Resultados 1 - 15 de 15
Filtrar
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(3): 209-17, 2016 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-27000669

RESUMO

PURPOSE: Recently, the quality of positron emission tomography (PET) images has rapidly improved using resolution recovery algorithm with point spread function (PSF). The aim of this study was to investigate the accuracy of the resolution recovery algorithm using three different PET systems. METHODS: Three PET scanner models, the GE Discovery 600 M (D600M), SIEMENS Biograph mCT (mCT), and SHIMADZU SET-3000GCT/X (3000GCT) were used in this study. The radial dependences of spatial resolution (full width at half maximum: FWHM) were obtained by point source measurements (0.9 mmφ). All PET data were acquired in three-dimensional (3D) mode and reconstructed using the filtered back projection (FBP) , 3D-ordered subsets expectation maximization (3D-OSEM or dynamic row-action maximum likelihood algorithm) , and 3D-OSEM+PSF (PSF) algorithms. Two indicators, aspect ratio (ASR) and resolution recovery ratio (RRR), were calculated from measured FWHMs and compared among the three PET scanners. RESULTS: In D600 and 3000GCT, distortions of the radial direction were slightly increased at circumference of field of view (FOV). On the other hand, random distortions were occurred in both radial and tangential direction in mCT. ASRs calculated from 3D-OSEM images at circumference of FOV were 2.06, 1.22, and 2.04 on D600M, mCT, and 3000GCT, respectively. ASR improved with PSF in all PET scanners. On the other hand, RRR with PSF were calculated 57.6%, 61.4%, and 31.6%, respectively. CONCLUSION: Our results suggest that the spatial resolutions of PET images could be improved with PSF algorithm in all PET systems; however, effect of PSF was different depending on PET systems. Furthermore, PSF algorithm could not completely improve spatial resolutions in circumference of FOV.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Algoritmos , Simulação por Computador , Tomografia por Emissão de Pósitrons/métodos , Sensibilidade e Especificidade
2.
J Imaging Inform Med ; 37(1): 167-179, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343219

RESUMO

Deep learning (DL) has recently attracted attention for data processing in positron emission tomography (PET). Attenuation correction (AC) without computed tomography (CT) data is one of the interests. Here, we present, to our knowledge, the first attempt to generate an attenuation map of the human head via Sim2Real DL-based tissue composition estimation from model training using only the simulated PET dataset. The DL model accepts a two-dimensional non-attenuation-corrected PET image as input and outputs a four-channel tissue-composition map of soft tissue, bone, cavity, and background. Then, an attenuation map is generated by a linear combination of the tissue composition maps and, finally, used as input for scatter+random estimation and as an initial estimate for attenuation map reconstruction by the maximum likelihood attenuation correction factor (MLACF), i.e., the DL estimate is refined by the MLACF. Preliminary results using clinical brain PET data showed that the proposed DL model tended to estimate anatomical details inaccurately, especially in the neck-side slices. However, it succeeded in estimating overall anatomical structures, and the PET quantitative accuracy with DL-based AC was comparable to that with CT-based AC. Thus, the proposed DL-based approach combined with the MLACF is also a promising CT-less AC approach.

3.
J Nucl Med ; 64(1): 153-158, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35798557

RESUMO

We acquired brain 18F-FDG and 18F-flutemetamol PET images using a time-of-flight system dedicated to the head (dhPET) and a conventional whole-body PET/CT (wbPET) system and evaluated the clinical superiority of dhPET over wbPET. Methods: There were 18 subjects for the 18F-FDG PET study and 17 subjects for the 18F-flutemetamol PET study. 18F-FDG PET images were first obtained using wbPET, followed by dhPET. 18F-flutemetamol PET images were first obtained using wbPET, followed by dhPET. Images acquired using dhPET and wbPET were compared by visual inspection, voxelwise analysis, and SUV ratio (SUVR). Results: All 18F-FDG and 18F-flutemetamol images acquired using dhPET were judged as visually better than those acquired using wbPET. The voxelwise analysis demonstrated that accumulations in the cerebellum, in the lateral occipital cortices, and around the central sulcus area in dhPET 18F-FDG images were lower than those in wbPET 18F-FDG images, whereas accumulations around the ventricle systems were higher in dhPET 18F-FDG images than those in wbPET 18F-FDG images. Accumulations in the cerebellar dentate nucleus, in the midbrain, in the lateral occipital cortices, and around the central sulcus area in dhPET images were lower than those in wbPET images, whereas accumulations around the ventricle systems were higher in dhPET 18F-flutemetamol images than those in wbPET 18F-flutemetamol images. The mean cortical SUVRs of 18F-FDG and 18F-flutemetamol dhPET images were significantly higher than those of 18F-FDG and 18F-flutemetamol wbPET images, respectively. Conclusion: The dhPET images had better image quality by visual inspection and higher SUVRs than wbPET images. Although there were several regional accumulation differences between dhPET and wbPET images, understanding this phenomenon will enable full use of the features of this dhPET system in clinical practice.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem
4.
EJNMMI Phys ; 9(1): 88, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36525103

RESUMO

BACKGROUND: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. METHODS: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures. RESULTS: The tangential, radial, and axial full width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset was 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods was clearly visualized. CONCLUSION: Taken together, these results indicate that the head- and breast-dedicated PET system has high resolution and is well suited for clinical PET imaging.

5.
Ann Nucl Med ; 36(4): 420-426, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35138565

RESUMO

AIM: The aim of this study was to evaluate an image reconstruction algorithm, including a new maximum-likelihood attenuation correction factor (ML-ACF) for time of flight (TOF) brain positron emission tomography (PET). METHODS: The implemented algorithm combines an ML-ACF method that simultaneously estimates both the emission image and attenuation sinogram from TOF emission data, and a scaling method based on anatomical features. To evaluate the algorithm's quantitative accuracy, three-dimensional brain phantom images were acquired and soft-tissue attenuation coefficients and emission values were analyzed. RESULTS: The heterogeneous distributions of attenuation coefficients in soft tissue, skull, and nasal cavity were sufficiently visualized. The attenuation coefficient of soft tissue remained within 5% of theoretical value. Attenuation-corrected emission showed no lateral differences, and significant differences among soft tissue were within the error range. CONCLUSION: The ML-ACF-based attenuation correction implemented for TOF brain PET worked well and obtained practical levels of accuracy.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Crânio
6.
Ann Nucl Med ; 36(11): 998-1006, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36167889

RESUMO

OBJECTIVES: This study evaluates the phantom attenuation correction (PAC) method as an alternative to maximum-likelihood attenuation correction factor (ML-ACF) correction in time-of-flight (TOF) brain positron emission tomography (PET) studies. METHODS: In the PAC algorithm, a template emission image [Formula: see text] and a template attenuation coefficient image [Formula: see text] are prepared as a data set based on phantom geometry. Position-aligned attenuation coefficient image [Formula: see text] is derived by aligning [Formula: see text] using parameters that match the template emission image [Formula: see text] to measured emission image [Formula: see text]. Then, attenuation coefficient image [Formula: see text] combined with a headrest image is used for scatter and attenuation correction in the image reconstruction. To evaluate the PAC algorithm as an alternative to ML-ACF, Hoffman 3D brain and cylindrical phantoms were measured to obtain the image quality indexes of contrast and uniformity. These phantoms were also wrapped with a radioactive sheet to obtain attenuation coefficient images using ML-ACF. Emission images were reconstructed with attenuation correction by PAC and ML-ACF, and the results were compared using contrast and uniformity as well as visual assessment. CT attenuation correction (CT-AC) was also applied as a reference. RESULTS: The contrast obtained by ML-ACF was slightly overestimated due to its unique experimental condition for applying ML-ACF in Hoffman 3D brain phantom but the uniformity was almost equivalent among ML-ACF, CT-AC, and PAC. PAC showed reasonable result without overestimation compared to ML-ACF and CT-AC. CONCLUSIONS: PAC is an attenuation correction method that can ensure the performance in phantom test, and is considered to be a reasonable alternative to clinically used ML-ACF-based attenuation correction.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Imageamento por Ressonância Magnética/métodos
7.
J Nucl Med ; 49(1): 50-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18077532

RESUMO

UNLABELLED: Quantitative PET with (15)O provides absolute values for cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)), and oxygen extraction fraction (OEF), which are used for assessment of brain pathophysiology. Absolute quantification relies on physically accurate measurement, which, thus far, has been achieved by 2-dimensional PET (2D PET), the current gold standard for measurement of CBF and oxygen metabolism. We investigated whether quantitative (15)O study with 3-dimensional PET (3D PET) shows the same degree of accuracy as 2D PET. METHODS: 2D PET and 3D PET measurements were obtained on the same day on 8 healthy men (age, 21-24 y). 2D PET was performed using a PET scanner with bismuth germanate (BGO) detectors and a 150-mm axial field of view (FOV). For 3D PET, a 3D-only tomograph with gadolinium oxyorthosilicate (GSO) detectors and a 156-mm axial FOV was used. A hybrid scatter-correction method based on acquisition in the dual-energy window (hybrid dual-energy window [HDE] method) was applied in the 3D PET study. Each PET study included 3 sequential PET scans for C(15)O, (15)O(2), and H(2)(15)O (3-step method). The inhaled (or injected) dose for 3D PET was approximately one fourth of that for 2D PET. RESULTS: In the 2D PET study, average gray matter values (mean +/- SD) of CBF, CBV, CMRO(2), and OEF were 53 +/- 12 (mL/100 mL/min), 3.6 +/- 0.3 (mL/100 mL), 3.5 +/- 0.5 (mL/100 mL/min), and 0.35 +/- 0.06, respectively. In the 3D PET study, scatter correction strongly affected the results. Without scatter correction, average values were 44 +/- 6 (mL/100 mL/min), 5.2 +/- 0.6 (mL/100 mL), 3.3 +/- 0.4 (mL/100 mL/min), and 0.39 +/- 0.05, respectively. With the exception of OEF, values differed between 2D PET and 3D PET. However, average gray matter values of scatter-corrected 3D PET were comparable to those of 2D PET: 55 +/- 11 (mL/100 mL/min), 3.7 +/- 0.5 (mL/100 mL), 3.8 +/- 0.7 (mL/100 mL/min), and 0.36 +/- 0.06, respectively. Even though the 2 PET scanners with different crystal materials, data acquisition systems, spatial resolution, and attenuation-correction methods were used, the agreement of the results between 2D PET and scatter-corrected 3D PET was excellent. CONCLUSION: Scatter coincidence is a problem in 3D PET for quantitative (15)O study. The combination of both the present PET/CT device and the HDE scatter correction permits quantitative 3D PET with the same degree of accuracy as 2D PET and with a lower radiation dose. The present scanner is also applicable to conventional steady-state (15)O gas inhalation if inhaled doses are adjusted appropriately.


Assuntos
Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Radioisótopos de Oxigênio , Oxigênio/metabolismo , Adulto , Tempo de Circulação Sanguínea , Gasometria , Encéfalo/irrigação sanguínea , Humanos , Masculino , Tomografia por Emissão de Pósitrons/métodos , Valores de Referência
8.
Ann Nucl Med ; 22(5): 447-55, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18600425

RESUMO

OBJECTIVE: In this study, we evaluated the performance of a newly commercialized small-animal positron emission tomography (PET) scanner, ClairvivoPET, which provides significant advantages in spatial resolution, sensitivity, and quantitative accuracy. METHODS: This scanner consists of depth of interaction detector modules with a large axial extent of 151 mm and an external (137)Cs source for attenuation correction. Physical performances, resolution, sensitivity, scatter fraction (SF), counting rate including noise equivalent count (NEC) rate, quantitative accuracy versus activity strength, and transmission accuracy, were measured and evaluated. Animal studies were also performed. RESULTS: Transaxial spatial resolution, measured with a capillary tube, was 1.54 mm at the center and 2.93 mm at a radial offset of 40 mm. The absolute sensitivity was 8.2% at the center, and SFs for mouse-and rat-sized phantoms were 10.7% and 24.2%, respectively. Peak NEC rates for mouse-and rat-sized uniform cylindrical phantoms were 328 kcps at 173 kBq/ml and 119 kcps at 49 kBq/ml, respectively. The quantitative stability of emission counts against activity strength was within 2% over 5 half-lives, ranging from 0.6 MBq to 30 MBq. Transmission measurement based on segmented attenuation correction allowed 6-min and 10-min scans for mouse-and rat-sized cylindrical phantoms, respectively. Rat imaging injected with (18)F-NaF resulted in visibility of fine bone structures, and mouse imaging injected with (18)F-D-fluoromethyl tyrosine demonstrated the feasibility of using this system to obtain simultaneous time activity curves from separate regions, such as for the heart and tumors. CONCLUSIONS: ClairvivoPET is well suited to quantitative imaging even with short scan times, and will provide a number of advantages in new drug development and for kinetic measurement in molecular imaging.


Assuntos
Aumento da Imagem/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/veterinária , Imagem Corporal Total/instrumentação , Imagem Corporal Total/veterinária , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Nucl Med ; 47(1): 83-90, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16391191

RESUMO

UNLABELLED: The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan time. We evaluated the physical performance of the SET-3000 G/X PET scanner with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. METHODS: A GSO 3D emission scanner is combined with a BGO transmission scanner separated axially by a lead shield. In the GSO scanner, small and thick scintillators (2.45 x 5.1 x 30 mm(3)) are arranged in small blocks (23.1 x 52 mm) to achieve high resolution and a high counting rate. The detector ring has a large solid angle with a diameter of 664 mm and an axial coverage of 260 mm (50 rings). The transmission scanner consists of BGO block detectors with a diameter of 798 mm and an axial width of 23.1 mm and is equipped with a rotating (137)Cs point source of 740 MBq and a tungsten collimator. The low- and high-energy thresholds are set to 400 and 700 keV, respectively, in the emission system. The coincidence time window is set to 6 ns. In CEST acquisition, the patient couch moves continuously through the emission and transmission scanners in a 1-way motion. Emission coincidence data are acquired in the histogram mode with on-the-fly Fourier rebinning, and transmission single data are acquired with emission contamination correction. RESULTS: With the NEMA NU 2-2001 standard, the main performance results were as follows: the average (radial and tangential) transverse and axial spatial resolutions (full width at half maximum) at 1 cm and at 10 cm off axis were 3.49 and 5.04 mm and 4.48 and 5.40 mm, respectively; the average sensitivity for the 2 radial positions (0 and 10 cm) was 20.71 cps/kBq; the scatter fraction was 50%; the peak noise equivalent count rate was 62.3 kcps at 9.8 kBq/mL; and the peak random rate was 542.1 kcps at 37.6 kBq/mL. CONCLUSION: The new integrated SET-3000 G/X PET scanner has good overall performance, including high resolution and sensitivity, and has the potential of reducing whole-body acquisition time to less than 10 min while improving small-lesion detectability with a low radiation dose.


Assuntos
Câmaras gama , Guias como Assunto , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/normas , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/normas , Humanos , Aumento da Imagem/normas , Imageamento Tridimensional/normas , Japão , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(2): 289-96, 2006 Feb 20.
Artigo em Japonês | MEDLINE | ID: mdl-16520713

RESUMO

UNLABELLED: Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. METHODS: Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. RESULTS: In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation coefficients was stable with all phantoms. CONCLUSION: We evaluated the accuracy of attenuation coefficients of Cs-137 single-transmission scans. The results for Cs-137 suggest that scattered photons depend on object size. Although Cs-137 single-transmission scans contained scattered photons, attenuation coefficient error could be reduced using by the segmentation method.


Assuntos
Radioisótopos de Césio , Germânio , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos , Imagens de Fantasmas , Espalhamento de Radiação
12.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(1): 78-85, 2006 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-16456508

RESUMO

UNLABELLED: The SET-3000 G/X (Shimadzu Corp., Kyoto, Japan) has a large aperture and functions as a three-dimensional (3D) dedicated PET scanner. However, the large number of line of responses in the SET-3000 G/X scanner creates a large volume of sinogram data and prolongs reconstruction time in iterative reconstruction. The purpose of this study was to optimize basic acquisition parameters (maximum ring difference and span) for sensitivity and spatial resolution for 3D whole-body (18)F-FDG PET. METHODS: Detector rings and image planes numbered 50 and 99, respectively. In sensitivity measurement, the maximum ring difference (MRD) was changed from 1 to 49. In the measurement of spatial resolution, the span was changed from 3 to 21. For sensitivity and spatial resolution measurements, the standard protocols defined by the Japan Radioisotope Association (JRIA) 1994 and the National Electrical Manufacturers Association (NEMA) NU 2-2001 were used. We also evaluated the corresponding image noise by placing identical ROI on the reconstructed images. RESULTS: The total sensitivity of MRD=49 was 85.7 cps/Bq/ml in a uniform phantom (15 cm diameter, 30 cm tall cylinder) filled with (18)F. This was approximately two times higher than MRD=13. The image noise in the center of the axial FOV decreased with increasing MRD. Spatial resolution was slightly decreased as MRD increased, but axial resolution deteriorated with a span of more than 11. CONCLUSION: Optimum basic data-acquisition parameters for whole-body (18)F-FDG PET were MRD 49 to obtain maximum sensitivity and span 9 to avoid decreasing spatial resolution. Additionally, it was concluded that the basic data-acquisition parameters should be carefully selected for 3D whole-body (18)F-FDG PET in order to maximize the efficiency of PET measurement.


Assuntos
Processamento Eletrônico de Dados , Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
13.
Ann Nucl Med ; 30(10): 690-698, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27534771

RESUMO

OBJECTIVE: Positron emission tomography (PET) enables quantitative measurements of various biological functions. Accuracy in data acquisition and processing schemes is a prerequisite for this. The correction of scatter is especially important when a 3D PET scanner is used. The aim of this study was to validate the use of a simplified calculation-based scatter correction method for 15O studies in the brain. METHODS: We applied two scatter correction methods to the same 15O PET data acquired from patients with cerebrovascular disease (n = 10): a hybrid dual-energy-window scatter correction (reference method), and a deconvolution scatter correction (simplified method). The PET study included three sequential scans for 15O-CO, 15O-O2, and 15O-H2O, from which the following quantitative parameters were calculated, cerebral blood flow, cerebral blood volume, cerebral metabolic rate of oxygen, and oxygen extraction fraction. RESULTS: Both scatter correction methods provided similar reconstruction images with almost identical image noise, although there were slightly greater differences in white-matter regions compared with gray matter regions. These differences were also greater for 15O-CO than for 15O-H2O and 15O-O2. Region of interest analysis of the quantitative parameters demonstrated that the differences were less than 10 % (except for cerebral blood volume in white-matter regions), and the agreement between the methods was excellent, with intraclass correlation coefficients above 0.95 for all the parameters. CONCLUSIONS: The deconvolution scatter correction despite its simplified implementation provided similar results to the hybrid dual-energy-window scatter correction. We consider it suitable for application in a clinical 15O brain study using a 3D PET scanner.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Espalhamento de Radiação , Humanos
14.
Ann Nucl Med ; 23(7): 627-38, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19562437

RESUMO

OBJECTIVE: A modified version of row-action maximum likelihood algorithm (RAMLA) using a 'subset-dependent' relaxation parameter for noise suppression, or dynamic RAMLA (DRAMA), has been proposed. The aim of this study was to assess the capability of DRAMA reconstruction for quantitative (15)O brain positron emission tomography (PET). METHODS: Seventeen healthy volunteers were studied using a 3D PET scanner. The PET study included 3 sequential PET scans for C(15)O, (15)O(2) and H (2) (15) O. First, the number of main iterations (N (it)) in DRAMA was optimized in relation to image convergence and statistical image noise. To estimate the statistical variance of reconstructed images on a pixel-by-pixel basis, a sinogram bootstrap method was applied using list-mode PET data. Once the optimal N (it) was determined, statistical image noise and quantitative parameters, i.e., cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)) and oxygen extraction fraction (OEF) were compared between DRAMA and conventional FBP. DRAMA images were post-filtered so that their spatial resolutions were matched with FBP images with a 6-mm FWHM Gaussian filter. RESULTS: Based on the count recovery data, N (it) = 3 was determined as an optimal parameter for (15)O PET data. The sinogram bootstrap analysis revealed that DRAMA reconstruction resulted in less statistical noise, especially in a low-activity region compared to FBP. Agreement of quantitative values between FBP and DRAMA was excellent. For DRAMA images, average gray matter values of CBF, CBV, CMRO(2) and OEF were 46.1 +/- 4.5 (mL/100 mL/min), 3.35 +/- 0.40 (mL/100 mL), 3.42 +/- 0.35 (mL/100 mL/min) and 42.1 +/- 3.8 (%), respectively. These values were comparable to corresponding values with FBP images: 46.6 +/- 4.6 (mL/100 mL/min), 3.34 +/- 0.39 (mL/100 mL), 3.48 +/- 0.34 (mL/100 mL/min) and 42.4 +/- 3.8 (%), respectively. CONCLUSION: DRAMA reconstruction is applicable to quantitative (15)O PET study and is superior to conventional FBP in terms of image quality.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Circulação Cerebrovascular , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Oxigênio/metabolismo , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/normas , Padrões de Referência
15.
Mol Imaging Biol ; 11(6): 480-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19330382

RESUMO

PURPOSE: Patient noise equivalent count (NEC), NEC density, and liver region of interest (ROI) S/N have been proposed as physical indicators of image quality, but have not been thoroughly compared with visual assessments. In this study, those indicators were contrasted with blind visual evaluations for whole-body fluorodeoxyglucose-positron emission tomography (FDG-PET) images acquired under a variety of scanning conditions and body weights. METHODS: Images were acquired on 15 normal subjects using a SET-3000B/L PET scanner with a continuous bed motion. Body weight ranged from 50.2 to 95.7 kg, with injected activity ranging from 71 to 333 MBq (1.40 to 3.67 MBq/kg) and a scan duration from 10 to 30 min. Patient NEC (PNEC; counts/cm) was calculated as the NEC rate divided by bed speed. NEC density (counts/cm(3)) was defined as the PNEC divided by the cross-sectional area derived from transmission data. Both PNEC and NEC density were averaged from neck to abdomen. Liver S/N was obtained as the pixel mean/SD within the ROI. Blind reviews by 18 professionals were used to visually evaluate image quality. RESULTS: Average visual score correlated with liver S/N, PNEC, and NEC density, with a rank correlation coefficient of 0.81, 0.86, and 0.91, respectively (each p < 0.0003). The "acceptable" quality roughly corresponded to a liver S/N of 10, PNEC of 380 kcounts/cm, and NEC density of 550 counts/cm(3) or more. CONCLUSIONS: NEC density, representing count statistics per body volume, reflects the visual image quality assessment and may be utilized for quality control of whole-body FDG-PET images together with the liver ROI S/N ratio.


Assuntos
Pesos e Medidas Corporais/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Adulto , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/instrumentação , Controle de Qualidade , Compostos Radiofarmacêuticos