 were analysed using data from the Sutureless and Rapid Deployment International Registry. Patients in group 1 and group 2 were propensity-score matched in a 1:1 ratio. RESULTS: A total of 7708 patients were included in the study. After matching, 2 groups of 2643 each were created. Patients in group 1 were more likely to undergo minimally invasive approaches and were associated with shorter operative times when compared with group 2. Overall in-hospital mortality was similar between groups. While an increased risk of stroke was observed in group 1 in the first study period (2014-2016; relative risk 3.76, P < 0.001), no difference was found in more recent year period (relative risk 1.66, P = 0.08; P for heterogeneity 0.003). Group 1 was associated with reduced rates of postoperative low cardiac output syndrome, atrial fibrillation and mild aortic regurgitation. New pacemaker implant was three-fold higher in group 1. CONCLUSIONS: Our findings showed significant differences in procedural and clinical outcomes between the study groups. These results suggest that sutureless and rapid deployment aortic valve replacement should be considered as part of a comprehensive valve programme. The knowledge of the respective post-aortic valve replacement benefits for different valve technologies may result in patient-tailored valve selection with improved clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
12.
Semin Thorac Cardiovasc Surg ; 34(2): 453-461, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33979664

RESUMO

Aim of this retrospective, multicenter study was to evaluate early and mid-term clinical and hemodynamic results of patients who underwent surgical aortic valve replacement (SAVR) with Intuity rapid-deployment bioprostheses (RDB) (Edwards Lifesciences, Irvine, CA). We analyzed data from the Italian Registry of Intuity Valve (INTU-ITA registry) that is a national, real-world and independent from the industry registry. Preoperative variables were defined according to EuroSCORE and postoperative outcomes according to Valve Academic Research Consortium (VARC). Survival distribution was evaluated using the Kaplan-Meier approach. A Cox-Proportional Hazard Model was employed to assess the effect of the covariates on patients' survival. The registry included 1687 patients from 23 centers (June 2012-September 2019). Aortic cross clamp time for isolated SAVR was 55 minutes (IQR: 45-70 minute). Postoperative pace-maker rate was 6.3%. At discharge transaortic peak and mean gradients were: 18 mm Hg (IQR: 14-23 mm Hg) and 10 mmHg (IQR: 8-13 mm Hg), respectively. Indexed effective orifice area was 1.10 cm2/m2 (IQR: 0.91-1.31 cm2/m2) and the incidence of severe patient-prosthesis mismatch was 0.6%. Hemodynamic data for all valve sizes remained stable during follow-up. Thirty-day overall mortality was 1.8% (30 patients), and at follow-up it was 5.3% (89 patients). Kaplan-Meier overall survival was 95.5% (94.3-96.7%); 90.7% (88.3-93.1%); 86.4% (82.6-90.4%) at 1, 3, and 5 years, respectively. Serum creatinine (HR: 1.36; 95%CI: 1.04-1.81; p = 0.0397) and cross-clamp time (HR: 1.01; 95%CI: 1.002-1.017; p = 0.0077) were identified as independent predictors of mortality. According to our data from the INTU-ITA registry, SAVR with RDB provides good early clinical and hemodynamic results that are confirmed at follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
13.
Ann Thorac Surg ; 111(6): 1916-1922, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33039363

RESUMO

BACKGROUND: The aim of this multicenter retrospective study was to compare early and midterm clinical and hemodynamic results of aortic valve replacement with rapid-deployment bioprostheses performed through conventional full-sternotomy vs mini-sternotomy. METHODS: Data from the Italian multicenter registry of aortic valve replacement with rapid-deployment bioprostheses (INTU-ITA registry) were analyzed. Patients were divided into 2 groups: full sternotomy (FS) and ministernotomy (MS). Primary endpoint was the comparison of early and midterm mortality. Secondary endpoints were: comparison of intraoperative variables, complications, and hemodynamic performance. A propensity score weighting approach was used for data analysis. RESULTS: A total of 1057 patients were analyzed: 435 (41.2%) and 622 (58.8%) in group FS and MS, respectively. Thirty-day mortality was 1.6% and 0.6% in FS and MS groups, respectively (P = .074). cardiopulmonary bypass time was 78.5 minutes and 83 minutes in FS and MS groups, respectively (P = .414). In the overall cohort, the incidence of intraoperative complications and of device success was 3.8% (40 patients) and 95.9% (1014 patients), respectively, with no significant differences between groups. Survival at 1, 3, and 5 years was 94.1%, 98.1%, 88.5% and 91.8%, 85.2%, and 84.8% in FS and MS groups, respectively (P = .412). The 2 groups showed similar postoperative gradients (median mean gradient, FS: 10.0 mm Hg, MS: 11.0 mm Hg; P = .170) and also similar incidence of patient-prosthesis mismatch (FS: 7%, MS: 6.4%, P = .647). CONCLUSIONS: According to our data, rapid-deployment bioprostheses allow the performance of minimally invasive aortic valve replacement with similar surgical times and similar clinical and hemodynamic outcomes to conventional surgery and should be considered the first choice in these procedures.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Esternotomia/métodos , Idoso , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Itália , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Duração da Cirurgia , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Esternotomia/efeitos adversos , Taxa de Sobrevida , Resultado do Tratamento
14.
G Ital Cardiol (Rome) ; 21(3): 209-215, 2020 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-32100733

RESUMO

BACKGROUND: To evaluate the long-term clinical and echocardiographic performance of mitral valve repair with the edge-to-edge technique. METHODS: In-hospital results, actuarial freedom from all-cause mortality, cumulative incidence of cardiovascular mortality, recurrent mitral regurgitation ≥3+ and reoperation on the mitral valve were assessed in 180 consecutive patients undergoing mitral repair with the edge-to-edge technique for degenerative or functional regurgitation. Exercise echocardiography was performed in 24 patients to assess valve hemodynamics in the long-term follow-up. RESULTS: The edge-to-edge repair was applied as a first strategy in 157 patients (87.2%) or as a bail-out procedure in 23 patients (12.8%). At discharge, mitral regurgitation grade was absent in 152 patients (84.4%) and trivial in 28 patients (15.6%). Mean gradient was 2.8 ± 0.6 mmHg and effective orifice area was 2.9 ± 0.4 cm2. After a median follow-up of 6.5 (interquartile range 3.5-10.2) years, 93.6% patients were in NYHA functional class I-II. Actuarial survival at 15 years was 89.2 ± 2.7%, whereas the cumulative incidence of cardiovascular mortality was 7.0%, of recurrent mitral regurgitation ≥3+ 12.6% and of reoperation on the mitral valve 3.2%. Exercise stress echocardiography revealed a significant increase of functional area (3.1 ± 0.3 vs 4.0 ± 0.6 cm2, p<0.001) and mean gradients (2.7 ± 0.4 vs 4.6 ± 1.2 mmHg, p<0.001). CONCLUSIONS: The edge-to-edge technique effectively corrects degenerative and functional mitral regurgitation and represents a valid bail-out procedure in case other approaches failed to achieve adequate intraoperative valve competence. Long-term results are sustained up to 15 years, with significant improvement in functional status. Despite an altered geometry, the occurrence of iatrogenic mitral stenosis is avoided even at high workload conditions.


Assuntos
Ecocardiografia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Terapia de Salvação/métodos , Fatores de Tempo
15.
Interact Cardiovasc Thorac Surg ; 31(1): 9-15, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32442254

RESUMO

OBJECTIVES: This study aims to investigate the incidence and determinants of major early adverse events in low-risk patients undergoing isolated coronary artery bypass grafting (CABG). METHODS: The multicentre E-CABG registry included 7352 consecutive patients who underwent isolated CABG from January 2015 to December 2016. Patients with an European System for Cardiac Operative Risk Evaluation (EuroSCORE) II of <2% and without any major comorbidity were the subjects of the present analysis. RESULTS: Out of 2397 low-risk patients, 11 (0.46%) died during the index hospitalization or within 30 days from surgery. Five deaths were cardiac related, 4 of which were secondary to technical failures. We estimated that 8 out of 11 deaths were potentially preventable. Logistic regression model identified porcelain aorta [odds ratio (OR) 34.3, 95% confidence interval (CI) 1.3-346.3] and E-CABG bleeding grades 2-3 (OR 30.2, 95% CI 8.3-112.9) as independent predictors of hospital death. CONCLUSIONS: Mortality and major complications, although infrequently, do occur even in low-risk patients undergoing CABG. Identification of modifiable causes of postoperative adverse events may be useful to develop preventative strategies to improve the quality of care of patients undergoing cardiac surgery. CLINICAL TRIAL REGISTRATION: NCT02319083 (https://clinicaltrials.gov/ct2/show/NCT02319083).


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco , Idoso , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento
16.
Eur J Cardiothorac Surg ; 58(5): 1054-1062, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32356876

RESUMO

OBJECTIVES: Current evidence on sutureless and rapid deployment aortic valve replacement (SURD-AVR) is limited and does not allow for the assessment of the clinical impact and the evolution of procedural and clinical outcomes of this new valve technology. The Sutureless and Rapid Deployment International Registry (SURD-IR) represents a unique opportunity to evaluate the current trends and outcomes of SURD-AVR interventions. METHODS: Data from 3682 patients enrolled between 2007 and 2018 were analysed. Patients were divided according to the date of surgery into 6 equal groups and by the type of intervention: isolated SURD-AVR (n = 2472) and combined SURD-AVR (n = 1086). RESULTS: Across the 11-year study period, significant changes occurred in patient characteristics including a decrease in age and in estimated surgical risk. Less invasive approaches for isolated SURD-AVR increased considerably from 49.4% to 85.5%. The overall in-hospital mortality rate was 1.6% and 3.9% in isolated and combined procedures, respectively, with no change over time. The rate of perioperative stroke decreased significantly (from 4% to 0.5%), as did the rates of postoperative pacemaker implantation (from 12.8% to 5.9%) and aortic regurgitation (from 17.8% to 2.7%). CONCLUSIONS: The present study provides a comprehensive analysis of the current trends and results of SURD-AVR interventions. The most notable changes over time were the increasing implantation of SURD valves in a younger population, with more frequent utilization of less invasive techniques. SURD-AVR demonstrated remarkable improvements in clinical outcomes with a significant reduction in the rates of stroke, pacemaker implantation and postoperative aortic regurgitation.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 58(5): 1063-1071, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32588056

RESUMO

OBJECTIVES: Minimally invasive surgical techniques with optimal outcomes are of paramount importance. Sutureless and rapid deployment aortic valves are increasingly implanted via minimally invasive approaches. We aimed to analyse the procedural outcomes of a full sternotomy (FS) compared with those of minimally invasive cardiac surgery (MICS) and further assess MICS, namely ministernotomy (MS) and anterior right thoracotomy (ART). METHODS: We selected all isolated aortic valve replacements in the Sutureless and Rapid Deployment Aortic Valve Replacement International Registry (SURD-IR, n = 2257) and performed propensity score matching to compare aortic valve replacement through FS or MICS (n = 508/group) as well as through MS and ART accesses (n = 569/group). RESULTS: Postoperative mortality was 1.6% in FS and MICS patients who had a mean logistic EuroSCORE of 11%. Cross-clamp and cardiopulmonary bypass (CPB) times were shorter in the FS group than in the MICS group (mean difference 3.2 and 9.2 min; P < 0.001). Patients undergoing FS had a higher rate of acute kidney injury (5.6% vs 2.8%; P = 0.012). Direct comparison of MS and ART revealed longer mean cross-clamp and CPB times (12 and 16.7 min) in the ART group (P < 0.001). The postoperative outcome revealed a higher stroke rate (3.2% vs 1.2%; P = 0.043) as well as a longer postoperative intensive care unit [2 (1-3) vs 1 (1-3) days; P = 0.009] and hospital stay [11 (8-16) vs 8 (7-12) days; P < 0.001] in the MS group than in the ART group. CONCLUSIONS: According to this non-randomized international registry, FS resulted in a higher rate of acute kidney injury. The ART access showed a lower stroke rate than MS and a shorter hospital stay than all other accesses. All these findings may be related to underlying patient risk factors.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos , Resultado do Tratamento
18.
Ann Thorac Surg ; 110(2): 553-557, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31954690

RESUMO

BACKGROUND: Reoperation for aortic valve replacement can be challenging and is usually associated with an increased risk for complications and mortality. The study aim was to report the results of a multicenter cohort of patients who underwent minimally invasive reoperative aortic valve replacement with a sutureless or rapid-deployment prosthesis. METHODS: From 2007 to 2018 data from 3651 patients were retrospectively collected from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry. Of them, 63 patients who had previously undergone cardiac surgery represented the study population. In-hospital clinical and echocardiographic outcomes were recorded. RESULTS: Mean age of the selected 63 patients was 75.3 ± 7.8 years and logistic EuroSCORE 10.1. Surgery was performed by ministernotomy in 43 patients (68.3%) and by anterior right thoracotomy in 20 (31.7%); 31 patients (49.2%) received the Perceval valve (Livanova PLC, London, UK) and 32 (50.8%) the Intuity valve (Edwards Lifesciences, Irvine, CA). Mean cross-clamp time was 57.8 ± 23.2 minutes and cardiopulmonary bypass time 95.0 ± 34.3 minutes. Neither conversion to full sternotomy nor in-hospital deaths occurred. Postoperative events were ischemic cerebral events in 3 patients (4.8%), need for pacemaker implantation in 2 (3.6%), bleeding requiring reoperation in 5 (8.9%), and dialysis in 1 (1.6%). Median intensive care unit stay was 1 day, and median length of hospital stay was 10 days. On echocardiographic evaluation 1 patient showed a significant postoperative aortic regurgitation. CONCLUSIONS: Minimally invasive reoperative aortic valve replacement with a sutureless or rapid-deployment prosthesis is a safe and feasible treatment strategy, resulting in fast recovery and improved postoperative outcome with no mortality and an acceptable complication rate.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Estenose da Valva Aórtica/diagnóstico , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Ann Cardiothorac Surg ; 9(4): 298-304, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32832411

RESUMO

BACKGROUND: Benefits of sutureless and rapid deployment (SURD) bioprostheses in bicuspid aortic valves (BAV) are controversial. The aim of this study is to report the outcomes of patients undergoing aortic valve replacement (AVR) for BAV from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURD-IR). METHODS: Of the 4,636 patients who received primary isolated SURD-AVR between 2007 and 2018, 191 (4.1%) BAV patients underwent AVR with SURD valve. RESULTS: Overall 30-day mortality was 1.6%. The Intuity valve was implanted in 53.9% of cases, whereas the Perceval was implanted in 46.1%. Rate of stroke for isolated AVR was 4.2%. No case of endocarditis, thromboembolism, myocardial infarction, valve dislocation or structural valve deterioration was reported in the early phase. Rate of pacemaker implantation and moderate-severe aortic regurgitation (AR) were 7.9% and 3.7%, respectively. CONCLUSIONS: BAV is not considered a contraindication for the implantation of SURD valves. However, detailed information of aortic root geometry as well as the knowledge of some technical considerations are mandatory for a good outcome.

20.
J Thorac Cardiovasc Surg ; 159(2): 432-442.e1, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31213376

RESUMO

OBJECTIVES: The aim of this retrospective multicenter study was to compare early clinical and hemodynamic outcomes of Perceval-S sutureless (Livanova, London, United Kingdom) and Intuity rapid-deployment (Edwards Lifesciences, Irvine, Calif) bioprostheses. METHODS: Data from patients who underwent isolated or combined aortic valve replacement with Perceval-S and with Intuity bioprostheses at 18 cardiac surgical institutions were analyzed. Propensity matching was performed to identify similar patient cohorts. RESULTS: We included 911 patients from March 2011 until May 2017. Perceval-S and Intuity valves were implanted in 349 (38.3%) and in 562 (61.7%) patients, respectively. Propensity score identified 117 matched pairs. In the matched cohort, device success was 99.1% and 100% in Perceval-S and Intuity group, respectively (P = 1.000). Thirty-day Valve Academic Research Consortium mortality occurred in 2 (1.7%) and 4 (3.4%) patients in the Perceval-S and in Intuity group, respectively (P = .6834). The rate of postoperative new permanent pacemaker implantation was 6% (7 patients) and 6.8% (8 patients) in the Perceval-S and in Intuity group, respectively (P = .7896). Perceval-S valve implantation requires significantly shorter aortic crossclamp and cardiopulmonary bypass times than Intuity valve implantation (aortic crossclamp time for isolated, 52 ± 14 minutes vs 62 ± 24 minutes; P < .0001). Peak transaortic gradients were 22.4 ± 8.1 mm Hg and 19.6 ± 6.7 mm Hg (P = .0144), whereas mean gradients were 11.8 ± 4.7 mm Hg and 10.5 ± 3.9 mm Hg (P = .0388) in the Perceval-S and Intuity groups, respectively. CONCLUSIONS: Sutureless Perceval-S and rapid-deployment Intuity bioprostheses provide good and similar early clinical and hemodynamic outcomes. Perceval-S valve implantation requires shorter crossclamp and cardiopulmonary bypass times, whereas Intuity valve implantation provides lower transaortic peak and mean gradients.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Estudos Retrospectivos , Procedimentos Cirúrgicos sem Sutura/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA