Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 26(2): 101056, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971502

RESUMO

BACKGROUND: The presence of mitral annulus disjunction (MAD) has been considered a high-risk feature for sudden cardiac death based on selected study populations. We aimed to assess the prevalence of MAD in consecutive patients undergoing clinically indicated cardiovascular magnetic resonance (CMR), its association with ventricular arrhythmias, mitral valve prolapse (MVP), and other CMR features. METHODS: This single-center retrospective study included consecutive patients referred to CMR at our institution between June 2021 and November 2021. MAD was defined as a ≥1 mm displacement between the left atrial wall-mitral valve leaflet junction and the left ventricular wall during end-systole. MAD extent was defined as the maximum longitudinal displacement. Associates of MAD were evaluated at univariable and multivariable regression analysis. The study endpoint, a composite of (aborted) sudden cardiac death, unexplained syncope, and sustained ventricular tachycardia, was evaluated at a 12-month follow-up. RESULTS: Four hundred and forty-one patients 55 ± 18 years, 267/441 (61%) males) were included, and 29/441 (7%) had MVP. The prevalence of MAD ≥1 mm, 4 mm, and 6 mm was 214/441 (49%), 63/441 (14%), and 15/441 (3%), respectively. Patients with MVP showed a higher prevalence of MAD greater than 1 mm (26/29 (90%) vs 118/412 (46%)); p < 0.001), 4 mm (14/29 (48%) vs 49/412 (12%)); p < 0.001), and 6 mm (3/29 (10%) vs 12/412 (3%)); p = 0.03), and a greater MAD extent (4.2 mm, 3.0-5.7 mm vs 2.8 mm, 1.9-4.0 mm; p < 0.001) compared to patients without MVP. MVP was the only morpho-functional abnormality associated with MAD at multivariable analysis (p < 0.001). A high burden of ventricular ectopic beats at baseline Holter-electrocardiogram was associated with MAD ≥4 mm and MAD extent (p < 0.05). The presence of MAD ≥1 mm (0.9% vs 1.8%; p = 0.46), MAD ≥4 mm (1.6% vs 1.3%; p = 0.87), or MVP (3.5% vs 1.2%; p = 0.32) were not associated with the study endpoint, whereas patients with MAD ≥6 mm showed a trend toward a higher likelihood of the study endpoint (6.7% vs 1.2%; p = 0.07). CONCLUSION: MAD of limited severity was common in consecutive patients undergoing CMR. Patients with MVP showed higher prevalence and greater extent of MAD. Extended MAD was rarer and showed association with ventricular arrhythmias at baseline. The mid-term prognosis of MAD seems benign; however, prospective studies are warranted to search for potential "malignant MAD extents" to improve patients' risk stratification.

2.
J Comput Assist Tomogr ; 48(2): 217-221, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37621087

RESUMO

OBJECTIVE: The increasing number of coronary computed tomography angiography (CCTA) requests raised concerns about dose exposure. New dose reduction strategies based on artificial intelligence have been proposed to overcome limitations of iterative reconstruction (IR) algorithms. Our prospective study sought to explore the added value of deep-learning image reconstruction (DLIR) in comparison with a hybrid IR algorithm (adaptive statistical iterative reconstruction-veo [ASiR-V]) in CCTA, even in clinical challenging scenarios, as obesity, heavily calcified vessels and coronary stents. METHODS: We prospectively included 103 consecutive patients who underwent CCTA. Data sets were reconstructed with ASiR-V and DLIR. For each reconstruction signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) was calculated, and qualitative assessment was made with a four-point Likert scale by two independent and blinded radiologists with different expertise. RESULTS: Both SNR and CNR were significantly higher in DLIR (SNR-DLIR median value [interquartile range] of 13.89 [11.06-16.35] and SNR-ASiR-V 25.42 [22.46-32.22], P < 0.001; CNR-DLIR 16.84 [9.83-27.08] vs CNR-ASiR-V 10.09 [5.69-13.5], P < 0.001).Median qualitative score was 4 for DLIR images versus 3 for ASiR-V ( P < 0.001), with a good interreader reliability [intraclass correlation coefficient(2,1)e intraclass correlation coefficient(3,1) 0.60 for DLIR and 0.62 and 0.73 for ASiR-V].In the obese and in the "calcifications and stents" groups, DLIR showed significantly higher values of SNR (24.23 vs 11.11, P < 0.001 and 24.55 vs 14.09, P < 0.001, respectively) and CNR (16.08 vs 8.04, P = 0.008 and 17.31 vs 10.14, P = 0.003) and image quality. CONCLUSIONS: Deep-learning image reconstruction in CCTA allows better SNR, CNR, and qualitative assessment than ASiR-V, with an added value in the most challenging clinical scenarios.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado Profundo , Humanos , Inteligência Artificial , Estudos Prospectivos , Reprodutibilidade dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Algoritmos , Processamento de Imagem Assistida por Computador
3.
Sensors (Basel) ; 24(16)2024 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-39204898

RESUMO

Astronomy is entering an unprecedented era of big-data science, driven by missions like the ESA's Gaia telescope, which aims to map the Milky Way in three dimensions. Gaia's vast dataset presents a monumental challenge for traditional analysis methods. The sheer scale of this data exceeds the capabilities of manual exploration, necessitating the utilization of advanced computational techniques. In response to this challenge, we developed a novel approach leveraging deep learning to estimate the metallicity of fundamental mode (ab-type) RR Lyrae stars from their light curves in the Gaia optical G-band. Our study explores applying deep-learning techniques, particularly advanced neural-network architectures, in predicting photometric metallicity from time-series data. Our deep-learning models demonstrated notable predictive performance, with a low mean absolute error (MAE) of 0.0565, the root mean square error (RMSE) of 0.0765, and a high R2 regression performance of 0.9401, measured by cross-validation. The weighted mean absolute error (wMAE) is 0.0563, while the weighted root mean square error (wRMSE) is 0.0763. These results showcase the effectiveness of our approach in accurately estimating metallicity values. Our work underscores the importance of deep learning in astronomical research, particularly with large datasets from missions like Gaia. By harnessing the power of deep-learning methods, we can provide precision in analyzing vast datasets, contributing to more precise and comprehensive insights into complex astronomical phenomena.

4.
Radiol Med ; 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39256298

RESUMO

PURPOSE: The objective of this study was to investigate the role of myocardial perfusion imaging (MPI) stress tests using stress cardiac magnetic resonance (sCMR) and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in non-cardiac surgery (NCS) pre-operatory management. MATERIALS AND METHODS: This monocentric retrospective study enrolled patients with coronary artery disease or a minimum of two cardiovascular risk factors undergoing intermediate-to-high-risk non-cardiac surgeries. The primary composite endpoint comprised cardiac death, cardiogenic shock, acute coronary syndromes (ACS), and cardiogenic pulmonary edema occurring within 30 days after surgery, while the secondary endpoint was ACS. RESULTS: A total of 1590 patients were enrolled; among them, 669 underwent a MPI stress test strategy (sCMR: 287, SPECT-MPI: 382). The incidence of 30-day cardiac events was lower in the stress-tested group compared to the non-stress-tested group (1.2% vs. 3.4%; p 0.006). Adopting a stress test strategy showed a significant reduction in the risk of the composite endpoint (OR: 0.33, 95% CI: 0.15-0.76, p 0.009) and ACS (OR: 0.41, 95% CI: 0.17-0.98, p 0.046) at multivariable analysis, with similar cardiac events rate between stress CMR and SPECT (1.1% vs. 1.3%, p 0.756). Stress CMR showed a greater accuracy to predict coronary artery revascularizations (sCMR c-statistic: 0.95, ischemic cut-point: 5.5%; SPECT c-statistic: 0.85, ischemic cut-point: 7.5%). CONCLUSION: Stress test strategy is related to a lower occurrence of cardiac events in high-risk patients scheduled for intermediate-to-high-risk non-cardiac surgeries. Both sCMR and SPECT-MPI comparably reduce the likelihood of cardiac complications, albeit sCMR offers greater accuracy in predicting coronary artery revascularization.

5.
Medicina (Kaunas) ; 60(5)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38792874

RESUMO

Risk stratification for malignant ventricular arrhythmias and sudden cardiac death is a daunting task for physicians in daily practice. Multiparametric mapping sequences obtained via cardiovascular magnetic resonance imaging can improve the risk stratification for malignant ventricular arrhythmias by unveiling the presence of pathophysiological pro-arrhythmogenic processes. However, their employment in clinical practice is still restricted. The present review explores the current evidence supporting the association between mapping abnormalities and the risk of ventricular arrhythmias in several cardiovascular diseases. The key message is that further clinical studies are needed to test the additional value of mapping techniques beyond conventional cardiovascular magnetic resonance imaging for selecting patients eligible for an implantable cardioverter defibrillator.


Assuntos
Arritmias Cardíacas , Morte Súbita Cardíaca , Humanos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Arritmias Cardíacas/complicações , Imageamento por Ressonância Magnética/métodos , Desfibriladores Implantáveis , Taquicardia Ventricular/complicações
6.
Radiology ; 306(1): 112-121, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098639

RESUMO

Background Patients with mitral valve prolapse (MVP) may develop adverse outcomes even in the absence of mitral regurgitation or left ventricular (LV) dysfunction. Purpose To investigate the prognostic value of mitral annulus disjunction (MAD) and myocardial fibrosis at late gadolinium enhancement (LGE) cardiac MRI in patients with MVP without moderate-to-severe mitral regurgitation or LV dysfunction. Materials and Methods In this longitudinal retrospective study, 118 144 cardiac MRI studies were evaluated between October 2007 and June 2020 at 15 European tertiary medical centers. Follow-up was from the date of cardiac MRI examination to June 2020; the minimum and maximum follow-up intervals were 6 months and 156 months, respectively. Patients were excluded if at least one of the following conditions was present: cardiomyopathy, LV ejection fraction less than 40%, ischemic heart disease, congenital heart disease, inflammatory heart disease, moderate or worse mitral regurgitation, participation in competitive sport, or electrocardiogram suggestive of channelopathies. In the remainder, cardiac MRI studies were reanalyzed, and patients were included if they were aged 18 years or older, MVP was diagnosed at cardiac MRI, and clinical information and electrocardiogram monitoring were available within 3 months from cardiac MRI examination. The end point was a composite of adverse outcomes: sustained ventricular tachycardia (VT), sudden cardiac death (SCD), or unexplained syncope. Multivariable Cox regression analysis was performed. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 women) were included. Over a median follow-up of 3.3 years, 18 patients (4%) reached the study end point. LGE presence (hazard ratio, 4.2 [95% CI: 1.5, 11.9]; P = .006) and extent (hazard ratio, 1.2 per 1% increase [95% CI: 1.1, 1.4]; P = .006), but not MAD presence (P = .89), were associated with clinical outcome. LGE presence had incremental prognostic value over MVP severity and sustained VT and aborted SCD at baseline (area under the receiver operating characteristic curve, 0.70 vs 0.62; P = .03). Conclusion In contrast to mitral annulus disjunction, myocardial fibrosis determined according to late gadolinium enhancement at cardiac MRI was associated with adverse outcome in patients with mitral valve prolapse without moderate-to-severe mitral regurgitation or left ventricular dysfunction. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Gerber in this issue.


Assuntos
Cardiomiopatias , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/complicações , Estudos Retrospectivos , Meios de Contraste , Gadolínio , Valva Mitral , Imageamento por Ressonância Magnética , Fibrose , Morte Súbita Cardíaca
7.
Medicina (Kaunas) ; 60(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38256331

RESUMO

A cardiac lesion detected at ultrasonography might turn out to be a normal structure, a benign tumor or rarely a malignancy, and lesion characterization is very important to appropriately manage the lesion itself. The exact relationship of the mass with coronary arteries and the knowledge of possible concomitant coronary artery disease are necessary preoperative information. Moreover, the increasingly performed coronary CT angiography to evaluate non-invasively coronary artery disease leads to a rising number of incidental findings. Therefore, CT and MRI are frequently performed imaging modalities when echocardiography is deemed insufficient to evaluate a lesion. A brief comprehensive overview about diagnostic radiological imaging and the clinical background of cardiac masses and pseudomasses is reported.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Angiografia Coronária
8.
Eur J Orthop Surg Traumatol ; 33(4): 1315-1328, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35643948

RESUMO

BACKGROUND: The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. METHODS: The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient's Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). RESULTS: The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. CONCLUSIONS: Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. LEVEL OF EVIDENCE: LEVEL II: Comparative study.


Assuntos
Hipersensibilidade , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Ligas , Hipersensibilidade/etiologia , Resultado do Tratamento , Estudos Retrospectivos
9.
Rev Cardiovasc Med ; 23(2): 76, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35229567

RESUMO

Tricuspid regurgitation (TR) has a considerable prevalence in the overall population, that further increases in selected categories of patients. Three morphologic types of TR prevail, namely primary, secondary and atrial TR, mostly, but not always, occurring in different subsets of patients. Recent evidences demonstrate a negative impact of TR on outcomes, irrespective of etiology and even when less than severe in grading. Unfortunately, current surgical standards are void of strong prospective evidence of positive impact on clinical outcomes. While on one hand recent advances in diagnosis and risk stratification of patients with TR are shedding light onto the population that may benefit from intervention and its appropriate timing, on the other hand the arrival on stage of percutaneous treatment options is widening even more the therapeutic options for such population. In this review we will address and discuss the available evidence on the prognostic impact of TR in different clinical contexts encountered in practice.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Prognóstico , Estudos Prospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/terapia
10.
Eur Radiol ; 32(7): 4352-4360, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35230520

RESUMO

OBJECTIVES: To assess clinical and cardiac magnetic resonance (CMR) imaging features of patients with peri-myocarditis following Coronavirus Disease 2019 (COVID-19) vaccination. METHODS: We retrospectively collected a case series of 27 patients who underwent CMR in the clinical suspect of heart inflammation following COVID-19 vaccination, from 16 large tertiary centers. Our patient's cohort was relatively young (36.6 ± 16.8 years), predominately included males (n = 25/27) with few comorbidities and covered a catchment area of approximately 8 million vaccinated patients. RESULTS: CMR revealed typical mid-subepicardial non-ischemic late gadolinium enhancement (LGE) in 23 cases and matched positively with CMR T2 criteria of myocarditis. In 7 cases, typical hallmarks of acute pericarditis were present. Short-term follow-up (median = 20 days) from presentation was uneventful for 25/27 patients and unavailable in two cases. CONCLUSIONS: While establishing a causal relationship between peri-myocardial inflammation and vaccine administration can be challenging, our clinical experience suggests that CMR should be performed for diagnosis confirmation and to drive clinical decision-making and follow-up. KEY POINTS: • Acute onset of dyspnea, palpitations, or acute and persisting chest pain after COVID-19 vaccination should raise the suspicion of possible myocarditis or pericarditis, and patients should seek immediate medical attention and treatment to help recovery and avoid complications. • In case of elevated troponin levels and/or relevant ECG changes, cardiac magnetic resonance should be considered as the best non-invasive diagnostic option to confirm the diagnosis of myocarditis or pericarditis and to drive clinical decision-making and follow-up.


Assuntos
COVID-19 , Miocardite , Pericardite , Arritmias Cardíacas , Vacinas contra COVID-19/efeitos adversos , Meios de Contraste/farmacologia , Gadolínio/farmacologia , Humanos , Inflamação , Imageamento por Ressonância Magnética , Masculino , Miocardite/diagnóstico por imagem , Miocardite/etiologia , Pericardite/diagnóstico por imagem , Pericardite/etiologia , Estudos Retrospectivos , Vacinação
11.
Sensors (Basel) ; 22(10)2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35632101

RESUMO

Studies and systems that are aimed at the identification of the presence of people within an indoor environment and the monitoring of their activities and flows have been receiving more attention in recent years, specifically since the beginning of the COVID-19 pandemic. This paper proposes an approach for people counting that is based on the use of cameras and Raspberry Pi platforms, together with an edge-based transfer learning framework that is enriched with specific image processing strategies, with the aim of this approach being adopted in different indoor environments without the need for tailored training phases. The system was deployed on a university campus, which was chosen as the case study. The proposed system was able to work in classrooms with different characteristics. This paper reports a proposed architecture that could make the system scalable and privacy compliant and the evaluation tests that were conducted in different types of classrooms, which demonstrate the feasibility of this approach. Overall, the system was able to count the number of people in classrooms with a maximum mean absolute error of 1.23.


Assuntos
COVID-19 , Pandemias , Humanos , Processamento de Imagem Assistida por Computador , Aprendizado de Máquina
12.
Rheumatology (Oxford) ; 59(8): 1938-1948, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31764972

RESUMO

OBJECTIVES: Cardiac rhythm disturbances constitute the most frequent cardiovascular cause of death in SSc. However, electrocardiographic findings are not a part of risk stratification in SSc. We aimed to translate 24 h Holter findings into a tangible risk prediction score using cardiovascular magnetic resonance. METHODS: The Scleroderma Arrhythmia Clinical Utility Study (SAnCtUS) was a prospective multicentre study including 150 consecutive SSc patients from eight European centres, assessed with 24 h Holter and cardiovascular magnetic resonance, including ventricular function, oedema (T2 ratio) and late gadolinium enhancement (%LGE). Laboratory/clinical parameters were included in multivariable corrections. A combined endpoint of sustained ventricular tachycardia requiring hospitalization and sudden cardiac death at a median (interquartile range) follow-up of 1 (1.0-1.4) year was generated. RESULTS: Only T2 ratio and %LGE were significant predictors of ventricular rhythm disturbances, but not of supraventricular rhythm disturbances, after multivariable correction and adjustment for multiple comparisons. Using decision-tree analysis, we created the SAnCtUS score, a four-category scoring system based on T2 ratio and %LGE, for identifying SSc patients at high risk of experiencing ventricular rhythm disturbance at baseline. Increasing SAnCtUS scores were associated with a greater disease and arrhythmic burden. All cases of non-sustained ventricular tachycardia (n = 7) occurred in patients with the highest SAnCtUS score (=4). Having a score of 4 conveyed a higher risk of reaching the combined endpoint in multivariable Cox regression compared with scores 1/2/3 [hazard ratio (95% CI): 3.86 (1.14, 13.04), P = 0.029] independently of left ventricular ejection fraction and baseline ventricular tachycardia occurrence. CONCLUSION: T2 ratio and %LGE had the greatest utility as independent predictors of rhythm disturbances in SSc patients.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Escleroderma Sistêmico/diagnóstico por imagem , Adulto , Idoso , Arritmias Cardíacas/etiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Escleroderma Sistêmico/complicações , Função Ventricular Esquerda
13.
Sensors (Basel) ; 20(19)2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-33003482

RESUMO

Urban noise is one of the most serious and underestimated environmental problems. According to the World Health Organization, noise pollution from traffic and other human activities, negatively impact the population health and life quality. Monitoring noise usually requires the use of professional and expensive instruments, called phonometers, able to accurately measure sound pressure levels. In many cases, phonometers are human-operated; therefore, periodic fine-granularity city-wide measurements are expensive. Recent advances in the Internet of Things (IoT) offer a window of opportunities for low-cost autonomous sound pressure meters. Such devices and platforms could enable fine time-space noise measurements throughout a city. Unfortunately, low-cost sound pressure sensors are inaccurate when compared with phonometers, experiencing a high variability in the measurements. In this paper, we present RaveGuard, an unmanned noise monitoring platform that exploits artificial intelligence strategies to improve the accuracy of low-cost devices. RaveGuard was initially deployed together with a professional phonometer for over two months in downtown Bologna, Italy, with the aim of collecting a large amount of precise noise pollution samples. The resulting datasets have been instrumental in designing InspectNoise, a library that can be exploited by IoT platforms, without the need of expensive phonometers, but obtaining a similar precision. In particular, we have applied supervised learning algorithms (adequately trained with our datasets) to reduce the accuracy gap between the professional phonometer and an IoT platform equipped with low-end devices and sensors. Results show that RaveGuard, combined with the InspectNoise library, achieves a 2.24% relative error compared to professional instruments, thus enabling low-cost unmanned city-wide noise monitoring.

16.
J Magn Reson Imaging ; 45(4): 1055-1067, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27571232

RESUMO

PURPOSE: To define reference values of cardiac volumes, dimensions, and new morpho-functional parameters normalized for age, gender, and body surface area by cine-bSSFP (balanced steady-state free-precession) magnetic resonance (MR). MATERIALS AND METHODS: We enrolled 308 healthy subjects subdivided by gender and by six age classes: class I, >15-20 years; class II, >20-30 years; class III, >30-40 years; class IV, >40-50 years; class V, >50-60 years; and class VI >60 years. Dimensional, volumetric and morpho-functional parameters of the left (LV) and right (RV) ventricles were measured using cine-bSSFP MRI at 1.5T. RESULTS: The LV and RV end-diastolic volume indexes (EDVi) were inversely related to age (P < 0.0001 r = -0.34 and P < 0.0001 r = -0.37, respectively). In addition, the LV mass index decreased with age (P = 0.0004, r = -0.21). The LV longitudinal shortening was not significantly different among groups: ≥15% in all populations (95% confidence interval [CI]: 16-31). The sphericity index measured in end-diastole was higher in females than in males (P < 0.03): the upper limit was 40% for males and 42% for females. The normality cutoff of LV global function index was ≥33% in males and ≥35% in females. The end-diastolic volume (EDV) of RV and LV was balanced (RV/LV ratio 0.85-1.15) without differences in the population. The LV EDV/mass was 1.0-1.8 in males and 1.0-2.1 in females. CONCLUSION: This study provides potential age- and gender-specific reference. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:1055-1067.


Assuntos
Volume Cardíaco/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Fatores Etários , Feminino , Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores Sexuais , Adulto Jovem
18.
Knee Surg Sports Traumatol Arthrosc ; 23(11): 3337-42, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25011643

RESUMO

PURPOSE: The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. METHODS: This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. RESULTS: Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. CONCLUSIONS: This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. CLINICAL RELEVANCE: A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Esponja de Gelatina Absorvível/administração & dosagem , Hemostáticos/administração & dosagem , Hemorragia Pós-Operatória/prevenção & controle , Trombina/administração & dosagem , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemoglobinas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/sangue , Hemorragia Pós-Operatória/etiologia , Estudos Prospectivos , Reoperação , Resultado do Tratamento
19.
Cureus ; 16(7): e65475, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39188467

RESUMO

Bleeding complications after pacemaker implantation pose risks, including infection and prolonged hospital stay. A case involving aortic intramural hematoma (IMH) arising from subclavian vein access during implantation and concomitant acute pulmonary embolism (PE) is presented. In the present case, IMH probably resulted from subclavian artery vasa vasorum trauma during vein puncture and guidewire advancement, leading to IMH and hemothorax. PE possibly stemmed from a prothrombotic state caused by the intervention and the IMH. Conservative management with serial CT scans was chosen due to hemodynamic stability and high surgical risk. IMH and PE resolution was confirmed at follow-up.

20.
Diagnostics (Basel) ; 14(15)2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39125558

RESUMO

BACKGROUND: Malignant neoplasms originating from or involving the mediastinum represent a diagnostic and therapeutic challenge when they are in contact with nearby cardiovascular structures. We aimed to test the diagnostic accuracy of cine-magnetic resonance imaging (cine-MRI) in detecting the infiltration of cardiovascular structures in cases with uncertain or equivocal findings from contrast-enhanced Computed Tomography (CT) scanning. METHODS: Fifty patients affected by tumors with a suspected invasion of mediastinal cardiovascular structures at the pre-operative chest CT scan stage underwent cine-MRI before surgery at our Institution. Intraoperative findings and the histological post-surgical report were used as a reference standard to define infiltration. Inter- and intra-observer agreement for CT scans and cine-MRI were also computed over a homogenous sample of 14 patients. RESULTS: Cine-MRI had a higher negative predictive value (93% vs. 54%, p < 0.001) than CT scans, higher sensitivity (91% vs. 16%, p < 0.001), as well as greater accuracy (66% vs. 50%, p < 0.001) in detecting cardiovascular invasion. Cine-MRI also showed better inter- and intra-observer agreement for infiltration detection. CONCLUSIONS: Cine-MRI outperforms conventional contrast-enhanced chest CT scans in the preoperative assessment of cardiovascular infiltration by mediastinal or pulmonary tumors, making it a useful imaging modality in the preoperative staging and evaluation of patients with equivocal findings at the chest CT scan stage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA