Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Magn Reson Med ; 92(4): 1670-1682, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38703021

RESUMO

PURPOSE: This study aims to investigate a multiparametric exchange proton approach using CEST and Z-spectrum analysis protons (ZAP) in human abdominal organs, focusing on tissue differentiation for a potential early biomarker of abnormality. Prior to human studies, CEST and ZAP effects were studied in phantoms containing exchange protons. METHODS: Phantoms composed of iopamidol and iohexol solutions with varying pH levels, along with 12 human subjects, were scanned on a clinical 3T MR scanner. Subsequent ZAP analyses employed a two-Lorentzian pool model to provide free and restricted apparent T 2 f , r ex $$ {\mathrm{T}}_{2\ \mathrm{f},\mathrm{r}}^{\mathrm{ex}} $$ , and their fractions for data acquired across a wide range of offset frequencies (±100 kHz or ± 800 ppm), while a narrower range (±7 ppm or ± 900 Hz) was used for CEST analysis to estimate magnetization transfer ratio asymmetry (MTRAsym) for exchange protons like hydroxyl (-OH), amine (-NH2), and amide (-NH), resonating ˜1, 2, and 3.5 ppm, respectively. Differences in ZAP metrics across various organs were statistically analyzed using one-way analysis of variance (ANOVA). RESULTS: The phantom study differentiated contrast agents based on resonance peaks detected from CEST analysis, while ZAP metrics showed sensitivity to pH variations. In human, ZAP metrics revealed significant differences in abdominal organs, with a subgroup study indicating changes in ZAP metrics due to the presence of gallstones. CONCLUSION: CEST and ZAP techniques demonstrated promise in specific CEST protons and wide range ZAP protons and identifying tissue-specific characteristics. The preliminary findings underscore the necessity for more extensive study involving a broader subject pool to potentially establish biomarkers for diseased states.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Prótons , Humanos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Masculino , Adulto , Feminino , Concentração de Íons de Hidrogênio , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Adulto Jovem , Meios de Contraste/química
2.
MAGMA ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916681

RESUMO

PURPOSE: To develop a new MR coronary angiography (MRCA) technique by employing a zigzag fan-shaped centric ky-kz k-space trajectory combined with high-resolution deep learning reconstruction (HR-DLR). METHODS: All imaging data were acquired from 12 healthy subjects and 2 patients using two clinical 3-T MR imagers, with institutional review board approval. Ten healthy subjects underwent both standard 3D fast gradient echo (sFGE) and centric ky-kz k-space trajectory FGE (cFGE) acquisitions to compare the scan time and image quality. Quantitative measures were also performed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as sharpness of the vessel. Furthermore, the feasibility of the proposed cFGE sequence was assessed in two patients. For assessing the feasibility of the centric ky-kz trajectory, the navigator-echo window of a 30-mm threshold was applied in cFGE, whereas sFGE was applied using a standard 5-mm threshold. Image quality of MRCA using cFGE with HR-DLR and sFGE without HR-DLR was scored in a 5-point scale (non-diagnostic = 1, fair = 2, moderate = 3, good = 4, and excellent = 5). Image evaluation of cFGE, applying HR-DLR, was compared with sFGE without HR-DLR. Friedman test, Wilcoxon signed-rank test, or paired t tests were performed for the comparison of related variables. RESULTS: The actual MRCA scan time of cFGE with a 30-mm threshold was acquired in less than 5 min, achieving nearly 100% efficiency, showcasing its expeditious and robustness. In contrast, sFGE was acquired with a 5-mm threshold and had an average scan time of approximately 15 min. Overall image quality for MRCA was scored 3.3 for sFGE and 2.7 for cFGE without HR-DLR but increased to 3.6 for cFGE with HR-DLR and (p < 0.05). The clinical result of patients obtained within 5 min showed good quality images in both patients, even with a stent, without artifacts. Quantitative measures of SNR, CNR, and sharpness of vessel presented higher in cFGE with HR-DLR. CONCLUSION: Our findings demonstrate a robust, time-efficient solution for high-quality MRCA, enhancing patient comfort and increasing clinical throughput.

3.
Endocr J ; 71(7): 661-674, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38749736

RESUMO

The placenta secretes a prolactin (PRL)-like hormone PRL3B1 (placental lactogen II), a luteotropic hormone essential for maintaining pregnancy until labor in mice. A report from 1984 examined the secretion pattern of PRL3B1 in prepartum mice. In the current study, we found contradictory findings in the secretion pattern that invalidate the previous report. By measuring maternal plasma PRL3B1 and PRL every 4 hrs from gestational day 17 (G17), we newly discovered that maternal plasma PRL3B1 levels decrease rapidly in prepartum C57BL/6 mice. Interestingly, the onset of this decline coincided with the PRL surge at G18, demonstrating a plasma prolactin axis shift from placental to pituitary origin. We also found that maternal plasma progesterone regression precedes the onset of the PRL shift. The level of Prl3b1 mRNA was determined by RT-qPCR in the placenta and remained stable until parturition, implying that PRL3B1 peptide production or secretion was suppressed. We hypothesized that production of the PRL family, the 25 paralogous PRL proteins exclusively expressed in mice placenta, would decrease alongside PRL3B1 during this period. To investigate this hypothesis and to seek proteomic changes, we performed a shotgun proteome analysis of the placental tissue using data-independent acquisition mass spectrometry (DIA-MS). Up to 5,891 proteins were identified, including 17 PRL family members. Relative quantitative analysis between embryonic day 17 (E17) and E18 placentas showed no significant difference in the expression of PRL3B1 and most PRL family members except PRL7C1. These results suggest that PRL3B1 secretion from the placenta is suppressed at G18 (E18).


Assuntos
Camundongos Endogâmicos C57BL , Hipófise , Placenta , Prolactina , Animais , Gravidez , Feminino , Prolactina/sangue , Prolactina/metabolismo , Placenta/metabolismo , Hipófise/metabolismo , Camundongos , Lactogênio Placentário/metabolismo , Lactogênio Placentário/genética , Progesterona/sangue , Progesterona/metabolismo
4.
Jpn J Radiol ; 42(7): 785-797, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38536557

RESUMO

PURPOSE: This study aimed to develop novel non-contrast MR perfusion techniques for assessing micro-vascularity of the foot in human subjects. METHODS: All experiments were performed on a clinical 3 T scanner using arterial spin labeling (ASL). Seven healthy subjects (30-72 years old, 5 males and 2 females) were enrolled and bilateral feet were imaged with tag-on and tag-off alternating inversion recovery spin labeling for determining micro-vascularity. We compared an ASL technique with 1-tag against 4-tag pulses. For perfusion, we determined signal increase ratio (SIR) at varying inversion times (TI) from 0.5 to 2 s. SIR versus TI data were fit to determine perfusion metrics of peak height (PH), time to peak (TTP), full width at half maximum (FWHM), area under the curve (AUC), and apparent blood flow (aBF) in the distal foot and individual toes. Using analysis of variance (ANOVA), effects of tag pulse and region of interest (ROI) on the mean perfusion metrics were assessed. In addition, a 4-tag pulse perfusion experiment was performed on patients with peripheral artery disease (PAD) and Raynaud's disease. RESULTS: Using our MR perfusion techniques, SIR versus TI data showed well-defined leading and trailing edges, with a peak near TI of 0.75-1.0 s and subsiding quickly to near zero by TI of 2 s, particularly when 4-tag pulses were used. When imaged with 4-tag pulse, we found significantly greater values in perfusion metrics, as compared to 1-tag pulse. The patients with PAD and Raynaud's disease showed a reduced or scattered perfusion curves compared to the healthy control. CONCLUSION: MR perfusion imaging of the distal foot shows greater SIR and perfusion metrics with the 4-tag pulse compared to the 1-tag pulse technique. This will likely benefit those with low perfusion due to aging, PAD, diabetic foot, and other vascular diseases.


Assuntos
, Dedos do Pé , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Pé/irrigação sanguínea , Pé/diagnóstico por imagem , Dedos do Pé/irrigação sanguínea , Dedos do Pé/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Doença de Raynaud/diagnóstico por imagem , Doença de Raynaud/fisiopatologia
5.
Abdom Radiol (NY) ; 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39031182

RESUMO

This review article focuses on the advancements in non-contrast magnetic resonance angiography (NC-MRA) and its increasing importance in body imaging, especially for patients with renal complications, pregnant women, and children. It highlights the relevance of NC-MRA in chest, abdominal, and pelvis imaging and details various bright-blood NC-MRA techniques like cardiac-gated 3D Fast Spin Echo (FSE), balanced Steady-State Free Precession (bSSFP), Arterial Spin Labeling (ASL), and 4D flow methods. The article explains the operational principles of these techniques, their clinical applications, and their advantages over traditional contrast-enhanced methods. Special attention is given to the utility of these techniques in diverse imaging scenarios, including liver, renal, and pelvic imaging. The article underscores the growing importance of NC-MRA in medical diagnostics, offering insights into current practices and potential future developments. This comprehensive review is a valuable resource for radiologists and clinicians, emphasizing NC-MRA's role in enhancing patient care and diagnostic accuracy across various medical conditions.

6.
Bioengineering (Basel) ; 11(7)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39061790

RESUMO

Intrinsic cerebrospinal fluid (CSF) dynamics in the brain have been extensively studied, particularly the egress sites of tagged intrinsic CSF in the meninges. Although spinal CSF recirculates within the central nervous system (CNS), we hypothesized that CSF outflows from the lumbar spinal canal. We aimed to visualize and semi-quantify the outflow using non-contrast MRI techniques. We utilized a 3 Tesla clinical MRI with a 16-channel spine coil, employing time-spatial labeling inversion (Time-SLIP) with tag-on and tag-off acquisitions, T2-weighted coronal 2D fluid-attenuated inversion recovery (FLAIR) and T2-weighted coronal 3D centric ky-kz single-shot FSE (cSSFSE). Images were acquired using time-spatial labeling inversion pulse (Time-SLIP) with tag-on and tag-off acquisitions with varying TI periods. Ten healthy volunteers with no known spinal diseases participated. Variations in tagged CSF outflow were observed across different thoracolumbar nerve root segments in all participants. We quantified CSF outflow at all lumbar levels and the psoas region. There was no significant difference among the ROIs for signal intensity. The tagged CSF outflow from the spinal canal is small but demonstrates egress to surrounding tissues. This finding may pave the way for exploring intrathecal drug delivery, understanding of CSF-related pathologies and its potential as a biomarker for peripheral neuropathy and radiculopathy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA