Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Environ Sci Technol ; 53(13): 7866-7876, 2019 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-31150216

RESUMO

This study characterized emissions from IQOS, a heated tobacco product promoted as a less harmful alternative to cigarettes. Consumable tobacco plugs were analyzed by headspace GC/MS to assess the influence of heating temperature on the emission profile. Yields of major chemical constituents increased from 4.1 mg per unit at 180 °C to 6.2 mg at 200 °C, and 10.5 mg at 220 °C. The Health Canada Intense smoking regime was used to operate IQOS in an environmental chamber, quantifying 33 volatile organic compounds in mainstream and sidestream emissions. Aldehydes, nitrogenated species, and aromatic species were found, along with other harmful and potentially harmful compounds. Compared with combustion cigarettes, IQOS yields were in most cases 1-2 orders of magnitude lower. However, yields were closer to, and sometimes higher than electronic cigarettes. Predicted users' daily average intake of benzene, formaldehyde, acetaldehyde and acrolein were 39 µg, 32 µg, 2.2 mg and 71 µg, respectively. Indoor air concentrations were estimated for commonly encountered scenarios, with acrolein levels of concern (over 0.35 µg m-3) derived from IQOS used in homes and public spaces. Heated tobacco products are a weaker indoor pollution source than conventional cigarettes, but their impacts are neither negligible nor yet fully understood.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Poluição por Fumaça de Tabaco , Compostos Orgânicos Voláteis , Canadá , Nicotiana
2.
J Environ Manage ; 207: 70-79, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29154010

RESUMO

Reactive Black 5, RB5, has been used as a model azo dye to evaluate the removal efficiency of sorption on Macrocystis pyrifera biomass (Mpyr) and commercial zerovalent iron nanoparticles (nZVI) in individual and combined treatments. The best conditions for the treatment with the isolated materials were first determined, and then, in series and combined treatments were performed under these conditions, achieving removal efficiencies higher than 80% of the initial dye concentration. Strengths and weaknesses of all removal strategies (individual, in series and combined) are analyzed regarding the application on real effluents. Mpyr efficiently adsorbed RB5, but also increased the total organic content by partial dissolution of components of the algal biomass. Removal experiments with commercial nZVI were also efficient but liberated Fe to the solution, and sulfanilic acid was observed after the treatment as a product of RB5 degradation. In contrast, after the Mpyr treatment, no sulfanilic acid was detected, suggesting that sulfanilic acid is efficiently adsorbed by the biomass. The best condition was the integrated use of Mpyr and nZVI, with a remarkable removal efficiency (69-80%) obtained after only 1 h of treatment. Finally, nZVI were successfully immobilized in Mpyr, and the hybrid material was used to remove RB5 in continuous flow experiments at pH 3, obtaining a removal capacity of 39.9 mg RB5 g-1 after a total processed volume of 630 mL of [RB5]0 = 100 mg L-1.


Assuntos
Macrocystis , Nanopartículas , Naftalenossulfonatos , Purificação da Água , Biomassa , Ferro , Poluentes Químicos da Água
3.
Environ Sci Technol ; 51(16): 9271-9279, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28766331

RESUMO

E-cigarettes likely represent a lower risk to health than traditional combustion cigarettes, but they are not innocuous. Recently reported emission rates of potentially harmful compounds were used to assess intake and predict health impacts for vapers and bystanders exposed passively. Vapers' toxicant intake was calculated for scenarios in which different e-liquids were used with various vaporizers, battery power settings and vaping regimes. For a high rate of 250 puff day-1 using a typical vaping regime and popular tank devices with battery voltages from 3.8 to 4.8 V, users were predicted to inhale formaldehyde (up to 49 mg day-1), acrolein (up to 10 mg day-1) and diacetyl (up to 0.5 mg day-1), at levels that exceeded U.S. occupational limits. Formaldehyde intake from 100 daily puffs was higher than the amount inhaled by a smoker consuming 10 conventional cigarettes per day. Secondhand exposures were predicted for two typical indoor scenarios: a home and a bar. Contributions from vaping to air pollutant concentrations in the home did not exceed the California OEHHA 8-h reference exposure levels (RELs), except when a high emitting device was used at 4.8 V. In that extreme scenario, the contributions from vaping amounted to as much as 12 µg m-3 formaldehyde and 2.6 µg m-3 acrolein. Pollutant concentrations in bars were modeled using indoor volumes, air exchange rates and the number of hourly users reported in the literature for U.S. bars in which smoking was allowed. Predicted contributions to indoor air levels were higher than those in the residential scenario. Formaldehyde (on average 135 µg m-3) and acrolein (28 µg m-3) exceeded the acute 1-h exposure REL for the highest emitting vaporizer/voltage combination. Predictions for these compounds also exceeded the 8-h REL in several bars when less intense vaping conditions were considered. Benzene concentrations in a few bars approached the 8-h REL, and diacetyl levels were close to the lower limit for occupational exposures. The integrated health damage from passive vaping was derived by computing disability-adjusted life years (DALYs) lost due to exposure to secondhand vapor. Acrolein was the dominant contributor to the aggregate harm. DALYs for the various device/voltage combinations were lower than-or comparable to-those estimated for exposures to secondhand and thirdhand tobacco smoke.


Assuntos
Poluentes Atmosféricos/análise , Sistemas Eletrônicos de Liberação de Nicotina , Formaldeído/análise , Poluição por Fumaça de Tabaco/análise , Poluição do Ar em Ambientes Fechados/análise , California , Substâncias Perigosas , Humanos , Risco
4.
Environ Sci Technol ; 50(17): 9644-51, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27461870

RESUMO

Use of electronic cigarettes has grown exponentially over the past few years, raising concerns about harmful emissions. This study quantified potentially toxic compounds in the vapor and identified key parameters affecting emissions. Six principal constituents in three different refill "e-liquids" were propylene glycol (PG), glycerin, nicotine, ethanol, acetol, and propylene oxide. The latter, with mass concentrations of 0.4-0.6%, is a possible carcinogen and respiratory irritant. Aerosols generated with vaporizers contained up to 31 compounds, including nicotine, nicotyrine, formaldehyde, acetaldehyde, glycidol, acrolein, acetol, and diacetyl. Glycidol is a probable carcinogen not previously identified in the vapor, and acrolein is a powerful irritant. Emission rates ranged from tens to thousands of nanograms of toxicants per milligram of e-liquid vaporized, and they were significantly higher for a single-coil vs a double-coil vaporizer (by up to an order of magnitude for aldehydes). By increasing the voltage applied to a single-coil device from 3.3 to 4.8 V, the mass of e-liquid consumed doubled from 3.7 to 7.5 mg puff(-1) and the total aldehyde emission rates tripled from 53 to 165 µg puff(-1), with acrolein rates growing by a factor of 10. Aldehyde emissions increased by more than 60% after the device was reused several times, likely due to the buildup of polymerization byproducts that degraded upon heating. These findings suggest that thermal degradation byproducts are formed during vapor generation. Glycidol and acrolein were primarily produced by glycerin degradation. Acetol and 2-propen-1-ol were produced mostly from PG, while other compounds (e.g., formaldehyde) originated from both. Because emissions originate from reaction of the most common e-liquid constituents (solvents), harmful emissions are expected to be ubiquitous when e-cigarette vapor is present.


Assuntos
Aerossóis , Sistemas Eletrônicos de Liberação de Nicotina , Acetaldeído , Formaldeído , Nicotina
5.
Talanta ; 138: 20-27, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25863366

RESUMO

Reactive oxygen species (ROS), such as free radicals and peroxides, are environmental trace pollutants potentially associated with asthma and airways inflammation. These compounds are often not detected in indoor air due to sampling and analytical limitations. This study developed and validated an experimental method to sample, identify and quantify ROS in indoor air using fluorescent probes. Tests were carried out simultaneously using three different probes: 2',7'-dichlorofluorescin (DCFH) to detect a broad range of ROS, Amplex ultra Red® (AuR) to detect peroxides, and terephthalic acid (TPA) to detect hydroxyl radicals (HO(•)). For each test, air samples were collected using two impingers in series kept in an ice bath, containing each 10 mL of 50 mM phosphate buffer at pH 7.2. In tests with TPA, that probe was also added to the buffer prior to sampling; in the other two tests, probes and additional reactants were added immediately after sampling. The concentration of fluorescent byproducts was determined fluorometrically. Calibration curves were developed by reacting DCFH and AuR with known amounts of H2O2, and using known amounts of 2-hydroxyterephthalic acid (HTPA) for TPA. Low detection limits (9-13 nM) and quantification limits (18-22 nM) were determined for all three probes, which presented a linear response in the range 10-500 nM for AuR and TPA, and 100-2000 nM for DCFH. High collection efficiency (CE) and recovery efficiency (RE) were observed for DCFH (CE=RE=100%) and AuR (CE=100%; RE=73%) by sampling from a laboratory-developed gas phase H2O2 generator. Interference of co-occurring ozone was evaluated and quantified for the three probes by sampling from the outlet of an ozone generator. The method was demonstrated by sampling air emitted by two portable air cleaners: a strong ozone generator (AC1) and a plasma generator (AC2). High ozone levels emitted by AC1 did not allow for simultaneous determination of ROS levels due to high background levels associated with ozone decomposition in the buffer. However, emitted ROS were quantified at the outlet of AC2 using two of the three probes. With AuR, the concentration of peroxides in air emitted by the air cleaner was 300 ppt of H2O2 equivalents. With TPA, the HO(•) concentration was 47 ppt. This method is best suited to quantify ROS in the presence of low ozone levels.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Corantes Fluorescentes/química , Peróxido de Hidrogênio/química , Ozônio/análise , Espécies Reativas de Oxigênio/análise , Fluoresceínas/química , Radical Hidroxila/química , Limite de Detecção , Ácidos Ftálicos/química
6.
J Phys Chem Lett ; 4(3): 536-41, 2013 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26281751

RESUMO

Self-cleaning surfaces containing TiO2 nanoparticles have been postulated to efficiently remove NOx from the atmosphere. However, UV irradiation of NOx adsorbed on TiO2 also was shown to form harmful gas-phase byproducts such as HONO and N2O that may limit their depolluting potential. Ambient pressure XPS was used to study surface and gas-phase species formed during adsorption of NO2 on TiO2 and subsequent UV irradiation at λ = 365 nm. It is shown here that NO3(-), adsorbed on TiO2 as a byproduct of NO2 disproportionation, was quantitatively converted to surface NO2 and other reduced nitrogenated species under UV irradiation in the absence of moisture. When water vapor was present, a faster NO3(-) conversion occurred, leading to a net loss of surface-bound nitrogenated species. Strongly adsorbed NO3(-) in the vicinity of coadsorbed K(+) cations was stable under UV light, leading to an efficient capture of nitrogenated compounds.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA