Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Card Fail ; 21(10): 785-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26117282

RESUMO

BACKGROUND: Echocardiographic ramp tests have been widely used to help guide speed adjustments and for identification of potential device malfunctions in patients with axial continuous-flow left ventricular assist devices (LVADs) (Heartmate II LVAD [HMII]). Recently, the use of centrifugal-flow LVADs (Heartware LVAD [HVAD]) has been on the rise. The purpose of this study was to evaluate the utility of ramp tests for assessing ventricular decompression in HVAD patients. METHODS AND RESULTS: In this prospective study, ramp tests were performed before index hospitalization discharge or at the time of device malfunction. Vital signs, device parameters (including flow), and echocardiographic parameters (including left ventricular end-diastolic dimension [LVEDD], frequency of aortic valve [AV] opening, and valvular insufficiency) were recorded in increments of 100 rpm, from 2,300 rpm to 3,200 rpm. Twenty-six ramp tests were performed, 19 for speed optimization and 7 for device malfunction assessment. The average speed after the speed optimization ramp tests was 2,534.74 ± 156.32 RPM, and the AV closed at a mean speed of 2,751.77 ± 227.16 rpm, with 1 patient's valve remaining open at the maximum speed. The reduction in LVEDD for each speed increase was significantly different when the AV was open or closed, at -0.09 cm/increment and -0.15 cm/increment, respectively (P = .013), which is significantly different than previously established HMII LVEDD slopes. There were also significant changes in overall device flow (P = .001), upper flow (P = .031), and lower flow (P = .003) after AV closure. The power slope did not change significantly after the AV closed (P = .656). Five of the 19 tests were stopped before completion owing to suction events, but all tests reached ≥3,000 rpm. CONCLUSIONS: The parameter slopes for the HMII cannot be directly applied to ramp studies in HVAD patients. Overall, the LVEDD slope is drastically smaller in magnitude than the previously reported HMII findings, and speed adjustments were not based on the degree of left ventricular unloading. Therefore, the slope of the LVEDD-rpm relationship is not likely to be helpful in evaluating HVAD function.


Assuntos
Algoritmos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/normas , Função Ventricular Esquerda/fisiologia , Idoso , Estudos de Coortes , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
3.
J Endovasc Ther ; 18(1): 57-63, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21314350

RESUMO

PURPOSE: To evaluate the incidence of clinically evident hemolysis associated with orbital atherectomy used to treat severe peripheral artery disease. METHODS: The observational CLEAR study enrolled 31 subjects (16 men; mean age 71 ± 10 years, range 44-92) with claudication (58.1%) or critical limb ischemia (38.7%) who underwent orbital atherectomy with the Diamondback 360 system at 4 US centers. The 42 lesions in 31 limbs were located in the superficial femoral (n = 19, 45.2%), popliteal (n = 8, 19.0%), and tibial arteries (n = 15, 35.8%). The majority of lesions (34, 81.0%) were de novo; moderate or severe calcification was identified in 90.5% of cases. Lesion and procedural parameters were analyzed at a core laboratory. Blood samples were collected during and post procedure and analyzed for markers of hemolysis. The primary endpoint was the occurrence of clinically significant hemolysis. The secondary endpoints included the occurrence of any clinical symptoms/signs potentially related to hemolysis. Statistical analysis was performed to identify predictors for hemolysis. RESULTS: Laboratory evidence of hemolysis was seen in 11 (35.5%) subjects. No one met the clinical event criteria, and so the primary endpoint of the study was not reached. The secondary endpoints were hypertensive crisis (1, 3.2%) and transient hemoglobinuria (3, 9.7%). Lower glomerular filtration rates, calcified plaque, long atherectomy runs, and solid crown selection were independent predictors of hemolysis. CONCLUSION: There was no clinically significant hemolysis after orbital atherectomy. The results of this study will enable users to predict conditions that predispose to high levels of red cell hemolysis following orbital atherectomy and to take appropriate measures to limit its occurrence.


Assuntos
Aterectomia/efeitos adversos , Hemólise , Claudicação Intermitente/terapia , Isquemia/terapia , Doença Arterial Periférica/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aterectomia/instrumentação , Estado Terminal , Desenho de Equipamento , Feminino , Humanos , Claudicação Intermitente/etiologia , Isquemia/etiologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Estados Unidos
4.
Catheter Cardiovasc Interv ; 76(3): 326-32, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20839344

RESUMO

BACKGROUND: Plaque-debulking technologies have been proposed as alternative treatment options for peripheral arterial disease. Orbital atherectomy (OA), using the DiamondBack360 device, has emerged as one promising modality. METHODS: We evaluated the safety and efficacy of OA in the first 200 lesions treated at our institution. Patient demographics, clinical characteristics, and lesion and procedural variables were collected and analyzed. The primary safety endpoint was the 30-day major adverse events (MAE), including death, myocardial infarction, stroke, unplanned amputation, or target lesion revascularization. Other safety endpoints included access-site complications, occurrence of dissections, perforations, distal embolization, spasm, and hemolysis. The efficacy endpoints were procedural success, need for adjunctive therapy, and improvement in ankle-brachial index. Multivariate analysis was performed to find independent predictors of the safety endpoints. RESULTS: One hundred seventeen (58.5%) lesions were femoral, 31 (15.5%) were popliteal, and 52 (26.0%) were tibial. The procedural success (residual stenosis ≤30%) was comparable between the femoral and tibial lesions (86.3% vs. 92.5%, P = 0.18), but significantly lower for the popliteal lesions when compared with femoral and tibial (64.7% vs. 86.3%, P = 0.058, and 64.7% vs. 92.5%, P = 0.007 respectively). MAE at 30-days occurred in 3 (2.2%) procedures, and major access-site complications also occurred in 3 (2.2%). There were 31 (15.5%) dissections; independent predictors were diabetes mellitus (OR: 7.3, P = 0.008), crown-to-RVD ratio <0.6 (OR: 11.6, P = 0.005), and atherectomy time >360 sec (OR: 11.8, P = 0.001). There were 2 (1.0%) distal embolizations, 6 (3.0%) arterial spasms, and no perforations. Laboratory evidence of hemolysis was noted in 33.8% of cases. CONCLUSION: Orbital atherectomy allows for a significant procedural success, limited need for stenting, and favorable safety profile.


Assuntos
Aterectomia/métodos , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Índice Tornozelo-Braço , Aterectomia/efeitos adversos , Aterectomia/instrumentação , Aterectomia/mortalidade , Distribuição de Qui-Quadrado , Embolia/etiologia , Feminino , Hemólise , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Cidade de Nova Iorque , Razão de Chances , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Sistema de Registros , Medição de Risco , Fatores de Risco , Espasmo/etiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
5.
J Interv Cardiol ; 22(3): 261-5, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19490358

RESUMO

We reviewed data from the multicenter CARE (Cardiac Angiography in Renally Impaired Patients) study to see if benefit could be shown for N-acetylcysteine (NAC) in patients undergoing cardiac angiography who all received intravenous bicarbonate fluid expansion. Four hundred fourteen patients with moderate-to-severe chronic kidney disease were randomized to receive intra-arterial administration of iopamidol-370 or iodixanol-320. All patients were prehydrated with isotonic sodium bicarbonate solution. Each site chose whether or not to administer NAC 1,200 mg twice daily to all patients. Serum creatinine (SCr) levels and estimated glomerular filtration rate were assessed at baseline and 2-5 days after receiving contrast. The primary outcome was a postdose SCr increase 0.5 mg/dL (44.2 mumol/L) over baseline. Secondary outcomes were a postdose SCr increase 25% and the mean peak change in SCr. The NAC group received significantly less hydration (892 +/- 236 mL vs. 1016 +/- 328 mL; P < 0.001) and more contrast volume (146 +/- 74 mL vs. 127 +/- 71 mL; P = 0.009) compared with no-NAC group. SCr increases 0.5 mg/dL occurred in 4.2% (7 of 168 patients) in NAC group and 6.5% (16 of 246 patients) in no-NAC group (P = 0.38); rates of SCr increases 25% were 11.9% and 10.6%, respectively (P = 0.75); mean post-SCr increases were 0.07 mg/dL in NAC group versus 0.11 mg/dL in no-NAC group (P = 0.14). In conclusion, addition of NAC to fluid expansion with sodium bicarbonate failed to reduce the rate of contrast-induced nephropathy (CIN) after the intra-arterial administration of iopamidol or iodixanol to high-risk patients with chronic kidney disease.


Assuntos
Acetilcisteína/uso terapêutico , Angiografia Coronária , Sequestradores de Radicais Livres/uso terapêutico , Nefropatias/induzido quimicamente , Substitutos do Plasma , Bicarbonato de Sódio/uso terapêutico , Idoso , Soluções Tampão , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Humanos , Iopamidol , Masculino , Estudos Retrospectivos , Fatores de Risco , Ácidos Tri-Iodobenzoicos
6.
Case Rep Cardiol ; 2019: 2049704, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772780

RESUMO

Chylothorax is an exceedingly rare but serious complication of orthotopic heart transplantation (OHT). Prompt diagnosis and appropriate management are essential for a good outcome. Management is similar to that of nontransplant patients, but special attention must be given to patients' nutritional and immunological status. Relevant literature on this topic is limited. We describe our experience in the management of chylothorax after OHT and provide a summary of reported cases of this complication after isolated heart and combined heart/lung transplant.

8.
Turk Kardiyol Dern Ars ; 46(3): 231-233, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29664432

RESUMO

Presently described is a case of disseminated adenovirus infection in a heart-kidney transplant recipient that was successfully treated with cidofovir. There are several reports of adenovirus infections in adult solid organ transplant recipients and the prognosis is usually poor, with mortality rates of 40% to 60%. Severe disseminated adenovirus infections have been associated with increased risk of adverse transplant events, such as rejection, ventricular dysfunction, allograft vasculopathy, graft loss, and the need for re-transplantation. The patient's lack of clinical improvement, the onset of hemorrhagic cystitis and acute kidney injury were factors in our decision to temporarily discontinue administration of immunosuppressive agents and start an antiviral agent. It is important to suspect adenovirus in transplant patients when they do not respond to antibiotics and cultures are negative. Early diagnosis and treatment are critical to improving outcomes in immunocompromised patients.


Assuntos
Infecções por Adenoviridae , Transplante de Coração , Imunossupressores/efeitos adversos , Transplante de Rim , Adenoviridae , Infecções por Adenoviridae/tratamento farmacológico , Infecções por Adenoviridae/etiologia , Idoso , Antivirais/uso terapêutico , DNA Viral/sangue , Humanos , Rim/patologia , Masculino , Carga Viral
9.
Eur Heart J Acute Cardiovasc Care ; 5(8): 522-526, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25740223

RESUMO

Over the past decade, continuous flow left ventricular assist devices (CF-LVADs) have become the mainstay of therapy for end stage heart failure. While the number of patients on support is exponentially growing, at present there are no American Heart Association or European Society of Cardiology Advanced Cardiovascular Life Support guidelines for the management of this unique patient population. We propose an algorithm for the hospitalized unresponsive CF-LVAD patient outside of the intensive care unit setting. Key elements of this algorithm are: creation of a dedicated LVAD code pager and LVAD code team; early assessment and correction of LVAD malfunction; early determination of blood flow using Doppler technique in carotid and femoral arteries; prompt administration of external chest compressions in the absence of Doppler flow; bedside veno-arterial extracorporeal membranous oxygenation support if no response to resuscitation measures; and early consideration for stroke.


Assuntos
Suporte Vital Cardíaco Avançado/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Algoritmos , Gerenciamento Clínico , Humanos , Unidades de Terapia Intensiva
10.
J Heart Lung Transplant ; 35(1): 108-114, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26476767

RESUMO

BACKGROUND: Drive-line infection (DLI) is a common complication of left ventricular assist device (LVAD) support, leading to significant morbidity that jeopardizes the benefits of these devices. It has been reported that DLI incidence is related to drive-line dressing strategies. The aim of this study was to determine whether implementation of a standardized drive-line care kit would reduce the incidence of DLIs. METHODS: DLI data were collected prospectively on all LVAD patients implanted between 2009 and 2013 at Columbia University Medical Center. Drive-line care was altered on June 1, 2011, from a dry sterile dressing without a standard anchoring device to a standardized kit, which included silver gauze dressing and a standard anchoring device. The silver dressing was used until the wound incorporated, with a minimum of 1 month. RESULTS: During the study period, 107 patients were implanted with LVADs before implementation of a standardized kit (Group A) and 159 thereafter (Group B). Median follow-up time (censoring at June 2011) for Group A was 8.73 (IQR 3.51 to 17.47) months and 11.65 (IQR 6.66 to 35.20) months for Group B (p = 0.17). DLI event rate improved from 0.18 to 0.07 event per patient-year, corresponding to a relative risk reduction of 62.5%. In addition, the 1-year freedom from infection was significantly increased in Group B (92.46%) compared with Group A (81.94%) (log rank = 0.036). CONCLUSION: The use of a standardized kit, including silver dressing and a standard anchoring device, leads to decrease in DLI with an absolute risk reduction of 11%. Routine use of these dressing techniques is warranted based on our findings, and may lead to reduction of complications related to infections.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Guias de Prática Clínica como Assunto , Infecções Relacionadas à Prótese/prevenção & controle , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Infecções Relacionadas à Prótese/epidemiologia , Estudos Retrospectivos , Estados Unidos/epidemiologia
11.
ASAIO J ; 61(2): 144-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25396274

RESUMO

Successful long-term use of the HeartMate II (HM II) left ventricular assist device has become commonplace but may be complicated by mechanical failure, infection, or thrombosis necessitating device exchange (DE). A subcostal approach to device exchange with motor exchange only is less traumatic, but long-term outcomes have not been reported. A retrospective chart review of all patients who required HM II to HM II device exchange at our institution was conducted. Of the 232 HM II patients implanted between January 2008 and July 2013, 28 required 36 device exchanges during a follow-up of 33.72 ± 17.25 months. The Kaplan-Meier 1 year survival was 63% for sternotomy exchanges and 100% for subcostal exchanges. Twenty-one exchanges were performed for initial or recurring device thrombosis. Although there was no difference in the risk of subsequent thrombosis after subcostal versus sternotomy exchange, the overall risk of recurring device thrombosis after device exchange for the same was high (31%). HM II device exchange via the subcostal approach has excellent short- and long-term outcomes. Device exchange performed for thrombosis is associated with a high recurrence risk irrespective of surgical approach.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Adulto , Idoso , Falha de Equipamento , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Recidiva , Reoperação/efeitos adversos , Reoperação/métodos , Estudos Retrospectivos , Fatores de Risco , Trombose/etiologia , Resultado do Tratamento
12.
ASAIO J ; 61(4): 386-90, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25905496

RESUMO

It has been well established that patient self-testing (PST) of international normalized ratio (INR) using home monitoring devices increases the average therapeutic time and patient satisfaction. Long-term anticoagulation therapy with warfarin is used in patients with continuous-flow left ventricular assist device (CF-LVAD) to minimize the occurrence of thromboembolic events; however, PST devices have never been tested in patients with CF-LVADs. The purpose of this study was to determine the reliability of the PST device Alere INRatio 2 in patients supported with CF-LVADs. A correlation study was performed in 50 patients with CF-LVAD who were on stable warfarin therapy for a minimum of 3 weeks. Simultaneous INR values were determined from capillary whole blood samples using the Alere PST device and venous blood samples processed in the core laboratory at Columbia University Medical Center. There was a moderate correlation between the venous and the capillary INR values with a correlation coefficient of 0.83. The median difference between the methods was 0.39, with 44 of 50 patients recording higher INRs with Alere. Results remained unchanged after adjusting for use of amiodarone, abnormal hematocrit and liver enzymes, creatinine, and thyroid-stimulating hormone. Point of care testing with Alere correlates moderately well but consistently overestimates INR when compared with conventional laboratory testing in patients with CF-LVAD.


Assuntos
Coeficiente Internacional Normatizado/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Tempo de Protrombina/instrumentação , Autocuidado/métodos , Adulto , Idoso , Anticoagulantes/uso terapêutico , Feminino , Coração Auxiliar , Humanos , Coeficiente Internacional Normatizado/normas , Laboratórios Hospitalares/normas , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito/normas , Reprodutibilidade dos Testes , Autocuidado/normas , Varfarina/uso terapêutico
14.
J Heart Lung Transplant ; 33(11): 1119-25, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25085498

RESUMO

BACKGROUND: Mechanical support leads to an increased risk of both bleeding and thrombotic events, but little is known about the risk of device support in patients with a baseline predisposition to these events. The aim of this study was to examine outcomes among patients with baseline hematologic conditions who underwent continuous-flow LVAD implantation (CF-LVAD). METHODS: We retrospectively reviewed records of 286 patients who underwent CF-LVAD implantation at the Columbia University Medical Center between April 2008 and December 2013. Patients diagnosed with the following hematologic conditions were enrolled: idiopathic thrombocytopenic purpura (ITP); Factor V Leiden; elevated Factor VIII; heparin-induced thrombocytopenia (HIT); or undefined hypercoagulable state. RESULTS: Of the 286 CF-LVAD patients implanted during the study period, 12 were considered to have a significant hematologic condition predisposing them to either bleeding or thrombotic events. The study included 5 patients with ITP, 1 with Factor V Leiden, 1 with elevated Factor VIII, 2 with HIT and 3 patients with undefined hypercoagulable state. Patients were supported for a total of 168.46 months, with a median of 10.76 months (IQR 4.78 to 21.36 months). There was a high frequency of thrombotic (0.57 event per patient-year), neurologic (0.36 event per patient-year) and bleeding (0.64 event per patient-year). Actuarial survival rates at 6 and 12 months were 81.8%, but fell to 49% at 2 years. CONCLUSIONS: Patients with a history of prior hematologic conditions are at high risk for bleeding, thrombotic and neurologic events during device support, leading to early mortality. This case series questions the benefit of CF-LVAD in these patients and the appropriate management with regard to anti-coagulation. Further studies on the outcomes of these patients are warranted.


Assuntos
Coração Auxiliar , Doenças Hematológicas/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Período Pré-Operatório , Estudos Retrospectivos , Trombose/epidemiologia , Trombose/etiologia , Trombose/mortalidade
15.
J Cardiovasc Transl Res ; 7(2): 156-64, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24420915

RESUMO

In fulminant myocarditis complicated by cardiogenic shock, early mechanical circulatory support (MCS) may prevent cardiomyopathy and death. We sought to examine the outcomes of patients with fulminant myocarditis supported with MCS. A retrospective review of patients with acute cardiogenic shock treated with MCS from 2007 to 2013 was conducted, and patients with a diagnosis of fulminant myocarditis were included in this series. At our center, 260 patients received MCS for acute cardiogenic shock, and 11 were implanted for fulminant myocarditis. Eight received the Centrimag biventricular assist device (BIVAD), and three received veno-arterial extracorporeal membrane oxygenator (VA ECMO), though 1 VA ECMO-supported patient was transitioned to BIVAD due to refractory shock. The mean acute support time was 14.7 ± 4.4 days. Two patients required long-term left ventricular assist devices and were further supported for 55 and 112 days. Eight patients recovered with a mean ejection fraction of 54 ± 7 %, and one was successfully transplanted. Eight patients survived to discharge (73 %) with mean follow-up: 292.6 ± 306.8 days. All three deaths were due to neurologic complications. MCS should be considered in patients with fulminant myocarditis complicated by shock. With aggressive medical therapy, early utilization of MCS carries promising outcomes.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Miocardite/terapia , Choque Cardiogênico/terapia , Adulto , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/complicações , Miocardite/diagnóstico , Miocardite/mortalidade , Miocardite/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Adulto Jovem
16.
ASAIO J ; 60(3): 311-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24614361

RESUMO

Ventricular arrhythmias (VAs) are common after implantation of a left ventricular assist device (LVAD) and in a subset of patients may be refractory to medication. Morbidity from VA in this population includes right ventricular failure (RVF). We sought to evaluate the efficacy of catheter ablation for VA in patients with LVAD. A retrospective analysis of patients supported by continuous-flow LVAD referred for catheter ablation of ventricular tachycardia (VT) between 2008 and the present was performed. Seven patients were referred for VT ablation an average of 236 ± 292 days after LVAD implantation. Three patients (42.9%) developed RVF in the setting of intractable arrhythmias. A transfemoral approach was used for six patients (85.7%) and an epicardial for one patient (14.3%). The clinical VT was inducible and successfully ablated in six patients (85.7%). The location of these arrhythmias was apical in three cases (42.9%). A total of 13 VTs were ablated in seven patients. Although the majority had reduction in VA frequency, recurrent VAs were observed in six patients (85.7%). One patient (14.3%) experienced a bleeding complication after the procedure. For patients with a high VA burden after LVAD implantation, VT ablation is safe and feasible, but VA frequently recurs.


Assuntos
Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Taquicardia Ventricular/terapia , Idoso , Desfibriladores Implantáveis , Eletrofisiologia , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Hemorragia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
17.
J Invasive Cardiol ; 23(9): 359-62, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21891805

RESUMO

PURPOSE: Revascularization of lower extremity chronic total occlusions (CTOs) is technically challenging. The Crosser® recanalization catheter was designed to facilitate distal vessel intraluminal entry that is both rapid and safe. We present our experience with the Crosser device as primary therapy for peripheral CTOs. METHODS: Subjects undergoing evaluation for arterial insufficiency at our institution between 2008-2010 who were noted to have a CTO in the lower extremity by duplex ultrasonography and who subsequently underwent Crosser recanalization were enrolled. Clinical characteristics, ankle-brachial indices, Rutherford-Becker symptom category, and angiographic CTO parameters were collected. Primary technical success was intraluminal delivery of the guidewire into the distal vessel solely by the Crosser device. Secondary technical success was assisted delivery using the Outback LTD® re-entry device. Safety endpoints were the occurrence of dissections, thromboembolism, and perforations related to the Crosser device. Statistical analysis was performed to find independent predictors for failure to achieve Crosser recanalization. RESULTS: Fifty-six subjects with 73 CTOs were enrolled. The mean Crosser use time was 17.6 ± 12.7 minutes. The overall primary and secondary technical success rates for Crosser recanalization were 76.7% and 87.7%, respectively. Technical success was highest for CTOs located in the aorto-iliac (90.0%) and tibial (95.2%) arterial segments. There were no perforations related to the Crosser device. For successful cases, the mean ABI improved significantly from pre- to post-intervention (0.57 ± 0.13 to 0.89 ± 0.15, p < 0.001). The only predictors for failure were lesion length longer than 100 mm (p = 0.04) and calcification within 10 mm of the exit cap (p = 0.02). CONCLUSION: The Crosser device is safe and shows excellent efficacy in facilitating guidewire distal lumen entry, especially for aorto-iliac and tibial occlusions. The technical success rate for the femoral and popliteal occlusions is comparable to those reported with other recanalization techniques.


Assuntos
Angioplastia com Balão/instrumentação , Índice Tornozelo-Braço , Artéria Femoral , Doença Arterial Periférica/terapia , Idoso , Angioplastia com Balão/métodos , Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Estudos de Viabilidade , Feminino , Indicadores Básicos de Saúde , Heparina/uso terapêutico , Hirudinas , Humanos , Masculino , Análise Multivariada , Fragmentos de Peptídeos/uso terapêutico , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/patologia , Proteínas Recombinantes/uso terapêutico
18.
Vasc Health Risk Manag ; 5(3): 527-32, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19590587

RESUMO

OBJECTIVE: The immediate effects of transradial access on the radial artery wall are unknown. In this study we sought to assess the histological changes induced by catheterization on the radial artery. METHODS: Thirty-four patients undergoing coronary artery bypass grafting (CABG) had radial arteries harvested to serve as bypass conduits. The proximal and distal ends of the radial artery conduits were sectioned and embedded in paraffin. Both ends of all specimens were evaluated by a blinded pathologist for intimal hyperplasia, medial inflammation, medial calcification, periarterial tissue or fat necrosis, adventitial inflammation, adventitial necrosis, and adventitial neovascularization. Fisher's exact test was used for statistical analysis. RESULTS: Fifteen previously catheterized radial arteries (TRA group) were compared with 19 noncatheterized arteries (NCA group). The distal ends of the TRA group showed significantly more intimal hyperplasia (73.3% vs 21.1%; p = 0.03), periarterial tissue or fat necrosis (26% vs 0%; p = 0.02), and more adventitial inflammation (33.3% vs 0%; p = 0.01) than the distal ends of the NCA group. The distal ends of the TRA group also showed significantly more intimal hyperplasia (73.3% vs 26.6%; p = 0.03) and adventitial inflammation (33.3% vs 0%; p = 0.01) than the proximal ends of the same arteries. There were no histological differences in the proximal ends of the two groups. CONCLUSION: Transradial catheterization induces significant histological changes suggestive of radial artery injury limited to the puncture site in the form of intimal hyperplasia, medial inflammation, and tissue necrosis. Both the proximal and distal ends of the radial artery show a spectrum of atherosclerotic changes independent of its use for transradial catheterization.


Assuntos
Cateterismo Periférico/efeitos adversos , Artéria Radial/patologia , Túnica Íntima/patologia , Túnica Média/patologia , Adulto , Idoso , Aterosclerose/patologia , Calcinose/patologia , Tecido Conjuntivo/patologia , Ponte de Artéria Coronária , Feminino , Humanos , Hiperplasia , Inflamação/patologia , Masculino , Pessoa de Meia-Idade , Necrose , Punções , Artéria Radial/lesões , Artéria Radial/cirurgia , Túnica Íntima/lesões , Túnica Média/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA