RESUMO
We report on LinoSPAD2, a single-photon camera system, comprising a 512×1 single-photon avalanche diode (SPAD) front-end and one or two FPGA-based back-ends. Digital signals generated by the SPADs are processed by the FPGA in real time, whereas the FPGA offers full reconfigurability at a very high level of granularity both in time and space domains. The LinoSPAD2 camera system can process 512 SPADs simultaneously through 256 channels, duplicated on each FPGA-based back-end, with a bank of 64 time-to-digital converters (TDCs) operating at 133 MSa/s, whereas each TDC has a time resolution of 20 ps (LSB). To the best of our knowledge, LinoSPAD2 is the first fully reconfigurable SPAD camera system of large format. The SPAD front-end features a pitch of 26.2 µm, a native fill factor of 25.1%, and a microlens array achieving 2.3× concentration factor. At room temperature, the median dark count rate (DCR) is 80 cps at 7 V excess bias, the peak photon detection probability (PDP) is 53% at 520 nm wavelength, and the single-photon timing resolution (SPTR) is 50 ps FWHM. The instrument response function (IRF) is around 100 ps FWHM at system level. The LinoSPAD2 camera system is suitable for numerous applications, including LiDAR imaging, heralded spectroscopy, compressive Raman sensing, and other computational imaging techniques.
RESUMO
The overall sensitivity of frontside-illuminated, silicon single-photon avalanche diode (SPAD) arrays has often suffered from fill factor limitations. The fill factor loss can however be recovered by employing microlenses, whereby the challenges specific to SPAD arrays are represented by large pixel pitch (> 10â µm), low native fill factor (as low as â¼10%), and large size (up to 10 mm). In this work we report on the implementation of refractive microlenses by means of photoresist masters, used to fabricate molds for imprints of UV curable hybrid polymers deposited on SPAD arrays. Replications were successfully carried out for the first time, to the best of our knowledge, at wafer reticle level on different designs in the same technology and on single large SPAD arrays with very thin residual layers (â¼10â µm), as needed for better efficiency at higher numerical aperture (NA > 0.25). In general, concentration factors within 15-20% of the simulation results were obtained for the smaller arrays (32×32 and 512×1), achieving for example an effective fill factor of 75.6-83.2% for a 28.5â µm pixel pitch with a native fill factor of 28%. A concentration factor up to 4.2 was measured on large 512×512 arrays with a pixel pitch of 16.38â µm and a native fill factor of 10.5%, whereas improved simulation tools could give a better estimate of the actual concentration factor. Spectral measurements were also carried out, resulting in good and uniform transmission in the visible and NIR.