Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Bioanalysis ; 14(10): 725-735, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35642540

RESUMO

Background: The development of immunogenicity assays for clinical drug candidates targeting soluble proteins is challenging when the soluble target might produce either false-positive or false-negative signals in bridging anti-drug antibody screening assays. A generic soluble target removal protocol that uses a pH-dependent depletion was evaluated. Results: An anti-drug antibody bridging assay with a pH-dependent soluble target depletion step was successfully developed. Endogenous target levels of ∼600 nM could be depleted below 8 pM. The assay was highly drug tolerant and met regulatory requirements. Conclusion: A reagent-independent target depletion protocol can be used for immunogenicity testing in the presence of a soluble target. The generic protocol circumvents common depletion or masking protocols.


Assuntos
Anticorpos , Imunoensaio/métodos , Indicadores e Reagentes
2.
Bioanalysis ; 8(8): 807-14, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26975340

RESUMO

During development of biotherapeutics, availability of specific assay reagents is usually limited. The possibility to switch from one ligand binding assay technology to another, while using the same reagents, would be desirable. Here, we report on an Alexa647(®)-labeled monoclonal antibody against digoxigenin (mAb-Alexa647(®)) that enables the detection of digoxigenylated analyte-specific ELISA reagents by Gyrolab(™). In an analysis of non-monoclonal antibody (mAb) and mAb drugs, this approach maintained the dynamic range, accuracy and precision of the standard Gyrolab™ approach using analyte-specific Alexa647(®)-labeled Ab. In a rat PK study, results of our approach, standard Gyrolab™ and ELISA were comparable, with difference values within the incurred sample reanalysis acceptance criteria. Therefore, mAb-Alexa647(®) enables an easy switch between ELISA and Gyrolab™, providing an effective way to benefit from both platforms.


Assuntos
Anticorpos Monoclonais/sangue , Digoxigenina/imunologia , Ensaio de Imunoadsorção Enzimática , Imunoensaio , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacocinética , Carbocianinas/química , Meia-Vida , Ratos , Kit de Reagentes para Diagnóstico
3.
Bioanalysis ; 8(20): 2135-45, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27582032

RESUMO

AIM: Bridging immunoassays for the detection of antidrug antibodies (ADAs) are limited to detection of bivalent molecules and are prone to interference by drug and soluble targets. Hence, alternative approaches for ADA detection are desired. Materials & methods: A novel ADA assay with secondary Fc detection using human soluble Fcγ receptor I (hsFcγRI) was established and compared with standard bridging assay. RESULTS: Both assays showed consistent results in human and cynomolgus monkey samples. In contrast to the bridging assay, the hsFcγRI-based assay was insensitive to the presence of oligomeric targets and appeared to have better drug tolerance. CONCLUSION: The hsFcγRI-based ADA assay can serve as alternative screening assay or as orthogonal confirmation method for preclinical and clinical immunogenicity testing of IgG therapeutics lacking Fc effector functions.


Assuntos
Anticorpos Anti-Idiotípicos/sangue , Anticorpos Monoclonais/imunologia , Imunoensaio , Receptores de IgG/metabolismo , Animais , Anticorpos Anti-Idiotípicos/metabolismo , Complexo Antígeno-Anticorpo , Feminino , Humanos , Macaca fascicularis , Masculino , Ligação Proteica , Receptores de Citocinas/imunologia , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/metabolismo , Ressonância de Plasmônio de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA