Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Phys Rev Lett ; 129(2): 021801, 2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35867467

RESUMO

We report the first results of a search for leptophobic dark matter (DM) from the Coherent-CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9×10^{20} protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM's first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m_{V_{B}}/m_{χ}=2.1, DM masses within the range 9 MeV≲m_{χ}≲50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

2.
Phys Rev Lett ; 121(22): 221801, 2018 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-30547637

RESUMO

The MiniBooNE experiment at Fermilab reports results from an analysis of ν_{e} appearance data from 12.84×10^{20} protons on target in neutrino mode, an increase of approximately a factor of 2 over previously reported results. A ν_{e} charged-current quasielastic event excess of 381.2±85.2 events (4.5σ) is observed in the energy range 200

3.
Phys Rev Lett ; 120(14): 141802, 2018 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-29694148

RESUMO

We report the first measurement of monoenergetic muon neutrino charged current interactions. MiniBooNE has isolated 236 MeV muon neutrino events originating from charged kaon decay at rest (K^{+}→µ^{+}ν_{µ}) at the NuMI beamline absorber. These signal ν_{µ}-carbon events are distinguished from primarily pion decay in flight ν_{µ} and ν[over ¯]_{µ} backgrounds produced at the target station and decay pipe using their arrival time and reconstructed muon energy. The significance of the signal observation is at the 3.9σ level. The muon kinetic energy, neutrino-nucleus energy transfer (ω=E_{ν}-E_{µ}), and total cross section for these events are extracted. This result is the first known-energy, weak-interaction-only probe of the nucleus to yield a measurement of ω using neutrinos, a quantity thus far only accessible through electron scattering.

4.
Phys Rev Lett ; 118(22): 221803, 2017 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-28621993

RESUMO

The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86×10^{20} protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the dark matter cross section parameter, Y=ε^{2}α_{D}(m_{χ}/m_{V})^{4}≲10^{-8}, for α_{D}=0.5 and for dark matter masses of 0.01

5.
Phys Rev Lett ; 110(16): 161801, 2013 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-23679593

RESUMO

The MiniBooNE experiment at Fermilab reports results from an analysis of ν[over ¯](e) appearance data from 11.27×10(20) protons on target in the antineutrino mode, an increase of approximately a factor of 2 over the previously reported results. An event excess of 78.4±28.5 events (2.8σ) is observed in the energy range 200

6.
Phys Rev Lett ; 105(18): 181801, 2010 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-21231096

RESUMO

The MiniBooNE experiment at Fermilab reports results from a search for ¯ν_{µ}→¯ν_{e} oscillations, using a data sample corresponding to 5.66×10²° protons on target. An excess of 20.9±14.0 events is observed in the energy range 475

7.
An Pediatr (Barc) ; 82(4): 228-34, 2015 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-24582518

RESUMO

INTRODUCTION: Total splenectomy in sickle cell disease is related to a high risk of fulminant sepsis and increased incidence of other events, which have not been reported in patients with partial splenectomy. In this study we examined the patients with sickle cell disease and partial splenectomy and compared the clinical and laboratory results with non-splenectomized patients. MATERIAL AND METHODS: We studied 54 patients with sickle cell disease who underwent partial splenectomy in childhood from 1986 until 2011 at the Institute of Hematology and Immunology. They were compared with 54 non-splenectomized patients selected by random sampling with similar characteristics. RESULTS: Partial splenectomy was performed at a mean age of 4.1 years, with a higher frequency in homozygous hemoglobin S (70.4%), and the most common cause was recurrent splenic sequestration crisis. The most common postoperative complications were fever of unknown origin (14.8%) and acute chest syndrome (11.1%). After splenectomy there was a significant increase in leukocytes, neutrophils, and platelets, the latter two parameters remained significantly elevated when compared with non-splenectomized patients. There was no difference in the incidence of clinical events, except hepatic sequestration, which was more common in splenectomized patients. CONCLUSION: Partial splenectomy was a safe procedure in patients with sickle cell disease. There were no differences in the clinical picture in children splenectomized and non-splenectomized except the greater frequency of hepatic sequestration crisis in the first group.


Assuntos
Anemia Falciforme/complicações , Esplenectomia/métodos , Esplenopatias/etiologia , Esplenopatias/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Adulto Jovem
9.
Biophys J ; 90(9): 3288-99, 2006 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-16461393

RESUMO

Zero mode waveguides (ZMWs), subwavelength optical nanostructures with dimensions ranging from 50 to 200 nm, have been used to study systems involving ligand-receptor interactions. We show that under proper conditions, lipid membranes will invaginate into the nanostructures, which confine optical excitation to subattoliter volumes. Fluorescence correlation spectroscopy (FCS) was used to characterize the diffusion of fluorescently tagged lipids in liquid-disordered phase 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and gel phase 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) membranes incubated on the nanostructured surface. In contrast to the POPC, DSPC membranes did not appear to enter the structures, suggesting that invagination is dependent on membrane rigidity. Although correlation curves obtained from POPC membranes conformed to previously derived models for diffusion in the evanescent field within the nanostructure, the diffusion constants obtained were systematically lower than expected. The validity of the one-dimensional diffusion model for membrane diffusion is discussed and it is concluded that the erroneous diffusion constants are a result of nontrivial membrane conformation within the ZMWs. Additionally, FCS was used to characterize the fraction of fluorescently labeled tetanus toxin C fragment bound to a ganglioside-populated POPC membrane within the ZMWs. This allowed the determination of the toxin's equilibrium binding constant at a concentration of 500 nM; higher than possible with diffraction-limited FCS. To our knowledge, the results presented here are the first reported for supported lipid bilayers in nanostructured devices. Furthermore, they open the possibility of studying membrane imbedded receptors and proteins at physiological concentrations with single-molecule resolution.


Assuntos
Bicamadas Lipídicas/química , Fosfatidilcolinas , Gangliosídeos/química , Gangliosídeos/metabolismo , Modelos Biológicos , Nanoestruturas/química , Espectrometria de Fluorescência , Toxina Tetânica/química , Toxina Tetânica/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA